Sierra S5020, S5022, S5021 Using Manual

Page 1
Using Your
Security System
With Icon Keypad S5020, S5021, S5022
Page 2
Contents
Your Security System................................. 1
How Your Security System Works.............. 2
Your System's Programming...................... 3
Getting Used to Your System..................... 3
The Parts of Your Keypad.......................... 4
Understanding the Icon Messages.............. 5
System Status Messages.......................... 6
Emergency Keys........................................ 7
---------
2 User Codes and Privileges
User Codes and User Numbers.................. 8
Selecting the Right User Number................8
How to Enter a User Code.......................... 9
Correcting a User Code Entry..................... 9
How to Assign or Change User Codes .......10
How to Delete a User Code.........................11
Types of User Codes ..................................12
Master User Code ...................................... 12
Basic User Code......................................... 12
Duress Code............................................... 13
Relay Code..................................................13
Kidwatch Code............................................ 14
Maid Code...................................................16
Temporary Maid Code ............................... 17
---------
3 Arming and Bypassing
How the Arming Modes Differ..................... 18
Quick Arming Modes .................................. 18
Exit Delays................................................. 19
Canceling an Arming Sequence................. 19
Full Arming................................................. 20
Quick Full-Arming....................................... 20
Home Arming.............................................. 21
Quick Home-Arming................................... 21
Page 3
Instant Home-Arming................................. 22
Quick Instant Home-Arming....................... 22
Automatic (Timed) Arming.......................... 23
Arming with Not-Ready Zones.................. 25
Bypassing................................................... 26
Quick Bypassing......................................... 27
Optional Arming Features........................... 28
---------
4 Disarming and Alarms
Entry Delays............................................... 30
Disarming................................................... 30
Canceling an Alarm.................................... 31
After an Alarm............................................. 31
Automatic (Timed) Disarming..................... 32
How to Prevent False Alarms..................... 34
Optional Alarm Features............................. 35
---------
5 System Settings
How to Set the Clock and Calendar........... 36
How to Turn the Warning Tone On/Off....... 38
How to Turn the Chimes On/Off................. 38
How to Turn the Backlight On/Off............... 39
How to Change the Relay 1 Days............... 40
How to Change the Relay 2 Days............... 41
How to Change the Relay 3 Days............... 42
How to Change the Relay 4 Days............... 42
---------
6 System Maintenance
How to Walk-Test the System.................... 43
How to Use Event Memory......................... 44
How to Test the Bells and Sirens................ 47
To Start a Remote Programming Session.. 48
Page 4
How to Test the Battery.............................. 49
Common System Messages...................... 50
Troubleshooting Service Conditions........... 51
U
---------
7Partitioning
What Areas Do.......................................... 53
How Areas Affect User Codes.................... 55
Pre-Assigned User Numbers...................... 56
Changing Area User Codes....................... 56
How Areas Affect the System..................... 57
U
---------
8 Notes
System Configurations............................... 58
Glossary of Terms...................................... 61
Page 5
1
1
Overview
Your Security System
Your security system includes a number of detection devices, such as magnetic contacts, glassbreak detectors, smoke detec- tors, and motion sensors. These devices identify alarm condi- tions and report them to the control panel. If programmed, the control panel sounds an alarm. The control panel also communi­cates with you (through the keypad) and with a monitoring sta- tion (through a telephone hook-up).
Each region monitored by a sensor (or group of sensors) is known as a zone. Most zones will trigger an alarm only when the sys­tem is armed. Other sensors, such as smoke detectors, can trig­ger an alarm at any time. Your system's zones are identified on a label placed inside the door of your keypad.
Monitoring station personnel respond to system messages, and notify emergency personnel as needed. A monitoring service is an optional part of a security system.
Smoke Detector
Motion Sensor
(Interior Protection)
ZONE
ZONE
ZONE
Magnetic Contact
Glassbreak Detector
(Perimeter Protection)
Keypad
CONTROL
PANEL
Siren (Alarm)
Monitoring Station
Page 6
2
1
Overview
How Your Security System Works
When an intruder enters the building, a detection device is trig­gered. The device sends a message to the control panel. The device may have LEDs (lights) that blink.
The control panel responds by sounding the alarm. (Alarm sounds vary. If your system is programmed for silent alarms, no bells or sirens sound.) A message is sent to the keypad and, if connected, to the monitoring station.
The keypad displays a warning message. Personnel at the moni­toring station confirm the alarm and respond accordingly.
Some alarms can be canceled before the siren sounds and the monitoring station is notified. See Section 4 for more information.
Intruder
Sensor
Triggers Alarm
CONTROL
PANEL
Siren
Sounds Alarm
Keypad
Issues Warnings
Monitoring
Station Is Notified
Page 7
3
1
Overview
Your System's Programming
Your Sierra security system has been customized to suit your needs. Besides selecting the best equipment for your building, your installer has programmed your system to operate in a way that reflects your lifestyle. For example, your system may be pro­grammed to recognize special user codes, to arm and disarm automatically, or to report to a monitoring station.
Throughout this manual, you will find descriptions of features that may have been programmed into your system. To see how your system was programmed, refer to the checklist in Section 8.
Getting Used to Your System
Your security system can be programmed for a learning period that can last from one to 31 days. With this option, you can prac­tice using your system without causing any false alarms. Refer to Section 8 to see if this learning period was programmed into your system.
During the learning period, your system does two things differ­ently. First, during an alarm, you do not hear any sirens or bells. Second, if you have a monitoring station hook-up, your system does not notify the station of an alarm.
After the learning period is over, your system automatically be­gins to function normally. If programmed, sirens and bells sound during an alarm, and the monitoring station receives information over the telephone hook-up.
IMPORTANT: Your building is not completely protected from ac­tual alarms during the learning period.
Page 8
4
1
Overview
Arm LED
The Parts of Your Keypad
Power LED
If this LED... Is on: Is off: Is blinking:
Power The power supply
is normal.
The system is drawing power from the battery.
The battery is low.
Numeric Keys
Used to enter codes and perform other functions
Icon Display
Describes the system's status
Numeric Display
Communicates numeric information, such as the number of the zone in alarm
Secondary Function Keys
Used to make user­controlled changes to the system.
Arm The system is
armed.
The system is disarmed.
The system is about to arm.
Understanding the Lights (LEDs)
Emergency Keys
Used to report a medical, fire, or police emergency.
Page 9
5
1
Overview
Understanding the Icon Messages
Your icon keypad communicates information by lighting the words and phrases in the icon display. The words that make up a mes­sage may be on different lines, or separated by other words.
For example, you may see the following message in your display:
This message indicates that Zone 4 is not ready to arm.
In this manual, you will see messages such as these presented on one line, such as this:
ZONE # NOT READY
Number symbols ("#") substitute for the specific numeric informa­tion your system displays.
Page 10
6
1
Overview
System Status Messages
The display of your icon keypad gives you information about the status of your system. If there is more than one condition to re­port, your display switches between the messages.
Below is a list of the types of messages you might see. On your display, the # symbol is replaced with the number of the zone (or zones) in question. For more information about many of these messages, see Section 6.
READY. The system is ready to be armed.
READY ALARM ZONE #. The system is ready to be armed;
however, the system's alarm memory contains a record of an alarm. To clear the alarm memory, press and hold the key for two seconds.
READY BYPASS ZONE #. The system is ready to be armed; however, the zone listed is bypassed, and therefore, not pro­tected. If more than one zone is bypassed, the numbers of the zones are sequentially displayed.
NOT READY ZONE #. The system is not ready to be armed. The zone number listed is faulted. (The zone may be faulted if, for example, a door is ajar or a window is open.) If more than one zone is faulted, the numbers of the zones are se­quentially displayed.
NOT READY TAMPER ZONE #. The system is not ready to be armed. The zone listed has been tampered with. If more than one zone has been tampered with, the numbers of the zones are sequentially displayed.
Page 11
7
1
Overview
Emergency Keys
Your keypad is equipped with three emergency keys. The
keys do not function unless your installer activated them.
If activated, these keys are a one-button way to inform your monitoring station of a medical emergency, a fire, or a crime in progress.
Depending upon how your sys­tem is programmed, an alarm may sound when an emer­gency key is pressed. To can-
cel the alarm, press the
key, then enter your
user code.
After you press an emergency key, your keypad's display shows that an emergency alarm occurred. To clear the display, press and hold the
key for two seconds
until you hear two beeps.
To Use Emergency Keys:
1. To report a medical emer­gency, press and hold the
key for 2 seconds
until you see:
E
2. To report a fire, press and hold the key for 2 seconds until you 2 seconds until you see:
F
3. To report a crime in progress, press and hold the key for 2 seconds until you 2 seconds until you see:
P
System Status Messages (continued)
NOT READY TROUBLE ZONE #. A sensor in the zone number listed may need service.
Page 12
2
User Codes
8
User Codes and User Numbers
A user code is a secret four-digit number, used to arm and dis- arm the system, and possibly to make other changes. Every indi­vidual who has a user code is also assigned a two-digit user num- ber. You cannot assign the same user code to more than one user number.
You can assign a different user code and user number to each person who operates the system. Your security system supports up to 60 users.
If you prefer, you can assign only one user code and user number to a group of users. This is not recommended, since it will then be impossible to determine which individual gave a specific com­mand.
Selecting the Right User Number
At installation, each user number is assigned rights and privileges. For example, user number 18 may have the rights to arm, disarm, and bypass zones. This is true even if, in this example, there is no user 18 using the system.
Thus, if you want to assign a user code to a new user, be sure
that you select a user number with the privileges you want that user to have. Your installer should have provided you with spe-
cific information about how your system was configured. Refer to this information to select the proper user number.
Page 13
2
User Codes
9
You will know that you entered an incorrect code when the sys­tem does not complete your command. As a security fea­ture, your keypad does not beep when you enter an incor­rect user code.
If you make a mistake entering the code, simply re-enter your user code.
How to Enter a User Code
To enter a user code, simply press the four numbers in succes­sion. Do not pause for more than five seconds between num­bers. For security reasons, the code you enter is not displayed.
To Correct a User
Code Entry:
1. Re-enter your user code.
Correcting a User Code Entry
Page 14
2
User Codes
10
How to Assign or Change User Codes
To Assign or Change
a User Code:
1. Press and hold the [user prg] key for 2 seconds until you hear two beeps. You see:
ENTER MASTER CODE
Enter the master user code. The first available user num­ber is shown.
2. To select another user num­ber, enter that two-digit num-
ber and press
. If a
user code has been assigned to this number, it is displayed, one number at a time.
3. Enter the new 4-digit user code. As you enter each of the 4 numbers of the code, the keypad draws the four sides of a square and beeps twice.
User codes can be created or changed as often as you like. Any code you select must be four numbers long.
You cannot use 0000, or assign the same code to more than one user number. Avoid codes that are easy to guess, like
1234. The default master user code (user number 1) is 5832. For security reasons, be sure to change this code. Do not as­sign the code 5832 to another user.
If you make a mistake while assigning a user code, you may correct it by repeating the pro­cedure.
You may stop the procedure at any time by jumping ahead to the final step (namely, pressing and holding the
key for
two seconds.
Be sure to record the user codes, and to keep these records in a safe place.
Page 15
2
User Codes
11
How to Delete a User Code
You may delete a code by changing that code to 0000. Follow the procedure for as­signing or changing a user code.
To Delete a User Code:
1. Change the user code to 0000, following the proce­dure for assigning or chang­ing a user code.
Some security systems include wire­less keyfobs and remotes, used to arm and disarm the system. If a keyfob or remote is lost, you can pro­tect your building by deleting its as­signed user code.
TIP
Assign or Change User Codes (continued)
To Assign or Change
a User Code (continued):
4. To exit, press and hold the key for 2 seconds
until you hear two beeps.
Page 16
2
User Codes
12
Depending upon how your system was programmed, basic users may have rights to arm, disarm, or bypass zones.
Basic User Code
Standard Code _X_
Optional Code ___
Active Certain Days/Times ___
Types of User Codes
This section identifies the types of user codes your system may recognize. At the top of each user code section, you will see a checklist like this:
Items on this checklist followed by an "X" are features of the user code.
The master user can arm and disarm the system, and can make other changes, such as disabling your system's features, and changing user codes.
Master User Code
Standard Code _X_
Optional Code ___
Active Certain Days/Times ___
Standard Code _X_
Optional Code ___
Active Certain Days/Times ___
Page 17
2
User Codes
13
If an intruder forces you to dis­arm your system, this optional code sends a silent signal to alert monitoring station person­nel that you are in danger.
For systems without multiple areas, the code is assigned to user number 15. You can change or delete this code like any other user code.
Standard Code ___
Optional Code _X_
Active Certain Days/Times ___
Duress Code
A relay code acts like a switch. When you enter this code, a device that is connected to the control panel is turned on or off. For example, your system can be programmed to switch the ex­terior lights of your building on or off when you enter a relay code. Relay codes must be programmed into your system by the in­staller.
The relay code is a four-digit code that you can change or delete like any other user code. If you delete the relay code, you will no longer be able to use this feature. For systems without multiple areas (as described in Section 7), the code is assigned to user number 14.
Relay Code
Standard Code ___
Optional Code _X_
Active Certain Days/Times _X_
To Use the Duress Code:
1. Enter the four-digit code.
Your system appears to dis­arm normally. However, a message is sent to your moni­toring station that you are in danger.
Page 18
2
User Codes
14
Kidwatch Code
Standard Code ___
Optional Code _X_
Active Certain Days/Times _X_
To Change Kidwatch Days :
1. Press and hold the [kidwatch] key for 2 seconds until you hear two beeps. When prompted, enter the master user code.
You see something like this:
-2-
The three spaces in the nu­meric display represent the first three days of the week (Sunday-Tuesday). If a space contains a dash, use of the code is not monitored on that day. Thus, in the example above, the code is monitored on Monday and not moni­tored on Sunday and Tues­day.
3. To view the remaining days of the week, press the
key. Each time you
Designed for parents whose children come home first, this option allows you to be notified if your child is not home by a certain time. You can be noti­fied by pager, by an automated telephone call, or by your moni­toring station. (Not all monitor­ing stations offer this service.)
The Kidwatch Code is a four­digit code that you can change or delete like any other user code. The code is assigned to user number 11. It allows your children to disarm the system, and can be programmed to al­low them to arm or bypass zones.
How it works. After arriving home, during a day when Kidwatch is active, your chil­dren disarm the system by en­tering the Kidwatch Code. If they do not enter the code by a given time, you are notified.
(continued)
Page 19
2
User Codes
15
Changing Kidwatch Days.
You have the option of chang­ing which days Kidwatch is in effect. To do so, follow the pro­cedure on the previous page.
Reviewing Kidwatch Use.
You can review the times that Kidwatch Codes were used to arm and disarm your system by viewing Event Memory. See Section 6 for more information.
Turning Kidwatch on and off.
Kidwatch can be turned on and off. When Kidwatch is turned off, you are no longer notified of the use of the Kidwatch Code. Otherwise, the code works as before. If you turn Kidwatch on or off, it remains that way until you change it back.
Kidwatch Setup. See Section 8 for the specifics of how the Kidwatch Code was set up on your system.
To Change Kidwatch Days
(continued):
press the
key, the dis-
play moves forward one day.
4. To change the days that the Kidwatch Code is monitored, enter the number of the day you wish to change. To exit press the
key.
To Turn Kidwatch On/Off
1. Press and hold the [kidwatch] key for 2 seconds until you hear two beeps. En­ter the master user code.
2. Press the
key five
times. Press the
key
until you see:
--8
3. To exit press the key.
Page 20
2
User Codes
16
Maid Code
Standard Code ___
Optional Code _X_
Active Certain Days/Times _X_
(continued)
Unlike other user codes, which work any day of the week, the Maid Code works only on cer­tain days of the week.
The Maid Code is a four-digit user code that you can change or delete like any other user code. Your installer must have programmed your system to accept a Maid Code. For sys­tems without multiple areas (as described in Section 7), the code is assigned to user num­ber 13. It allows an individual to arm and disarm the system on specific days or for limited periods of time.
How it works. Arriving at the building during a day when the Maid Code is active, the maid can disarm the system by en­tering the Maid Code. Upon leaving the building, the maid can arm the system by enter­ing the same code.
To Change Maid Days :
1. Press and hold the [maid] key for 2 seconds un-
til you hear two beeps. Enter the master user code.
You see something like this:
-2-
The three spaces in the nu­meric display represent the first three days of the week (Sunday-Tuesday). If a space contains a dash, the code is does not work on that day. If the space contains a number, the code works on that day. Thus, in the example above, the code works on Monday and does not work on Sunday and Tuesday.
3. To view the remaining days of the week, press the
Page 21
2
User Codes
17
Maid Days and Times. For the specifics of how the Maid Code was set up on your system, see Section 8.
To Change Maid Days
(continued):
key. Each time you press the key, the dis­play moves forward one day.
4. Press the number of the day you wish to change. To exit,
press the
key.
Temporary Maid Code
Standard Code ___
Optional Code _X_
Active Certain Days/Times _X_
As the preceding section shows, the Maid Code can be programmed to work on certain days of the week only. If you prefer however, you can set the Maid Code to work for the next few hours, regardless of the day of the week. The number of hours the Maid Code works depends upon your system's programming. (See Section 8.)
The Temporary Maid Code is assigned to user 13.
To Start the Maid Code Timer:
1. Press and hold the [maid] key for 2 seconds un-
til you hear two beeps. Enter the master user code.
2. Press the
key five times. Press the key until you see:
--8
3. To exit press the key.
Page 22
3
Arm/ Bypass
18
How the Arming Modes Differ
Your security system can be armed in a number of ways, to suit different situations. These modes are summarized below.
Full Arming. You cannot be inside the building when it is armed with full-arming. If sensors detect movement within a building, or at the buildings perimeter, an alarm sounds.
Home Arming (optional). You can be inside the building when it is armed with home-arming. If someone enters the building through a protected door, you must enter a user code, or an alarm sounds.
Instant Home-Arming (optional). You can be inside the building when it is armed with instant home-arming. If some­one enters the building through a protected door, an alarm sounds instantly.
Automatic Arming (optional). Your system can be pre-pro­grammed to arm and disarm at preset times and days. You cannot be inside the building when it is automatically armed.
Quick Arming Modes
If your system is programmed for quick arming, you do not need to enter your user code before arming begins.
Quick arming does not affect how your system behaves once it is armed. For example, there is no difference in the way a system armed with home-arming or quick home-arming protects you.
Page 23
3
Arm/ Bypass
19
Exit Delays
An exit delay is the amount of time you have to exit and secure the building, once your security system begins to arm. These delays may last from 20 to 255 seconds, depending upon how your system is programmed.
During the exit delay, the Arm LED blinks. The keypad display counts down the seconds remaining in the exit delay. The key­pad may beep; if so, it beeps faster during the last ten seconds.
Any arming command with an exit delay may be canceled be­fore the system is armed. To cancel an arming sequence, enter a user code during the exit delay.
To Stop an Arming
Sequence:
1. Enter your user code.
Canceling an Arming Sequence
Page 24
3
Arm/ Bypass
20
When your system is armed with full arming, both the perim­eter and interior zones are armed. You are allowed a set time to enter or exit the build­ing before an alarm sounds.
See Section 8 for the entry and exit delay settings programmed into your system.
To Arm the System With Full-Arming:
1. Make sure the display reads:
READY
Enter your user code. Exit and secure the building.
Full Arming
Interior armed _X_
Perimeter armed _X_
Exit allowed _X_
Requires user code _X_
Automatically arms ___
No entry allowed ___
Quick Full-Arming.
If your system is pro­grammed for quick full­arming, you do not need to enter a user code.
To Arm the System with
Quick Full-Arming:
1. Press and hold the [quick exit] key for 2 seconds
until you hear 2 beeps. Exit and secure the building.
Page 25
3
Arm/ Bypass
21
With home arming, you can re­main inside a building while its perimeter zones (such as doors and windows) are armed. No alarm sounds if a sensor de­tects movement within the building.
Your system might be pro­grammed for a home arming exit delay option (see Section
8.) This means that one or more individuals can leave the building during the exit delay.
At the end of the exit delay, only the perimeter zones are armed.
Quick Home-Arming.
If your system is pro­grammed for quick home-arming, you do not need to enter a user code.
Home Arming
Interior armed ___
Perimeter armed _X_
Exit allowed _X_
Requires user code _X_
Automatically arms ___
No entry allowed ___
To Arm the System
With Home Arming:
1. Make sure the display reads:
READY
Press the key. You see:
ENTER CODE
2. Enter your user code. If your system is programmed with an exit delay, you can now leave.
To Arm the System with
Quick Home Arming:
1. Press and hold the key until you hear 2 beeps. If your system is pro­grammed with an exit delay, you can now leave.
Page 26
3
Arm/ Bypass
22
Interior armed ___
Perimeter armed _X_
Exit allowed ___
Requires user code _X_
Automatically arms ___
No entry allowed _X_
Instant Home-Arming
With instant home-arming, an alarm sounds the instant a sen­sor on the building's perimeter detects a problem. The interior sensors are not armed.
Before anyone can open a pro­tected door or window, the sys­tem must first be disarmed.
To prevent false alarms, use in­stant arming only when you are sure no system user will open a protected door or window.
Quick Instant Home­Arming. If your system
is programmed for quick instant arming, you do not need to en­ter a user code.
To Arm the System with
Instant Home-Arming:
1. Make sure the display reads:
READY
Press and hold the [instant] key for 2 seconds until you hear 2 beeps. You see:
ENTER CODE
2. Enter your user code. The Arm LED blinks and the key­pad beeps twice. Your sys­tem is immediately instant home-armed.
To Arm the System with
Quick Instant Home-Arming:
1. Press and hold the [instant] key for 2 seconds until you hear 2 beeps. Your system is immediately instant home-armed.
Page 27
3
Arm/ Bypass
23
Automatic (Timed) Arming
Interior armed _X_
Perimeter armed _X_
Exit allowed _X_
Requires user code _X_
Automatically arms _X_
No entry allowed ___
To Change Automatic-
Arming Days:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. Enter the master user code.
2. Press the
key six
times until you see:
--7
3. Press the key. You see something like this:
-2-
The three spaces in the nu­meric display represent the first 3 days of the week (Sun­day-Tuesday). If a space contains a dash, Automatic Arming is disabled (off) for that day. If the space contains a number, Automatic Arming is enabled (on).
Your system can automatically arm itself at pre-set times of the day. This option must be pro­grammed into your system by your installer.
At two minutes and again at one minute before the Automatic Arming sequence begins, the siren sounds. Then, the exit de­lay begins. You must leave the building during the exit delay, or an alarm sounds.
You can postpone the Auto­matic Arming sequence by one hour. When the siren sounds two minutes before arming oc­curs, press the
key,
then enter your user code.
You can change the days that Automatic Arming occurs by following the procedure to the right. To stop Automatic Arm­ing, turn off all of the Automatic Arming days. To change the times that arming occurs, con­tact your installer.
Page 28
3
Arm/ Bypass
24
Thus, in the example shown, the code is enabled on Mon­day and disabled on Sunday and Tuesday.
4. To view the remaining days, press the number above the day of the week, press the
key. Each time you press the key, the dis­play moves forward one day.
5. To change the days that Au­tomatic Arming is in en­abled, enter the number of the day you wish to change.
6. To exit, press the key.
To Change Automatic-
Arming Days (continued):
Automatic Arming (continued)
Page 29
3
Arm/ Bypass
25
Arming With Not-Ready Zones
The zones in your system are not always ready to arm. For ex­ample, a zone would not be ready to arm if one of its sensors has been vandalized, needs service, or detects a potential alarm condi­tion. Zones which are not ready to arm are referred to as not-ready zones.
Your system has been programmed to automatically handle not-ready zones in one of three ways described below. Refer to Section 8 to see how your system was programmed.
Force Arming. With Force Arming, the system arms, even if some not-ready zones exist. All not-ready zones are ignored (bypassed) and therefore, not protected. Exception: Any faulted Day Buzzer or Day Bell zones must be manually bypassed be­fore arming can occur. These are zones that cause a buzzer or bell to sound if they are faulted while the system is disarmed.
Chirp-Alert Arming. With Chirp-Alert Arming, your system does not arm if a not-ready zone exists. At the end of the exit delay, your system's sounders chirp. You must re-enter the building and enter a user code, or an alarm sounds. Then, you must either correct or manually bypass these zones before the sys­tem can be armed.
Goof-Proof Arming. With Goof-Proof Arming, the system does not arm if there are any not-ready exit zones (doors). Instead, an alarm sounds at the end of the exit delay. You must re-enter the building and correct the not-ready zones before arming can occur.
Page 30
3
Arm/ Bypass
26
When you manually bypass a zone, your security system functions as if that zone does not exist. Bypassed zones
are not protected.
NOTE: Depending upon your system's programming, you may not be able to bypass all of the zones in your system.
Restoring bypassed zones. If you manually bypass a 24­hour zone, such as a glassbreak detector, that zone remains bypassed until you re­store it. However, if you manu­ally bypass a zone that is not a 24-hour zone, it is restored when you disarm the system.
Bypassing
To Bypass a Zone:
1. When a zone is faulted, the display reads:
ZONE# # NOT READY
2. To bypass the zone, press the
key. You see:
ENTER BYPASS ZONE#
3. Enter the two-digit zone number. (For zones 1-9, en­ter a "0" first.) You see:
ENTER CODE
4. Enter your user code.
To Restore a Bypassed Zone:
Repeat the procedure above. The zone operates normally.
Page 31
3
Arm/ Bypass
27
Quick Bypassing
Quick bypassing allows you to bypass zones without entering a user code. This option must be programmed into your sys­tem by the installer. With quick bypassing, any user can by­pass any bypassable zone.
IMPORTANT: If your system is programmed for quick bypass­ing, anyone can bypass your system's zones. Since by­passed zones are not pro­tected, this feature increases the likelihood that your system may be defeated.
To Bypass a Zone with Quick
Bypassing:
1. When a zone is faulted, the display reads:
ZONE# # NOT READY
2. To bypass the zone, press the
key. You see:
ENTER BYPASS ZONE#
3. Enter the two-digit zone number . (For zones 1-9, enter a "0" first.)
To Restore a Bypassed Zone
with Quick Bypassing:
Repeat the procedure above. The zone operates normally.
Page 32
3
Arm/ Bypass
28
Optional Arming Features
Your system offers the optional arming features described below. Refer to Section 8 to see which features are installed on your system.
Extended Exit Delay. This feature automatically resets the exit delay if you re-enter the building while the system is being armed. You may re-enter four times; each time, the exit delay is reset to its full value.
Keypad Lockout. Designed to prevent an intruder from guess­ing a user code, this option causes the system to slow down if a series of invalid user codes are entered. Before a new user code can be entered, the user must wait through a delay. The delay lengthens as more invalid codes are entered. Depending upon your system's programming, the keypad lockout may not affect arming.
Keyswitch Arming. This accessory (Sierra S5051) allows you to arm and/or disarm the system with a key. Follow the instruc­tions on the switch.
Quick Exit. This option allows you to exit a home-armed building without disarming and re-arming. To start the exit delay, press and hold the
[quick exit] key for 2 seconds until you hear two beeps. Enter your user code, then exit. (Depending on your system's programming, a user code may not be needed.)
Exit Termination. This option allows you to shorten the exit de­lay to the last five seconds by pressing a button located near your exit.
Page 33
3
Arm/ Bypass
29
Optional Arming Features (continued)
Automatic Home-Arming. Automatic Home-Arming allows you
to remain inside a building while its perimeter zones (such as doors and windows) are armed. Arming begins by entering your user code. If you exit the building during the exit delay, the sys­tem arms both the interior and perimeter zones (full arming). How­ever, if you do not exit the building, the system automatically arms the perimeter zones only (home arming).
Page 34
4
30
Disarm/Alarms
Entry Delays
Similar to an exit delay, an entry delay is the time you are allowed to enter the building, walk to the keypad, and enter a user code before an alarm sounds. This delay lasts from 10 to 255 sec­onds, depending on your system's programming. The length of the delay may differ, depending on which door you use.
During the entry delay, the Arm LED blinks. The keypad may beep during the delay. If so, it beeps faster during the last ten seconds. The numeric display counts down the number of sec­onds remaining in the entry delay.
During the entry delay, the ENTER CODE icons are lit, to remind you of the procedure to disarm the system.
Disarming
To Disarm the System:
1. Enter through a door pro­grammed with an entry delay.
2. Enter your user code.
Regardless of which method was used to arm your system, the disarming sequence is al­ways the same.
Be sure that the door you use to enter the building has been programmed with an entry de­lay.
Page 35
4
31
Disarm/Alarms
Canceling an Alarm
To Cancel an Alarm:
1. You see:
ALARM ZONE ## ENTER CANCEL
2. Press the key. You see:
ENTER CODE
3. Enter your user code.
If programmed, your system may pause briefly before sounding an alarm. This gives you the opportunity to cancel a false alarm. You can cancel the alarms of any sensor, including a smoke detector.
The amount of time you have to cancel the alarm depends upon how your installer pro­grammed the system. See the "Cancel Alarm Time" listing in Section 8. Your keypad may beep to warn you that an alarm is about to occur.
Five seconds after an alarm is canceled, your system reverts to normal.
After an Alarm
You should reset your system after an alarm. This action clears your keypad's display and resets your sensors.
To Reset After an Alarm:
1. Press and hold the key for 2 seconds until you hear 2 beeps.
Page 36
4
32
Disarm/Alarms
Automatic (Timed) Disarming
Interior armed _X_
Perimeter armed _X_
Exit allowed _X_
Requires user code _X_
Automatically arms _X_
No entry allowed ___
To Change Automatic-
Disarming Days:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. Enter the master user code.
2. Press the
key until
you see:
--8
3. Press the key. You see something like this:
-2-
The three spaces in the nu­meric display represent the first 3 days of the week (Sun­day-Tuesday). If a space contains a dash, Automatic Disarming is disabled (off) for that day. If the space con­tains a number, Automatic
Your system can automatically disarm itself at preset times of the day. This option must be programmed into your system by your installer.
You can change the days that Automatic Disarming occurs by following the procedure to the right. To change the times that disarming occurs, contact your installer.
(continued)
Page 37
4
33
Disarm/Alarms
Disarming is enabled (on).
Thus, in the example shown, the code is enabled on Mon­day and disabled on Sunday and Tuesday.
4. To view the remaining days, press the number above the day of the week, press the
key. Each time
you press the
key, the display moves forward one day.
5. To change the days that Au­tomatic Disarming is in en­abled, enter the number of the day you wish to change.
6. To exit, press the
key
twice.
To Change Automatic-
Disarming Days (continued):
Automatic Disarming (continued)
Page 38
4
34
Disarm/Alarms
How to Prevent False Alarms
False alarms are more than a nuisance—they reduce the reliabil­ity of your security system. Here are a few steps you can take to prevent the annoyance and expense of false alarms.
1. Know your system. Make sure all system users under­stand how to arm and disarm, and what special functions they can and cannot do.
2. Remember your user code. Forgotten user codes are the most common cause of false alarms.
3. If you have an optional keyswitch, be sure you know where
your keys are.
4. Shut doors and windows completely. Before arming your system, be sure all protected windows and doors are closed. As you leave the building, shut the exit door com­pletely.
5. Regularly test and maintain your system. Routine test­ing and maintenance will help you detect a service condition. See Section 6 for more information.
6. Be selective when arming the system for instant alarms. This setting should not be used when a user might open a door or window.
7. Make sure your system clock and calendar are accu- rate. Many system functions, such as Kidwatch and Auto­matic Arming, are time-related. Be sure to adjust your clock to reflect seasonal time changes (such as Daylight Savings
Page 39
4
35
Disarm/Alarms
Time). Also, check your clock and calendar after a power failure. See Section 5.
8. Keep pets (and other animals) from motion and infra- red sensors. If you have obtained a pet since your system was installed, your system may need to be modified. Con­tact your dealer for more information.
9. Bypass trouble zones. If your system has one or more trouble zones (zones with sensors that need service), by­pass them before arming. Have the sensor(s) inspected if the problem continues. Remember that bypassed zones are not protected.
Optional Alarm Features
Your system offers additional optional alarm features, described below. Refer to Section 8 to see which of these options are in­stalled on your system.
Alarm Lockout. The system automatically ignores a sensor that repeatedly sends alarm signals.
Silent alarm. With this option, no bells or sirens sound during an alarm, but the monitoring station is notified. If the phone lines are down, or the monitoring station cannot be reached for some other reason, the on-site bells or sirens may be reactivated, depending upon how your system is programmed.
Page 40
5
Settings
36
If your system's clock or calen­dar is incorrect, it could result in false alarms. Since many system functions are time-de­pendent, it is very important
to regularly check your system's clock and calendar.
Be sure to reset the clock after seasonal time changes, such as Daylight Savings Time. Also, although your system may have a backup battery, it is best to check the clock and calendar following a power failure.
NOTE: your system's clock uses a 24-hour, or military-style, format. For example, in a 24­hour format, 1:00 p.m. is ex­pressed as 13:00. Thus, when you enter the hours of the day, be sure to use this format.
To convert from 24-hour time to 12-hour time, subtract 12 hours from all times greater than 12:00; these are p.m. times. (In 24-hour time, midnight is 00:00, and noon is 12:00.)
To Set the Clock
and Calendar:
1. Press and hold the [clock] key for 2 seconds un­til you hear 2 beeps. You see:
ENTER MASTER CODE
2. Enter the master user code.
3. You see something like this:
Enter the day of the month, using two numbers. Then,
press the
key.
4. You see something like this:
Enter the number of the month, using two numbers.
Then, press the
key.
5. You see something like this:
How to Set the Clock and Calendar
Page 41
5
Settings
37
Clock and Calendar (continued)
Enter the number of the year, using two numbers. Press the
key.
6. You see something like this:
Enter the hour of the day, us­ing two numbers. Be sure to use a 24-hour format (see the note.) Then, press the
key.
7. You see something similar to this:
Enter the minutes past the hour, using two numbers.
Then, press the
key.
Your system automatically returns to its normal mode.
Page 42
5
Settings
38
When your system is set to chime, you hear three beeps whenever you open a protected door or window. You can turn the chimes on or off by follow­ing the instructions to the right. If the chimes are on, this ac­tion turns them off.
How to Turn the Chimes On/Off
You hear a beeping sound when the system is about to arm, disarm, or sound an alarm. The warning tone re­minds you that time remains to cancel the arming or disarming sequence, or to cancel the alarm.
You can turn the tone on or off by following the instructions to the right. If the tone is on, the action turns it off. If the tone is off, the action turns it on.
To Turn Tone On/Off:
1. Press and hold the [pre-warn] key for 2 seconds until you hear 2 beeps. When prompted, enter the master user code.
If you hear three beeps, the tone is now on. If you hear one continuous 3-second beep, the tone is now off.
How to Turn the Warning Tone On/Off
To Turn Tone On/Off:
1. Press and hold the [chime] key for 2 seconds until you hear 2 beeps. When prompted, enter the master user code.
If you hear three beeps, the chimes are now on. If you hear one continuous 3-second beep, the chimes are now off.
Page 43
5
Settings
39
To Turn Backlight On/Off :
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. Enter the master user code.
2. Press the
key five
times. You see:
==6
Press the key.
If you hear three beeps, the backlight is now on. If you hear one continuous 3-second beep, the backlighting is now off.
3. To exit, press the key.
Whenever you use your key­pad, a light automatically illumi­nates the display and keys. This backlight shuts off 60 sec­onds after you have finished us­ing the keypad.
If you wish, you can set the backlight to shine continuously. This makes it easier for you to notice system messages, espe­cially if your keypad is located in a dark area.
If you turn the backlight on, you can turn it off again by repeat­ing the procedure to the right.
How to Turn the Backlight On/Off
Page 44
5
Settings
40
How to Change the Relay 1 Days
Your system can be pro­grammed with up to four relays that work on the days of the week you specify. The relays are numbered 1, 2, 3, and 4.
The relays are programmed to turn on or off one or more de­vices which are connected to your system's control panel. You can change the days that the relay works by following the procedure to the right.
For example, a business may use a relay to turn on the flood­lights near its loading docks. By using the relay schedule menu, the business owner could turn the lights off during the busi­ness' upcoming holiday.
You can change the days that the relay works by following the procedure to the right. To change the time of day that the relay works, contact your in­staller.
To Change the Relay 1 Days:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. Enter the master user code.
2. Press the
key 8 times
until you see:
--9
3. Press the key. You see something like this:
--3
The three spaces in the nu­meric display represent the first three days of the week (Sunday-Tuesday). If a space contains a dash, Relay 1 is does not work on that day. If the space contains a number, Relay 1 works on that day. Thus, in the example above, Relay 1 works on Tuesday and does not work on Sunday and Monday.
(continued)
Page 45
5
Settings
41
of the week, press the
key. Each time you press the key, the dis­play moves forward one day.
4. Enter the number of the day you wish to change.
5 To exit, press the
key.
How to Change the Relay 1 Days
To Change the Relay 1 Days
(continued):
How to Change the Relay 2 Days
To change the Relay 2 days, follow the procedure to the right.
To Change the Relay 2 Days:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. Enter the master user code.
2. Press the
key 9 times
until you see:
-10
3. Follow steps 3-5 for chang­ing the Relay 1 Days.
Page 46
5
Settings
42
How to Change the Relay 3 Days
To change the Relay 3 days, follow the procedure to the right.
To Change the Relay 3 Days:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. Enter the master user code.
2. Press the
key 10
times until you see:
-11
3. Follow steps 3-5 for chang­ing the Relay 1 Days.
How to Change the Relay 4 Days
To change the Relay 4 days, follow the procedure to the right.
To Change the Relay 4 Days:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. En­ter the master user code.
2. Press the
key 11
times until you see:
-12
3. Follow steps 3-5 for chang­ing the Relay 1 Days.
Page 47
6
Maintenance
43
How to Walk-Test the System
A walk-test allows you to test your system's functions without causing an alarm. You can be sure your security system is functioning properly by con­ducting a walk-test once a week.
The first step of a walk-test is to place your system in walk­test mode. Then, walk in front of motion sensors, and open protected doors and windows. Each time a sensor detects your presence, the keypad beeps, and names the most re­cently faulted zone in its dis­play.
If your system fails to detect a sensor, exit the walk-test mode and make sure the sensor's zone is not bypassed. If it is bypassed, remove the bypass and repeat the walk-test. If this does not correct the problem, contact your service represen­tative.
IMPORTANT: during a walk­test, your building is not pro­tected against actual alarms.
To Conduct a Walk-Test:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. You see:
ENTER MASTER CODE
2. Enter the master user code. You see:
--1 WALK-TEST
3. Press the key. Test your sensors by opening pro­tected doors and windows, and by walking in front of motion sensors. The keypad beeps twice with each detec­tion, and its display is simi­lar to this:
3 WALK-TEST
In this example, a fault was noted on zone 3.
4. When done, press the
key.
Page 48
6
Maintenance
44
How to Use Event Memory
To Review Event Memory:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. When prompted, enter the master user code.
2. Press the
key. You
see:
--2
3. Press the key. You see:
1_4 ENTER
4. To view the oldest events first, press . To view the latest events first, press
. Refer to the next pages to interpret the mes­sages.
5. Press
to view the next event, or to view the previous event. To exit, press the
key .
Your system records important events, such as alarms, in Event Memory. You can review Event Memory to monitor the status of your system. As many as 500 events may be re­corded.
Page 49
6
Maintenance
45
Code
An alarm occurred on the zone listed. A system device was deliberately damaged. A sensor was in need of service. A sensor problem was corrected. A zone was bypassed.
A bypass on a zone was removed. The system was disarmed. The system was armed. A walk-test began. A walk-test ended.
A user canceled an alarm. An attempt to contact the monitoring station failed. A communications problem was corrected. The system lost its AC (house current) power. The system's AC (house current) power was restored.
The system's backup battery was low. A low battery condition was corrected. A user code was changed. The primary phone line was disconnected. The primary phone line was reconnected
The secondary phone line was disconnected. The secondary phone line was reconnected. A medical emergency alarm occurred. A medical emergency alarm was restored. A police emergency alarm occurred.
A police emergency alarm was restored. A fire alarm occurred. A fire alarm was restored. The system was placed in the programming mode. The system was taken out of the programming mode.
A wireless device malfunctioned. A malfunction in a wireless device was corrected. A wireless device had a low battery. A wireless device's low battery was corrected. The system reset itself, most likely because of a momentary power loss.
The sirens or bells malfunctioned. A malfunction in the system's sirens or bells was corrected. An alarm occurred when an exit door was not completely closed during arming. The duress code was used. The Kidwatch Code was not entered within the Kidwatch window.
A remote programming session was initiated. An attempt at a remote programming session was denied. An attempt at a remote programming session was successful. A test report was sent to the monitoring station. A malfunction in a sensor was corrected.
Meaning
1 2 3 4 5
6 7 8 9
10
11 12 13 14 15
16 17 18 19 20
21 22 23 24 25
26 27 28 29 30
31 32 33 34 35
36 37 38 39 40
41 42 43 44 45
(Table continued on next page)
Event Memory Codes
Page 50
6
Maintenance
46
A user canceled the auto-arming sequence. A damaged sensor was corrected. An electrical circuit is shorted. (Ground fault.) A ground fault condition was corrected. A partial power loss occurred (brown out).
A partial power loss was corrected. A sensor was malfunctioning. A malfunction in a sensor was corrected. A sensor was tampered with. Problems caused by a sensor being tampered with were corrected.
A keypad was malfunctioning. A malfunction in a keypad was corrected. A keypad was tampered with. Problems caused by a keypad being tampered with were corrected. A SpreadNet (wireless) keypad did not communicate with the system.
Problems with a SpreadNet (wireless) keypad's communication were corrected. A SpreadNet (wireless) keypad had a low battery. Problems with a SpreadNet (wireless) keypad's battery were corrected. A system user used the Quick Exit feature. The system's power was turned on.
The system had too many messages to report to the monitoring station. A wireless keyfob or remote had a low battery. Problems with a keyfob or remote's low battery were corrected.
46 47 48 49 50
51 52 53 54 55
56 57 58 59 60
61 62 63 64 65
66 67 68
Code Meaning
Event Memory Codes (continued)
Page 51
6
Maintenance
47
How to Test the Bells and Sirens
To Test the Bells and Sirens:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. When prompted, enter the master user code.
2. Press the
key twice.
You see:
--3
3. Press the key. The bells and sirens ring for 4 sec-
onds.
4. To exit, press the key.
You can test your system's bells and sirens by following the procedure to the right.
Page 52
6
Maintenance
48
To Start a Remote Programming Session
If you have a monitoring station hookup, your installer may be able to program your security system through the telephone line. It is not necessary for a technician to come to your home or business to make changes to your system.
At your monitoring station's prompting, you can initiate a re­mote programming session by following the directions to the right.
To Start A Remote
Programing Session:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. When prompted, enter the master user code.
2. Press the
key three
times. You see:
--4
3. Press the key. The remote programming session
begins. Normally, a remote programming session takes just a few minutes.
Page 53
6
Maintenance
49
How to Test the Battery
Your system may include a backup battery. If it does, the system will continue to function during a power failure, because it will draw power from the bat­tery.
You can test the charge in your system's battery by following the procedure to the right.
If your backup battery's charge is low, the TROUBLE icon lights. To investigate the ser­vice message, follow the in­structions in "Troubleshooting Service Conditions," later in this section.
To replace your system's bat­tery, call your service represen­tative.
To Test the Battery:
1. Press and hold the [walk test] key for 2 seconds until you hear 2 beeps. When prompted, enter the master user code.
2. Press the
key four
times. You see:
--5
3. Press the key. The keypad beeps three times. The battery test begins. The test takes approximately 2 minutes. If the battery's charge is low, the keypad's TROUBLE icon lights.
To replace your system's bat­tery, call your service repre­sentative.
Page 54
6
Maintenance
50
Common System Messages
Below is an explanation of the common messages your keypad might display. Beside each message is a discussion of what re­sponses are appropriate. If you find the response is ineffective, call your local C&K service representative.
In the table below, the ellipses (...) represent the specific informa­tion, such as zone numbers that appear in the numeric display.
If you notice That means What to do:
Power LED is off Keypad is not Verify that the rest of the
receiving AC building is receiving power; (house current) power then call for service.
That
Display reads: A sensor needs Bypass the sensor, or "TROUBLE..." service arrange for repair.
Display reads: A sensor may have Call for service. "TAMPER ..." been tampered with
Display often A sensor may need Call for service.
reads: "TROUBLE...." service
or "TAMPER..."
Display reads: Any one of your Depending upon your "NOT READY" sensors may be arming type, your system
faulted may be able to arm. If not,
correct any faulted zones and then attempt to arm.
Display reads An alarm occurred Refer to "Resetting After an "ALARM..." Alarm" Section 4.
Display reads A zone has been Remember the zone is "BYPASS..." bypassed unprotected while bypassed.
You can remove the bypass (Section 3), or arm/disarm with bypass in place.
Page 55
6
Maintenance
51
Troubleshooting Service Conditions
Your system notifies you if a keypad, sensor, or other system com­ponent needs service by lighting the TROUBLE icon, and by beep­ing twice every 30 seconds for one minute.
To get more information about the service message, press and hold the
[service] key for two seconds. A code appears in your keypad's numeric display. As the table below shows, differ­ent messages are conveyed depending on which code is dis­played. Follow the recommended course of action listed in the table.
To stop the service message warning tone, enter your user code between the two beeps. You may have more than one service message. To view the next message, press the
key again. If there are no new messages, your keypad exits the Service Message display.
What to doMessageCode
1
2
3
4
There is a power failure in progress.
The control panel's battery is low.
The monitoring station (phone #1) does not answer.
The monitoring station (phone #2) does not answer.
Look for signs of power failure in other building equipment; if not found, call for service. Reset the clock, once power is restored.
If there has been a recent power outage, allow the battery to recharge overnight. If the problem remains, call for service.
If line is functioning, call monitoring station. If not, call telephone company for service.
If line is functioning, call monitoring station. If not, call telephone company for service.
Page 56
6
Maintenance
52
What to doMessageCode
8
9
10
11
12
13
14
15
16
64
128
192
A keypad is malfunction­ing.
Self-diagnostic failure of a sensor.
The external bell/siren needs service.
Phone line #1 is not working.
Phone line #2 is not working.
Electrical power from the system has short-circuited to the ground wire.
Brown out (power loss short of total failure)
There are too many messages to send to the monitoring station.
A wireless keyfob or remote arming device has a low battery.
A keypad has been vandalized.
A system component has been vandalized.
A system component is not communicating with the control panel.
Call for service.
Call for service.
Call for service.
If line is functioning, call monitoring station. If not, call telephone company for service.
If line is functioning, call monitoring station. If not, call telephone company for service.
Call for service.
When power returns to normal, system should revert to normal functioning. If not, call for service.
If telephone line is functioning, call monitoring station. If not, call telephone company for service.
Press the [6] key to identify which component has the low battery condition. Press the [3] key to see the next service message. To replace the battery, call for service.
Call for service.
Call for service.
Call for service.
Page 57
53
Areas
7
What Areas Do
Your security system allows you to divide (or "partition") a building into as many as eight areas, regions that can be armed and disarmed individu­ally. Designed primarily for commercial settings, areas can limit an individual's access to portions of a building.
A building that is divided into areas may include a common area, an area most system us­ers can arm and disarm. The first diagram shows how a building could be divided to in­clude a common area.
Buildings may also be parti­tioned without a common area. As the second diagram shows, this setup works well for struc­tures with tenant spaces, but no lobby or shared hallway.
Each system user is assigned rights to certain areas. Users can arm and disarm only those areas to which they have rights.
When a building is divided into areas, portions of the building
Diagram 1
Partitioned building
with a common area
Page 58
54
Areas
7
Diagram 2
Partitioned building
with no common area
can be independently armed and disarmed. In the case of the first building illustrated, an employee can work in the re­pair shop while the showroom, offices, and warehouse are armed. Similarly, in the case of the second illustration, the restaurant can remain open af­ter the other shops are closed and armed.
Dividing a building into areas changes the following system functions:
1. Users have restricted ac­cess to system functions. A
user with access to only one area cannot issue commands affecting other areas, or obtain information about the other ar­eas.
2. Keypads may respond dif­ferently, depending upon
where they are located and how they are programmed. Your icon keypad is limited to handling information about its assigned area only.
Page 59
55
Areas
7
How Areas Affect User Codes
As described below, some of the user code types function differently in a partitioned system.
Area
Grand Master User Code. The grand master user can assign and change user codes, and may be able to arm and disarm the entire system. Only the grand master user and your installer can view and change the grand master user code.
Area Master User Code. Each area has its own master user. The area master user can make any user-controlled changes within a given area.
Area Basic User Code. Area basic users can dis­arm and may be able to arm, bypass, or make other changes within an area. Users can have rights to more than one area.
Area Maid Code. Maid Days are assigned to each area, so if you need to change the Maid Days, you must make the changes for each area individually.
Kidwatch Code. Your system recognizes only one Kidwatch Code, regardless of how many areas are present. The Kidwatch Code is assigned to area 1.
Area Duress Code. One duress code can be as­signed to each area.
Area Relay Code. One relay code can be assigned to each area.
Area
If your building is divided into areas, your system may also recognize one or more of these optional user code types:
Area
Area
Area
Page 60
56
Areas
7
Pre-Assigned Area User Numbers
As the table below shows, some user numbers are reserved for specific user types. For example, User 11 is the preassigned Kidwatch user number. If programmed, your system automati­cally restricts User 11 to the limited Kidwatch privileges.
When your system does not recognize a given user type, the user number functions like other non-reserved user numbers. If your building is not divided into areas, user codes reserved for areas do not apply. Also, if your building is divided into only two or three areas, codes reserved for the remaining areas do not apply.
No. Reserved User
01 Grand Master User 11 Kidwatch 12 Area 1 Master 13 Area 1 Maid 15 Area 1 Duress 16 Area 2 Master 17 Area 2 Maid 19 Area 2 Duress 20 Area 3 Master 21 Area 3 Maid 23 Area 3 Duress 24 Area 4 Master 25 Area 4 Maid
No. Reserved User
27 Area 4 Duress 28 Area 5 Master 29 Area 5 Maid 31 Area 5 Duress 32 Area 6 Master 33 Area 6 Maid 35 Area 6 Duress 36 Area 7 Master 37 Area 7 Maid 39 Area 7 Duress 40 Area 8 Master 41 Area 8 Maid
43 Area 8 Duress
Changing Area User Codes
In a system with multiple areas, an Area Master User can only change the codes of the users assigned to that area. If you at­tempt to change the code of a user when you do not have the right to do so, you hear an error tone.
Page 61
57
Areas
7
How Areas Affect the System
If your building is divided into areas, your icon keypad is assigned to one area only. From the icon keypad, you can only make changes that affect that area alone. This is described in more detail below.
Arming and disarming. Your icon keypad can be used to arm and disarm its assigned area only. You cannot disarm other areas from the icon keypad.
Bypassing. You can use the icon keypad to bypass only those zones within the assigned area.
Obtaining other system information. From the icon key­pad, you can get information about the zones within the as­signed area only.
Canceling alarms. You can only cancel alarms occurring within the assigned area.
Page 62
58
8
Notes
Monitoring Station: ______Yes ______No Maximum Number of Users: ______ Partitioned: ______Yes ______No Keypad assigned to area #:_________________________ Alternate Language: ______________________________ Learning Period (days): ______________ Begins: ________
System Configuration
Your installer will fill out these pages, to indicate how your system has been configured.
Setup
Options
Check if installed:
_____Maid Code _____Kidwatch Code _____Duress Code
_____Automatic (Timed) Arming _____Automatic Disarming _____Quick Home-Arming _____Quick Full-Arming _____Automatic Home-Arming _____Quick Instant Home-Arming
_____Force Arming _____Goof-Proof Arming _____Chirp-Alert Arming
_____Quick Bypassing _____Quick Exit _____Exit Termination
_____Extended Exit Delay _____Reset Code _____Keypad Lockout _____Alarm Lockout _____Silent Alarm
Emergency Keys: _____Medical _____Fire _____Police
_____ Keyfob Arming _____ Keyswitch Arming
Page 63
59
8
Notes
Temporary Maid Code Hours: _________________________
Kidwatch Time: ___________________________________
Entry Delay #1 __________enter through:_______________
Entry Delay #2: __________enter through:_______________
Exit Delay: ________________________________________
Cancel Alarm Time: _________________________________
Automatic Arming Time: _____________________________
Automatic Disarming Time: ___________________________
Device Connected to Relay 1: _________________________
_________________________________________________
Device Connected to Relay 2: _________________________
_________________________________________________
Device Connected to Relay 3: _________________________
_________________________________________________
Device Connected to Relay 4: _________________________
_________________________________________________
Other: ___________________________________________
Customization
Page 64
60
8
Notes
Below is a space to sketch how the building is zoned and/ or divided into areas. Be sure to note how the zones and/ or areas are numbered and labeled.
Sketch
Page 65
61
8
Notes
Glossary of Terms
Area: a region of a building that can
be armed and disarmed independently of the remainder of the building.
Bypassing: the act of instructing your security system to ignore a zone. A by­passed zone is not protected.
Entry Delay: The amount of time you have to enter your armed building, walk to the keypad, and enter your user code before an alarm sounds.
Exit Delay: The amount of time you have to exit and secure your building before an alarm sounds.
Faulted: describes a condition which, if the system were armed, would cause an alarm, such as an opened door or window. Faulted zones must be cor­rected or bypassed before arming oc­curs.
Full Arming: a method of arming that arms all of your system's sensors, both along the building's perimeter, and in­side the building.
Home Arming: a method of arming that arms only those sensors along the pe­rimeter of your building.
Instant Home-Arming: a method of arming that triggers an alarm the instant a sensor detects an alarm condition.
Monitoring Station: a service that monitors the status of your security sys­tem through a telephone hook-up.
Tamper: describes a sensor, or other system equipment, that has been de­liberately damaged.
Trouble: describes a sensor, or other system equipment, that may be in need of service.
User Code: a secret four-digit number used to arm and disarm the system, and make other changes.
User Number: a two-digit number as­signed to each user.
Zone: a sensor or a group of sensors protecting a region of your building.
24-Hour Zone: a zone, such as a smoke detector, which is programmed to detect alarm conditions whether your system is armed or disarmed.
Page 66
62
8
Notes
Notes
Page 67
63
8
Notes
Index
Alarm
canceling 31 lockout 35 resetting after 31
Area
defined 53 effects on system 57
Area user codes
assigned 56 changing 56 types 55
Arming
automatic 18, 23 automatic home- 29 canceling 19 Chirp-Alert 25 full 18, 20 Force 25 Goof-Proof 25 home 18, 21 instant home- 18, 22 quick 18 quick full- 20 quick home- 21 quick instant home- 22
Backlight, turning on/off 39 Battery test 49 Bell test 47 Bypassing 26 Bypassing, quick 27
Calendar, setting 36 Chimes, turning on/off 38 Clock, setting 36
Date, setting 36 Disarming 30 Disarming, automatic 32
Emergency keys 4, 7 Entry delays 30
Event Memory 44 Exit delay 19 Exit termination 28 Extended exit delay 28
False alarms, preventing 34
Glossary 61
Keyfob, deleting lost 11 Keypad lockout 28 Keyswitch arming 28
Learning period 3
RPS session 48 Relay 1 days, changing 40 Relay 2 days, changing 41 Relay 3 days, changing 42 Relay 4 days, changing 42 Remote, deleting lost 11 Remote Programming Session 48
Secondary Function Keys 4 Service conditions 51 Silent Alarm 35 Siren test 47 System messages 6, 50
Quick exit 28
Time, setting 36 Troubleshooting guide 51
User codes, types
Basic 12 Duress 13 Kidwatch 14 Maid 16
Master 12 Relay 13 Temporary Maid 17 with areas 55
User codes, using
assigning 10 changing 10 deleting 11 entering 9
User numbers 8
Walk-test 43 Warning tone, turning on/off 38
Page 68
64
8
Notes
Sierra is a registered trademark
of C&K Systems
C&K is a registered trademark of
C&K Components
http:// www.cksys.com
Copyright 1998, C&K Systems, Inc.
5-051-531-01 Rev A