Power supply
LOGO!Power
Operating Instructions
6EP1311-1SH03 5 V/3 A 6EP1311-1SH13 5 V/6.3 A 6EP1321-1SH03 12 V/1.9 A 6EP1322-1SH03 12 V/4.5 A 6EP1351-1SH03 15 V/1.9 A 6EP1352-1SH03 15 V/4 A 6EP1331-1SH03 24 V/1.3 A 6EP1332-1SH43 24 V/2.5 A 6EP1332-1SH52 24 V/4 A
02.2011
C98130-A7560-A999-1-7619
Overview
Description, device design, dimension drawing
1
Mounting/Disassembly
2
Mounting position, installation clearances
3
Installation
4
Applications
5
Technical data
6
EMC
7
Ambient conditions
8
Safety
9
Certifications
10
MTBF
11
Environment
12
Accessories
13
Service & Support
14
Legal information
Legal information Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY
C98130-A7560-A999-1-7619 Ⓟ 02/2011
Copyright © Siemens AG 2011. Technical data subject to change
LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
3
Overview
Description
LOGO!Power are powerful power supplies, which - thanks to their flat stepped profile - are extremely flexible for use in a host of applications (for example, in installation distribution boards). The 12 V and 24 V versions are ideal as power supplies for the LOGO! logic modules.
The key benefits of the product include:
● Flat LOGO! mechanical design
● Wide-range input for voltages from 85 to 264 V AC and operation with DC voltage
● Adjustable output voltage
● Green LED for "Output voltage OK"
● Ambient temperature -20 °C to +70 °C (derating from +55 °C)
● Constant current under overload conditions for reliable connection of difficult loads
● When you turn on the power supply, a power reserve of 1.5 times rated current is available for typ. 200 ms
● Export benefits thanks to global certifications
The following device options are available:
Input Output Width 100 - 240 V 1-phase AC 5 V DC / 3 A 54 mm 100 - 240 V 1-phase AC 5 V DC / 6.3 A 72 mm 100 - 240 V 1-phase AC 12 V DC / 1.9 A 54 mm 100 - 240 V 1-phase AC 12 V DC / 4.5 A 72 mm 100 - 240 V 1-phase AC 15 V DC / 1.9 A 54 mm 100 - 240 V 1-phase AC 15 V DC / 4 A 72 mm 100 - 240 V 1-phase AC 24 V DC / 1.3 A 54 mm 100 - 240 V 1-phase AC 24 V DC / 2.5 A 72 mm 100 - 240 V 1-phase AC 24 V DC / 4 A 90 mm
Overview
LOGO!Power
4 Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
Safety and warning information
WARNING
When operating electrical devices, it is inevitable that certain components will carry dangerous voltages.
Therefore, failure to handle the units properly can result in death or serious physical injury as well as extensive property damage.
Only appropriately qualified personnel may work on or in the vicinity of this equipment.
Perfect, safe, and reliable operation of this equipment is dependent on proper transportation, storage, installation and mounting.
Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again.
If this instruction is not observed, touching live parts can result in death or serious injury.
Disposal guidelines
Packaging and packaging aids can and should always be recycled.
The product itself may not be disposed of as domestic refuse.
Overview
LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
5
Ordering data
LOGO!Power regulated power supply
6EP1311-1SH03 5 V / 3 A 6EP1311-1SH13 5 V / 6.3 A 6EP1321-1SH03 12 V / 1.9 A 6EP1322-1SH03 12 V / 4.5 A 6EP1351-1SH03 15 V / 1.9 A 6EP1352-1SH03 15 V / 4 A 6EP1331-1SH03 24 V / 1.3 A 6EP1332-1SH43 24 V / 2.5 A 6EP1332-1SH52 24 V / 4 A
Overview
LOGO!Power
6 Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
7
Table of contents
Overview.................................................................................................................................................... 3
1 Description, device design, dimension drawing ......................................................................................... 9
1.1 Device description..........................................................................................................................9
1.2 Connections and terminal designation.........................................................................................10
1.3 Potentiometer...............................................................................................................................10
1.4 Status displays and signaling.......................................................................................................11
1.5 Block diagram ..............................................................................................................................11
1.6 Dimensions and weight ................................................................................................................12
2 Mounting/Disassembly............................................................................................................................. 13
3 Mounting position, installation clearances................................................................................................ 15
3.1 Standard mounting position .........................................................................................................15
3.2 Other mounting positions .............................................................................................................15
4 Installation ............................................................................................................................................... 17
4.1 Line-side connection ....................................................................................................................17
4.2 Output-side connection ................................................................................................................18
5 Applications ............................................................................................................................................. 19
5.1 Parallel connection to increase power rating ...............................................................................19
5.2 Parallel connection for redundancy .............................................................................................20
5.3 Series connection for increased voltage......................................................................................21
5.4 Protection against short-time voltage dips ...................................................................................21
6 Technical data ......................................................................................................................................... 23
6.1 Input .............................................................................................................................................23
6.2 Output ..........................................................................................................................................25
6.3 Closed-loop control ......................................................................................................................27
6.4 Efficiency and power loss ............................................................................................................27
6.5 Protection and monitoring ............................................................................................................28
7 EMC ........................................................................................................................................................ 29
8 Ambient conditions ...........................................
....................................................................................... 31
9 Safety ...................................................................................................................................................... 33
10 Certifications............................................................................................................................................ 35
11 MTBF....................................................................................................................................................... 37
Table of contents
LOGO!Power
8 Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
12 Environment ............................................................................................................................................ 39
13 Accessories ............................................................................................................................................. 41
14 Service & Support.................................................................................................................................... 43
LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
9
Description, device design, dimension drawing
1
1.1 Device description
LOGO!Power are primary switched-mode power supplies for connection to a 1-phase AC system or to DC systems. An electronically regulated DC voltage that can be set via a potentiometer is available at the output of the device. The output of the device is isolated, no-load proof and short-circuit proof. The LED display indicates the operating status.
Line input DC output Potentiometer Indicator light (output voltage OK) DIN rail slider Natural convection Clearance above/below
Figure 1-1 Structure
Description, device design, dimension drawing
1.2 Connections and terminal designation
LOGO!Power
10 Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
1.2 Connections and terminal designation
The line input terminals can be used to establish the connection to supply voltage. The output terminals
to be supplied are used to connect the loads (see also Section
Installation (Page 17)).
Connections and terminal designations
Supply input L1, N
One screw terminal each for 0.5 to 2.5 mm²
Output +
2 screw terminals for 0.5 mm to 2.5 mm²
Output –
2 screw terminals for 0.5 mm to 2.5 mm²
Figure 1-2 Terminal data
1.3 Potentiometer
The potentiometer on the front of the device is used to set the output voltage. The output voltage is set to the rated value at the factory and can be set within certain limits; for example, to compensate voltage drops across long supply lines to the connected load.
Type Factory setting Setting range 5 V 5 V 4.6 to 5.4 V 12 V 12 V 10.5 to 12.9 V 15 V 15 V 13.9 to 16.1 V 24 V 24 V 22.2 to 26.4 V
WARNING
Actuation of the potentiometer is allowed only be means of an insulated screwdriver.
Notes on potentiometer operation (such as a screwdriver, torque) refer to Chapter Connections and terminal designation (Page 10), Fig. Terminal data.
Description, device design, dimension drawing
1.4 Status displays and signaling
LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
11
1.4 Status displays and signaling
Status display Green LED for output voltage OK
Signaling LED lights up green
Normal operation, output voltage in setpoint range
LED off
Supply voltage missing or output voltage is not in setpoint range due to overload
1.5 Block diagram
Figure 1-3 Block diagram
Description, device design, dimension drawing
1.6 Dimensions and weight
LOGO!Power
12 Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
1.6 Dimensions and weight
Figure 1-4 Dimension drawing
Dimensions (W × H × D) Weight 54 × 90 × 55 mm Approx. 160 g 72 × 90 × 55 mm Approx. 250 g 90 × 90 × 55 mm Approx. 320 g
LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619
13
Mounting/Disassembly
2
WARNING
The LOGO!Power power supplies are built-in units. They must be installed in a casing or control cabinet to which only qualified personnel have access.
The devices can be snapped onto standard mounting rail EN 60715 35x7.5/15 for installation in a control cabinet.
Installation
To mount the device, position it with the mounting rail guideway at the upper edge of the DIN rail and press down to lock it into place. If this is too difficult, press slider
at the same
time, as described for "Disassembly".
Deinstalling
To remove, pull up the slider
using a screwdriver and disengage the device at the
bottom edge of the DIN rail. Then you can remove the device from the upper edge of the DIN rail.
Figure 2-1 Deinstalling
WARNING
If the device is to be used in a hazardous area (Ex II 3G Ex nA IIC T3) it must be installed in a distributor box with degree of protection IP54 or higher.
Mounting/Disassembly
LOGO!Power
14 Operating Instructions, 02.2011, C98130-A7560-A999-1-7619