I. TOC-Control V Main Menu
1. Measurement
1.1 Sample Table Editor
1.2 H/W Settings
1.3 Online Manual
2. Administration
2.1 System Administrator
2.2 Audit Trail
2.3 User Authentication
2.4 Others
II. Sample Table Editor
1. Create a calibration curve
2. Create a method
3. Create a sample run
4. Schedule File
4.1 Create a new schedule file
4.2 Export the sample table as schedule file
4.3 Insert a schedule
5. Vial Number
III. Analysis
1. Connect the system
2. Start the analysis
3. Sample Window
4. Edit Mode
5. Stop the analysis
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
3
3
3
5
6
6
6
6
7
8
9
13
15
18
18
18
18
19
20
20
20
21
22
22
![](/html/2b/2bbb/2bbb71fb181e91bf909843bc9a4b31ade8d800283781c01dc46d673260292a86/bg3.png)
TOCV-CP_IMshort_Control-ver-2_Rev07F Page 3 of 22
(Software version ≥ 2.00) effective date: September 2007
I. Main Menu
Start TOC-Control V
Main Menu
STARTPROGRAMSTOC-Control V TOC-Control V or
double-click on the TOC-Control V icon (Desktop)
1 Measurement
1.1 Sample Table Editor
- to create and edit methods, calibration curves and sample measurement sequences.
Click on the “Sample Table Editor” button
Enter exact user name and password
Sample Table Editor opens to start the TOC instrument
1.2 H/W Settings
- to configure a new system
- to view or modify the instrument settings
Click on the “H/W Settings” button
Enter exact user name and password
1.2.1 New System
- to configure a new instrument.
Click on the “Create a New Setting” button
Instrument Setup Wizard-1 : Basic System Information
Enter a unique name (max. 32 characters)
Enter the serial number of the TOC-instrument (mentioned on the
instrument label)
![](/html/2b/2bbb/2bbb71fb181e91bf909843bc9a4b31ade8d800283781c01dc46d673260292a86/bg4.png)
TOCV-CP_IMshort_Control-ver-2_Rev07F Page 4 of 22
(Software version ≥ 2.00) effective date: September 2007
Name of current user is automatically entered, if entered it cannot
be edited
Current date is automatically entered and cannot be edited
Enter additional system information (optional)
Instrument Setup Wizard-2 : Instrument Options
Select the installed instrument components (TOC, ASI, SSM,
Sparge Kit and 8-port Sampler)
[The selected options determine which Instrument Setup Wizard
screens will subsequently be displayed.]
Instrument Setup Wizard-3 : Instrument Parameters
Select the catalyst type (Regular, High Sense or TC/TN)
Tubing Diameter
Regular
Suspended Particle
Select the diameter size of the sample injection tubing.
0.5 mm diameter
0.8 mm diameter
Select the cell of the NDIR detection
(Long as default, short for SSM measurements)
This item sets the TC furnace temperature
If this item is selected, a buzzer will sound with the press of each
instrument key
Auto regeneration of
IC solution
If this item is selected, IC reagent will automatically be generated in
special situations (Please refer to the User Manual)
Enable ready status
check
Select this option to enable the Ready Status Check function
[recommended, thus software always verifies Ready Status of
instrument prior to starting measurement]
If this item is selected, the power to the optional TNM-1 is turned
on.
Instrument Setup Wizard-4 : ASI parameters
Select ASI tray type (24 ml, 40 ml or 125 ml vial)
Select the needle type. (only active if Sparge Kit was selected)
Select the number of times (0-10) the outside of the needle to be
washed with dilution water, after each sample analysis
Select the number of times (0-10) the flow lines to be washed with
dilution water from the needle to the injection tube, at the
completion of the sample sequence
Select this option to rinse the sampling needle with dilution water
between each sample.
Rinse after acid
addition
Select this option to rinse the sampling needle after each acid
addition.
Select this option to use the magnetic stirrer. (if installed)
![](/html/2b/2bbb/2bbb71fb181e91bf909843bc9a4b31ade8d800283781c01dc46d673260292a86/bg5.png)
TOCV-CP_IMshort_Control-ver-2_Rev07F Page 5 of 22
(Software version ≥ 2.00) effective date: September 2007
Instrument Setup Wizard-5 : SSM parameters
Select this option to heat the TC furnace of SSM
Select this option to heat the IC furnace of SSM
Instrument Setup Wizard-6 : Communication parameters
Select the communication port
Cannot be edited by the user .
[determined by the hardware, automatically set based on Com Port]
The system configuration is created and the newly created system
configuration is displayed as an icon in the H/W Setting List
window.
1.2.2 H/W Setting List
- to view or modify instrument parameters of already defined systems
Select the “Instrument/System” icon and press “Open” to open the
instrument properties
Select the “Instrument/System” icon and press “Delete” to delete the
instrument system
Press “Close” to close the H/W Setting List window.
1.3. Online Manual
- to open the user manual as PDF format
2 Administration
![](/html/2b/2bbb/2bbb71fb181e91bf909843bc9a4b31ade8d800283781c01dc46d673260292a86/bg6.png)
TOCV-CP_IMshort_Control-ver-2_Rev07F Page 6 of 22
(Software version ≥ 2.00) effective date: September 2007
2.1 System Administration
2.1.1 System Policy
- to check the security functions, activation of them is done during the installation
2.1.2 S/W Validation
- to verify that the TOC-Control V program files have not been modified since
installation
2.2 Audit Trail
2.2.1 Log Browser
- to open the audit trail database (please refer to the Administration Manual)
2.2.2 Add a Log Event
- to add an event to the Log Browser
2.3 User Authentication
2.3.1 User Account
- to create new user
- to edit user information of already registered users
- to deactivate accounts.
Enter exact user name and password
[first time: “Admin”, no password]
Change existing user
accounts
Enter a user name (maximum 32 characters). Spaces are the only
characters that cannot be used.
User Name
(required item)
Enter additional information about the account
(this field is optional max.128 characters)
![](/html/2b/2bbb/2bbb71fb181e91bf909843bc9a4b31ade8d800283781c01dc46d673260292a86/bg7.png)
TOCV-CP_IMshort_Control-ver-2_Rev07F Page 7 of 22
(Software version ≥ 2.00) effective date: September 2007
Enter the password for the new account. The limits for password
length and complexity can be changed. Please refer to the
Administration Menu
Confirm Password
(required item)
Enter the password again.
Company, Department,
Position, Tel, email
Enter additional information of user if required
User Level
Administrator
Main User
User
Guest
Detailed Access Rights
Select a radio button to establish the user level
[Each user level has a set of access rights that are selected by
default. Adaptation is possible, see detailed access rights.]
Add or remove access rights for main user, user and guests
Lists the functions that a user can access. Each of the four user
levels has a default list of access rights, displayed in this field.
The administrator can use this list to add or remove access rights for
main user, user and guests. Please refer to the Administration Menu
Click on the OK button to create a new account
2.3.2 Change Password
- to change the password of user ID
2.4 Others
2.4.1 LIMS Settings
- The LIMS-related settings are used to establish a relationship between external
applications and TOC-Control V software. These applications run in the background
before an d after measurement
- Please refer to the Administration Manual
2.4.2 Database Manager
- The Database Manager enables export of the database file in .mdb format (Microsoft
Access)
- Please refer to the Administration Manual
2.4.3. Data Profile Viewer
- The data profile can be exported from TOC-Control V software and displayed. Each
row of the TOC-Control V sample table is output as an individual data profile