293 Wright St., Delavan, WI 53115
Phone: 1-800-468-7867 1-800-546-7867 Fax: 1-800-390-5351
Web Site: http://www.simerpump.com
OWNER’S MANUAL
Corrosion Resistant Centrifugal
Lawn Sprinkler Pump
NOTICE D’UTILISATION
Pompe centrifuge et inoxydable pour l’arrosage du gazon
MANUAL DEL USUARIO
Bomba centrifuga resistente a la corrosion para rociadores de césped
® |
1538 0195 SIM |
MOD. 3410P, 3415P, 3420P |
Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Installation/Fonctionnement/Pièces |
Instalación/Operación/Piezas |
Pour plus de renseignements |
Para mayor información sobre el |
concernant l’utilisation, |
funcionamiento, instalación o |
l’installation ou l’entretien, |
mantenimiento de la bomba: |
Call 1-800-468-7867 |
Composer le 1 (800) 468-7867 |
Llame al 1-800-468-7867 |
||
English . . . . . . . . . . . . . . |
Pages 2-10 Français . . . . . . . . . . . |
Pages 11-19 |
Español . . . . . . . . . . . |
Paginas 20-28 |
©2008 |
SIM190 (Rev. 4/16/09) |
Safety |
2 |
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for
one of the following signal words and be alert to the potential for personal injury:
warns about hazards that will cause serious personal injury, death or major property damage if ignored.
warns about hazards that can cause serious personal injury, death or major property damage if ignored.
warns about hazards that will or can cause minor personal injury or property damage if ignored.
The label NOTICE indicates special instructions which are important but not related to hazards.
Carefully read and follow all safety instructions in this manual and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
Make workshops childproof; use padlocks and master switches; remove starter keys.
WARNING
Hazardous voltage. Can shock, burn, or cause death.
Ground pump before connecting to power supply. Disconnect power before working on pump, motor or tank.
Wire motor for correct voltage. See “Electrical”
section of this manual and motor nameplate.
Ground motor before connecting to power
supply.
Meet National Electrical Code, Canadian
Electrical Code, and local codes for all wiring.
Follow wiring instructions in this manual
when connecting motor to power lines.
ELECTRICAL SAFETY
Capacitor voltage may be hazardous. To discharge motor capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor terminals together.
Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
GENERAL SAFETY
Do not touch an operating motor. Modern motors can operate at high temperatures. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling.
Pump is designed as a lawn sprinkler only. To avoid heat built-up, over pressure hazard and possible injury, do not use in a domestic water system. Do not use as a booster pump; pressurized suction may cause pump body to explode.
Do not allow pump or any system component to freeze. To do so will void warranty.
Pump water only with this pump.
Periodically inspect pump and system components.
Wear safety glasses at all times when working on pumps.
Keep work area clean, uncluttered and properly lighted; store properly all unused tools and equipment.
Keep visitors at a safe distance from the work areas.
“Dead Heading” a pump means running the pump while little or no water is released from the system. Never run pump above recommended pressure shown on the performance chart.
WARNING
Hazardous pressure!
Do not run pump against closed discharge.
Release all pressure on system before working on any component.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Table of Contents |
3 |
Thank you for purchasing a top quality, factory tested pump. |
|
|
Page |
General Safety ..................................................................................................... |
2 |
Warranty .............................................................................................................. |
3 |
Installation ........................................................................................................ |
4,5 |
Electrical ........................................................................................................... |
6,7 |
Operation ......................................................................................................... |
8,9 |
Troubleshooting ................................................................................................... |
9 |
Repair Parts ....................................................................................................... |
10 |
RETAIN ORIGINAL RECEIPT FOR YOUR RECORDS.
LIMITED WARRANTY
SIMER warrants to the original consumer purchaser (“Purchaser” or “You”) of its products that they are free from defects in material and workmanship for a period of twelve (12) months from the date of the original consumer purchase.
If, within twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below. The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair or replacement of product only – Purchaser pays all removal, installation, labor, shipping, and incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store. Contact SIMER Customer Service at 1-800-468-7867 / 1-800-546-7867.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet where it was purchased immediately after the discovery of any alleged defect. SIMER will subsequently take corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the warranty expires.
SEWAGE PUMPS
DO NOT return a sewage pump (that has been installed) to your retail store. Contact SIMER Customer Service. Sewage pumps that have seen service and been removed carry a contamination hazard with them.
If your sewage pump has failed:
• Wear rubber gloves when handling the pump;
• For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
• Dispose of the pump according to local disposal ordinances.
Exceptions to the Twelve (12) Month Limited Warranty |
|
||
|
Product |
Warranty Period |
|
|
BW85P, CM10, CMK, M40, M40P |
90 days |
|
|
|
2300, 2310, 2330, 2520ULST, 2943, 2955, 2956, 2957, 2960, 5023SS, A5500 |
2 Years |
|
|
|
|
|
|
4” Submersible Well Pumps, 2945, 2958, 2975PC, 2985, 3075SS, 3983, 3984 |
3 Years |
|
|
|
|
|
|
Pre-Charge Water System Tank, 3985, 3986 |
5 Years |
3963, 3988, 3995, 3997 |
Lifetime |
||
|
|
|
|
General Terms and Conditions
You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not apply to the following: (1) acts of God; (2) products which, in SIMER’s sole judgement, have been subject to negligence, abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive remedy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.
SIMER • 293 Wright St., Delavan, WI U.S.A. 53115 Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351
Web Site: http://www.simerpumps.com
Installation |
4 |
BEFORE YOU INSTALL YOUR PUMP
NOTICE: Well must not be more than 20' (6.1m) depth to water.
Step 1. Long runs and many fittings increase friction and reduce flow. Locate pump as close to well as possible; use as few elbows and fittings as possible. Be sure suction line is straight and angles toward pump.
Step 2. Be sure well and pipe are clear of sand, dirt and scale. Foreign matter will plug pump and void warranty. Use new pipe for best results.
Step 3. Protect pump and all piping from freezing. Freezing will split pipe, damage pump and void warranty. Check locally for frost protection requirements (usually pipe must be 12" (30.5cm) below frost line and pump must be insulated).
Step 4. Be sure all pipes and foot valve are clean and in good shape.
Step 5. No air pockets in suction pipe.
Step 6. No leaks in suction pipe. Use Teflon tape or Plasto-Joint Stik to seal pipe joints.
Step 7. Unions installed near pump and well will aid in servicing. Leave room to use wrenches.
Pump body may explode if used as booster pump. DO NOT use in booster application.
Motor normally operates at high temperature and will be too hot to touch. It is protected from heat damage during operation by an automatic internal cutoff switch. Before handling pump or motor, stop motor and allow it to cool for 20 minutes.
WELL PIPE INSTALLATION
NOTICE: Use installation method below which matches your well type.
CASED WELL/DUG WELL INSTALLATION
Step 1. Inspect foot valve to be sure it works freely. Inspect strainer to be sure it is clean and secure.
Step 2. Connect foot valve and strainer to first length of suction pipe and lower pipe into well. Add sections of pipe as needed, using Teflon tape on male threads (use 1-1/2" pipe for suction pipe). Be sure all suction pipe is leakproof or pump will lose prime and fail to pump. Install foot valve 10 to 20 ft. (3 to 6 m) below lowest level to which water will drop while pump is operating (pumping water level). Your well driller can furnish this information.
Step 3. To prevent sand and sediment from entering pumping system, foot valve/strainer should be at least 5 ft. (1.5 m) above bottom of well.
Step 4. When proper depth is reached, install sanitary well seal over pipe and in well casing. Tighten bolts to seal casing.
Step 5. When using foot valve, a priming tee and plug are recommended. (Figure 1).
Priming plug
Priming tee
Suction pipe
20' (6 m) max. |
|
Standing water |
|
level (pump off) |
Drawdown water level (pump on)
10-20' (3-6 m)
At least 5 feet (1.5 m)
Foot
Valve
828 0993
Figure 1: Cased/Dug Well Installation
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Installation |
5 |
DRIVEN POINT INSTALLATION
Step 1. Connect suction pipe to drive point (Figure 2). Keep horizontal pipe run as short as possible. Use Teflon tape on male pipe threads. Multiple well points may be necessary to provide sufficient water to pump.
Step 2. Install check valve in horizontal pipe. Flow arrow on check valve must point toward pump.
Discharge
Pipe
Gate valve
To sprinkler
heads
Check valve
Suction
Pipe
Tosprinkler heads
Multiple well points
Figure 2: Driven Point Installation, Multiple Well Points
HORIZONTAL PIPING
FROM WELL TO PUMP
Step 1. Pump performance will be decreased if less that 1-1/2" pipe is used as suction pipe.
Step 2. To aid priming on well point installations, install line check valve. Be sure check valve flow arrow points toward pump.
DISCHARGE PIPE SIZES
Discharge pipe size should be increased to reduce pressure losses caused by friction on long pipe runs.
•Up to 100' (30.5 m) run: Same size as pump discharge port.
•100' - 300' (30.5 - 91.4 m) run: Increase one pipe size.
•300' - 600' (91.4 - 182.9 m) run: Increase two pipe sizes.
LAWN SPRINKLING APPLICATION
This pump is designed for lawn sprinkling. Delivers plenty of water at full sprinkler pressure. Pumps from pond, cistern or well points.
Pump discharge can be divided to supply 4 or more sprinkler systems.
Do not use in booster pump applications.
PUMP/PIPING INSTALLATION
If turning pump on and off by pressure, a pressure switch and tank are required. For proper installation and operation instructions call Customer Service.
Use rigid pipe. Do not use hose or plastic tubing. See “Well Pipe Installation” for more information.
NOTICE: Use only Teflon tape or Teflon based joint compounds for making all threaded connections to the pump itself. Do not use pipe joint compounds on plastic pumps: they can react with the plastic in pump components. Make sure that all pipe joints in the suction pipe are air tight as well as water tight. If the suction pipe can suck air, the pump will not be able to pull water from the well.
Step 1. Bolt pump to solid, level foundation.
Step 2. Support all piping connected to pump.
Step 3. Wrap 1-1/2 to 2 layers of Teflon tape clockwise (as you face end of pipe) on all male threads being attached to pump.
Step 4. Tighten joints hand tight plus 1-1/2 turns. Do not overtighten.
Step 5. Replace prime plug with pressure gauge. This will aid in sizing zones, troubleshooting, and following pump performance chart.
NOTICE: Install pump as close to well head as possible. Long piping runs and many fittings create friction and reduce flow.
NOTICE: For long horizontal pipe runs, install a priming tee between check valve and well head (Fig. 1). For driven point installations, install check valve. Be sure that check valve flow arrow points toward pump.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Electrical |
6 |
MOTOR SWITCH SETTINGS
Dual-voltage motors (motors that can operate at either 115 or 230 volts), are set at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor.
NOTE: Never wire a 115 volt motor to a 230 volt line.
REMOVE MOTOR END COVER
If you have a dual-voltage motor, and will connect it to 115 volts, follow the procedure below.
End Cover Screws
Motor
End Cover
Figure 3: Removing Motor End Cover
You will need to remove the motor end cover to change the voltage setting.
Your motor terminal board (located under the motor end cover) should look like Figure 4.
SELECTING VOLTAGE WITH DIAL TYPE VOLTAGE SELECTOR
Ground Wire
Terminal
Power Supply
Terminals
For 115 Volt
For 230 Volt
Figure 4:Voltage set to 230 volts, Dial Type; turn dial to select 115 volts.
To change to 115 volts:
1.Make sure power is off.
2.Turn the dial counter-clockwise until 115 shows in the dial window.
3.Attach the power lead wires to the power lead terminals. Make sure the wires are secure.
4.Attach the ground wire to the green ground screw
5.Reinstall the Motor end cover
Go to Wiring Connections below.
Hazardous voltage. Can shock, burn, or cause death. Disconnect power to motor before working on pump or motor. Ground motor before connecting to power supply.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Electrical |
7 |
WIRING
Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or fatal electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical
connections.
Supply voltage must be within ±10% of nameplate voltage. Incorrect voltage can cause fire or dam-
age motor and voids warranty. If in doubt consult a licensed electrician.
Use wire size specified in Wiring Chart (Page 7). If possible, connect pump to a separate branch cir-
cuit with no other appliances on it.
Wire motor according to diagram on motor nameplate. If nameplate diagram differs from diagrams
above, follow nameplate diagram.
Step 1. Install, ground, wire and maintain this pump in accordance with electrical code requirements. Consult your local building inspector for information about codes.
Step 2. Provide a correctly fused disconnect switch for protection while working on motor. Consult local or national electrical codes for switch requirements.
Step 3. Disconnect power before servicing motor or pump. If the disconnect switch is out of sight of pump, lock it open and tag it to prevent unexpected power application.
Step 4. Ground the pump permanently using a wire of the same size as that specified in wiring chart, below. Make ground connection to green grounding terminal under motor canopy marked GRD. or .
Step 5. Connect ground wire to a grounded lead in the service panel or to a metal underground water pipe or well casing at least 10 feet long. Do not connect to plastic pipe or insulated fittings.
Step 6. Protect current carrying and grounding conductors from cuts, grease, heat, oil, and chemicals.
Step 7. Connect current carrying conductors to terminals L1 and L2 under motor canopy. When replacing motor, check wiring diagram on motor nameplate against Figure 4. If the motor wiring diagram does not match the diagram, follow the diagram on the motor.
IMPORTANT: 115/230 Volt single phase models are shipped from factory with motor wired for 230 volts. If power supply is 115 volts, remove motor canopy and change switch dial on motor as shown in Figure 4. Do not try to run motor as received on 115 volt current.
Step 8. Motor has automatic internal thermal overload protection. If motor has stopped for unknown reasons, thermal overload may restart it unexpectedly, which could cause injury or property damage. Disconnect power before servicing motor.
Step 9. If this procedure or the wiring diagrams are confusing, consult a licensed electrician.
Wiring Chart – Recommended Wire and Fuse Sizes for 115 and 230 volts
|
|
|
|
Branch |
AWG |
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
Max. |
Fuse |
Min. |
0 - 100 |
101 |
- 200 |
201 |
- 300 |
301 - 400 |
401 |
- 500 |
Pump |
|
|
Load |
Rating* |
Wire |
(0 - 30) |
(31 |
- 61) |
(62 |
- 91) |
(92 - 122) |
(123 |
- 152) |
Model |
HP |
Volts |
Amp |
Amp |
Size (mm2) |
|
|
AWG WIRE SIZE (mm2) |
|
|
|||
3410P |
1 |
115/230 |
14.8/7.4 |
20/15 |
12/14 (3/2) |
12/14 (3/2) |
8/14 (8.4/2) |
6/14 (14/2) |
6/12 (14/3) |
4/10 (21/5.5) |
|||
3415P |
1-1/2 |
115/230 |
19.2/9.6 |
25/15 |
10/14 (5.5/2) |
10/14 (5.5/2) |
8/14 (8.4/2) |
6/12 (14/3) |
4/10 (21/5.5) |
4/10 (21/5.5) |
|||
3420P |
2 |
115/230 |
24/12 |
30/15 |
10/14 (5.5/2) |
10/14 (5.5/2) |
6/14 (14/2) |
6/12 (14/3) |
4/10 (21/5.5) |
4/10 (21/5.5) |
* Dual element or Fusetron time delay fuses recommended for all motor circuits.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Operation |
8 |
PRIMING THE PUMP
NOTICE: 'Priming' refers to pump expelling all air in the system and beginning to move water from its source out into system. It does not refer only to pouring water into pump (although pouring water in is usually the first step).
NEVER run pump dry. Running pump without water may cause pump to overheat, damaging seal and possibly causing burns to
persons handling pump. Fill pump with water before starting.
Step 1. Remove priming plug.
Step 2. Make sure suction and discharge valves and any hoses on discharge side of pump are open.
Step 3. Fill pump and suction pipe with water (Figure 5).
NEVER run pump against closed discharge. To do so can boil water inside pump, causing hazardous pressure in unit, risk of explosion and possibly scalding persons handling pump (Figure 6). Replace priming plug with pressure gauge to monitor pressure so that it is not allowed to exceed maximum pumping pressures according to performance chart.
647 1293
Figure 5: Fill Pump Before Starting
Step 4. Replace priming plug, using Teflon tape on thread; tighten plug.
NOTICE: If priming tee and plug have been provided for long horizontal run, be sure to fill suction pipe through this tee and replace plug. (Use Teflon tape on plug.)
Step 5. Start pump; water should be produced in 10 minutes or less, time depends on depth to water (not more than 20' (6 m)) and length of horizontal run (10' (3 m) of horizontal suction pipe = 1' (30.5 cm) of vertical lift due to friction losses in pipe). If no water is produced within 10 minutes, stop pump, release all pressure, remove priming plug, refill and try again.
1117 0993
Figure 6: Do Not Run Pump With Outlet Shut Off
NOTICE: Open water system faucets before priming pump for the first time.
Remove priming plug.
Step A. Fully open control valve (turn counterclockwise).
Step B. Fill pump and suction pipe with water.
Step C. Replace priming plug, using Teflon tape on plug thread; tighten plug.
To prevent explosion, do the following:
Step A. Be sure discharge (valve, pistol grip hose nozzle, etc.) is open whenever pump is running.
Step B. If pump fails to produce water when attempting to prime, release all pressure, drain pump and refill with cold water after every attempt.
Step C. When priming, monitor pump body and piping temperature. Motor will warm up; this is normal. If pump body or piping begin to feel warm to touch, shut off pump and allow system to cool. Release all pressure in system and refill pump and piping with cold water.
Step D. Make sure discharge pipe and zone size are not too small for this pumps performance.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Operation |
|
|
|
|
|
|
|
|
|
|
|
|
9 |
||
|
|
|
|
|
Performance Chart / GPM(LPM) |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|||||
Discharge |
|
3410P – 1 HP |
|
|
3415P – 1-1/2 HP |
|
|
|
3420P – 2 HP |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Height Of Pump Above Water / Feet (Meter) |
|
|
|
|
|
|||||
Pressure |
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PSI (kPa) |
5’ (1.5) |
10’ (3) |
15’ (4.6) |
20’ (6.1) |
5’ (1.5) |
10’ (3) |
15’ (4.6) |
20’ (6.1) |
5’ (1.5) |
10’ (3) |
15’ (4.6) |
20’ (6.1) |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 (69) |
55 (208) |
49 (185) |
48 |
(181) |
45 (170) |
67 (254) |
61 (231) |
56 |
(212) |
46 (174) |
69 (261) |
64 |
(242) |
65 (246) |
62 (235) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
15 (103) |
51 (193) |
46 (174) |
45 |
(170) |
44 (166) |
66 (250) |
58 (220) |
55 |
(208) |
45 (170) |
65 (246) |
62 |
(235) |
60 (227) |
57 (215) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20 (138) |
45 (170) |
42 (159) |
39 |
(148) |
37 (140) |
61 (231) |
56 (212) |
54 |
(204) |
44 (166) |
59 (223) |
56 |
(212) |
54 (204) |
52 (197) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
25 (172) |
38 (144) |
35 (132) |
32 |
(121) |
29 (110) |
55 (208) |
52 (197) |
51 |
(193) |
43 (163) |
52 (197) |
50 |
(189) |
48 (181) |
46 (174) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30 (207) |
31 (117) |
28 (106) |
24 (90) |
20 (76) |
48 (181) |
45 (170) |
44 |
(166) |
37 (140) |
47 (178) |
45 |
(170) |
42 (159) |
40 (151) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
35 (241) |
23 (87) |
19 (72) |
16 (60) |
11 (42) |
39 (147) |
37 (140) |
34 |
(129) |
28 (106) |
42 (159) |
38 |
(144) |
35 (132) |
32 (121) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
40 (276) |
17 (64) |
13 (49) |
8 |
(30) |
|
33 (125) |
27 (102) |
20 (76) |
11 (42) |
34 (129) |
30 (113) |
27 (102) |
23 (87) |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
45 (310) |
|
|
|
|
|
18 (68) |
14 (53) |
8 |
(30) |
|
25 (95) |
18 (68) |
13 (49) |
10 (38) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50 (345) |
|
|
|
|
|
|
|
|
|
|
14 (53) |
7 |
(26) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
All models except 3420P have discharge and suction size of 1-1/2" NPT. 3420P has 2" NPT suction and discharge.
Troubleshooting
Capacitor voltage may be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
SYMPTOM |
POSSIBLE CAUSE(S) |
CORRECTIVE ACTION |
|
Motor will not run |
Disconnect switch is off |
Be sure switch is on. |
|
|
Fuse is blown or circuit breaker tripped |
Replace fuse or reset circuit breaker. |
|
|
Starting switch is defective |
DISCONNECT POWER; Replace starting switch. |
|
|
Wires at motor are loose, |
Refer to instructions on wiring (Page 7). DISCONNECT POWER; check and |
|
|
disconnected, or wired incorrectly |
tighten all wiring. |
|
|
|
|
|
Motor runs hot and |
Motor is wired incorrectly |
Refer to instructions on wiring. |
|
overload kicks off or |
Voltage is too low |
Check voltage being supplied to motor. Install heavier wiring if wire size is |
|
motor does not run |
|||
|
too small (See Electrical / Wiring Chart). |
||
and only hums |
|
||
|
|
||
Motor runs but no |
Pump in new installation did |
In new installation: |
|
water is delivered* |
not pick up prime through: |
|
|
|
1. Improper priming |
1. Re-prime according to instructions. |
|
|
2. Air leaks |
2. Check all connections on suction line, with soapy water or |
|
|
|
shaving cream. |
|
* (Note: Stop pump; |
3. Leaking foot valve or check valve |
3. Replace foot valve or check valve. |
|
then check prime |
4. Pipe size too small |
4. Re-pipe using size of suction and discharge ports on pump. |
|
before looking for |
Pump has lost prime through: |
In installation already in use: |
|
other causes. |
|||
1. Air leaks |
1. Check all connections on suction line and shaft seal with soapy water. |
||
Unscrew priming |
|||
2. Water level below suction pipe inlet |
2. Lower suction line into water and re-prime. If receding water level |
||
plug and see if water |
|
in well exceeds 25’ (7.6M), a deep well pump is needed. |
|
is in priming hole). |
Impeller is plugged |
Clean impeller. |
|
|
|||
|
Check valve or foot valve is stuck shut |
Replace check valve or foot valve. |
|
|
Pipes are frozen |
Thaw pipes. Bury pipes below frost line. Heat pit or pump house. |
|
|
Foot valve and/or strainer are |
Raise foot valve and/or strainer above bottom of water source. |
|
|
buried in sand or mud |
Clean foot valve and strainer. |
|
|
|
|
|
*Pump does not |
Water level in well is lower than |
A deep well jet will be needed if your well is more than 25’ (7.6M) |
|
deliver water to full |
estimated |
depth to water. |
|
capacity |
Steel piping (if used) is corroded or |
Replace with plastic pipe where possible, otherwise with new steel pipe. |
|
|
|||
|
limed, causing excess friction |
|
|
|
Piping is too small in size |
Re-pipe using size of suction and discharge ports on pump. |
|
|
Pump not being supplied with |
Add additional well points. |
|
|
enough water |
|
|
Pump leaks |
Clamp loose |
STOP PUMP, tighten clamp nut 1-2 turns. Alternately tighten and tap on |
|
around clamp |
|
clamp with mallet to seat O-Ring. Do not overtighten. |
|
|
|
|
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867