PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
SPECIFICATIONS
TROUBLESHOOTING
• While IG-A20E and IG-A40E can inactivate suspended viruses and
other contaminants, it cannot create a completely sterile environment. SHARP does not guarantee its ability to prevent microbial infection.
• To enable stable emission of high-density Plasmacluster ions, the
Plasmacluster Ion Generating Unit mounted in IG-A20E and IG-A40E
have to be replaced periodically*.
* Replacement is required approximately every 2 years (17,500 hours) when operated
24 hours a day. IG-A20E and IG-A40E will stop operating after about 26 months
(19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced.
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please
read this manual carefully before using Plasmacluster Ion Generator.
After reading, keep the manual in a convenient location for future reference.
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electric shock, fi re, or injury :
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet is
loosened.
• Periodically remove dust from the plug.
• DO NOT insert fi ngers or foreign objects into the air intake or air outlet.
• Always hold the plug and never pull on the cord when removing the power plug.
Electric shock and/or fi re from a short circuit may result.
• DO NOT remove the plug when your hands are wet.
• DO NOT use the unit near gas appliances or fi replaces.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp
authorized Service Center or qualifi ed person in order to avoid a hazard.
• Be cautious when cleaning the unit.
Strong corrosive cleansers may damage the exterior.
• DO NOT use it in the areas where the unit may get wet.
• DO NOT use spray products near the unit.
• DO NOT use in the rooms, containing oil component, incense, cigarettes’ sparks, and chemical
fumes.
• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet,
such as bathroom.
• DO NOT use these silicone-containing products in the room where the unit is installed.
• Only a Sharp authorized Service Center should service this Plasmacluster Ion Generator.
Contact the nearest Service Center for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• Do not ride on the main unit and do not sit on or lean it, it may cause injury or malfunction.
CAUTIONS CONCERNING OPERATION:
• DO NOT block the air intake and/or air outlet.
• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Always operate the main unit in an upright position. Always unplug the unit before cleaning.
• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or
cracked.
• Keep the main unit away from water.
INSTALLATION GUIDELINES:
• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to
avoid electrical interference when using the unit.
• Avoid using in locations where the unit is exposed to condensation or drastic temperature changes.
Appropriate room temperature is between 0-35ºC.
• Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may
crack as a result.
NOTE - Radio or TV Interference:
If this Plasmacluster Ion Generator may cause interference to radio or television reception,
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the unit and radio/TV receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
• Consult the dealer or an experienced radio/TV technician for help.
E-2
PARTS NAME
Louvers
(Air outlet of Plasmacluster Ion)
High density Plasmacluster Ion is discharged
forward. (Do not put anything in front of the unit.)
Plasmacluster Ion Generating Unit
(Inside)
Please open the cover only when replacing the
Plasmacluster Ion Generating Unit.
(See page E-9)
Power cord
Plug
CONTROL PANEL
Filter (Air Intake)
* Clean the fi lter periodically.
* Do not block the air intake or do not put
anything into the unit.
FILTER CLEAN Light
UNIT REPLACEMENT
HIGH
MED
Fan Speed
Indicator
(blue)
(yellow)
Light
(red)
LOW
OPERATION Button
UNIT RESET Button
Press this button for 3 seconds after replacing
the Plasmacluster Ion Gennerating Unit.
Don't press it for any other purposes.
ENGLISH
DEUTSCH
FRANÇAIS
FILTER RESET Button
After cleaning the fi lter, plug the power cord and
press the FILTER RESET button for 3 seconds.
AUTO RESTART Switch
FIX THE OPERATION COVER BY SCREW
If necessary, operation cover can be fi xed by accessary screw.
washer
screw
E-3
rubber cover
NEDERLANDS
РУССКИЙ
INSTALLATION POSITION
Place the main unit on a smooth, stable surface in a room, and insert the plug into an outlet.
Please note the required clearance.
UPSIDE more than 60cm
BACKSIDE more than 6cm
SIDE more than 60cm
SIDE more than 60cm
Installation Guidance
• To secure the performance, do not put anything in front of the unit.
• To secure the performance, do not block the air intake or do not put anything into the unit.
• If necessary, unit is fi xed to the wall using accessary parts or fi xed by anchor bolt see page E-5.
DO NOT USE the below items near the unit.
silicone-containing products*
SPRAY
WAX
PESTICIDES
ACCESSORIES
• Operation manual
• Tip-resistant kit
• Screw kit
Tip-resistant kit
(In case of fi xing the main unit to the wall)
* Hair care products, cosmetic
products, water proof sprays,
polish glass cleaner, wipe and
wax.
Screw kit for operation cover
mounting parts for wall
(2pcs)
Anchor bolt, nut, and washer for fi xing to the fl oor and screw for the wall for fi xing to the wall are not included
as accessory parts.
screw for the
main unit (2pcs)
screw (1pc)
E-4
rubber cover (1pc)
washer (1pc)
HOW TO INSTALL THE UNIT
Unscrew the painted screws
(2 pcs on each side ).
1
Lift up the Side Panel and remove
2
it outward.
Side Panel
In case of fi xing the main unit to the fl oor by anchor bolts.
3
Measure the position of the anchor
bolts and fi x them to the fl oor.
Put the main unit on the anchor
bolts and tighten surely with washer
and nut.
In case of fixing the main unit to the
wall with the mounting parts.
Fix the mounting parts to the main unit
by screws. (Right and left side)
The mounting parts and screws are
accessory parts. (Each 2 pcs)
wall
552mm(IG-A20E)
898mm(IG-A40E)
right side of rear
28mm
mounting part(right)mounting part(left)
* The height of the anchor
bolt is 25mm or less.
Size of anchor bolt
*
over
180mm
diameter is 8mm or less.
anchor bolts
nut
washer
wall side
anchor bolt
left side of rear
screwscrew
28mm
ENGLISH
DEUTSCH
FRANÇAIS
NEDERLANDS
Screws are to be surely tightened.
* Depending on the material of the wall, it may
not be able to tighten.
Attach the Side Panel and screw
the painted screws on both sides.
4
РУССКИЙ
E-5
OPERATION
* This operation manual is based on IG-A40E.
The operation is same as IG-A20E.
Open the cover of Control Panel.
In case that the cover is fixed by a screw, take out the
rubber cover and a screw, and open the cover of control
panel.
Fix the cover of Control Panel.
As necessary, screw down the cover with the provided
screw and the washer and fi t in the rubber cover.
(Please see Page E-3)
Press the Operation Button to select the preferred mode.
Control
panel
OPERATION BUTTON
AUTO RESTART
LOW
MED
HIGH
Power 'OFF'
Release high-density
Plasmacluster ions quietly.
Release high-density
Plasmacluster ions at medium fan
speed.
Increase the volume of highdensity Plasmacluster ions to
increase the purifi ying capacity.
AUTO RESTART
Switch
If the AUTO RESTART switch is set to "ON"
and the unit is accidently unplugged, the
circuit breaker trips of there is a power failure,
the unit will automatically start operation at the
previous setting power is restored.
E-6
CLEANING AND MAINTENANCE
WARNING:
When cleaning the unit, be sure to fi rst unplug the power cord, and never handle the
plug with wet hands.
Electric shock and/or bodily injury may occur as a result.
Main Unit
Every month or more often if necessary.
Wipe with a dry soft cloth.
<For Stubborn Dirt>
Use water and a mild detergent.
And then, wipe with a wet cloth.
Make sure to dry out .
FILTER
Every 2 weeks or more often if necessary.
FILTER CLEAN Light will be lit after approx. 1 month (approx. 720 hours), when operated 24 hours a
day.
Pull out the fi lter from bottom of the main unit and remove dust by using a vacuum cleaner or similar
tools.
ENGLISH
DEUTSCH
FRANÇAIS
NEDERLANDS
IG-A20E Filter (1pc)
IG-A40E Filter (2pcs)
* A filter is not disposable item, often
clean the fi lter.
Filter
• When the fi lter is very dirty, please wash with water
or using mild kitchen detergent.
CAUTION
• Do not rub with a hard sponge and do not bend it
when washing.
• Avoid drying fi lters outdoors under sunlight or using
near a stove.
FILTER RESET Button
After cleaning, insert the plug and press RESET
Button for 3 seconds.
E-7
РУССКИЙ
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
In order to release Plasmacluster Ion stably, periodical replacement of Plasmacluster
Ion Generating Unit is necessary. The Unit Replacement Light will be ON as a reminder
for replacement.
Elapsed Time
Beginning to use.
Approx. 2 years.
(approx. 17,500hours)
Approx. 2 years and
2 months.
(approx.19,000hours)
Display
fl ashing (red)
fl ashing faster (red)
Lighting(blue)
Lighting(blue)
Message
Operate normally
Suggest replacing
Plasmacluster Ion
Generating Unit.
• Unit has stopped
working.
• Replace the
Plasmacluster Ion
Generating Unit.
Plasmacluster Ions
are not released.
* Usage environment affects the lifetime of the Plasmacluster Ion Generator.
The Plasmacluster Ion Generator may stop working before estimated lifetime.
In this case, press Operation Button again and restart.
If this does not help, replace with a new Plasmacluster Ion Generating Unit.
fl ashing (red)
fl ashing (blue)
Error*
Plasmacluster Ion Generating Unit for Replacement
Plasmacluster Ion Generating Unit
Model
Number
IZ-CA40E (for IG-A40E)
IZ-CA20E (for IG-A20E)
<For Disposal>
Please dispose the used Plasmacluster Ion
Generating Unit according to any local laws and
regulations.
-materials-
• Case: Acrylonitrile Butadiene Styrene (ABS)
• Unit: Polybuthylene Terephthalate (PBT), Electric
parts.
E-8
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
* When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the main
unit, unplug the power cord, and never handle the plug with wet hands.
Remove the rubber cover and unscrew
1
the center screw of the Ion Generator
Cover.
ENGLISH
2
rubber cover
DEUTSCH
FRANÇAIS
Push the both corner of Ion Generator
Cover and open it.
(IG-A40E only)
NEDERLANDS
РУССКИЙ
Ion Generator Cover
E-9
(see next page)
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
Pull up the lever in the direction of
3
Pull up the lever
the arrow to unlock it.
Pull the lever in the direction
of the arrow and take out the
Plasmacluster Ion Generating Unit.
Unit
IG-A20E
Remove the connector cover.
(IG-A40E only : 4 pcs)
Disconnect the connector of
Plasmacluster Ion Generating Unit.
Push and unlock the
connector, take out the
connector in the direction
of the arrow.
Plasmacluster Ion Generating Unit without sensor.
IG-A20E : 1pc
IG-A40E : 3pcs
without sensor (1pc)
with sensor (1pc)
IG-A40E
without sensor (3pcs)
with sensor (1pc)
Reset button for Plasmacluster Ion Generating Unit
After replacing the Plasmacluster Ion Generating Unit, insert the plug and
press the UNIT RESET Button for 3 seconds.
E-10
Plasmacluster Ion Generating Unit with sensor.
IG-A20E : 1pc
IG-A40E : 1pc
SPECIFICATIONS
Model
Power supply
Fan speed
Power consumption (W)
Operating noise level (dBA)
Airfl ow volume (m3/hour)
Applicable fl oor surface area (m
Ion density (ions/cm3) *
Power cord (m)
Outer dimensions (mm)
Weight (kg)
*1 The target fl oor surface area for which an emitted airborne ion density of about 25,000
3
ions/cm
from the fl oor), during operation at the HIGH mode when the main unit is placed near a
wall.
*2 Ions, counted per cm
1.2m from the floor) during operation at each airstream setting when the main unit is
placed near the wall.
can be measured at a point near the center of the room (at a height of about 1.2m
3
, blown into air near the center of the room (at a height of approx.
HIGHMED.LOWHIGHMED.LOW
22
4540
468390
1
2
) *
2
25,00025,00012,000
594(W) 480(H) 230(D)
IG-A20E
14
23
12,000
10.5
220-240V, 50/60Hz
9
34
306
7,000
2.0
39
47
840648510
940(W) 480(H) 230(D)
IG-A40E
20
4034
50
15.0
10
7,000
ENGLISH
DEUTSCH
The number of ions will vary according to the room conditions and operation mode.
•
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the wall
outlet, this product consumes about 0.8W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.
FRANÇAIS
NEDERLANDS
РУССКИЙ
E-11
TROUBLESHOOTING
Before calling for service, please review the TROUBLESHOOTING chart below.
Since the problem may not be unit malfunction.
Problem
The Plasmacluster Ion Generator does
not work.
fl ashing faster (red)
fl ashing (red)
fl ashing (blue)
fl ashing (blue)
WHAT TO DO
Make sure to put in the plug.
Approx. 2 years and 2 month (Approx
19,000 hours) has been passed.
Replace with a new Plasmacluster Ion
Generating Unit. See page E-8,9,10.
Plasmacluster Ions are not released.
Press the Operation Button and restart.
If all lights keep flashing, replace with new
Plasmacluster Ion Generating Unit. See page E-8,9,10.
• Dust may block the fi lter, clean the fi lter.
Failure
Unplug and ask the store you purchased or
Sharp Sevice Center.
fl ashing (blue)
The discharged air has odor.
A clicking or ticking sound comes from the
unit while operating the Plasmacluster Ion
Generator.
Lighting (yellow)
The Plasmacluster Ion Generator releases
a small trace of ozone which may produce
odor. This is not detrimental to health.
Loudness can be changed depending on
a room humidity, but the effectiveness is
the same. Relocate the Plasmacluster Ion
Generator if necessary.
Filter cleaning time. See page E-7. After
cleaning the filter, press FILTER RESET
Button for 3 seconds.
A discontinuous noise is heard.
The air fl ow decreases.
Filter is getting dirty.
Clean the fi lter.
After cleaning the filter, press FILTER
RESET Button for 3 seconds.
E-12
Attention: Your product is
marked with this symbol. It
means that used electrical
and electronic products
should not be mixed with
general household waste.
There is a separate
collection system for these
products.
A. Information on Disposal for Users (private households)
1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust
bin!
Used electrical and electronic equipment must be treated separately and in
accordance with legislation that requires proper treatment, recovery and recycling of
used electrical and electronic equipment.
Following the implementation by member states, private households within the EU
states may return their used electrical and electronic equipment to designated
collection facilities free of charge*. In some countries* your local retailer may also
take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
If your used electrical or electronic equipment has batteries or accumulators, please
dispose of these separately beforehand according to local requirements.
By disposing of this product correctly you will help ensure that the waste undergoes
the necessary treatment, recovery and recycling and thus prevent potential negative
effects on the environment and human health which could otherwise arise due to
inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the
correct method of disposal.
ENGLISH
For Switzerland: Used electrical or electronic equipment can be returned free of
charge to the dealer, even if you don’t purchase a new product. Further collection
facilities are listed on the homepage of
. Information on Disposal for Business Users.
B
www.swico.ch or www.sens.ch.
1. In the European Union
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the
product. You might be charged for the costs arising from take-back and recycling.
Small products (and small amounts) might be taken back by your local collection
facilities.
For Spain: Please contact the established collection system or your local authority for
take-back of your used products.
2. In other Countries outside the EU
If you wish to discard of this product, please contact your local authorities and ask for
the correct method of disposal.
DEUTSCH
FRANÇAIS
NEDERLANDS
РУССКИЙ
EN
Loading...
+ 74 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.