HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
...
...
E-2
E-2
E-2
E-2
E-3
E-3
E-3
E-4
E-4
E-5
E-5
E-5
E-6
E-7
ENGLISH
SPECIFICATIONS
TROUBLESHOOTING
• While IG-BL20E can inactivate suspended viruses and other contaminants, it cannot create a completely sterile environment. SHARP
does not guarantee its ability to prevent microbial infection.
• To enable stable emission of high-density Plasmacluster ions, the
Plasmacluster Ion Generating Unit mounted in IG-BL20E will need to
be replaced periodically*.
*Replacement is required approximately every 2 years (17,500 hours) when oper-
ated 24 hours a day.
hours) if the Plasmacluster Ion Generating Unit is not replaced.
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please
read this manual carefully before using Plasmacluster Ion Generator.
After reading, keep the manual in a convenient location for future reference.
The information provided in this manual is subject to change without notice.
E-1
Page 4
E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following
:
WARNING - To reduce the risk of electrical shock, re, or injury :
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet is loosened.
• Periodically remove dust from the plug.
• DO NOT insert ngers or foreign objects into the air intake or air outlet.
• Always hold the plug and never pull on the cord when removing the power plug.
Electrical shock and/or re from a short circuit may result.
• DO NOT remove the plug when your hands are wet.
• DO NOT use the unit near gas appliances or replaces.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp
Authorized Service Center or similarly qualied person in order to avoid a hazard.
• Be cautious when cleaning the unit.
Strong corrosive cleansers may damage the exterior.
• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks
from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as a bathroom.
• Only a Sharp Authorized Service Center should service this Plasmacluster Ion Generator.
Contact the nearest Service Center for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
CAUTIONS CONCERNING OPERATION:
• Do not ride the main unit and do not sit on or lean it, it may cause injury or malfunction.
• DO NOT block the air intake and/or air outlet.
• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come into contact
with steam.
• Always operate the main unit in an upright position.
• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or cracked.
• Keep the main unit away from water.
INSTALLATION GUIDELINES:
• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference when using the unit.
• Avoid using in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate room temperature is between 0-35ºC.
• Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may crack as a
result.
NOTE - Radio or TV Interference:
If this Plasmacluster Ion Generator may cause interference to radio or television reception,
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Page 5
ENGLISH
PARTS NAME
FRONT
DISPLAY
Lights Control Button
Filter Reset Button
(3sec)
Unit Replacing Light
Filter Clean Light
Front Louver
Air Outlet (Front)
Operation Button
Fan Speed Indicator
LOW
MED
HIGH
ENGLISH
Caution Label
BACK
Back Louver
Air Outlet (Back)
Cluster Door
Power Cord
Plug
(Shape of plug depends
on country)
Handle
Plasmacluster Ion
Generating Unit
Filter (Air Intake)
E-3
Page 6
E-4
INSTALLATION POSITION
bright
dark
Place the main unit on a smooth, stable surface in a room, and insert the plug into
an outlet.
Installation Guidance
Leave at least 10cm of clearance behind the unit.
UPSIDE More than 60cm
DO NOT USE the below items
near the unit
.
silicone-containing products*
SIDE Mo re t han
60cm
B A C K S I DE M o r e
than 10cm
SIDE Mo r e t h a n
60cm
SPRAY
*Hair care products, cosmetic products,
wat er pr oof s pra ys, p oli sh glass
cleaner, wipe and wax.
WAX
PESTICIDES
OPERATION
Press the operation button to directly turn on the power and
select the preferred mode.
Operation Button
Lights Control Button
LIGHTS CONTROL
If you feel indicator lights are too bright, press
the LIGHTS CONTROL Button. The brightness
is changed.
LOW
MED
HIGH
'OFF'
Release high-density
Plasmacluster ions quietly.
Release high-density
Plasmacluster ions at
medium fan speed.
Release high-density
Plasmacluster ions at high
fan speed.
Power 'OFF'.
Page 7
ENGLISH
CLEANING AND MAINTENANCE
Lighting (orange)
WARNING:
When cleaning the unit, be sure to rst unplug the power cord,
and never handle the plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
MAIN UNIT
Every month or more often if necessary
Wipe with a dry soft cloth.
<For Stubborn Dirt>
Use water and a mild detergent.
And then, wipe with a wet cloth.
Make sure to dry out the main unit.
FILTER
Every 1 week or more often if necessary
<FILTER CLEAN LIGHT>
FILTER CLEAN LIGHT lights up after approx.
1 month (approx, 720 hours), when operated
24 hours a day.
Detach the lter and remove dust with using a vacuum cleaner.
Press FILTER RESET Button, it sounds "♪" and the
light is turned off.
ENGLISH
Detach
Tab
Filter
Push the both tabs toward arrow.Set one side of the lter tab rst.
<FILTER RESET Button>
After cleaning, press FILTER RESET Button for 3
seconds. The FILTER CLEAN LIGHT will go off.
Even if the FILTER CLEAN LIGHT is off, press the
FILTER RESET Button for 3 seconds after cleaning.
CleanAttach
Push and set the another side of lter tab
toward arrow.
E-5
Page 8
E-6
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
In order to release Plasmacluster Ion stably, periodical replacement of Plasmacluster Ion Generating Unit is necessary.
The Unit Replacing Light lights up as a reminder for replacement.
Elapsed TimeDisplayMessage
Beginning to use.
Approx. 1 year and
10 months. (Approx.
16,000 hours)
Approx. 2 years. (Ap-
prox. 17,500 hours)
Lighting(green)
Lighting(orange)
Flashing(red)
Operate normally.
The Plasmacluster
Ion Generating Unit
is soon be replaced.
Suggest replacing
Plasmacluster Ion
Generating Unit.
Approx. 2 years and
2 months. (Approx.
19,000 hours)
* Usage environment affects the lifetime of the Plasmacluster Ion Generator.
The Plasmacluster Ion Generator may stop operating before estimated lifetime.
In this case, press Operation button again and restart.
If this does not help, replace with a new Plasmacluster Ion Generating Unit.
Flashing faster(red)
•Unit stops operation.
•Replace the
Plasmacluster Ion
Generating Unit.
Plasmacluster Ion Generating Unit for Replacement
<For Disposal>
Please dispose the used Plasmacluster Ion Generating
Unit according to any local laws and regulations.
-materials-
• Case : Acrylonitrile Butadiene styrene (ABS)
• Unit : Polybtutylene Terephthalate (PBT), Electric parts.
Plasmacluster Ion Generating Unit
Model
IZ-CBL20E
Page 9
ENGLISH
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
1
2
3
*When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the
main unit, unplug the power cord, and never handle the plug with wet hands.
Remove the 2 screws by the one like the coin, and open the Cluster Door.
2 screws
Remove the Plasmacluster Ion Generating Unit by the handle.
ENGLISH
Plasmacluster Ion
Generating Unit
Replace the new Plasmacluster Ion Generating Unit.
Fix it into the main unit rmly.
*Never touch the connector terminal of Plasmacluster Ion Generating Unit.
*After replacing the Plasmacluster Ion Generating Unit, press the Operation
Button.
Fill the replacement date on the label of side of the main unit.
E-7
Page 10
E-8
SPECIFICATIONS
ModelIG-BL20E
Power supply220-240V,50/60 Hz
Fan Speed AdjustmentHIGHMEDLOW
Power consumption(W)138.55.5
Airow volume(m3/hour)270210156
Applicable oor area(m2)
Ion density(ions/cm3)
Cord Length(m)1.8
Outer dimensions(mm)392(W)x182(D)x500(H)
Weight(kg)5.8
*1 The applicable floor area for which an emitted airborne ion density of about 25,000 ions/cm3 can be
measured at a point near the center of the room (at a height of about 1.2m from the floor), during
operation at the HIGH mode when the main unit is placed near a wall.
*2 Ion count per cm3 blown into air at around the center of the room ( at a height of approx. 1.2m from the
oor) during operation at each airstream setting when the main unit is placed near the wall.
• The number of ions will vary according to the room conditions and operation mode.
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this
product consumes about 0.8W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.
*1
*2
25,00012,0007,000
20
TROUBLESHOOTING
Before calling for service, please review the TROUBLESHOOTING chart below.
The problem may not be a unit malfunctions.
ProblemWHAT TO DO
•It’s time to replace Plasmacluster Ion Generating
Flashing
(red)
Flashing
(red)
Lighting
(orange)
Flashing
(blue)
Flashing
(blue)
Unit.
Replace with a new Plasmacluster Ion Generat-
ing Unit. (See page E-7)
•
Plasmacluster Ions are not released. Dust may block the lter,
clean the lter.(See page E-5)
If the lights are still ashing after cleaning lter, unplug and
contact the store you purchased or Sharp service center.
•Filter is getting dirty. Clean the lter.
After cleaning the filter, press FILTER RESET
Button for 3 seconds. (See page E-5)
•Conrm the Plasmacluster Ion Generating Unit is
set correct position, and press the Operation But-
ton to restart. (See page E-7)
Flashing
(
red & green
Flashing
(blue)
•Failure
Flashing
(blue)
)
Flashing
(blue)
Unplug the power cord and contact the store you
purchased or Sharp service center.
Page 11