Siemens SCALANCE M874-2, SCALANCE M874, SCALANCE M874-3, SCALANCE M876, SCALANCE M876-3 Operating Instructions Manual

SCALANCE M874, M876

___________________
___________________
___________________
___________________
___________________
___________________
___________________
SIMATIC NET
Operating Instructions
07/2014
C79000
Preface
Description of the device
1
Installation
2
Connecting up
3
Dimension drawing
4
Technical specifications
5
Approvals
A
-G89760-C331-03
Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY
Order number: C79000-G8976-C331
Copyright © Siemens AG 2013 - 2014. All rights reserved
Legal information
Warning notice system
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
The product/system described in this documentation may be operated only by task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
for the specific
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
07/2014 Subject to change

Preface

Purpose of the Operating Instructions
Validity of the manual
Naming of the devices
Classification
Description
Terms used
SCALANCE M-800 product line, the term M-800 is used.
group is used.
M874-3
Further documentation
These compact operating instructions contain information with which you will be able to install and connect up a device of the SCALANCE M874, M876 product line. The configuration and the integration of the device in a network are not described in these instructions.
These operating instructions apply to the following devices:
SCALANCE M874-2
SCALANCE M874-3
SCALANCE M876-3
Product line For all devices and variants of all product groups within the
Product group For all devices and variants of a product group, only the product
Device For a device, only the device name is used. M876-3
System manual "Industrial Ethernet"
The system manual contains information on other SIMATIC NET products that you can operate along with the devices of this product line in an Industrial Ethernet network.
There, you will find among other things optical performance data of the communications partner that you require for the installation.
The "SIMATIC NET Industrial Ethernet" system manual can be found on the Internet pages of Siemens Industry Online Support under the following entry ID:27069465 (http://support.automation.siemens.com/WW/view/wn/27069465
M-800
M87x
M874-2
)
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
3
Preface
SIMATIC NET manuals
"Passive network components" system manual
This system manual contains installation instructions for several of the most common components and guidelines for setting up networked automation plants in buildings.
The "Passive Network Components" system manual can be found on the Internet pages of Siemens Industry Online Support under the following entry ID:84922825 (http://support.automation.siemens.com/WW/view/en/84922825
)
You will find SIMATIC NET manuals on the Internet pages of Siemens Industry Online Support:
using the search function:
Link to Siemens Industry Online Support (http://support.automation.siemens.com/
Enter the entry ID of the relevant manual as the search item.
In the navigation panel on the left hand side in the area "Industrial Communication":
Link to the area "Industrial Communication" (http://support.automation.siemens.com/WW/view/en/10805878/133400
Go to the required product group and make the following settings: tab "Entry list", Entry type "Manuals"
You will find the documentation for the SIMATIC NET products relevant here on the data medium that ships with some products:
Product CD / product DVD
SIMATIC NET Manual Collection
You will find the order numbers for the Siemens products of relevance here in the following catalogs:
SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI
SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog
ST 70
Industry Mall - catalog and ordering system for automation and drive technology, Online catalog (http://eb.automation.siemens.com/
You can request the catalogs and additional information from your Siemens representative.
)
)
)
SCALANCE M874, M876
4 Operating Instructions, 07/2014, C79000-G89760-C331-03
Preface
Security messages
Note
Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions. You will find information in:
(
en
Here, you can register for a product
For the safe operatio automation components into an overall IT security concept for the entire plant/machine, which corresponds to the state
Products from other manufacturers that are being used must also be taken into account.
License conditions
Note Open source software
Read the license
SIMATIC NET glossary
Our products are also continuously
http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang=
)
-specific newsletter.
n of a plant/machine, however, it is also necessary to integrate the
-of-the-art IT technology. You will find information on this in:
(http://www.siemens.com/industrialsecurity)
conditions for open source software carefully before using the product.
You will find license conditions in the following documents on the supplied data medium:
DOC_OSS-SCALANCE-M_74.pdf
DC_LicenseSummaryScalanceM874_76.htm
DC_LicenseSummaryScalanceM876_76.htm
Explanations of many of the specialist terms used in this documentation can be found in the SIMATIC NET glossary.
You will find the SIMATIC NET glossary here:
SIMATIC NET Manual Collection or product DVD
The DVD ships with certain SIMATIC NET products.
On the Internet under the following entry ID:
50305045 (http://support.automation.siemens.com/WW/view/en/50305045
)
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
5
Preface
SCALANCE M874, M876
6 Operating Instructions, 07/2014, C79000-G89760-C331-03

Table of contents

Preface ................................................................................................................................................... 3
1 Description of the device ......................................................................................................................... 9
2 Installation ............................................................................................................................................ 23
3 Connecting up ....................................................................................................................................... 31
4 Dimension drawing ............................................................................................................................... 45
1.1 Product characteristics ................................................................................................................... 9
1.1.1 SCALANCE M874-2, M874-3 ........................................................................................................ 9
1.1.2 SCALANCE M876-3 .................................................................................................................... 10
1.2 Unpacking and checking .............................................................................................................. 12
1.3 Accessories .................................................................................................................................. 13
1.4 LED display .................................................................................................................................. 14
1.4.1 SCALANCE M874-2, M874-3 ...................................................................................................... 14
1.4.2 SCALANCE M876-3 .................................................................................................................... 16
1.5 SET button ................................................................................................................................... 18
1.6 C-PLUG and KEY-PLUG ............................................................................................................. 20
2.1 Securing the housing ................................................................................................................... 24
2.2 Wall mounting .............................................................................................................................. 25
2.3 Installing on the DIN rail ............................................................................................................... 26
2.4 Installing on the S7-300 standard rail .......................................................................................... 27
2.5 Installing on the S7-1500 standard rail ........................................................................................ 28
3.1 Safety when connecting up .......................................................................................................... 31
3.2 SIM card ....................................................................................................................................... 33
3.3 Power supply ................................................................................................................................ 34
3.4 Grounding .................................................................................................................................... 36
3.5 Digital input/output ....................................................................................................................... 37
3.6 Antennas ...................................................................................................................................... 39
3.7 Ethernet port ................................................................................................................................ 42
3.8 Replacing the PLUG .................................................................................................................... 43
4.1 SCALANCE M874-2, M874-3 ...................................................................................................... 45
4.2 SCALANCE M876-3 .................................................................................................................... 47
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
7
Table of contents
5 Technical specifications ........................................................................................................................ 49
A Approvals ............................................................................................................................................. 59
Index .................................................................................................................................................... 71
5.1 SCALANCE M874-2 .................................................................................................................... 49
5.2 SCALANCE M874-3 .................................................................................................................... 52
5.3 SCALANCE M876-3 .................................................................................................................... 55
A.1 Note - products in general without shipbuilding approvals ......................................................... 59
A.2 INSTALLATION ........................................................................................................................... 60
A.3 EU declaration of conformity ....................................................................................................... 62
A.4 ATEX ........................................................................................................................................... 64
A.5 IECEx .......................................................................................................................................... 64
A.6 EMC directive .............................................................................................................................. 65
A.7 RoHS directive ............................................................................................................................ 65
A.8 RCM / C-TICK ............................................................................................................................. 65
A.9 FM certification ............................................................................................................................ 66
A.10 Conformity with FCC ................................................................................................................... 67
A.11 UL certification (product safety) .................................................................................................. 69
A.12 UL HAZ. LOC certification (explosion protection) ....................................................................... 69
SCALANCE M874, M876
8 Operating Instructions, 07/2014, C79000-G89760-C331-03
1
1.1

Product characteristics

1.1.1

SCALANCE M874-2, M874-3

Interfaces
Functionality
M874-2 M874-3
SMA antenna connector
Ethernet interface
2 x RJ-45 10 / 100 Mbps
Digital input/output
1/1
Scope of delivery
Note Not included with the product
The following components do not ship with the product:
Use the SIM card from the chosen mobile wireless provider
Connectors for external antennas 1
The following components ship with the product:
One device
A 5-pin terminal block for the power supply
A 2-pin terminal block for the digital output
A 2-pin terminal block for the digital input
Product CD
KEY-PLUG / C-PLUG
You will find more detailed information in "C-PLUG and KEY-PLUG (Page 20)".
Antennas
You will find more detailed information in "Accessories (Page 13)".
SIM card
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
9
Description of the device
Order numbers
Type
Order number
Description
(EDGE)
(HSPA+)
1.1.2

SCALANCE M876-3

Interfaces
Functionality
M876-3
SMA antenna connector
Ethernet interface
4 x RJ-45 10 / 100 Mbps
Digital input/output
1/1
Scope of delivery
Note Not included with the product
The following components do not ship with the product:
Use the SIM card from the chosen mobile wireless provider
1.1 Product characteristics
SCALANCE M874-2 6GK5 874-2AA00-2AA2 Mobile wireless router for 2G
SCALANCE M874-3 6GK5 874-3AA00-2AA2 Mobile wireless router for 3G
Connectors for external antennas 2
The following components ship with the product:
One device
A 5-pin terminal block for the power supply
A 2-pin terminal block for the digital output
A 2-pin terminal block for the digital input
Product CD
KEY-PLUG / C-PLUG
You will find more detailed information in "C-PLUG and KEY-PLUG (Page 20)".
Antennas
You will find more detailed information in "Accessories (Page 13)".
SIM card
SCALANCE M874, M876
10 Operating Instructions, 07/2014, C79000-G89760-C331-03
Description of the device
Order numbers
Type
Order number
Description
with antenna diversity
1.1 Product characteristics
SCALANCE M876-3 6GK5876-3AA02-2BA2 Mobile wireless router for 3G
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
11
Description of the device
1.2
Unpacking and checking
Unpacking and checking
WARNING
Do not use any parts that show evidence of damage

1.2 Unpacking and checking

If you use damaged parts, there is no guarantee that the device will function according to the specification.
If you use damaged parts, this can lead to the following problems:
Injury to persons
Loss of the approvals
Violation of the EMC regulations
Use only undamaged parts.
1. Make sure that the package is complete.
2. Check all the parts for transport damage.
SCALANCE M874, M876
12 Operating Instructions, 07/2014, C79000-G89760-C331-03
Description of the device
1.3
Accessories
Antennas
Type
Properties
Order number
tape
1900 MHz and for UMTS with 850 / 900 / 1800 /
bracket, screws, wall plugs

1.3 Accessories

You will find further information on the accessories program for the M874 in the Industry Mall (https://eb.automation.siemens.com/goos/WelcomePage.aspx?regionUrl=/en&language=en
)
.
ANT 794-3M Flat antenna for GSM networks, for tri-band
with 900 / 1800 / 1900 MHz; weatherproof for indoor and outdoor areas; 1.2 m connecting cable connected permanently to the antenna; SMA connector, including adhesive mounting
ANT794-4MR Omnidirectional antenna for GSM and UMTS
networks. For GSM with 850 / 900 / 1800 /
1900 / 2200 MHz; omnidirectional; weatherproof for indoor and outdoor areas; 5 m connecting cable connected permanently to the antenna; SMA connector, including installation
6NH9870-1AA00
6NH9860-1AA00
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
13
Description of the device
1.4
LED display
1.4.1

SCALANCE M874-2, M874-3

LED
Status
Meaning

1.4 LED display

F OFF
ON
Flashing The bootloader waits in this state for a new firmware file that you can
L
SCALANCE M874, M876
OFF
ON
No fault/error.
The device is starting up or an error has occurred. Possible errors/faults:
Wrong PIN number
download using TFTP.
Device turned off, no power supply.
Device turned on, power supply present.
14 Operating Instructions, 07/2014, C79000-G89760-C331-03
Description of the device
LED
Status
Meaning
1.4 LED display
SC
Q OFF
OFF
ON
ON
Flashing Signal strength poor: -89 dBm to -109 dBm
On
ON
OFF
ON
SIM card OK, no connection.
Wrong PIN number / SIM card error
Connection established
No reception Signal strength: < -109 dBm
Signal strength medium: -73 dBm to -89 dBm
Signal strength good: > -73 dBm
VPN not established
VPN established
P1/P2 OFF
ON
ON
DI OFF
ON
DO OFF
ON
Ethernet connection to local computer or LAN not established
Ethernet connection to local computer or LAN established
Device receiving / sending data
Digital input inactive
Digital input active.
Digital output inactive
Digital output active.
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
15
Description of the device
1.4.2

SCALANCE M876-3

LED
Status
Meaning
1.4 LED display
F OFF
ON
Flashing The bootloader waits in this status for a new firmware file that you can
L
SCALANCE M874, M876
OFF
ON
No fault/error.
The device is starting up or an error has occurred. Possible errors/faults:
Wrong PIN number
download using TFTP.
Device turned off, no power supply.
Device turned on, power supply present.
16 Operating Instructions, 07/2014, C79000-G89760-C331-03
Description of the device
LED
Status
Meaning
1.4 LED display
SC
Q OFF
OFF
ON
ON
Flashing Signal strength poor: -89 dBm to -109 dBm
On
ON
OFF
ON
SIM card OK, no connection.
Wrong PIN number / SIM card error
Connection established
No reception Signal strength: < -109 dBm
Signal strength medium: -73 dBm to -89 dBm
Signal strength good: > -73 dBm
VPN not established
VPN established
P1 P2 P3 P4
DI OFF
DO OFF
OFF
ON
ON
ON
ON
Ethernet connection to local computer or LAN not established
Ethernet connection to local computer or LAN established
Device receiving / sending data
Digital input inactive
Digital input active.
Digital output inactive
Digital output active.
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
17
Description of the device
1.5
SET button

1.5 SET button

With a SCALANCE M-800, the SET button is on the front of the housing beside the LED display.
The SET button has the following functions:
Restart
Hold down the button for longer than 3 seconds to run a restart.
Loading new firmware
If the normal procedure with the "Load & Save" menu of Web Based Management does not work, the reset button can be used to load new firmware. This situation can occur if there is a power outage during the normal firmware update.
– Hold down the button until the red fault LED (F) starts to flash after approximately 3
seconds.
– Now release the button. The bootloader waits in this status for a new firmware file that
you can download using TFTP.
You will find more information in the section "Service and Maintenance" in the SCALANCE M-800 Web Based Management configuration manual.
SCALANCE M874, M876
18 Operating Instructions, 07/2014, C79000-G89760-C331-03
Description of the device
1.5 SET button
Reset to factory defaults
– Hold down the button until the red fault LED (F) stops flashing after approximately 10
seconds and is permanently lit.
– Now release the button and wait until the fault LED (F) goes off again. The device then
starts automatically with the factory settings and can be reached via the IP address
192.168.1.1.
You will find more information in the section "Service and Maintenance" in the SCALANCE M-800 Web Based Management configuration manual.
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
19
Description of the device
1.6
C-PLUG and KEY-PLUG
How it works
NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!

1.6 C-PLUG and KEY-PLUG

The C-PLUG or KEY-PLUG is used to transfer the configuration of the old device to the new device when a device is replaced.
A PLUG may only be removed or inserted when the device is turned off. The device checks whether or not a PLUG is present at one second intervals. If it is detected that the PLUG was removed, there is a restart.
If a valid KEY-PLUG was inserted in the device, the device changes to a defined error state following the restart.
When the new device starts up with the PLUG, it then continues automatically with exactly the same configuration as the old device. One exception to this can be the IP configuration if it is set over DHCP and the DHCP server has not been reconfigured accordingly.
A reconfiguration is necessary if you use functions based on MAC addresses. If an incorrect PLUG, for example from another product or a damaged PLUG is inserted, the device signals an error with the "F" LED.
You can either remove the PLUG again or select the option to reformat the PLUG.
In terms of the PLUG, devices work in two modes:
Without PLUG
The device stores the configuration in internal memory. This mode is active when no PLUG is inserted.
With PLUG
The configuration stored on the PLUG is displayed in WBM in "Information > PLUG". If changes are made to the configuration, the device stores the configuration directly on the PLUG and in the internal memory. This mode is active as soon as a PLUG is inserted. As soon as the device is started with a PLUG inserted, the device starts up with the configuration data on the PLUG.
SCALANCE M874, M876
20 Operating Instructions, 07/2014, C79000-G89760-C331-03
Description of the device
License information on the KEY-PLUG
Order numbers
Type
Order number
Description
configuration data
the configuration data.
See also
1.6 C-PLUG and KEY-PLUG
In addition to the configuration, the KEY-PLUG also contains a license that allows the use of Siemens Remote Services.
C-PLUG 6GK1900-0AB00 Exchangeable storage medium (32 MB) for the
KEY-PLUG M800 SRS 6GK5908-0PA00 Exchangeable storage medium (256 MB) to
enable Siemens Remote Services and receiving
Replacing the PLUG (Page 43)
SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03
21
Description of the device
1.6 C-PLUG and KEY-PLUG
SCALANCE M874, M876
22 Operating Instructions, 07/2014, C79000-G89760-C331-03
Loading...
+ 50 hidden pages