Simfer 8668,8658 Instruction Manual

Instruction Manual
DECORATIVE CHIMNEY HOOD
DEKORATIVNA KAMINSKA NAPA
GB
H10-20-300-031 Rev 001
Navodila za uporabo
SI
Dear Customer,
Thank you very much for your preference for Simfer products. Our objective is to ensure that you enjoy this product, manufactured environmentally-friendly with a total sense of quality in a precise working environment at our modern facilities, most efficiently.
We recommend you to read the instruction manual carefully and keep it handy before you use this Simfer chimney hood so that it maintains its quality just like the first day you bought it and serves you most efficiently.
NOTE:
This Instruction Manual has been prepared for a variety of models. Some of the features specified in the Manual may not exist in your device. These features are marked with *.
Our devices are designed for domestic use. They are not for professional use.
"PLEASE READ THE INSTRUCTIONS BEFORE YOU INSTALL OR USE THIS DEVICE."
This product has been manufactured in an environmentally-friendly and modern plants without harming the nature.
“Conforms with the EEE Regulations."
GB
CONTENTS:
1.SAFETY INTRODUCTIONS 3
2. INTRODUCTION AND TECHNICAL DRAWING OF THE CHIMNEY HOOD... 4
3.INSTALLATION OF CHIMNEY HOOD........................................ 5
3.1.Location of the Chimney Hood.........................
3.2.Installation of Mounting Bracket to the Chimney
Hood...................................................................
3.3.Installation of Wall Mounting Bracket...............
3.4.Installation of Inner Duct Mounting Bracket .....
4.MOUNTING THE CHIMNEY HOOD ON THE WALL..........................6
4.1.Leveling the Chimney Hood..............................
4.2.Mounting the Aluminum Pipe...........................
5. .....................................7FUNCTIONS OF THE CHIMNEY HOOD
5.1.Control Panel and its Functions.......................
5.2.Operating the Chimney Hood..........................
5.3.In ducted use................................................
5.4.Round Charcoal Filter.....................................
5.5.Use of Charcoal Filter.....................................
5.6.Installation of Charcoal Filter..........................
5.7.Use of Aluminum Cartridge Filter.....................
6.REPLACING THE BULB........................................................ 9
7.MAINTENANCE OF THE CHIMNEY HOOD................................. 10
8.IF CHIMNEY HOOD DOES NOT WORK.....................................11
1.SAFETY INSTRUCTIONS
Ÿ This product is designed for domestic use. Ÿ Product Voltage is 220-240 Volts 50Hz. Ÿ Power cord of your product is fitted with grounded plug. This cord must be
plugged into a grounding socket.
Ÿ All electrical installation must be done by a qualified electrician. Ÿ Installation by unqualified persons may lead the product run with lower
performance, be damaged or cause accidents.
Ÿ Power supply cord should not be jammed or crushed. Power cord should
not be close to hobs, etc, otherwise it may melt and cause fire.
Ÿ Do not plug in the product into a socket before the installation is complete. Ÿ Make sure the mains switch is easily accessible in order to cut the power of
the product in case of any danger.
Ÿ Do not touch the bulbs of your product if used for a long period of time. The
bulbs will be hot and may burn your hand.
Ÿ Kitchen chimneys are designed for domestic use. If used for other
purposes, it may lead to a failure and not be covered under the warranty.
Ÿ Follow the authorized agencies' rules and regulations regarding letting out
the air. (This warning does not apply to usage with non-ducted chimney hoods.)
Ÿ Food that may burst into flames should not be cooked under the device. Ÿ Turn on the product after you place pots, pans, etc on the hobs. Otherwise
excess heat may cause deformation of some parts of your product.
Ÿ Do not leave hot oil on the hobs. Pans with hot oil inside may cause self-
ignition.
Ÿ When cooking i.e. deep frying, hot oil may burst into flames. Be careful on
your curtains and cloths.
Ÿ Make sure you replace the filters at the recommended intervals. Filters not
replaced on time carry fire risk due to increase of grease on them.
Ÿ Do not use non-fire-resistant materials instead of filters. Ÿ Keep the potentially dangerous packaging materials away from children. Ÿ Do not use your product without a filter, do not remove filters when the
product is operating.
Ÿ In case of start of flames, cut off the power of the chimney fan and cooker.
(Cut off the power by unplugging the device).
GB
3
1.SAFETY INSTRUCTIONS
Ÿ Turn off the hobs before you remove pots, pans, etc. Ÿ If the cleaning is not done periodically, your product may carry fire risk. Ÿ Cut off the power supply before any maintenance work. (Cut off the power
by unplugging the device.)
Ÿ For duct-out chimney hoods, use pipes with a diameter of 150mm or
120mm. You should minimize the ducting distance with minimum bends.
Ÿ Make sure your children do not play with the product. Do not let young
children operate the product.
Ÿ If the power cord is damaged, the damaged cord should be replaced by the
manufacturer or its service agent or similarly specialized personnel in order to avoid a dangerous situation.
Ÿ In case of start of flames, cut off the power of the chimney fan and cooker
and cover the flame. Do not use water to extinguish the fire.
Install "MAX 6 A" fuse for the extractor fan.
2. INTRODUCTION AND TECHNICAL DRAWING OF THE CHIMNEY HOOD
4
Inner Duct
Outer Duct
Lighting
Filter
Control Panel
472mm
400mm
350mm
285mm
308mm
460mm
596-896mm
GB
5
0
80
50
130
220
180
250
MAX
90
80
70
40
30
10
20
50
0
60
Electric Stove
Min.: 450 mm. / Max.:550 mm.
Gas Stove
Min.: 550 mm. / Max.:650 mm.
3.INSTALLATION OF CHIMNEY HOOD
3.1.Location of the Chimney Hood
3.2.Installation of Mounting Bracket to the Chimney Hood
Fix the 2 (two) Mounting brackets among the installation accessories to the chimney hood with one 1 screw nut as shown in Figure 1. Make sure mounting brackets are inserted in motor box.
3.3.Installation of Wall Mounting Bracket
3 drywall (8mm) anchors are nailed into the holes drilled according to installation template (A,B,C,D). They are fixed into the wall with 2 brackets as shown in Figure 2.
A
C D
B
Installation Template
Fig 1 Fig 2
6
Fig 3
Fig 4
3.4.Installation of Inner Duct Mounting Bracket
2 fixing holes are drilled on the wall with Ø6mm electric drill at a suitable height and place to fix the inner duct hanger plate onto the wall. 6mm drywall anchors are nailed into those holes and inner duct mounting brackrets are pinned down. At the last step of chimney hood installation, the inner duct is screwed on the inner duct mounting brackets.
4.MOUNTING THE CHIMNEY HOOD ON THE WALL
Lift the chimney hood body and fix the hanger plates onto the wall anchors as shown in Figure 3.
4.1.Leveling the Chimney Hood
If the chimney hood is inclined on one side, the chimney hood can be leveled with the adjustment screws as shown in Figure 4. Once the balancing is complete, the screws shown in Figure 5 must be fixed tightly. After this, fix the body with one screw through the hole on the body.
4.2.Mounting the Aluminum Pipe
Place the aluminum pipe on the plastic duct. Place the other end of the pipe into the air outlet in the kitchen. Figure 6
Fig 5
Fig 6
Loading...
+ 16 hidden pages