Siemens XLT Series, XLT-60, XLT-30 Operating Instructions Manual

Ultrasonic Transducers
XLT
Operating Instructions 03/2013
This manual outlines the essential features and functions of the XLT series transducers. The
Transducer Applications Manual
www.siemens.com/processautomation Siemens Milltronics representative.
Questions about the contents of this manual can be directed to:
Siemens Milltronics Process Instruments Siemens AG 1954 Technology Drive, P.O. Box 4225 Industry Sector Peterborough, Ontario, Canada, K9J 7B1 76181 Karlsruhe Email: techpubs.smpi@siemens.com
Copyright Siemens Milltronics Process
Instruments 2013.
All Rights Reserved
We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments. Siemens Milltronics Process Instruments will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions.
is available for free download on our website:
. A printed version can be purchased from your local
European Authorized Representative
Deutschland
Disclaimer of Liability
While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement.
Technical data subject to change.
English
mmmmm
MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments
Safety Guidelines
Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed.
WARNING: relates to a caution symbol on the product, and means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage.
WARNING: means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage.
CAUTION: means that failure to observe the necessary precautions can result in considerable material damage.
Note: means important information about the product or that part of the operating manual.
A5E32280448 XLT Series Transducers - OPERATING MANUAL Page EN-1
mmmmm
Unit Repair and Excluded Liability
The user is responsible for all changes and repairs made to the device by the user or by the user’s agent.
All new components are to be provided by Siemens Milltronics Process Instruments Inc.
English
Restrict repair to faulty components only.
Do not reuse faulty components.
Page EN-2 XLT Series Transducers - OPERATING MANUAL A5E32280448
Introduction
transducer
transducer face
-3db boundary
axis of transmission, perpendicular to transducer face
This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications
The Echomax XLT series of transducers operate with Siemens Milltronics ultrasonic level monitoring products.
The transducer converts the electrical energy of the transmit pulse from the controller into acoustical energy. It then converts the acoustical energy of the echo back into electrical energy for the controller.
The transducer face emits acoustical energy that radiates outward, decreasing in amplitude at a rate inversely proportional to the square of the distance. Maximum power radiates perpendicularly from the transducer face on the axis of transmission. Where power is reduced by half (– 3 dB), a conical boundary centered around the axis of transmission defines the sound beam, the diameter of which is the beam angle.
.
English
mmmmm
The XLT transducers have an integrated temperature sensor that reports the air temperature at the transducer to the controller.
General Guidelines
WARNING: Materials of construction are chosen based on their chemical
compatibility (or inertness) for general purposes. For exposure to specific environments, check with chemical compatibility charts before installing.
• The equipment may be used in Category 2 (Zone 1), or Category 3 (Zone 2) gas zones and all hazardous dust zones with all conductive and non-conductive dusts.
• The XLT-30 and XLT-60 series transducers all carry a maximum surface temperature of 200ºC (i.e. Temperature Class T3). These units are certified for use in an ambient range of –40 ºC to +150 ºC. Do not use units outside the temperature range.
• These devices should only be supplied from a circuit containing a suitably-rated fuse that has a breaking capacity of 4000A. This fuse is included in Siemens Milltronics transceivers.
• Repair of this equipment shall be carried out in accordance with the applicable code of practice/Installation Instructions.
A5E32280448 XLT Series Transducers - OPERATING MANUAL Page EN-3
mmmmm
R
II2G1DT3 II2GDT3 EExmIIT3
SIRA 01ATEX5294X
Assembled in Canada with domestic
and imported parts
Siemens Milltronics Process Instruments, Peterborough
Class I, Div 1, Gr.A,B,C,D Class II, Gr. E, F, G
PER DWG # 0-8830004Z-DI-A
TEMP. CODE: T3C
Class I, Div 2, Gr. A, B, C, D Class II, Div 2, Gr. F, G PER DWG # 0-9650016Z-DI-A
0518
Ex mb IIC T3 Gb Ex tb IIIC T200 °C Db DNV 12.0076 X
XLT-xx
ULTRASONIC TRANSDUCER
Serial No.: GYZ / V1034567
Type: FLEXURAL MODE
Enclosure: IP68
Amb. Temp.: – 40°C to 150°C
Max. Input Current: 44.2 mA r.m.s.
Max. Input Voltage: 1.77 V r.m.s.; 250 Vp
KCC-REM-S49
Echomax
OCP 0017
• The certification of the XLT range of transducers relies upon the use of following materials in the construction:
Enclosure: Aluminum Encapsulant: Durapot 861-F3 / 864
English
WARNING: If the equipment is likely to come into contact with aggressive
substances, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised.
Aggressive Substances: acidic liquids or gases that may attack metals or solvents that may
affect polymeric materials.
Suitable Precautions: regular checks as part of routine inspections or establishing from
the material’s data sheet that it is resistant to specific chemicals.
For manual override, use the disconnect switch provided in the building installation of the associated controller.
XLT Series Product Marking
WARNING:
(7/23/EC and is not intended for use as a safety device.
T h i s p r o d u c t i s d e s i g n a t e d a s a P r e s s u r e A c c e s s o r y p e r D i r e c t i v e
Page EN-4 XLT Series Transducers - OPERATING MANUAL A5E32280448
Specifications
XLT-30 XLT-60
Measurement Range 0.9 - 30 m
(3 - 100 ft)
Frequency Beam Angle
22 KHz 13 KHz 5 5
1.8 - 60 m (6 - 200 ft)
Environmental
Location indoor/outdoor indoor/outdoor Maximum Altitude Ambient Temperature
Ambient Pressure N. America: up to 1000 kPa (1 bar, 15 psi)
Pollution Degree 44
2000 m 2000 m
-40 to 150 C (-40 to 300 F)
Europe: up to 50 kPa (0.5 bar, 7.25 psi)
-40 to 150 C (-40 to 300 F)
Construction
Housing aluminum, 304 stainless steel,
and silicon
Mounting 1" NPT conduit connection 1" NPT conduit connection
Cable
2-wire shielded/twisted,
0.5mm2 (20 AWG) Silicone jacket
aluminum, 304 stainless steel, and silicon
2-wire shielded/twisted, 0.5mm2 (20 AWG) PVC jacket
English
mmmmm
Weight** 6.6 kg
(14.5 lb)
Maximum separation from transceiver
Supply Source Transducers shall only be supplied by Siemens Milltronics
Approvals CE**, CSA, FM, SIRA/CENELEC
* Approximate shipping weight of transducer with standard cable length. ** EMC performance available upon request .
365 m (1200 ft)
certified controllers
See nameplate or consult Siemens Milltronics for current approvals
6.6 kg (14.5 lb)
365 m (1200 ft)
, INMETRO
A5E32280448 XLT Series Transducers - OPERATING MANUAL Page EN-5
mmmmm
d
h (nominal)
earth connection screw clamp (1 place)
1” NPT
safety connection 9mm (3/8”) dia. hole (2places)
XLT-30 XLT-60
h 249 mm (9.8") 324 mm (12.75") d 264 mm (10.4") 335 mm (13.2")
Outline and Dimensions
English
Page EN-6 XLT Series Transducers - OPERATING MANUAL A5E32280448
Mounting
Easy Aimer (typical model)
to nearest earth/ground
safety chain
earth/ground connection
Note: Installation shall only be performed by qualified personnel and in accordance with
local governing regulations.
Mount the transducer so that it is above the maximum material level by at least the
blanking value. Refer to the associated controller manual.
On liquid applications, the transducer must be mounted so that the axis of transmission is
perpendicular to the liquid surface.
On solids applications, use a Siemens Milltronics Easy Aimer to aim the transducer.
Secure installation by connecting a safety chain from the transducer to a structural
member.
Consider the optional temperature sensor when mounting the transducer.
Caution: Wear proper ear protection in the vicinity of the operating transducer.
The XLT 60 transducers could emit hazardous sound pressure. They shall be installed
in such a manner that the sound pressure will be reduced to a non-hazardous level.
Solids Applications
English
mmmmm
WARNING: Easy Aimer configurations are not suitable for pressure applications.
A5E32280448 XLT Series Transducers - OPERATING MANUAL Page EN-7
mmmmm
plate or bracket
flexible conduit
to nearest earth/ ground
coupling
safety chain
transducer
safety chain
coupling
coupling
nipple welded to
blind flange
to nearest earth/ ground
Flange, gasket, and hardware supplied by customer.
Liquid Applications
Flexible Conduit
English
Blind Flange
Page EN-8 XLT Series Transducers - OPERATING MANUAL A5E32280448
Interconnection
wht/shld
blk/hot
blk wht
Siemens Milltronics controller (typical)
junction
box
blk
drain/shield
wht
extend cable using 18 AWG shielded/twisted pair
extend cable using RG - 62 A/U coax for optimum signal to noise ratio
Direct Connection
Note: When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, or a HydroRanger 200, the white, black, and shield wires are all connected separately. DO NOT tie the white and shield wires together.
2-Wire Extension
English
mmmmm
Note: When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, or a HydroRanger 200, the white, black, and shield wires are all connected separately. DO NOT tie the white and shield wires together.
Coaxial Extension
Note: Grounding transducer as shown is mandatory per safety regulations and for
isolation against electrical interference.
A5E32280448 XLT Series Transducers - OPERATING MANUAL Page EN-9
mmmmm
Installation
Installation shall only be performed by qualified personnel and in accordance with local
governing regulations.
Do not route cable openly; instead run cable separately in a grounded metal conduit to
English
protect it from ambient electrical noise.
Seal all thread connections to prevent the ingress of moisture.
Do not run cable near high voltage or current runs, contactors or SCR control drives.
For pressure tight applications, install transducers hand tight plus ½ turn to 1½ turns.
PTFE tape or other appropriate sealant may be used to aid in sealing the threads for use in pressure applications.
WARNING: Improper installation may result in loss of process pressure.
Page EN-10 XLT Series Transducers - OPERATING MANUAL A5E32280448
Echomax XLT Driftsvejledning
Denne manual opridser de væsentligste karakteristika og funktioner af transducerne i serien XLT. Manualen www.siemens.com/processautomation Milltronics repræsentant.
Vejledning i anvendelse af transducere
. Et trykt eksemplar kan købes hos din lokale Siemens
kan downloades gratis fra vort website:
Spørgsmål vedrørende indholdet af denne manual kan rettes til:
Siemens Milltronics Process Instruments Siemens AG 1954 Technology Drive, P.O. Box 4225 Industry Sector Peterborough, Ontario, Canada, K9J 7B1 76181 Karlsruhe Email: techpubs.smpi@siemens.com
Europæisk autoriseret repræsentant
Deutschland
Copyright Siemens Milltronics
Process Instruments 2013.
Ansvarsfragåelse
Alle rettigheder forbeholdes
Vi opfordrer brugerne til at anskaffe de autoriserede, indbundne manualer eller at læse de elektroniske versioner, der er udarbejdet og skrevet af Siemens Milltronics Process Instruments. Siemens Milltronics Process Instruments påtager sig intet ansvar for indholdet af delvise eller fuldstændige gengivelser af indbundne eller elektroniske versioner.
Skønt vi har kontrolleret, at indholdet af denne manual stemmer overens med de beskrevne instrumenter, kan der stadig forekomme variationer. Vi kan derfor ikke garantere en fuldstændig overensstemmelse. Indholdet af denne manual revideres jævnligt, og eventuelle rettelser inkluderes i de efterfølgende udgaver. Vi modtager gerne forslag til forbedringer.
Retten til ændringer af de tekniske data forbeholdes.
Dansk
MILLTRONICS er et registreret varemærke, der tilhører Siemens Milltronics Process Instruments
Sikkerhedsvejledning
De anførte advarsler skal overholdes for at sikre egen og andres sikkerhed samt for at beskytte produktet og det tilhørende udstyr. Disse advarsler ledsages af en tydeliggørelse af graden af forsigtighed, der bør overholdes.
ADVARSEL: vedrører et advarselssymbol på produktet og betyder, at en manglende overholdelse af de nødvendige forholdsregler kan føre til død, alvorlig personskade og/eller omfattende materielle skader.
ADVARSEL: betyder, at en manglende overholdelse af de nødvendige forholdsregler kan føre til død, alvorlig personskade og/eller omfattende materielle skader.
PAS PÅ: betyder, at en manglende overholdelse af de nødvendige forholdsregler kan føre til omfattende materielle skader.
Bemærk: betyder vigtige oplysninger om produktet eller denne del af brugsvejledningen.
A5E32280448 XLT Serie Transducere - DRIFTSVEJLEDNING Side DA-1
Reparation af instrumentet og ansvarsbegrænsning
Brugeren er ansvarlig for alle modifikationer og reparationer, der udføres på apparatet af brugeren eller dennes repræsentant.
Alle nye dele skal leveres af Siemens Milltronics Process Instruments Inc.
Kun defekte dele bør repareres.
Defekte dele må ikke genbruges.
Dansk
Side DA-2 XLT Serie Transducere - DRIFTSVEJLEDNING A5E32280448
Indledning
transducer
transducer­overflade
-3db grænse
transmissionsakse,
vinkelret på
transduceroverfladen
Dette produkt er beregnet til anvendelse i industriområder. Brugen af dette udstyr i et beboelsesområde kan forårsage interferens med forskellige frekvensbaserede kommunikationer.
Transducerne i serien Echomax XLT fungerer med Siemens Milltronics ultralydsniveauovervågnings­produkter.
Transduceren omdanner den elektriske energi af sendeimpulsen fra kontrolenheden til akustisk energi. Derefter omdanner den ekkoets akustiske energi tilbage til elektrisk energi til kontrolenheden.
Transduceroverfladen udsender akustisk energi, der udbreder sig med en amplitude, der falder omvendt proportionalt til kvadraten af afstanden. Den udbredte effekt er maksimal vinkelret på transduceroverfladen langs transmissionsaksen. Lydstrålen, hvis diameter betegnes strålevinklen, defineres som en kegle centreret omkring transmissionsaksen med en grænse svarende til en reduktion af effekten til halvdelen (– 3 dB).
Dansk
XLT transducerne har en indbygget temperaturføler, der angiver lufttemperaturen til kontrolenheden.
Generel vejledning
ADVARSEL: Konstruktionsmaterialerne er valgt på basis af deres kemiske
kompatibilitet (eller inerti) ved almindelig brug. Hvis de skal udsættes for særlige omgivelser, bør foreneligheden kontrolleres i tabeller over kemiske kompatibiliteter inden installationen.
• Dette udstyr kan anvendes i områder med gas af Kategori 2 (Zone 1) eller Kategori 3 (Zone
2) samt i alle eksplosionsfarlige støvede områder med ledende eller ikke-ledende støv.
• Transducerne i serierne XLT-30 og XLT-60 har alle en maksimal overfladetemperatur på 200 ºC (svarende til Temperaturklassen T3). Disse enheder er godkendt til brug i et interval af omgivende temperaturer på fra –40 ºC til +150 ºC. Disse enheder bør ikke anvendes uden for dette temperaturinterval.
• Disse apparater bør kun strømforsynes fra et kredsløb, der omfatter en sikring af passende intensitet, der har en brydeevne på 4.000A. Denne sikring er inkluderet i Siemens Milltronics’ transceivere.
• Reparation af dette udstyr skal udføres i henhold til de gældende normer/ Installationsvejledningen.
A5E32280448 XLT Serie Transducere - DRIFTSVEJLEDNING Side DA-3
• Godkendelsen af transducerne i XLT serien er afhængig af brugen af følgende materialer
R
II2G1DT3 II2GDT3 EExmIIT3
SIRA 01ATEX5294X
Assembled in Canada with domestic
and imported parts
Siemens Milltronics Process Instruments, Peterborough
Class I, Div 1, Gr.A,B,C,D Class II, Gr. E, F, G
PER DWG # 0-8830004Z-DI-A
TEMP. CODE: T3C
Class I, Div 2, Gr. A, B, C, D Class II, Div 2, Gr. F, G PER DWG # 0-9650016Z-DI-A
0518
Ex mb IIC T3 Gb Ex tb IIIC T200 °C Db DNV 12.0076 X
XLT-xx
ULTRASONIC TRANSDUCER
Serial No.: GYZ / V1034567
Type: FLEXURAL MODE
Enclosure: IP68
Amb. Temp.: – 40°C to 150°C
Max. Input Current: 44.2 mA r.m.s.
Max. Input Voltage: 1.77 V r.m.s.; 250 Vp
KCC-REM-S49
Echomax
OCP 0017
ved deres fremstilling:
Hus: Aluminum Indkapsling: Durapot 861-F3 / 864
ADVARSEL: Hvis det er sandsynligt, at udstyret vil komme i kontakt med
aggressive stoffer, påligger det brugeren at træffe egnede foranstaltninger for at undgå enhver uhensigtsmæssig påvirkning, således at denne type beskyttelse ikke sættes over styr.
Aggressive stoffer: væske- eller gasformige syrer, der kan angribe metaller, eller
opløsningsmidler, der kan påvirke polymere materialer.
Egnede forholdsregler: jævnlig kontrol i forbindelse med de rutinemæssige inspektioner
Dansk
For en manuel omgåelse bruges den afbryder, der indgår i installationen af den tilhørende kontrolenhed i bygningen.
eller godtgørelse ud fra materialets datablad af, at det er modstandsdygtigt over for specifikke kemikalier.
XLT seriens produktmærkning
ADVARSEL:
direktivet 97/23/EF og er ikke beregnet til brug som sikkerhedsanordning.
Dette produkt betegnes som trykbærende udstyr i henhold til
Side DA-4 XLT Serie Transducere - DRIFTSVEJLEDNING A5E32280448
Tekniske data
XLT-30 XLT-60
Måleområde
Frekvens Strålevinkel
0,9 - 30 m (3 - 100 fod)
22 KHz 13 KHz 5 5
Omgivelser
Placering indendørs/udendørs indendørs/udendørs Maksimal højde
Omgivelsestemperatur
Omgivende tryk
Forureningsgrad 44
2000 m 2000 m
-40 til 150 C (-40 til 300 F)
Nordamerika: op til 1000 kPa (1 bar, 15 psi) Europa: op til 50 kPa (0,5 bar, 7,25 psi)
Konstruktion
Hus aluminum, 304 rustfrit stål og
silicone
Montage
1" NPT rørtilslutning 1" NPT rørtilslutning
1,8 - 60 m (6 - 200 fod)
-40 til 150 C (-40 til 300 F)
aluminum, 304 rustfrit stål og silicone
Dansk
Kabel
Vægt**
Maksimal afstand fra transceiveren
Forsyningskilde
Godkendelser
* Omtrentlig forsendelsesvægt af transducer med standard kabellængde. ** EMC-data fås på anfordring.
2-tråds afskærmet/snoet,
2
0,5mm
(20 AWG)
Siliconekappe
6,6 kg (14,5 lb)
365 m (1200 fod)
Transducerne må kun forsynes fra kontrolenheder, der er godkendt af Siemens Milltronics
CE**, CSA, FM, SIRA/CENELEC, INMETRO Se på navneskiltet eller jf. Siemens Milltronics for de gældende godkendelser.
2-tråds afskærmet/snoet, 0,5mm (20 AWG) PVC-kappe
6,6 kg (14,5 lb)
365 m (1200 fod)
2
A5E32280448 XLT Serie Transducere - DRIFTSVEJLEDNING Side DA-5
Omrids og dimensioner
d
h (nominel)
skruetvinge til jordforbindelse (1 sted)
1” NPT
hul til sikkerhedsfastgørelse 9 mm (3/8”) i diam. (2 steder)
XLT-30 XLT-60
h 249 mm (9,8") 324 mm (12,75") d 264 mm (10,4") 335 mm (13,2")
Dansk
Side DA-6 XLT Serie Transducere - DRIFTSVEJLEDNING A5E32280448
Montage
Easy Aimer (typisk model)
til nærmeste jord
sikkerhedskæde
jordforbindelse
Bemærk: Installationen må kun foretages af kvalificeret personale og under
overholdelse af de lokalt gældende regler.
Transduceren monteres, så den sidder i en afstand over materialets maksimale niveau,
der mindst er lig med slukningsafstanden. Der henvises til manualen for den tilhørende kontrolenhed.
Ved anvendelser med væsker skal transduceren monteres, således at
transmissionsaksen er vinkelret på væskeoverfladen.
Ved anvendelser med faste stoffer bruges en Siemens Milltronics Easy Aimer til at rette
transduceren ind.
Installationen sikres ved at fastgøre en sikkerhedskæde mellem transduceren og et
strukturelement.
Tag højde for en eventuel temperaturføler (ekstraudstyr) ved montering af transduceren.
Pas på: Bær egnet høreværn i nærheden af transduceren, når den er i drift.
XLT 60 transducerne kan afgive sundhedsskadeligt lydtryk. De skal installeres på en sådan made, at lydtrykket reduceres til et ufarligt niveau.
Dansk
Anvendelser med faststoffer
ADVARSEL: Konfigurationer med Easy Aimer er ikke egnet til anvendelser under
tryk.
A5E32280448 XLT Serie Transducere - DRIFTSVEJLEDNING Side DA-7
Anvendelser med væsker
plade eller bjælke
bøjeligt rør
til nærmeste jord
samling
sikkerhedskæde
transducer
sikkerhedskæde
samling
samling
nippel svejset på
blindflange
til nærmeste jord
Flangen, pakningen og de øvrige dele leveres af kunden.
Bøjeligt rør
Dansk
Blindflange
Side DA-8 XLT Serie Transducere - DRIFTSVEJLEDNING A5E32280448
Sammenkoblin
hvid/afskærmn.
sort/strømfør.
sort hvid
Siemens Milltronics kontrolenhed (typisk)
tilslutningsdåse
sort
drain/afskærmn.
hvid
forlæng kablet vha. 18 AWG afskærmet/parsnoet kabel
forlæng kablet vha. RG - 62 A/U koaksial for et optimalt signal/støj-forhold
Direkte forbindelse.
Bemærk: Ved tilslutning til en SITRANS LUT400, en SITRANS LUC500, en MultiRanger
100/200 eller en HydroRanger 200 forbindes den hvide ledning, den sorte ledning og afskærmningsledningen alle separat. Den hvide ledning og afskærmningsledningen MÅ IKKE forbindes med hinanden.
2-Leder-forlængelse
Dansk
Bemærk: Ved tilslutning til en SITRANS LUT400, en SITRANS LUC500, en MultiRanger
100/200 eller en HydroRanger 200 forbindes den hvide ledning, den sorte ledning og afskærmningsledningen alle separat. Den hvide ledning og afskærmningsledningen MÅ IKKE forbindes med hinanden.
Koaksial forlængelse
Bemærk: Transduceren skal jordforbindes som vist i henhold til
sikkerhedsbestemmelserne samt for at isolere den mod elektrisk interferens.
Installation
A5E32280448 XLT Serie Transducere - DRIFTSVEJLEDNING Side DA-9
Installationen må kun foretages af kvalificeret personale og under overholdelse af de
lokalt gældende regler.
Undgå at trække kablet utildækket; før i stedet kablet separat i et jordet metalrør for at
beskytte det mod omgivende elektrisk støj.
Tætn alle gevindsamlinger for at undgå fugtindtrængning.
Undgå at føre kablet i nærheden af højspænding eller stærkstrøm, kontaktorer eller SCR-
styredrev.
Ved tryktætte anvendelser installeres transducerne med en stramning ved håndkraft plus
½ til 1½ ekstra omgang. PTFE-tape eller et andet passende tætningsmiddel kan bruges til at tætne gevindene ved brug i trykanvendelser.
ADVARSEL: Ukorrekt installation kan medføre tab af procestryk.
Dansk
Side DA-10 XLT Serie Transducere - DRIFTSVEJLEDNING A5E32280448
Echomax XLT Betriebsanleitung
Diese Betriebsanleitung ist eine Kurzfassung der wesentlichen Merkmale und Funktionen der Ultraschallsensoren Baureihe Echomax XLT. Das ist auf unserer Webseite verfügbar: www.siemens.com/processautomation
Applikationshandbuch Ultraschallsensoren
. Ein gebundenes
Exemplar können Sie von Ihrer örtlichen Siemens Milltronics Vertretung beziehen.
Wenn Sie Fragen haben, wenden Sie sich bitte an: EU-Bevollmächtigter Siemens Milltronics Process Instruments Siemens AG 1954 Technology Drive, P.O. Box 4225 Industry Sector Peterborough, Ontario, Canada, K9J 7B1 76181 Karlsruhe Email: techpubs.smpi@siemens.com
Deutschland
Copyright Siemens Milltronics Process
Instruments 2013.
Haftungsausschluss
All Rights Reserved
Diese Unterlage ist sowohl in gebundener als auch in elektronischer Form verfügbar. Wir fordern Benutzer auf, genehmigte, gebundene Betriebsanleitungen zu erwer­ben oder die von Siemens Milltronics Pro­cess Instruments entworfenen und genehmigten elektronischen Ausführungen zu betrachten. Siemens Milltronics Process Instruments ist für den Inhalt auszugsweiser oder vollständiger Wiedergaben gebun­dener oder elektronischer Ausführungen nicht verantwortlich.
Wir haben den Inhalt der Druckschrift auf Übereinstimmung mit dem beschriebenen Gerät geprüft. Dennoch können Abweichungen nicht ausgeschlossen werden, so dass wir für die vollständige Übereinstimmung keine Gewähr übernehmen. Die Angaben in dieser Druckschrift werden regelmäßig überprüft, und notwendige Korrekturen sind in den nachfol­genden Auflagen enthalten. Für Verbesser­ungsvorschläge sind wir dankbar. Technische Änderungen vorbehalten.
Deutsch
mmmmm
MILLTRONICS ist eine eingetragene Marke der Siemens Milltronics Process Instruments
Sicherheitstechnische Hinweise
Warnhinweise müssen zu Ihrer persönlichen Sicherheit sowie der Sicherheit Dritter und zur Vermeidung von Sachschäden beachtet werden. Zu jedem Warnhinweis wird der jeweilige Gefährdungsgrad angegeben.
WARNUNG: bezieht sich auf ein Warnsymbol auf dem Produkt und bedeutet, dass bei Nicht-Einhalt der entsprechenden Vorsichtsmaßnahmen Tod, schwere Körperverletzung und/oder erheblicher Sachschaden eintreten können.
WARNUNG: bedeutet, dass bei Nicht-Einhalt der entsprechenden Vorsichtsmaß­nahmen Tod, schwere Körperverletzung und/oder erheblicher Sachschaden ein­treten können.
VORSICHT: bedeutet, dass bei Nicht-Einhalt der entsprechenden Vorsichtsmaßnahmen erheblicher Sachschaden eintreten kann.
Hinweis: steht für eine wichtige Information über das Produkt selbst oder den Teil der
Betriebsanleitung, auf den besonders aufmerksam gemacht werden soll.
A5E32280448 Ultraschallsensoren XLT – BETRIEBSANLEITUNG Seite DE-1
Gerätereparatur und Haftungsausschluss
Der Anwender ist für alle vom Anwender oder seinem Bevollmächtigten durchgeführten Änderungen und Reparaturen am Gerät verantwortlich.
Alle neuen Bauteile sind von Siemens Milltronics Process Instruments Inc. bereit zu stellen.
Reparieren Sie lediglich defekte Bauteile.
Defekte Bauteile dürfen nicht wiederverwendet werden.
mmmmm
Deutsch
Seite DE-2 Ultraschallsensoren XLT – BETRIEBSANLEITUNG A5E32280448
Einleitung
Ultraschallsensor
Sensor­sendefläche
-3db Grenzlinie
Übertragung­sachse, sen­krecht zur Sensorsende­fläche
Dieses Produkt ist vorgesehen zum Gebrauch in Industrie­umgebungen. Bei Verwendung in Wohngebieten kann es zu Stö­rungen von verschiedenen Funkanwendungen kommen.
Die Ultraschallsensoren Baureihe Echomax XLT werden zusammen mit Siemens Milltronics Ultra­schall-Füllstandmessumformern betrieben.
Der Sensor wandelt die elektrische Energie des Sen­deimpulses vom Messumformer in akustische Ener­gie um. Die akustische Energie des Echos wird dann wieder in elektrische Energie für den Messumformer zurückgewandelt.
Die akustische Energie wird von der Sensorsende­fläche nach außen gestrahlt. Ihre Amplitude nimmt dabei mit einer Geschwindigkeit ab, die zum Quadrat des Abstands umgekehrt proportional ist. Die maxi­male Leistung erhält man an der sogenannten Über­tragungsachse, senkrecht zur Sensorsendefläche. An der Stelle, wo die Leistung nur noch halb so groß ist (– 3 dB), entsteht ein Kegel, der die Schallkeule definiert und dessen Mittellinie die Übertragung­sachse darstellt. Sein Durchmesser entspricht dem Schallkegel.
Deutsch
mmmmm
Die XLT Sensoren sind mit einem integrierten Temperaturfühler ausgestattet. Dieser meldet dem Messumformer die Temperatur am Ultraschallsensor.
Allgemeine Richtlinien
WARNUNG: Die Werkstoffe werden entsprechend ihrer chemischen Beständigkeit
(oder Trägheit) für allgemeine Zwecke gewählt. Bei Einsatz in besonderen Umgebungen prüfen Sie vor Installation die chemische Beständigkeit anhand einschlägiger Tabellen.
• Diese Betriebsmittel können in Gasatmosphären der Kategorie 2 (Zone 1) oder Kategorie 3 (Zone 2), sowie in allen Staub-Ex-gefährdeten Bereichen mit leitenden oder nichtleitenden Stäuben jeder Art eingesetzt werden.
• Die Ultraschallsensoren der Baureihe XLT-30 und XLT-60 weisen eine maximale Ober­flächentemperatur von 200 °C auf (Temperaturklasse T3). Die Zulassung dieser Betriebsmit­tel gilt für den Einsatz bei Umgebungstemperaturen von -40 bis 150 °C. Diese Grenzwerte dürfen keinesfalls überschritten werden.
• Die Versorgungsspannung dieser Betriebsmittel muss von einem Schaltkreis kommen, der eine geeignete Sicherung mit einer Kurzschlusskapazität von 4000A enthält. Messumformer von Siemens Milltronics sind mit dieser Sicherung ausgestattet.
• Die Reparatur dieser Geräte darf nur in Übereinstimmung mit den geltenden Verfahrensre­geln durchgeführt werden.
A5E32280448 Ultraschallsensoren XLT – BETRIEBSANLEITUNG Seite DE-3
• Die Zertifizierung der Ultraschallsensoren Baureihe XLT beruht auf folgenden verwendeten
R
II2G1DT3 II2GDT3 EExmIIT3
SIRA 01ATEX5294X
Assembled in Canada with domestic
and imported parts
Siemens Milltronics Process Instruments, Peterborough
Class I, Div 1, Gr.A,B,C,D Class II, Gr. E, F, G
PER DWG # 0-8830004Z-DI-A
TEMP. CODE: T3C
Class I, Div 2, Gr. A, B, C, D Class II, Div 2, Gr. F, G PER DWG # 0-9650016Z-DI-A
0518
Ex mb IIC T3 Gb Ex tb IIIC T200 °C Db DNV 12.0076 X
XLT-xx
ULTRASONIC TRANSDUCER
Serial No.: GYZ / V1034567
Type: FLEXURAL MODE
Enclosure: IP68
Amb. Temp.: – 40°C to 150°C
Max. Input Current: 44.2 mA r.m.s.
Max. Input Voltage: 1.77 V r.m.s.; 250 Vp
KCC-REM-S49
Echomax
OCP 0017
Werkstoffen:
Gehäuse: Aluminium Vergusswerkstoff: Durapot 861-F3 / 864
WARNUNG: Es sind geeignete Maßnahmen zu treffen, um eine Beschädigung
des Geräts im Falle eines Kontakts mit aggressiven Stoffen zu verhindern und die Schutzart zu gewährleisten.
Aggressive Stoffe: z. B. säurehaltige Flüssigkeiten oder Gase, die Metalle angreifen
können, oder Lösungen, die polymerische Stoffe angreifen.
Geeignete Maßnahmen: regelmäßige Kontrollen im Rahmen einer Routineprüfung oder
Aufstellung der Beständigkeit gegen bestimmte Chemikalien anhand des Datenblatts des Materials.
Ein manuelles Ausschalten ist mit dem Leitungsschutzschalter möglich, der kundenseitig am zugehörigen Messumformer installiert ist.
Produktkennzeichnung der Baureihe XLT
mmmmm
Deutsch
WARNUNG:
der Richtlinie 7/23/EG bezeichnet und ist nicht für den Einsatz als Sicherheitsvor­richtung bestimmt.
Dieses Produkt wird als druckhaltendes Ausrüstungsteil im Sinne
Seite DE-4 Ultraschallsensoren XLT – BETRIEBSANLEITUNG A5E32280448
Technische Daten
XLT-30 XLT-60
Messbereich 0,9 - 30 m
(3 - 100 ft)
Frequenz Schallkegel
22 KHz 13 KHz 5 5
Umgebungsbedingungen
Einbauort innen/im Freien innen/im Freien Max. Höhe Umgebungstemperatur
Umgebungsdruck Nordamerika: bis zu 1000 kPa (1 bar, 15 psi)
Verschmutzungsgrad 44
2000 m 2000 m
-40 bis 150 C (-40 bis 300 F)
Europa: bis zu 50 kPa (0,5 bar, 7,25 psi)
Bauart
Gehäuse Aluminium, Edelstahl W.-Nr.
1.4301/304 und Silikon
Montage 1" NPT Gewindeanschluss 1" NPT Gewindeanschluss
1,8 - 60 m (6 - 200 ft)
-40 bis 150 C (-40 bis 300 F)
Aluminium, Edelstahl W.-Nr.
1.4301/304 und Silikon
Kabel
Gewicht** 6,6 kg
Max. Abstand zum Messumformer
Hilfsenergie Betrieb der Sensoren nur an zugelassenen Siemens Milltronics
Zulassungen CE**, CSA, FM, SIRA/CENELEC
* Ungefähres Versandgewicht des Sensors mit Standardkabellänge. ** EMV Bescheinigung auf Anfrage erhältlich
2-adrig geschirmt/verdrillt, 0,5 mm2 (20 AWG), Silikon­Mantel
(14,5 lb) 365 m
(1200 ft)
Messumformern
Angaben zu gegenwärtigen Zulassungen erhalten Sie auf dem Typenschild oder von Siemens Milltronics.
2-adrig geschirmt/verdrillt, 0,5 mm2 (20 AWG), PVC Mantel
6,6 kg (14,5 lb)
365 m (1200 ft)
, INMETRO
Deutsch
mmmmm
A5E32280448 Ultraschallsensoren XLT – BETRIEBSANLEITUNG Seite DE-5
Maßbilder
d
h (nominal)
Klemmschraube zur Erdung (x 1)
1” NPT
Bohrung zur Sicherung des Sensors, Lochdurchm. 9 mm (3/8") (x 2)
XLT-30 XLT-60
h 249 mm (9,8") 324 mm (12,75") d 264 mm (10,4") 335 mm (13,2")
mmmmm
Deutsch
Seite DE-6 Ultraschallsensoren XLT – BETRIEBSANLEITUNG A5E32280448
Montage
Verstellflansch (typisches Modell)
zur nächsten Erdung
Sicherungskette
Erdanschluss
Hinweis: Die Installation darf nur durch qualifiziertes Personal und unter Beachtung der
lokalen, gesetzlichen Bestimmungen durchgeführt werden.
Beachten Sie bei der Sensormontage einen Mindestabstand zum maximalen Materialfül-
lstand entsprechend der Nahbereichsausblendung. Siehe zugehörige Betriebsanleitung des Messumformers.
Bei Applikationen mit Flüssigkeiten ist der Sensor so anzubringen, dass die Übertragung-
sachse senkrecht zur Flüssigkeitsoberfläche steht.
Verwenden Sie bei Applikationen mit Schüttgütern einen Siemens Milltronics Verstell-
flansch, um die Ausrichtung des Sensors zu vereinfachen.
Sichern Sie die Installation durch Anbringen einer Sicherheitskette vom Sensor zur Mon-
tagefläche ab.
Verwenden Sie ggf. einen optionalen Temperaturfühler.
Vorsicht: In der Nähe eines Sensors in Betrieb ist ein geeigneter Ohrenschutz zu tragen.
Von den Ultraschallsensoren Baureihe XLT 60 kann ein gefährlicher Schalldruck aus­gehen. Sie müssen so eingebaut werden, dass die Druckbelastung auf ein ungefährliches Niveau gesenkt wird.
Applikationen mit Schüttgütern
Deutsch
mmmmm
WARNUNG: Konfigurationen mit Verstellflansch sind nicht für Druckbehälter
geeignet.
A5E32280448 Ultraschallsensoren XLT – BETRIEBSANLEITUNG Seite DE-7
Applikationen mit Flüssigkeiten
Platte oder Halterung
Flexible Anschlussleitung
zur nächsten Erdung
Reduziermuffe
Sicherungs­kette
Ultraschall­sensor
Sicherungs­kette
Reduziermuffe
Reduziermuffe
An den Blindflansch
geschweißte
Verschraub ung
zur nächsten Erdung
Flansch, Dichtung und Montagematerial
vom Kunden geliefert.
Abgehängte Montage
mmmmm
Deutsch
Blindflansch
Seite DE-8 Ultraschallsensoren XLT – BETRIEBSANLEITUNG A5E32280448
Loading...
+ 86 hidden pages