TRUFLUSH ELECTRONIC CLOSET AND URINAL FLUSHOMETERS
LIMITED WARRANTY
TruFlush Models:
TRF 8156-1.6
TRF 8156-1.28
TRF 8196-0.5
TRF 8196-0.25
Unless otherwise noted, Sloan Valve Company warrants this product,
manufactured and sold for commercial or industrial uses, to be free
from defects in material and workmanship for a period of three (3)
years (one (1) year for special nishes, SF faucets, PWT electronics
and 30 days for PWT software) from date of rst purchase. During
this period, Sloan Valve Company will, at its option, repair, replace, or
refund the purchase price of any product which fails to conform with
this warranty under normal use and service. This shall be the sole and
exclusive remedy under this warranty. Products must be returned to
Sloan Valve Company, at customer’s cost. No claims will be allowed
for labor, transportation or other costs. This warranty extends only
to persons or organizations who purchase Sloan Valve Company’s
products directly from Sloan Valve Company for purpose of resale.
This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND
BEYOND THE DESCRIPTION ON THE FACE
HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL
DAMAGES OF ANY MEASURE WHATSOEVER.
Rev. 2 (11/16)
PRIOR TO INSTALLATION
This valve is designed for new construction or where there is easily
accessed plumbing for the xture and the valve.
This valve is designed for minimum six inch (152 mm) wall space
depth. Distance from center of the valve (inlet or outlet pipe) to the
nished surface of the wall can vary from 2”-3” (51-76 mm).
Wall plate opening must be of 5.6” x 5.6” (142 x 142 mm). Mud plate
is provided and must accompany valve for proper installation. Mud
plate is removed after wall is nished.
TOOLS REQUIRED FOR INSTALLATION
• Smooth-jawed wrench (at least 2”) • Phillips screwdriver • 5/64” hex wrench (supplied) • Adjusting tool (supplied) • Flathead screwdriver .118”
(3 mm or below) • Wire stripper tool
ROUGH-IN
2” (51 mm) MINIMUM
3” (76 mm) MAXIMUM
1 1/2” NPT
INLET
1 1/2”
OUTLET
18”
2” (51 mm) MINIMUM
3” (76 mm) MAXIMUM
C.L. TO FINISHED WALL
2.0” - 2.4”
(50 mm - 60 mm)
Toilet Seat
(not supplied)
1 1/2” NPT
INLET
1 1/2”
OUTLET
C.L. TO FINISHED WALL
6.9” - 7.3”
(175 mm - 185 mm)
NOTE : Flush Connections shown in dotted lines
not included.
Finished Wall
CLOSET
URINAL
Finished Wall
Finished Floor
!!! IMPORTANT !!!
WITH THE EXCEPTION OF INLET, DO NOT USE
PIPE THREAD
SEALANT OR PLUMBING GREASE ON VALVE
COMPONENTS OR COUPLINGS!
1. CONNECT SUPPLY LINE TO FLUSHOMETER
A.
B.
C.
D.
Inlet
Outlet
A. Flush dirt, debris, and sediment from the supply line prior to connecting.
MAKE SURE SUPPLY LINES ARE FLUSHED OUT. DEBRIS CAN DAMAGE THE VALVE OR CAUSE VALVE TO MALFUNCTION. DO NOT
CONTINUE THE INSTALLATION UNTIL SUPPLY LINES ARE CLEAR.
B. Remove mud guard and save for later use.
DO NOT DISCARD
C. Connect inlet pipe to ushometer using 1.5” (38 mm) union coupling (provided). Tighten securely with xed jaw wrench.
D. Connect outlet pipe to ushometer. Tighten securely with xed jaw wrench.
NOTE: DO NOT EXERT FORCE ON WALL BOX TO TIGHTEN THE FLUSHOMETER. USE FIXED JAW WRENCH TO HOLD THE VALVE.
For Hardwire Use Only:
A. Remove Wall-box Knockout /Cap closest to the conduit connection.
B. Insert conduit and tightly secure it to the wall-box.
C. Run transformer wires through the conduit to the wall-box.
NOTE: TRANSFORMER NOT PROVIDED. IT IS VERY IMPORTANT THAT THE OUTPUT VOLTAGE OF THE TRANSFORMER MUST BE 6VAC
FOR THE UNIT TO FUNCTION PROPERLY. SLOAN EL-386 OR EL-451 IS RECOMMENDED.
2. FINISH WALL AND INSTALL WALL BRACKET
A.
Di.
Snap Clip
B.
Retaining
Screw
A. Reinstall mud guard onto the Flushometer using provided 2” (50 mm) long truss head screws
(qty:4) to protect components from cement.
B. Finish Wall by cementing in place. Use the marks on mud guard to make sure nished wall is
between 2” (51 mm) and 3” (76 mm) from the center line of the pipe.
C. Remove mud guard by removing the 2” (50 mm) long truss head screws and discard mud guard.
i. Make sure to save the screws for wall-bracket installation.
NOTE. WALL PLATE OPENING MUST BE OF 5.6” X 5.6” (142 X 142 MM)
D. Install wall bracket onto ushometer using the four 2” (50 mm) long screws provided.
i. Make sure the wall-bracket snap clip is positioned in bottom left side of the bracket and the
wall-plate retaining screw is bottom right.
ii. Make sure the wall-bracket is positioned plumb and level before tightening the screws.
C.
D.
2
3. INSTALL BATTERY BOX AND SENSOR ASSEMBLY
B.C.
Di.Dii.
E.
Insert Solenoid Connector Here
The TruFlush Sensor assembly is designed to work with both Hardwire and Battery as a back-up or only with
Battery power connection.
A. Install the supplied batteries into the battery box. See section 10 to install the batteries into battery box.
B. Insert the Battery Box on the right side of the ushometer as shown
For Hardwire connection use.
i. Using a wire stripper strip the two wire transformer connection from the conduit.
ii. Insert the wire to the Blue Terminal Block provided with the Sensor Assembly
iii. Tighten the terminal block screws using a athead screwdriver 0.118” (3 mm) or smaller.
iv. Connect the Blue terminal block to the two pins in the back of the Sensor Assembly.
C. Connect Battery Box D-shape connector to Sensor Assembly connector as shown.
NOTE.RED LED WILL START BLINKING WHEN POWER IS CONNECTED TO THE SENSOR ASSEMBLY
D. Mount the Sensor Assembly into the wall-bracket.
i.Align the 4 slots on the Sensor Assembly with the mounting pegs on the Wall Bracket.
ii. Slide the Sensor Assembly all the way down.
E. Insert Flushometer solenoid connector to the sensor assembly.
ii.
iv.
3
3. INSTALL BATTERY BOX AND SENSOR ASSEMBLY (CONT.)
!!! NOTE !!!
THE SENSOR ASSEMBLY COMES WITH THE BUTTON
ALREADY INSTALLED. IN CASE THE BUTTON HAS COME
OFF FROM THE SENSOR ASSEMBLY DURING SHIPMENT,
INSTALL IT FOLLOWING THE FIGURE BELOW.
4. SENSOR OPERATION
A. After power is applied, the Sensor Module will perform its Start-up routine for 15 seconds with LED blinking.
NOTE: A three (3) seconds long Red LED, followed by slow Red LED blinking in the Sensor Window indicates sensor is in the start-up mode. There
will be two (2) Red LED pulses (each two (2) seconds long) in the Sensor Window to indicate the start-up routine is complete.
B. After the start-up routine is complete, in the rst ten (10) minutes of operation, a visible Red LED ashes in the Sensor Window of the TruFlush
Flushometer when a user is detected.
5. TEST SENSOR OPERATION
The TruFlush has a factory set sensing range:
i. Water Closet Models – 22” to 31” (559 mm to 787 mm)
ii. Urinal Models – 9” to 21” (229 mm to 533 mm)
A. Test sensor by stepping in front of the sensor for 10 seconds.
B. After 10 seconds step away from the sensor and listen for a “CLICK”
The factory setting should be satisfactory for most installations. If a range adjustment is required, refer to the range adjustment instructions in this
installation guide (See Section 9).
4
6. ADJUST WATER FLOW
Flushometer is shipped with the ow control adjustment turned OFF.
A. Disconnect Flushometer Solenoid connector from the Sensor Assembly
B. Lift the Sensor Assembly Override Button up to access the activation assembly.
C.Open water ow by turning activation assembly slowly COUNTERCLOCKWISE using adjusting tool and a screwdriver or a wrench.
!!! NOTE !!!
MAKE SURE SOLENOID CONNECTOR GOES THROUGH THE
CENTER OF THE ADJUSTING TOOL TO AVOID DAMAGE TO THE
CABLE.
D.Connect Flushometer Solenoid connector to the Sensor Assembly.
E. Activate Flushometer by pressing the Override Button.
F. Adjust Activation Assembly after each ush until the ow rate delivered properly cleanses the xture (turn CLOCKWISE to lessen ow and
COUNTERCLOCKWISE to increase ow).
MAKE SURE FLUSHOMETER SOLENOID CONNECTOR IS
DISCONNECTED FROM SENSOR ASSEMBLY EVERY TIME
BEFORE ROTATING ACTIVATION ASSEMBLY.
UNDER NO CIRCUMSTANCES SHOULD THE SOLENOID BE
Pass Solenoid Cable
!!! NOTE !!!
!!! NOTE !!!
REMOVED OR ADJUSTED.
through to avoid damage
!!! IMPORTANT !!!
THE FLUSHOMETER IS ENGINEERED FOR QUIET OPERATION.
EXCESSIVE WATER FLOW CREATES NOISE, WHILE TOO
Increase Flow
LITTLE WATER FLOW MAY NOT SATISFY THE NEEDS OF THE
FIXTURE. PROPER ADJUSTMENT IS MADE WHEN PLUMBING
FIXTURE IS CLEANSED AFTER EACH FLUSH WITHOUT
SPLASHING WATER OUT FROM THE LIP AND A QUIET
FLUSHING CYCLE IS ACHIEVED.
Decrease Flow
THE ACTIVATION ASSEMBLY SHOULD NEVER BE OPENED TO
THE POINT WHERE THE FLOW FROM THE VALVE EXCEEDS
THE FLOW CAPABILITY OF THE FIXTURE. IN THE EVENT
OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO
ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.
!!! IMPORTANT !!!
7. INSTALL WALL PLATE
A.
B.
C.
E.
Retaining Screw
Flushometer is shipped with the ow control adjustment turned OFF.
A. Make sure retaining screw on bracket is fully tightened
B. Slide Sensor Assembly all the way up.
C. Align Wall Plate cut out with the window and Override Button of Sensor Assembly and push Wall Plate all the way in.
i.Make sure sensor window and button are sitting inside the wall plate cut out.
D. Slide Wall Plate all the way down.
E. Unscrew the retaining screw using supplied Allen key until it touches wall plate.
F. Make sure Wall Plate doesn’t slide up.
DO NOT UNSCREW ANYMORE ONCE SCREW
TOUCHES WALL PLATE.
!!! NOTE !!!
5
8. OPERATION
A. A continuous, INVISIBLE light beam is emitted from the TruFlush Sensor.
B. After the user enters the beam’s effective range, 22 to 31 inches (559 mm to 787 mm) for closet installations and 9 to 21 inches (381 mm
to 762 mm) for urinal installations for ten (10) seconds the ushometer is armed.
C. When the user steps away, the sensor initiates a “one-time” signal that activates the ushing cycle to ush the xture (1 second delay for urinal,
3 seconds delay for closet). The Circuit automatically resets and is ready for the next user.
9. RANGE ADJUSTMENT (ADJUST ONLY IF NECESSARY)
The TruFlush has a factory set sensing range:
Water Closet Models - 22” to 31” (559 mm to 787 mm)
Urinal Models - 9” to 21” (229 mm to 533 mm)
The Factory setting should be satisfactory for most installations. If the range is too short (i.e. not picking up users) or too long (i.e., picking up
opposite wall or stall door) the range can be adjusted.
NOTE: WATER DOES NOT HAVE TO BE TURNED OFF TO ADJUST RANGE.
A. Make sure to remove all the non-permanent targets in sensor view area.
B. Push Override button for 20-30 seconds.
C. The Red LED in the sensor window starts slow blinking.
D. Release the button during the LED blinking.
E. The TruFlush will enter into distance setting mode.
F. The setting mode will run for one minute.
WHEN ADJUSTING RANGE FOR CLOSET SENSOR, MAKE
SURE THE CLOSET DOOR IS ALL THE WAY CLOSED FOR
WHEN ADJUSTING RANGE FOR URINAL SENSOR, MAKE SURE
TO SET-UP A PROPER TARGET IN FRONT OF URINAL SENSOR
FOR PROPER RANGE ADJUSTMENTS