Sloan TRF-8156-1.6 User Manual

►► Code NumberCode Number
3400100
►► DescriptionDescription
Concealed, sensor-activated, battery-powered, piston type, rough brass, true flushometer for top inlet or rear inlet, wall hung or floor mount, wash down or siphon jet toilets.
►► Flush CycleFlush Cycle
►► SpecificationsSpecifications
● ● Quiet, concealed piston type sensor-activated, battery-powered flushometer with the following features:
● ● Fixed Volume Piston with Filtered O-ring Bypass
● ● Piston color-coded by flush volume for easy identification
● ● Low consumption flush volume for water conservation
● ● Chrome-plated, corrosion-resistant, vandal resistant wall plate
● ● Infrared Sensor with Lobular Sensing Fields for high and low target detection
● ● Latching Solenoid Operator
● ● Electronic Courtesy Flush® Override Button
● ● Four (4) Size AA alkaline Batteries included: Duracell® with DURALOCK Power Preserve Technology™-guaranteed for up to 10 years in storage
● ● “Low Battery” Flashing LED
● ● Initial Set-up Range Indicator Light (first 10 minutes)
● ● Flood prevention feature limits flow to a trickle in wide open position
● ● Heavy duty brass valve body
● ● Safety collar locks activation assembly to prevent access of internal components without shutting off water
● ● Replaceable piston assembly, accessible by removing front wall plate
● ● Concealed shut off sleeve adjusts flow rate- accessible without removing button/bracket assembly
● ● Operating pressure 10-100 psi (0.7-7 bars)
● ● 1-1/2” NPT (female) Inlet standard
● ● 1-1/2” NPSM Outlet standard
►► VariationsVariations
M = Zinc die cast wall plate/button bracket assembly
Inlet adaptor variations
Various flush connection pipe sizes available- consult local Sloan rep or factory
Vacuum breaker- (specify tube length)- required for ASSE 1037 compliance
Model TRF-8156-1.6 Shown
Wall plate dimensions 6” x 6” (152 mm x 152 mm)
►► Automatic OperationAutomatic Operation
The self-adaptive infrared sensor sets the flushing mechanism when the user is detected and completes the flush when the user steps away.
►► HygienicHygienic
Touchless, sensor activation eliminates the need for user contact to help control the spread of infectious diseases.
►► Compliance & CertificationsCompliance & Certifications
This space for Architect/Engineer Approval
TruFlush Flushometer TRF 8156-1.6
2016-23-05 Page 1 of 2
SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. 60131 60131
Ph: 1-800-9-VALVE-9 or 1-847-671-4300 ● Fax: 1-800-447-8329 or 1-847-671-4380 ● http://www.sloan.com
►► Electrical SpecificationsElectrical Specifications
● ● 6 VDC Input - 4 AA Alkaline Batteries
● ● 8 second arming delay
● ● 3 Second Flush Delay
►► Sensor RangeSensor Range
Self-adaptive sensor - maximum 32" (813 mm) distance
►► Battery TypeBattery Type
(4) Size AA Alkaline: Duracell® with DURALOCK Power Preserve Technology™
►► Battery LifeBattery Life
3 Years @ 4,000 Flushes/Month
►► Indicator LightsIndicator Lights
● ● Low Battery Warning
►► Valve Operating Pressure (Flowing)Valve Operating Pressure (Flowing)
10-100 psi (0.7-7.0 bars)
►► OPERATIONOPERATION
1. A continuous, invisible light beam in emitted from the object infrared sensor.
2. As the user enters the beam's effective range, Maximum 32" (813 mm), the beam is reflected into the Scanner Window to
activate the Output Circuit. Once activated, the Output
Circuit continues in a ""hold"" mode for as long as the user
remains within the effective range of the sensor.
3. When the user steps away from the Sensor, the Sensor
initiates an electrical signal that operates the Solenoid. This
initiates the flushing cycle to flush the fixture. The Circuit then
automatically resets and is ready for the next user.
►► ROUGH-INROUGH-IN
TruFlush Flushometer TRF 8156-1.6
2016-23-05 Page 2 of 2
SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. 60131 60131
Ph: 1-800-9-VALVE-9 or 1-847-671-4300 ● Fax: 1-800-447-8329 or 1-847-671-4380 ● http://www.sloan.com
Loading...