siemens.com/safety-integrated
Reliable protective door monitoring is one of the most common safety
requirements that has to be provided for machines: hazardous machine
movements must be reliably brought to a standstill when a protective door is
opened. SIRIUS 3SK safety relays from Siemens provide the perfect solution for
every safety application on the basis of standard DIN EN ISO 14119: mechanical
protective door monitoring with standard and safety position switches, noncontact protective door monitoring with magnetically-operated switches,
protective door monitoring with non-contact RFID safety switches for the ultimate
protection against tampering.
Customer benefits/application
Mechanical protective door monitoring with SIRIUS 3SE5 position switches
- Modular design for versatile use (different actuator heads)
- Quick connect system and simple plug-in installation
- Suitable for higher currents
- Safe shutdown without action by the machine controller
- Absolute protection against electromagnetic interference
- 3D-coded actuators rule out the possibility of simple tampering
Non-contact protective door monitoring with coded 3SE6 magneticallyoperated switches
- Two safety contacts + 1 signaling contact (diagnostics option)
- Long service life due to wear-free switching
- Particularly suitable for areas exposed to contamination, cleaning
and disinfecting
Non-contact protective door monitoring with 3SE63 RFID safety switches
offer additional benefits:
- Protection against tampering thanks to individual coding
- Extensive diagnostics functions provided by LEDs increase plant
availability
- High IP69K degree of protection for use in extreme environmental
conditions
Protective door monitoring
Simple and safe to
implement
Basic information
Overview of options for protective door monitoring, tamper-proof, up to SIL3/PL e
Example of product selection for implementing protective door monitoring
1. Mechanical protective door monitoring with 3RM1 motor starter
EMERGENCY STOP mushroom pushbutton in enclosure, 2 NC
Pushbutton, green, in gray enclosure, 1 NO
3SU1851-0NB00-2AA2
3SU1801-0AB00-2AB1
Standard position switch
Safety position switch
Actuator for safety position with transverse fixing
3SE5212-0CK21
3SE5212-0RV40
3SE5000-0AV03
3SK1 input extension, 24 V DC
3SK1 device connector
3SK1 safety relay, basic unit Advanced
3RM1 motor starter (direct-on-line starter) Safety, 24 V DC
3SK1 device termination connector
3SK1220-1AB40
3ZY1212-1BA00
3SK1122-1AB40
3RM1101-1AA04
3ZY1212-2FA00
2. Non-contact protective door monitoring with magnetically-operated switch and
two 3RT2 contactors
Pushbutton, green, in gray enclosure, 1 NO
3SK1 safety relay, basic unit Standard, 24 V AC/DC
Switching component, right-hand door hinge, 3m cable
Solenoid, right-hand door hinge
3SE6627-2CA04
3SE6714-2CA
2 contactors, 24 V DC, 1 NC, 3 kW
2. Non-contact protective door monitoring with RFID and two 3RT2 contactors
Pushbutton, green, in gray enclosure, 1 NO
3SK2 safety relay, basic units, 24 V DC
Non-contact RFID safety switch, family-coded
Actuator for RFID switches
Cable for RFID switch, 3 m
2 contactors, 24 V DC, 1 NC, 3 kW
• SIRIUS Safety Integrated application manual: https://support.industry.siemens.com/cs/ww/de/view/81366718
• Example application for RFID switches: https://support.industry.siemens.com/cs/ww/de/view/109485646
• Podcast on the subject of position switches: http://sie.ag/2d9cjKZ
Published by For the U.S. published by
Siemens AG Siemens Industry Inc.
Smart Infrastructure 100 Technology Drive
Control Products Alpharetta, GA 30005
Werner-von-Siemens-Str. 48-50
92224 Amberg, Germany United States
Subject to change without prior notice
05/19
© Siemens 2016
Changes and errors excepted. The information
provided in this brochure contains merely
descriptions or characteristics of performance
which in case of actual use do not always
apply as described or which may change as a
result of further development of the products.
An obligation to provide the respective
characteristics shall only exist if expressly
agreed in the terms of contract.