Simer Pumps 2430 User Manual

OWNER’S MANUAL
Submersible Waterfall/Utility Pump
NOTICE D’UTILISATION
Pompe à usage général et pour chute d’eau submersibles
MANUAL DEL USUARIO
Bomba sumergibles para cascadas/de uso general
For further operating, installation, or maintenance assistance:
Call 1-800-468-7867
English . . . . . . . . . . . . . . . Pages 2-6
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,
Composer le
1 (800) 468-7867
Français . . . . . . . . . . . . Pages 7-11
Instalación/Operación/Piezas
Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba:
Llame al 1-800-468-7867
Español . . . . . . . . . . .Paginas 12-16
253P6030 (Rev. 1/21/08)
Mod. 2430
293 Wright St., Delavan, WI 53115
Phone:
1-800-468-7867 1-800-546-7867
Fax:
1-800-390-5351
Safety 2
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored. The label NOTICE indicates special instructions which
are important but not related to hazards.
GENERAL SAFETY
Carefully read and follow all safety instructions in this manual and on pump.
Keep safety labels in good condition. Replace missing or damaged safety labels.
To avoid serious injury and/or property damage, read and follow these rules and instructions carefully.
Risk of electric shock. Can burn or kill.
This pump only for use in portable, self-contained foun­tains no larger than 5 feet in any dimension.
1. Pump is designed for use with clean, cold, fresh
water. Pump water only with this pump.
2. Do not lift pump by power cord at any time.
Attempting to lift or support the pump by the power cord can damage the cord and cord connections, and will void warranty. Always lift the pump by the lifting handle.
3. Meet National Electrical Code, Canadian Electrical
Code, and local codes for all wiring. The National Electric Code requires installation of a ground fault circuit interrupter (GFCI) in the branch circuit supply­ing fountain pumps and other pond equipment. Purchase a GFCI at your local electrical supply dealer.
4. Installation must comply with all local codes
pertaining to outdoor waterfall, fountain, pond and utility pumps.
5. Know the pump application, limitations, and
potential hazards.
6. Disconnect the power before servicing.
7. Release all pressure within the system before servic­ing any component.
8. Drain all water from the system before servicing.
9. Secure the discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.
10. Check hoses for weak or worn condition before each use, making certain that all connections are secure.
11. Periodically inspect the pump and system compo­nents. Keep the pump inlet free of debris and foreign objects. Perform routine maintenance as required.
12. Personal Safety: a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment. c. Keep visitors at a safe distance from work area. d. Make workshop child-proof – with padlocks, mas-
ter switches, and by removing starter keys.
13. This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conduc­tor cord and 3-prong, grounding-type plug.
Hazardous voltage. Can shock, burn or
cause death. T
o reduce risk of electric shock, pull plug before servicing. This pump has not been investigated for use in swimming pool areas. Pump is supplied with a grounding conductor and grounding-type attachment plug. Be sure it is connected only to an individual branch circuit with a properly grounded grounding-type receptacle. Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle installed in accordance with codes and ordinances that apply.
14. Make certain power source conforms to requirements
of your equipment.
15. Protect the electrical cord from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.
16. Do not touch an operating motor. Motors can operate
at high temperatures.
17. Do not handle pump or pump motor with wet hands
or when standing on wet or damp surface, or in water.
Table of Contents 3
Thank you for purchasing a top quality, factory tested pump.
Page
General Safety .....................................................................................................2
Warranty..............................................................................................................3
General Information.............................................................................................4
Installation ...........................................................................................................5
Operation ............................................................................................................5
Maintenance........................................................................................................6
Troubleshooting ...................................................................................................6
SIMER warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below. Your origi­nal receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any Pre-Charge water system tank shall prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below.
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of SIMER, have been subject to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other than normal application, use or service, including but not limited to, operational fail­ures caused by corrosion, rust or other foreign materials in the system, or oper­ation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defec­tive product to the Retail outlet or to SIMER as soon as possible after the dis­covery of any alleged defect. SIMER will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive rem­edy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or conse­quential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Simer Limited Warranty
SIMER • 293 Wright St. • Delavan, WI U.S.A. 53115
Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351
General Information 4
DESCRIPTION
This submersible pump is designed for use as a waterfall/fountain or as a utility pump. The unit is equipped with a 3-prong grounding-type power cord. Ball bearings on the motor shaft never need lubrication. Automatic reset thermal protection.
SPECIFICATIONS
Power supply required..................................115V, 60 HZ.
Motor duty .....................................................Continuous*
Liquid temperature range ...............32°F to 77°F (0°-25°C)
Individual branch circuit
requirement (minimum) .......................................15 Amps
* For continuous operation the water depth must be at least 5” (13 cm) to prevent the motor from overheating.
NOTICE: Not designed for applications involving salt water or brine! Use with salt water or brine will void warranty.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
GPH (LPH) AT TOTAL FEET (M) No Flow
Motor 0 5 10 15 20 At Height
Model HP (0 m) (1.5 m) (3 m) (4.6 m) (6.1 m) Shown Below
2430 1/3 2,400 (9,085) 1,920 (7,628) 1,380 (5,224) 780 (2,953) 240 (908) 22’ (6.7 m)
PERFORMANCE
Motor Minimum Pumps
Motor Full Load Circuit Down
Model H.P. Amps Req. (Amps) To
2430 1/3 2.3 15 7/8” (22 mm)
Pump
Model No. Included Adapters
1-1/4” FNPT x 1-1/4”
2430
Hose Barb Elbow (P/N 007-022)
1-1/4” FNPT x 3/4”
Garden Hose Fitting (P/N ZA000900)
DISCHARGE FITTINGS CHART
ELECTRICAL SPECIFICATIONS
Installation / Operation 5
INSTALLATION
1. Install the pump on a hard level surface. Make sure that the pump cannot pick up rocks, mud and debris, etc. If neccesary, put a block under the pump to raise it slightly. See Figure 1.
2. Protect the power cord from damage. Uncovered cords should be routinely inspected for damage or deterioration. DO NOT operate the pump if the cord is damaged.
3. Choose an adapter and install it as indicated in Figure 2.
OPERATION
Hazardous voltage. Can shock, burn or
cause death. Do not handle a pump or pump motor with
wet hands or when standing on a wet or damp surface, or in water.
1. The shaft seal depends on water for lubrication. Do not operate the pump unless it is in water as the seal may be damaged if allowed to run dry.
2. The motor is equipped with an automatic reset ther­mal protector. If the temperature in the motor should rise unduly, the switch will cut off all power before damage can be done to the motor. When the motor has cooled sufficiently, the switch will reset automati­cally and restart the motor. If the protector trips repeatedly, remove the pump and check it as to the cause of difficulty. Low voltage, long extension cords, clogged impeller, very low head or lift, etc., could cause cycling.
3. The pump will not remove all water. If the pump is operating and suddenly no water comes out of the discharge hose, shut off the unit immediately. The water level is probably very low and the unit has bro­ken prime.
NOTICE: For continuous operation, water must flow through pump to prevent motor overheating. The pump is cooled by the water flow through the housing.
4. This pump is designed to pump cold water only. Pumping heated liquids can overheat the motor and cause the thermal overload to trip.
5. Pump can run when water doesn’t completely cover the motor housing, but the inlet must be completely submerged or it will break suction, will not move any water, and may damage the shaft seal. NOTICE: For continuous operation the water depth must be at least 5” (13 cm) to prevent the pump from overheating.
6. Keep the pump inlet clean at all times. If the ground bottom or surface where the pump sits is dirty, raise the pump slightly to reduce the amount of debris pulled into the pump inlet.
7. If you need to reduce the flow, restrict the discharge. Do not restrict the intake. Doing so will starve the pump for water and can cause overheating.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Figure 1: Typical garden pond and waterfall installation.
Figure 2: Adapter connections.
GFCI Outlet
Power cord
Landscaping rocks
Use foliage to cover tubing to waterfall
Raise the pump off of the bottom of the pond
Plastic tubing to waterfall
3388 0399 NOC 6030
1-1/4" FNPT X 3/4" Garden Hose Fitting
1-1/4" X 1-1/4" Hose Barb Elbow
Loading...