Sharp IG-DC2A Operation Manual

ENGLISH
IG-DC2A
Plasmacluster is a registered trademark or a trademark of Sharp Corporation.
Plasmacluster 乃 Sharp 株式會社的註冊商標或 商標。
Plasmacluster Ion Generator OPERATION MANUAL
Read and keep this manual carefully.
*1 本技術標示的數字是指本商品向空中吹出的每 1cm
3
中所 含離子的數目。該數值是在房間中央位置 ( 離地 0.5米), 而機器擺放在類似杯座的地方,運行高速風速時所量度的。
*1 The number on this technical mark indicates the number
of ion count per 1cm
3
blown out to the air, which is measured near the center of space (0.5m height from floor) when the air volume is "HIGH" by placing this product at the place supposing a cup holder beside the driver's seat.
SHARP CORPORATION
Osaka, Japan
Printed in Thailand
TINS-A569KKRZ 12E-
1
請仔細閱讀並妥善保存這本手冊。
HD PCI
抗菌機
使用說明書
中文
IG-DC2A.EN.indd1IG-DC2A.EN.indd1 2012/04/1110:54:032012/04/1110:54:03
IG-DC2A.EN.indd2IG-DC2A.EN.indd2 2012/04/1110:54:042012/04/1110:54:04
ENGLISH
ENGLISH
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please read this manual carefully before using Plasmacluster Ion Generator. After reading, keep the manual in a convenient location for future reference.
E-1
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
...............
E-2
• WARNING
...............................................................
E-2
• CAUTIONS CONCERNING OPERATION
......................
E-3
PARTS NAME
........................................................
E-4
• MAIN UNIT • CONTROL PANEL/DISPLAY
..........................
E-4
• BACK/ACCESSORIES
........................................................
E-4
INSTALLATION GUIDANCE
........................................
E-5
OPERATION
......................................................................
E-7
CLEANING AND MAINTENANCE
.............................
E-8
• FILTER
.................................................................................
E-8
• MAIN UNIT
...........................................................................
E-8
• PLASMACLUSTER ION GENERATING UNIT
....................
E-9
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
..
E-10
REPLACING THE FUSE
..............................................
E-12
SPECIFICATIONS
..........................................................
E-12
TROUBLESHOOTING
..................................................
E-13
• While IG-DC2A can remove suspended viruses and other contaminants, it cannot create a completely sterile environment. SHARP does not guarantee its ability to prevent microbial infection.
• To enable stable emission of high-density Plasmacluster ions, the Plasmacluster Ion Generating Unit mounted in IG-DC2A will need to be replaced periodically*
.
The unit is designed for ordinary passenger cars with DC 12V batteries. It cannot be used in vehicles with DC 24V batteries (buses, trucks, etc.).
* Replacement is required approximately every 6 years (17,500 hours) when
operated 8 hours a day. IG-DC2A will stop operating after about 6 years and 6 months (19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced.
IG-DC2A.EN.indd3IG-DC2A.EN.indd3 2012/04/1110:54:042012/04/1110:54:04
E-2
IMPORTANT SAFETY INSTRUCTIONS
Please read instructions carefully before using this unit as below.
WARNING - To reduce the risk of electric shock, fi re or injury :
When using electrical appliances, basic safety precautions should be followed, including the following:
• Do not operate switches while driving. (Doing so could lead to accidents.)
• Do not install the unit in places where it could hamper visibility to the front or driving operations, or in places where it could be dangerous to passengers. (Doing so could lead to accidents or injury.)
• Do not put in places exposed to direct sunlight. (Do so could cause warping or malfunction.)
• This unit is designed exclusively for use in vehicles with 12V batteries. Do not use it in other vehicles. Do not use the unit in large trucks, buses or other vehicles with 24V batteries. (Doing so could lead to fi re or electric shock.)
• Do not damage or modify the cord. Also, do not use the cord if it is damaged. (The damaged section could cause short-circuiting and the cord could melt, leading to fi re.)
If the cord is damaged, contact your store of purchase or SHARP authorized service
center.
• Do not pull on the cord when unplugging the cigar plug or the unit connection plug. (Doing so could damage the cord, leading to fi re or electric shock.)
• Do not plug in or unplug the cigar plug or the unit connection plug with wet hands. (Doing so could cause electric shock.)
• When transporting, be careful not to drop the unit or subject it to shocks.
(Doing so could cause injury or damage.) If the unit should drop or get damaged, contact your store of purchase or SHARP
authorized service center.
Continued usage as such could lead to fi re or electric shock.
• Do not modify the unit. Also, no one other than an authorized repairman should take apart or repair the unit. (Doing so could lead to fi re, electric shock or injury.)
Contact your store of purchase or SHARP authorized service center for repairs.
• Do not spill beverages or drop cigarette ashes, metal objects, easily burnable objects, etc., into the unit through the air outlet or air intake.
Be particularly careful if there are small children in your family. If water or foreign
substances should get inside the unit, unplug the cigar plug from the cigar lighter socket.
(Continued usage as such could lead to fi re or electric shock.) Contact your store of purchase or SHARP authorized service center.
• Do not wipe the unit with oils, alcohol, benzene or thinner, or spray hairspray or insecticides on the unit.
If such substances should get on the unit, wipe them off immediately. (Such substances could lead to cracking or electric shock or could catch fi re.)
• Do not place the product at the place where is exposed to oil smoke or moisture such as kitchen counter or humidifying device. (Doing so could lead to electric shock.)
• Do not place the product near heating equipment such as outlet of hot-air type heater. (Do so could cause warping or malfunction.)
• Use the car adapter designed exclusively for this unit, and insert the cigar plug securely all the way in until it stops.
(If the cigar plug is not inserted securely until it stops, it could heat up, deforming the
cigar lighter socket, and this could lead to fi re.)
IG-DC2A.EN.indd4IG-DC2A.EN.indd4 2012/04/1110:54:042012/04/1110:54:04
ENGLISH
E-3
CAUTIONS CONCERNING OPERATION:
• Do not touch the metal parts of the car adapter’s cigar plug (or of the cigar lighter socket).
(The metal parts of the cigar plug could be hot directly after the car is stopped, and could
cause burns if touched.)
• Do not use the unit in commercially available cup holders, on shaky or non-level surfaces or in other unstable places. (The unit could fall, resulting in injury or damage.)
• Move the unit out of the car when using room fumigating type insecticides or deodorizers.
If not, the chemicals could get inside the unit and later be ejected from the air outlet,
possibly harming your health.
• If the unit risks falling out of the cup holder (when driving on rough roads, over bumps, etc.), either slow down or remove the unit from the cup holder beforehand.
(Failure to do so could cause injury or damage to the unit.)
• Do not use items of silicone-containing products* near the unit.
The fl uororesin or silicone could get stuck inside the unit, preventing it from producing
plasmacluster ions.
If this happens, remove the dust from the electrode section of the Plasmacluster Ion
Generating Unit. (See E-9)
* Hair care products (split end coatings, hair mousses, hair treatments, etc.), cosmetics,
antiperspirants, antistatic agents, waterproofi ng sprays, polishes, glass cleaners, chemical- impregnated clothes, wax, etc.
• If the fuse should blow, be sure to replace it with a 5A glass tube fuse (commercially available). Never use a piece of wire, etc., in place of the fuse.
(Using anything other than the specifi ed type of fuse could cause heating, leading to fi re.)
• Be sure to unplug the cigar plug from the cigar lighter socket when cleaning. (Failure to do so could cause electric shock or injury.)
• Be sure to unplug the cigar plug from the cigar lighter socket when not using the unit for long periods of time. (Failure to do so could lead to electric shock or fi re caused by short- circuiting.)
• If the cigar lighter socket is integrated into the ashtray, be sure that cigarettes are completely put out before using.
When leaving the vehicle, unplug the cigar plug and close the ashtray’s lid. (Failure to do so could lead to fi re caused by the smoldering cigarettes.)
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
IG-DC2A.EN.indd5IG-DC2A.EN.indd5 2012/04/1110:54:042012/04/1110:54:04
IG-DC2
E-4
PARTS NAME
Air Outlet
Main Unit
MAIN UNIT • CONTROL PANEL/DISPLAY
BACK
ACCESSORIES
Turbo Button
Turbo Light
(purple)
Operation Light
Ion sign
(blue)
Unit Replacing Light
(red)
(See E-7)
(See E-7)
(See E-10)
Car Adapter
Unit Connection Plug
Cigar Plug
(With 5A glass tube fuse)
Connect to the cigar lighter socket in the vehicle.
Cord
* If the Plasmacluster Ion Generating Unit replacement time comes,
Unit Replacing Light lights up.
*
(Inside of main unit)
Plasmacluster Ion Generating Unit
Power Input Terminal
Filter Cover
Air Intake (Filter)
Do not remove the cushioning material from the back of the cover.
Operation Button
IG-DC2A.EN.indd6IG-DC2A.EN.indd6 2012/04/1110:54:042012/04/1110:54:04
ENGLISH
E-5
Connecting the car adapter and installing the unit
INSTALLATION GUIDANCE
Remove the filter cover.
1
1
2
Filter cover
Remove
Insert the car adapter's unit connection plug securely into the unit power input terminal.
2
Route the cord in one of the ways shown in the diagram, according to the place of installation, then attach the fi lter cover.
3
Cord
Use one of these routes.
Hook
Insert it from lower side
Attach
Upper
Bottom
• Be careful the cord does not get caught in the fi lter cover.
Insert the cigar plug into the cigar lighter socket.
4
• Be sure to remove any dirt from the
cigar lighter socket. Failure to do so could cause faulty contact or fi re.
Cigar plug
Cigar lighter socket
Lock part
IG-DC2A.EN.indd7IG-DC2A.EN.indd7 2012/04/1110:54:052012/04/1110:54:05
E-6
Set the unit in the cup holder with its air outlets facing in the desired direction.
5
Cautions on wiring the car adapter
• Do not let the cord touch or get caught in the seat rails, shift lever or other moving parts.
• Wire in such a way that the cord does not get in the way of the driver.
• Consider the movement of the seats (forward/backward, swiveling or reclining) when wiring.
• Do not bend the cord extremely or compress it.
• Be sure to place on a stable location. (Do not put in a commercially available cup holder or other unstable place.)
• Do not obstruct the air inlet or outlet.
• Keep the unit away from the vehicle’s in-glass antenna. Failure to do so could cause noise in the radio.
• If there should be noise in a TV or radio located in the same car, or if an atomic clock in the car should not display the time properly, move the unit away from the TV, radio, atomic clock, etc.
If the unit is installed directly in front of the car climate control’s outlets, the unit could get hot when the climate control is operating in the heating mode.
• The unit could get scratched by the vibrations of the vehicle, etc.
Cautions on installation
• Separate the main unit from electronic key of vehicle by 30cm or more. Otherwise, it may interferes with electronic wave of main unit and the electronic key may not be recognized.
Air outlet
Separate the main unit from electronic key of vehicle by 30cm or more.
IG-DC2A.EN.indd8IG-DC2A.EN.indd8 2012/04/1110:54:062012/04/1110:54:06
ENGLISH
E-7
OPERATION
LOW
HIGH
'OFF'
If you want to operate the product in silence
Release high-density Plasmacluster ions quietly.
If you want to operate the product at strong fl ow rate
Release high-density Plasmacluster ions at high fan speed.
When you want to remove the odor quickly
Approximately two fold Plasmacluster ion is of "HIGH" fan speed is discharged with stronger air volume.
• After smoking
• After eating in a vehicle
• When you are conscious about odor of air conditioner
Power 'OFF'.
If the vehicle's engine is turned off and the vehicle is stopped while the unit is operating, the unit resumes operating in the same mode when the vehicle's engine is started back up.
•
For preventing you from forgetting to turn OFF the product, it automatically stops after 8 hours from the operation is started, however, if the main unit is operated even if the key of the vehicle is pulled out or the engine switch is turned OFF, pull out the cigar plug for preventing the dead battery.
While the operation is stopped
• The “TURBO” operation is enabled by just pressing the Turbo Button. When the “TURBO” operation is executed by pressing the button, the operation is stopped by pressing the Turbo Button or Operation Button.
Press
Engine interlocking function
TURBO
In operation
• The operation is switched to “TURBO” operation by pressing the Turbo Button.
If you press the Turbo Button or Operation Button during the “TURBO” operation, the mode returns to the operation mode immediately before the “TURBO” operation.
To select the preferred mode
IG-DC2A.EN.indd9IG-DC2A.EN.indd9 2012/04/1817:44:312012/04/1817:44:31
E-8
CLEANING AND MAINTENANCE
MAIN UNIT
Every month or more often if necessary
<For Stubborn Dirt>
Use water and a mild detergent. And then, wipe with a wet cloth. Make sure to dry out the main unit. Every
FILTER
Frequently as necessary
Wipe with a dry soft cloth.
t
The fi lter must be cleaned regularly in order to maintain the ion density. Filter soiling depends on the usage environment, so clean the filter frequently as necessary. By frequently cleaning, Plasmacluster ion can be released effi ciently.
Gently remove dust from the filter of back side by using a vacuum cleaner.
<For Stubborn Dirt>
• Remove and rinse in water. (Use a soft sponge if the dirt does not come off easily.)
Be careful the cushioning material does not come off.
• Do not press the vacuum cleaner strongly against the filter, or the filter could be damaged.
• If using synthetic kitchen detergent, rinse well to remove all traces of the detergent. Also, be sure to dry the fi lter in the shade.
• Dry the product in a shaded area so that water drop does not remain in gap between lter cover and fi lter.
Filter
Rinse Wipe with a dry cloth. Reattach
(Dry in the shade.)
IG-DC2A.EN.indd10IG-DC2A.EN.indd10 2012/04/1110:54:062012/04/1110:54:06
ENGLISH
E-9
Plasmacluster Ion Generating Unit (electrode section)
Every 6 months or more often if necessary
If such a message is displayed, carry out the maintenance of the Plasmacluster Ion Generating Unit (electrode section).
Dust, fl uorine resin, or silicone may be attached and the Plasmacluster ion may not be generated depending on the use environment*. Carry out the maintenance periodically.
Remove the Plasmacluster Ion Generating Unit from the main unit referencing “Plasmacluster Ion Generating Unit Replacement”. (See E-11) Remove dust or foreign object attached to the electrode (needle) of the Plasmacluster Ion Generating Unit or periphery with a cotton swab.
The Operation Lights “LOW” and “HIGH” (blue) fl ash at the same time and the operation is stopped.
Electrode section
Do not touch the connection terminal
[Before cleaning]
[After cleaning]
Flashing (blue)
Cotton swab
• Do not touch the electrode section. (Doing so could lead to injury.)
• Do not transform the electrode section. (Doing so could lead to damage.)
• Do not touch the connection terminals. (Doing so could lead to damage.)
• Please damp the tip of a cotton swab with little water, if the dirt does not come off easily.
* Places where hair care products (split end coatings, hair mousses, hair treatments,
etc.), cosmetics, antiperspirants, antistatic agents, waterproofi ng sprays, polishes, glass cleaners, chemicalimpregnated clothes, wax, etc. are used or smoking environment.
Electrode (needle)
Circumference of base part
IG-DC2A.EN.indd11IG-DC2A.EN.indd11 2012/04/1110:54:072012/04/1110:54:07
E-10
PLASMACLUSTER ION GENERATING UNIT REPLACEMEN
T
If the total operating time passes approximately 17,500 hours (approx. 6 years if the product is operated 8 hours a day), Unit Replacing Light fl ashes to notify you of the replacement time of the unit.
* The unit replacement period is same even if the product is operated in any
operation mode.
Elapsed Time
Replacement of Plasmacluster Ion Generating Unit
Display
Message
* When turned back on after the unit is replaced, the
Unit Replacing Light
is off.
(See E-11)
Plasmacluster Ion Generating Unit
Model Number:
IZ-C75CE
Beginning to use
Approx. 17,500 hours (approx. 6 years when operated 8 hours a day)
Approx. 19,000 hours (approx. 6 years and 6 months when operated 8 hours a day)
<For Disposal>
Please dispose the used Plasmacluster Ion Generating Unit according to any local laws and regulations.
-materials-
• Case : Polystyrene
Unit : Polystyrene Terephthalate, Electric
"UNIT" is fl ashing (red)
Stop working
parts
Replace the Plasmacluster Ion Generating Unit
"UNIT" is fl ashing rapidly (red)
IG-DC2A.EN.indd12IG-DC2A.EN.indd12 2012/04/1110:54:072012/04/1110:54:07
ENGLISH
E-11
How to replace Plasmacluster Ion Generating Unit
Remove the fi lter cover and pull out the plug for connecting the main unit
1
1
2
Filter cover
Remove
Filter cover
Attach
With a coin or other item
Plasmacluster Ion Generating Unit
Unscrew the screw that fi xes the Plasmacluster Ion Generating Unit and remove it
2
Attach a new Plasmacluster Ion Generating Unit and x it with a screw
Connect the plug for connecting the main unit and attach the lter cover
Insert the cigar plug in the cigar lighter socket and check the Unit Replacing Light is turned OFF
3
4
5
• After the replacement, you may feel the sound “Zi, Zi ...”(sound generated by
Plasmacluster ion) become larger, however, you feel it because the Plasmacluster Ion Generating Unit is replaced with a new one. It is not a failure.
IG-DC2A.EN.indd13IG-DC2A.EN.indd13 2012/04/1110:54:082012/04/1110:54:08
E-12
REPLACING THE FUSE
HOW TO REPLACE
SPECIFICATIONS
*1 It is the index of capacity that approximately 25,000 ions blown out to the air can
be measured at the point near the center of the space (0.5m height from floor) when the air volume is "HIGH" by placing this product at the place supposing a cup holder beside the driver's seat.
*2
Space corresponding to a cabin measuring 1.5 (width) x 2.4 (depth) x 1.0 (height) meters
* Some specifi cations may be changed for improvement purposes.
Model
Rated voltage
Applicable interior volume
*
1
Operation mode
Power consumption
Ion density
Operating noise level
Outer dimensions
Weight
DC12V
Approx.
3.6
m
3
*
2
1.1W 1.8W
23dB
Approx. 270g (Not including car adapter)
IG-DC2A
HIGHLOW
Turn the tip of the cigar plug and remove it.
1
5A glass tube fuse
New fuse
Insert the new fuse, then reassemble as before.
2
• Be sure to replace with a 5A glass tube fuse (commercially available).
29dB
Cylindrical, 76 mm upper section diameter / 65 mm lower section diameter x 150 mm height (Not including car adapter)
ACCESSORIES
Car Adapter / Operation manual
2.7W
TURBO
33dB
Approx. 7,000 ions/cm
3
Approx. 25,000 ions/cm3Approx. 50,000 ions/cm
3
IG-DC2A.EN.indd14IG-DC2A.EN.indd14 2012/04/1110:54:092012/04/1110:54:09
Loading...
+ 32 hidden pages