Siemens AS 488, TM User Manual

s
Program Library Karlsruhe
Product Information
AS 488/TM
Var.
Descriptors
TELEPERM M , AS 488/TM , Software variant M , UPGRADE , UPDATE
Summary
The present Product Information relates to the System Software Package:
S79220-A0977-A-10-7637
Issue: November, 2001
Name Variant Issue Product no. (MLFB)
AS 488/TM M 02.02 6DS2 410-0XX00-0XA0
6DS2 410-0XX00-0XB0
AS 488/TM
upgrade / update
Description:
Ergänzende Systemdoku. Supplem. System Docu.
This manuals have to be ordered seperate if required.
© SIEMENS AG 1996-2001 Änderungen vorbehalten Subject to alteration Sous réserve de modications Con riserva di modifiche
M 02.02
01.08
AS 488/TM AS 488/TM
German
English
6DS2 410-0XX00-0XC2
C79000-G8000-C700 C79000-G8076-C700
Product Information November, 2001 AS 488/TM M02.02
1 Scope
The product information for the system software M02.01/M01.07 remains valid. The following information represents a supplement.
The delivery consists of:
6DS2 410-0XX00-0XA0 6DS2 410-0XX00-0XB0
6DS2 410-0XX00-0XC2 (Upgrade / Update)
AS 488/TM Memory Card Diskette 3,5" with AS 488/TM
software
Diskette 3,5" with tools for installation
Software contract and
Diskette 3,5" with tools for installation
Software contract
registration card Product Information Product Information
Note on software protection:
The memory card must be considered as part of the CPU. If the memory card is removed during current operation, and if the AS 488/TM enters STOP as a result of the software protection, all modifications to the configuration are lost which have been made in the meantime and which have not been saved, as well as all modified inputs which have been made since the last save operation; I/O modules may be reset to the basic status.
Note to the Diskette IBS-Tools + Hinweise (Commissioning Tools + Notes):
Because of space the data on the IBS tool diskette is existing now as a self-extracting exe file. For extracting please start the file IBS_DISK.EXE! With this the following directory structure is created on your PC / programming device:
...\IBS_DISK.M2\ASBEDIEN ASBEDIEN V1.08 ...\IBS_DISK.M2\ASBEDIEN.NT ASBEDIEN V2.00 for Windows NT ...\IBS_DISK.M2\DOKU Supplementary Documentation (see chapter 1.1) ...\IBS_DISK.M2\PROGRAF AS system file for PROGRAF AS+ (see chapter 1.2)
Copyright © SIEMENS AG 1996-2001. All Rights Reserved.
S79220-A0977-A-10-7637
Page 2 of 18
Product Information November, 2001 AS 488/TM M02.02
1.1 Supplementary Documentation
In addition to the tools required for startup of your AS 488/TM, the commissioning diskette contains a document file for the service terminal (within the directory ASBEDIEN or ASBEDIEN.NT):
ASBEDI_E.doc User description for the Commissioning Terminal (IBS terminal) For further information by seperate ordering to C79000-G8076-C700 please ask your
Siemens sales partner for a document diskette. This information which may be useful when starting up is found in this file and the following files:
DIODEF_E.doc Description of the pin allocations for the DIO interface module (for cabinet status signals, such as door contact, fan, etc.)
BUSINI_E.doc Configuration for operating your AS 488/TM on the CS 275 or PROFIBUS-TM system bus
PERPRO_E.doc Configuring the Teleperm M I/O peripherals DP_PRO_E.doc Configuring the PROFIBUS-DP peripheral
The INI files that need modifying for the parameter settings can be found on the AS 488/TM memory card or the upgrade/update diskette.
DP_BST_E.doc Description of the standard DP driver blocks IP262_E.doc Description of the standard driver blocks for IP262
Please print out these document files and add them to your AS 488/TM documents. Failure to observe the information provided can result in a serious malfunction of the installation. If you do not have the corresponding Windows installation on your PC, your local Siemens representative will be pleased to help you.
Copyright © SIEMENS AG 1996-2001. All Rights Reserved.
S79220-A0977-A-10-7637
Page 3 of 18
Product Information November, 2001 AS 488/TM M02.02
1.2 AS System File for PROGRAF AS+
Your commisioning diskette contains a directory PROGRAF after extracting. This contains the system file AS.SYS required for PROGRAF AS+.
Copy the file AS.SYS into your PROGRAF PC into the directory drv:\PROGRAF\USER\ The system file of the AS 488/TM automation system is then known to PROGRAF AS+.
Carry out your PROGRAF AS configuring in the usual manner.
Note:
From PROGRAF AS+ V3.00 onwards, the AS commands FORM, LA, AR, DI and DEL are also allowed for online structuring. After "LA,name;" PROGRAF AS+ terminates the coupling to AS 488/TM (message "BUS STRUCTURING ABORTED"). The coupling must be re-established after the loading and reset procedure is complete (new ANMS).
Caution:
Under no circumstances should PROGRAF AS+ be stopped while the AS is being reset, as this causes the bus structuring in the AS to remain active. If it should happen nonetheless, the user of PROGRAF AS+ should logon on the same AS.
1.3 Master Type File for COM ET200 / COM PROFIBUS
In the DOKU folder on the IBS tool diskette, there are two files for the ET200 configuration tool COM ET200 or COM PROFIBUS. The master type-file ‘SI8050AX.2MH’ must be copied to the MASTERS directory of the installed COM PROFIBUS. Its contents specify the AS 488/TM as the host system and the module card IF964 as the DP master. The bitmap file ‘AS488TM.BMP’ must be copied into the BITMAPS directory. Once COM PROFIBUS is started, the ‘Read in type files’ menu item or the ‘Read in GSD files’ menu item from within the ‘file’ menu need be activated only once (see also DP_PRO_D.doc).
Note: In the case of COM PROFIBUS, these files are already supplied from V3.1 onwards.
Copyright © SIEMENS AG 1996-2001. All Rights Reserved.
S79220-A0977-A-10-7637
Page 4 of 18
Product Information November, 2001 AS 488/TM M02.02
2 Commissioning
The Memory Card contains the entire system software for AS 488/TM. It responds with the version ID M02.02 .
To perform an upgrade or update from diskette, an AS 488/TM memory card must be available.
The upgrade procedure is performed offline with a PC or a programming device having a compatible MC interface (e.g. PG740).
The update procedure is performed either from the IBS terminal (online) or from a programming device having a compatible MC interface (e.g. PG740).
A description of the upgrade procedure is provided under heading 2.2 in this document, of the update procedure under heading 2.3 .
Caution:
The file RM3_PC1.SYS on the memory card must
never
be deleted or overwritten, as this would mean that the memory card would no longer be bootable!
If this happens nevertheless, the memory card can be restored on a
programming device with the help of the upgrade diskette (see chapter 2.2.1).
Notes:
The V.24 serial interfaces of the AS 488/TM and the PCs are non-isolated. With a distance of more than 10m between the earthable point of the AS and the earthable point of the PC's protective conductor an electrical isolation of the interface has to be planned.
Further electronic switches for multiplication of the PC's serial interfaces are not suitable for the commissioning terminal because of the interruption of telegrams at any point. We recommend the use of the integrated software switch for up to four AS interfaces.
Copyright © SIEMENS AG 1996-2001. All Rights Reserved.
S79220-A0977-A-10-7637
Page 5 of 18
Product Information November, 2001 AS 488/TM M02.02
2.1 Startup by Commissioning Terminal
The extracted IBS tool diskette contains your local tool in the directory ASBEDIEN. Install this on your PC to be used for commissioning of the AS 488/TM according to the installation instructions in the document file ASBEDI_E.DOC in the directory ASBEDIEN, and connect your PC to the serial commissioning interface of your AS 488/TM via a serial interface. For operation under Windows 3.1, a PIF file is delivered with the software. This contains the following settings: run in full screen mode, exclusive foreground execution, foreground priority very high. For operation under Windows 95, the following setting should be specified: idle time activity very low; no screen saver.
Alternatively the new NT version can be used (see chapter 4.2). Using your "Commissioning terminal" installed in this manner and the commands of the
ASBEDIEN input program you can operate and monitor your AS 488/TM for install and diagnostic like an AS 235 and also access all data on the memory card inserted in the AS 488/TM.
Read the parameter files which have to be processed to enable parameterization from the memory card into a file on your PC using the command "COPY_PC ...". You can modify this file on your PC according to your system configuration using the ASCII editors which can be executed under DOS, and then write them back onto your memory card using the ASBEDIEN command "COPY_TM ...".
Note:
Before starting the UPGRADE/UPDATE activities, please ensure that a current backup of the customer's system and any files that are to be modified exists. This will allow the previous software version to be restored in the even of unforeseen circumstances. The files on the memory card are not write protected, so care should be taken when accessing the memory card. To back up the files from the memory card to your archive, use the ASBEDIEN command "COPY_PC ...".
2.1.1 Upgrade / Update Data
The data for the upgrade/update procedure is existing on the upgrade diskette as self­extracting exe file. For extracting please start the file UPGRADE.EXE! If the pre-adjusted path is kept, the following directory structure is created on your PC / programming device:
C:\UPGRADE Upgrade batch C:\UPGRADE\AS_SW.202 AS system software M02.02 C:\UPGRADE\CP5412 Files for operating the system bus with CP5412 C:\UPGRADE\INI Initialization files for restoring C:\UPGRADE\RMOS32 Programs for formatting procedure C:\UPGRADE\Update_M.108 Data for update to M01.08
If a different path as C:\ has been selected while extracting, the environment variable UP_DRIVE has to be changed in UPGRADE.BAT.
Copyright © SIEMENS AG 1996-2001. All Rights Reserved.
S79220-A0977-A-10-7637
Page 6 of 18