Siemens SGen-100A-2P User Manual

Siemens Air-Cooled Generators SGen-100A-2P Series
with ratings from 25 MVA up to 300 MVA
Final assembly of SGen-100A-2P series at Siemens Generator Plant Erfurt, Germany
As one of the international market leaders in the manufacturing of synchronous machines, Siemens has accumulated many decades of experi­ence in the production of generators. Proven two-pole air-cooled generators, from our SGen-100A-2P series, are avail­able for various types of power plants e.g. fossil-fueled power plants – for both gas and steam turbine genera­tors. They can be driven by Siemens turbines or by turbines from other manufacturers.
Answers for energy.
Our air-cooled generators are devel­oped by using state-of-the-art methods. By working with special computer programs for calculation, design and production, we can optimally match the generators to the customers’ needs.
Two-pole three-phase synchronous generator
Outstanding design features of the Siemens air-cooled SGen-100A-2P series generators include:
high efficiency,
low noise emissions, low installation and commissioning costs,
high serviceability and long service life.
For each customer project, a customized generator is developed according to the individual technological specifications, output and customer needs. Using a building-block system, the required generator type is designed by choosing from different diameters and by making adjustments to length. This enables us to supply our customers with generators specially tailored to their requirements.
Siemens two-pole three-phase synchro­nous generators are used as high-voltage generators with a laminated cylindrical rotor or a solid salient-pole rotor. Their rotor windings have direct radial air cool­ing and their stators indirect air cooling.
These generators use either brushless excitation with a stationary field exciter and rotating bridge-connected rectifier or static excitation, whereby the exciter power is taken from static excitation equip­ment and supplied to the rotor winding via the brush gear, carbon brushes and slip rings.
The standard design is IM 7215 according to IEC 34-7 and features pedestal type sleeve bearings which are supplied by the oil system of the prime mover. Other designs are available as options.
2-pole generators are customized for the use on gas and steam turbines. SGen-100A-2P series generators are available with different types of cooling systems: TEWAC (Totally Enclosed Water­to-Air Cooling), CACA (Closed Air-to-Air Cooling) or DAC (Direct Air Cooling, cooling air intake via filter).
11
1
Cross slots
2
Slot wedges
3
14
13
12
10
9
8
7
1
2
5
4
6
3
Rotor winding
4
Rotor coils
5
Rotor shaft
6
Multi-piece liner
7
Insulation tube
8
Radial / axial leads
9
Slip rings
10
Integrated blower hub
11
Blower blades
12
End plate
13
Retaining ring
14
Key assembly