►► Code NumberCode Number
3400113
►► DescriptionDescription
Concealed, sensor-activated, hardwired with battery backup,
piston type, rough brass, true flushometer for top inlet or rear inlet
Urinals.
►► Flush CycleFlush Cycle
Urinal Flush Cycle 0.25 gpf/1.0 Lpf
►► SpecificationsSpecifications
● ● Quiet, concealed piston type sensor-activated, hardwired
flushometer with the following features:
● ● Fixed Volume Piston with Filtered O-ring Bypass
● ● Piston color-coded by flush volume for easy identification
● ● High Efficiency flush volume for water conservation
● ● Chrome-plated zinc, corrosion-resistant, vandal resistant wall
plate
● ● Infrared Sensor with Lobular Sensing Fields for high and low
target detection
● ● Latching Solenoid Operator
● ● Electronic Courtesy Flush® Override Button
● ● Non-Hold-Open Integral Solenoid Operator
● ● Die Cast Sensor Plate with no visible Fasteners (for 2-gang
Electrical Box)
● ● Die Cast Solenoid Wall Flange (for 2-gang Electrical Box)
● ● Initial Set-up Range Indicator Light (first 10 minutes)
● ● Flood prevention feature limits flow to a trickle in wide open
position
● ● Heavy duty brass valve body
● ● Safety collar locks activation assembly to prevent access of
internal components without shutting off water
● ● Replaceable piston assembly, accessible by removing front wall
plate
● ● Concealed shut off sleeve adjusts flow rate- accessible without
removing button/bracket assembly
● ● Operating pressure 10-100 psi (0.7-7 bars)
● ● 1-1/2” NPT (female) Inlet standard
● ● 1-1/2” NPSM Outlet standard
►► VariationsVariations
M = Zinc die cast wall plate/button bracket assembly
Inlet adaptor variations
Various flush connection pipe sizes available- consult local Sloan rep
or factory
Vacuum breaker- (specify tube length)- required for ASSE 1037
compliance
►► Automatic OperationAutomatic Operation
The self-adaptive infrared sensor sets the flushing mechanism when
the user is detected and completes the flush when the user steps
away.
►► HygienicHygienic
Touchless, sensor activation eliminates the need for user contact to
help control the spread of infectious diseases.
►► Compliance & CertificationsCompliance & Certifications
This space for Architect/Engineer Approval