Sharp HV-50CXE Operation Manual

FEATURES
• Built-in Plasmacluster Ions
• Hybrid humidifier
• Dual (temperature/humidity) sensors
• Auto humidification operation
• Built-in tip-over safety mechanism
Thank you for purchasing the SHARP HV-50CXE.
“Plasmacluster” is a trademark of Sharp Corporation.
MODEL
HV-50CXE
Heat/Evaporation Type Humidifier
OPERATION MANUAL
CONTENTS
• Safety precautions................................ 2
• Effect of Cluster Ions............................ 4
• How the Hybrid Humidifier Works....... 4
• Things to Keep in Mind ........................ 5
• Cautions concerning Usage ................ 6
• Names and Operations of Parts .......... 7
• Operation panel................................... 8
• Correct Usage ....................................... 10
• 1 Preparation ....................................... 10
• 2 Operation .......................................... 11
• 3 Stopping operation .......................... 12
About humidity setting mode, throat moisturizing mode, si­lent mode, continuous operation mode
• About the off timer.............................. 14
• When carrying ..................................... 14
• Cleaning and storage ........................... 15
• When the maintenance lamp lights... 15
• Cleaning procedure ............................ 15
• Tray....................................................... 16
• Humidification filter set ...................... 16
• Air filter ................................................ 17
• Tank / Tank cap ................................... 17
• Unit ....................................................... 17
• Storage................................................. 17
• Troubleshooting.................................... 18
• Specifications........................................ 20
About humidity setting mode, auto humidification
mode, silent mode, continuous operation mode
13
2
SAFETY PRECAUTIONS
Please read before using product and retain in a convenient location for future reference. This instruction manual and product uses various displays for the safe usage.
Results that may occur when mishandling the product by ignoring such displays are categorized as shown below. Read thoroughly and understand the contents before proceeding to the main pages of this instruction manual and be sure to follow the items described.
Do not handle the power cord roughly.
Do not damage the power cord/plug. Do not damage, coat, forcefully bend, pull, twist, pinch or bundle and do not place heavy objects on the power cord/plug. Using a damaged cord/plug may result in electrical shock or fire.
If the power cord is damaged.
Do not use if the power cord/plug is damaged or the power plug inserted into the wall outlet is loose. Electrical shock, short circuit and/or fire may occur as a result. It must be replaced by the manufacturer, It’s service agent or similarly qualified persons in order to avoid a hazard.
Caution to be taken by people nearby.
Keep out of reach of children. Electrical shock and/or bodily injury may occur as a result.
Do not insert objects.
Do not insert objects such as metals (pins, wires, etc.) into the discharge port, intake port or gaps. Electrical shock and/or malfunction may occur, causing bodily injury as a result.
Do not use chlorine bleach/acidic cleaners.
Harmful gas may be generated from the cleaner, causing a health hazard.
Do not use electrical current other than 220 ~ 240V.
Fire, electrical shock and/or malfunction may occur as a result.
Do not modify . Disassembly/repair to be performed only by authorized techni­cian.
Fire, electrical shock and/or bodily injury may occur as a result. For repair, contact your dealer of purchase.
Do not spill liquids into the unit.
Do not expose the unit to liquids or directly insert liquids into the unit. Liquids may enter internal parts, causing electrical shock, short circuit and/or fire as a result.
Periodically remove dust, etc. from the power plug.
Accumulation of dust and humidity may cause bad insulation, resulting in fire.
Take caution of soiling on the floor under and surrounding the unit when us­ing for extensive period in the same location.
Periodically move the product and clean the floor, etc.
Securely insert the power plug into the wall outlet.
Electrical shock, short circuit, smoke and/or fire may occur as a result.
Remove the power plug from the wall outlet when cleaning.
Do not remove plug using wet hands. Electrical shock and/or bodily injury may occur as a result.
If abnormality is noticed (such as burnt odor), stop operation and remove the power plug.
Fire and/or electrical shock may occur as a result. Stop operation and contact your dealer of purchase.
3
Do not place on unstable surface.
Do not tilt or place the unit on an unstable or high surface. The unit may tip over, spilling the water inside.
Do not place on top of electric appliances.
Do not use on top of electric appliances such as heaters, televisions, etc. The unit may top over, causing electric shock and/or short circuit as a result.
Do not drink the water inside the tray.
Water inside may cause sickness.
Always remove by holding the power plug.
Do not pull on the cord and always hold the plug when removing. Electrical shock and/or short circuit may occur, causing fire as a result.
Replace the tank water daily with fresh tap water.
Keep the unit interior free of soiling by cleaning periodically. Using the unit without periodical cleaning will result in the emission of foul odors caused by propaga­tion of molds and bacteria from soiling and water scaling. Occasionally, your body may react sensi­tively to such odors depending on your constitution and may be hazardous to your health. * In this case, consult a physician.
When moving the unit, hold the bottom of the unit securely using both hands and keep level.
Water may spill, wetting the floor. Do not tilt or shake the unit.
When not using, remove the power plug and discharge water.
Empty the water within the tray and tank. Electrical shock, short circuit and/or fire from deterioration of insulation may occur.
4
EFFECT OF CLUSTER IONS
How bacteria-removing ions eradicate floating mold fungus.
Testing organization: Ishikawa Prefecture Preventive Medicine Organization
Bacteria-removing ions (large volume of plus and minus ions) gather around the surfaces of floating mold fungus.
Bacteria-removing ions, consisting of plus ions (hydrogen ions: H+) and minus ions (oxygen ions: O2), react on the surfaces of the floating mold fungus and change to a very powerful active substance of hydroxyl radical OH.
Hydroxyl radical OH removes hydrogen atoms from the cell walls of floating mold fungus and destroys the cell walls. Mold fungus with broken cell walls is self-destroyed!
1
2
3
HOW THE HYBRID HUMIDIFIER WORKS
Hybrid humidifier uses a combination of evaporation method, which humidifies the air by applying air to the humidification fil­ter, and the heat method, which assists evaporation by warming the air using a heater. When starting operation, warm air is applied to the humidification filter for humidification. The heater is turned off when the air reaches the set filter and uses the air in the room to maintain set humidity while con­serving power.
What is a hybrid humidifier?
Humidification using heat/evaporation method
Evaporation-type humidification
Method of applying air when drying clothes quickly .
Heat-type humidification
Method of applying warm air when drying clothes more quickly. More moisture is released as vapor than with cool air.
Tray
Tank
humidification air
Humidification filter
Heater
Fan
Indoor air
Cluster ion generation device
Mold fungus
Mold fungus
Mold fungus
-
5
Steam is not visible from discharge port.
THINGS TO KEEP IN MIND
To correctly detect the temperature/humidity.
• Place the unit free from direct sunlight and warm air from air conditioners and heaters.
• Place the unit where the intake air temperature is between 0 ~ 35°C.
To reduce indoor humidity differences.
•Temperature and humidity will differ between areas near the floor and ceiling. It circulates through indoor air.
Correct placement.
• Always place the unit on a stable, level surface.
• Maintain sufficient spacing as shown in the il­lustration to prevent malfunctions, deterioration, and damage as well as deformation and stain­ing of walls and furniture from humidification.
About the current humidity display.
(Use the humidity display only as a guide.) Current humidity display displays the humidity measured with built-in temperature/humidity sen­sors.
• The temperature will differ depending on the lo-
cation in the room. Select an appropriate loca­tion for the placement of the unit.
• Immediately after the start of operation, the sen-
sors will be influenced by the internal tempera­ture and humidity and requires about 5 minutes for the current humidity display to stabilize.
Steam and mist are not visible.
• Since the unit uses the humidification method of
applying air to the humidification filter and dis­charging humidified air (heat/evaporation ), steam will not be visible as with steam fan type and ul­trasonic type humidifiers.
Discharged air is not warm.
• Since the heat is taken when vaporizing water using the humidification filter even during heat/
evaporation operation, the discharged air will not be warm. Depending on the wideness of the room, the air may even feel cold.
The amount of humidification will vary depending on the tem­perature and humidity.
• Since water is difficult to vaporize
under conditions such as high hu­midity when there is rain or when the temperature is low, the amount of humidified air will be less.
(The tank water will decrease more
slowly.)
Amount of humidification and humidity
(Continuous operation)
250
300
400
500
600
700
030405060
(mL/h)
Amount of humidification
Humidity(%)
Humidity display lamp
Temperature/humidity sensors (Unit interior)
1.5m or more
0.15m or more
Level surface
0.25m or more
6
CAUTIONS CONCERNING USAGE
Be sure to follow the items described below to prevent damage, deterioration and trouble.
Do not block the intake and discharge ports.
Blocking the intake port or discharge port may cause deformation and/or mal­function as a result.
Do not place the unit on thick carpets, thick blankets, etc.
The internal tem­perature will rise and may cause the sen­sors to malfunction as a result.
Do not place in a location exposed to direct wind or in a location where unit is in contact with wall, furniture, cur­tains, ceiling, etc.
Staining and/or de­formation may occur as a result.
Place the unit at least 2m from televi­sions, radios, electromagnetic clocks, etc.
Electrical interfer­ence or malfunction of flow switch may occur as a result.
At least 2m  of space
Do not use at the location with high humidity (about 70% or more).
Malfunction may occur as a result.
Do not place under direct sunlight or near heating apparatus.
Deformation, discolora­tion and/or malfunctions of temperature and hu­midity sensors and safety mechanisms may occur as a result. In addition, the air within the tank may expand, causing the water to spill.
Take caution to freezing water.
If there is a risk of water becoming fro­zen, empty the wa­ter within the tank and tray. Using fro­zen water may cause malfunction to occur as a result.
Clean periodically.
Adhering of large amounts of water scaling may cause malfunction to oc­cur as a result.
Do not use other than tap water.
(Conventional tap water is sterilized with chlorine to suppress propagation of bacte­ria.)
•Using hot water of 40°C or higher, chemi­cal agents, aromatic substances, dirty wa­ter, etc. may cause deformation and/or mal­function to occur as a result.
• Using mineral water, ionized alkaline wa­ter, well water, purified water, etc., may cause increased water scaling, creating an environment for mold fungus and bacteria to easily propagate.
Do not use the unit with the humidifi­cation filter removed.
Malfunction may occur as a result.
Empty water when not in use.
When not in use, empty the water within the tank and tray. Leaving water within the tank and tray will cause mold fungus and bacte­ria to easily propagate.
Loading...