Simer Pumps 2305-04, 2310-04, 2300-04, 2355-04 User Manual

4 (1)
OWNER’S MANUAL
Submersible Utility Pumps
NOTICE D’UTILISATION
Pompe submersible à usage général
MANUAL DEL USUARIO
Bomba sumergible de uso general
For further operating, installation, or maintenance assistance:
Call 1-800-468-7867 / 1-800-546-7867
English . . . . . . . . . . . . . . . Pages 2-6
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,
Composer le
1 (800) 468-7867 /
1 (800) 546-7867
Français . . . . . . . . . . . . Pages 7-11
Instalación/Operación/Piezas
Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba:
Llame al 1-800-468-7867 / 1-800-546-7867
Español . . . . . . . . . . .Paginas 12-16
©2009 SIM861 (Rev. 1/13/10)
293 Wright St., Delavan, WI 53115
Phone:
1-800-468-7867 1-800-546-7867
Fax:
1-800-390-5351
Web Site:
http://www.simerpump.com
MOD. 2300-04, 2305-04, 2310-04, 2355-04
Safety / General Information 2
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
READ AND FOLLOW
SAFETY INSTRUCTIONS!
Carefully read and follow all safety instructions in this manual and on pump.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored. The label NOTICE indicates special instructions which
are important but not related to hazards. Keep safety labels in good condition.
Replace missing or damaged safety labels.
DESCRIPTION
These Submersible Utility Pumps are designed for drain­ing water from basement floors, stock tanks, window wells, boats, flat roofs and cisterns. The units are equipped with a 3-prong grounding-type power cord. The shaded-pole motors are oil filled and sealed for cooler operation. The sleeve bearings on the motor shaft never need lubrication. Automatic reset thermal protection.
NOTICE: This unit is not designed for applications involv­ing salt water or brine! Use with salt water or brine will void warranty.
SPECIFICATIONS
Power supply required...............................115V, 60 HZ.
Liquid Temp. Range .................. Less Than 120°F (50°C)
Individual Branch Circuit Required (min.).........15 Amps
Pump Discharge:...........................................1-1/4" NPT
Adapter:..............................................3/4" Garden Hose
Risk of fire or explosion. Do not use in
explosive atmospheres. Pump water only with this pump.
NOTICE: This unit is not designed as a waterfall or foun­tain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty.
Do not use where water recirculates. Not designed for use as a swimming pool drainer.
PERFORMANCE
ELECTRICAL & SWITCH SPECIFICATIONS
GENERAL SAFETY INFORMATION
Electrically powered utility pumps normally give many years of trouble-free service when correctly installed, maintained, and used. See the “Troubleshooting Chart” in this manual for information about common utility pump problems and remedies. For more information, see your retailer, or call Simer customer service at 1-800-468-7867 or 1-800-546-7867.
1. Know the pump application, limitations, and poten­tial hazards.
2. Do not use this pump in water with fish present. If
any oil leaks out of the motor it can kill fish.
3. Disconnect the power before servicing.
4. Release all the pressure within the system before ser­vicing any component.
5. Drain all the water from the system before servicing.
6. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly caus­ing personal injury and/or property damage.
7. Check hoses for a weak or worn condition before each use, making certain that all connections are secure.
GPH (LPH) AT TOTAL FEET (M)
Model 0 5 10152025
No. (0) (1.5m) (3m) (4.6m) (6.1m) (7.6m)
CAPACITY GALLONS(L)/Hour
2300-04 2305-04
1,320 1,170 1,020 810 510
2310-04
(4,997) (4,429) (3,861) (3,066) (1,931) (–)
2355-04
2,160 1,740 1,620 1,260 720 60
(8,160) (6,600) (6,120) (4,790) (2,700) (240)
Motor Individual
Model Full Load Branch Circuit
No. HP Amps Req. (Amps)
2300-04 1/4 5.6 10 2305-04 1/4 6.0 10 2310-04 1/4 5.6 10 2355-04 1/3 10.0 15
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Installation / Operation 3
8. Periodically inspect the pump and the system com­ponents. Keep free of debris and foreign objects. Perform routine maintenance as required.
9. Provide a means of pressure relief for pumps whose discharge line can be shut-off or obstructed.
10.Personal Safety: a. Wear safety glasses at all times when working
with pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment. c. Keep visitors at a safe distance from work area. d. Make workshop child-proof – with padlocks, mas-
ter switches, and by removing starter keys.
11. When wiring an electrically driven pump, follow all of the electrical and safety codes that apply.
12.This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conduc­tor cord and 3-prong, grounding-type plug.
Hazardous voltage. Can shock, burn or
cause death. To reduce the risk of electric shock,
pull the plug before servicing. This pump has not been investigated for use in swimming pool areas. The pump is supplied with a grounding conductor and grounding-type attachment plug. Be sure it is connected only to a properly grounded grounding­type receptacle.
Where a 2-prong wall receptacle is encountered, it must be replaced with properly grounded 3-prong receptacle installed in accordance with the codes and ordinances that apply.
Do not walk on wet area until all power has been turned off. If the shut-off box is in the basement, call
the electric company or hydro authority to shutoff the service to house, or call your local fire depart­ment for instructions. Failure to follow this warning can result in a fatal electrical shock.
Do not lift the pump by the power cord.
13.All wiring should be performed by a qualified electrician.
14.Make certain the power source conforms to the requirements of your equipment.
15. Protect the electrical cord from sharp objects, hot sur­faces, oil, and chemicals. Avoid kinking the cord. Replace or repair damaged or worn cords immediately.
16.Do not touch an operating motor. Modern motors can operate at high temperatures.
17.Do not handle the pump or the pump motor, or change fuses with wet hands or when standing on wet or damp surface, or in water.
INSTALLATION
1. Set the pump on a hard surface in at least 2 inches of water.
2. Connect the discharge line with the fittings provided.
3. The pump should not be installed on clay, dirt, mud or sand surfaces. Although the pump will usually pass small particles suspended in water, clean the area to be pumped of small stones and gravel which could clog the pump.
*NOTICE: Grass, mud, sand or pea gravel can clog the pump and reduce it’s performance. Keep the pump inlet screen clean.
4. To reduce motor noise and vibrations when using rigid pipe, a short length of rubber hose (e.g. radiator hose) can be connected into the discharge line near the pump using suitable clamps.
5. Power Supply: These pumps are designed for 115 V., 60 Hz., operation and requires a minimum 15 amp individual branch circuit. Pump is supplied with a 3-wire cord with grounding-type plug.
Hazardous voltage. Can shock, burn or
cause death. Pump should always be electrically
grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire system. Do not cut off round ground pin.
6. If the pump discharge line is exposed to an outside sub-freezing atmosphere, the portion of line exposed must be installed so any water remaining in the pipe will drain to the outfall by gravity. Failure to do this can cause the water trapped in the discharge to freeze which could result in damage to the pump.
7. Check the system operation by observing the pump operation through one complete cycle.
Risk of flooding. Failure to make this operational check may lead to improper operation, premature failure, and flooding.
OPERATION
Hazardous voltage. Can shock, burn or
cause death. Do not handle a pump or pump motor
with wet hands or when standing on wet or damp sur­face, or in water.
Before attempting to check why a unit has stopped oper­ating, disconnect power from the unit.
1. The shaft seal depends on water for lubrication and cooling. Do not operate the pump unless it is sub­merged in water as seal may be damaged if allowed to run dry.
2. The pump will not remove all water. On a flat surface Model Nos. 2300, 2305, and 2310 will pump down to within 1/8" of the pumping surface. Model No. 2355 will pump down to within 5/8" of the pumping surface.
NOTICE: For long cycle times, the pump must be submerged to prevent the motor from overheating. A fully submerged pump is preferred for proper cooling when a pump runs for a long time.
AIRLOCKS
When a pump airlocks, it runs but does not move any water. An airlock will cause the pump to overheat and fail. The pumps have a built in anti-airlock hole. See Figure 1 for the location of the hole. Water leakage from the anti­airlock hole is normal.
If you suspect an airlock, unplug the pump, clean out the anti-airlock hole with a paper clip or a piece of wire, and restart the pump.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Operation 4
Troubleshooting
SYMPTOM PROBABLE CAUSE(S) CORRECTIVE ACTION
Pump won’t start or run. Pump is not plugged in. Check and see if pump is plugged in to a proper outlet.
Blown fuse. If blown, replace with fuse of proper size or reset breaker. Low line voltage. If voltage is under recommended minimum. Check size of
wiring from main switch on property. If OK, contact power company or hydro authority.
Defective motor. Replace pump.
Pump operates but Restricted discharge Remove pump and clean pump and piping. delivers little or no water. (obstacle or ice in piping).
Restricted intake. Remove the pump and clean out the intake screen. Low line voltage. The voltage is under recommended minimum. Check size of
wiring from main switch on property. If OK, contact power
company or hydro authority. Worn or plugged impeller. Replace pump. The anti-airlock hole is plugged. Turn off the pump, clean out the anti-airlock hole, and
restart the pump.
Anti-Airlock Valve (Remove screen and look under pump for access)
Roofs
3696 0500 NEW
.3
Basements
.3
Dewater flat roofs
Empty flooded rooms
Figure 1: Unsnap screen with screwdriver and tap out to clean it. Be sure all snaps catch when reinstalling it.
Figure 2:Typical uses
Repair Parts 5
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
2300-04 2305-04
Key Part Description Qty. 2310-04 2355-04
1 Power Cord (2300, 2305, 2355) 1 PS117-54-TSU PS117-54-TSU 1 Power Cord (2310) 1 PS117-36-TSU — 2 Adapter 1 HA5 HA5 3 Cover, Motor Assembly 1 ** ** 4 Inlet Screen 1 PS8-129P — 4 Inlet Screen (2305-04) 1
PS8-128P
4 Inlet Screen (2355-04) 1
PS8-127P
** If the motor fails, replace the entire pump.
Model Numbers 2300-04, 2310-04
Model Numbers 2305-04, 2355-04
1
2
3
4
5925 0109