Sharp HV-50CXE Operation Manual

FEATURES
• Built-in Plasmacluster Ions
• Hybrid humidifier
• Dual (temperature/humidity) sensors
• Auto humidification operation
• Built-in tip-over safety mechanism
Thank you for purchasing the SHARP HV-50CXE.
“Plasmacluster” is a trademark of Sharp Corporation.
MODEL
HV-50CXE
Heat/Evaporation Type Humidifier
OPERATION MANUAL
CONTENTS
• Safety precautions................................ 2
• Effect of Cluster Ions............................ 4
• How the Hybrid Humidifier Works....... 4
• Things to Keep in Mind ........................ 5
• Cautions concerning Usage ................ 6
• Names and Operations of Parts .......... 7
• Operation panel................................... 8
• Correct Usage ....................................... 10
• 1 Preparation ....................................... 10
• 2 Operation .......................................... 11
• 3 Stopping operation .......................... 12
About humidity setting mode, throat moisturizing mode, si­lent mode, continuous operation mode
• About the off timer.............................. 14
• When carrying ..................................... 14
• Cleaning and storage ........................... 15
• When the maintenance lamp lights... 15
• Cleaning procedure ............................ 15
• Tray....................................................... 16
• Humidification filter set ...................... 16
• Air filter ................................................ 17
• Tank / Tank cap ................................... 17
• Unit ....................................................... 17
• Storage................................................. 17
• Troubleshooting.................................... 18
• Specifications........................................ 20
About humidity setting mode, auto humidification
mode, silent mode, continuous operation mode
13
2
SAFETY PRECAUTIONS
Please read before using product and retain in a convenient location for future reference. This instruction manual and product uses various displays for the safe usage.
Results that may occur when mishandling the product by ignoring such displays are categorized as shown below. Read thoroughly and understand the contents before proceeding to the main pages of this instruction manual and be sure to follow the items described.
Do not handle the power cord roughly.
Do not damage the power cord/plug. Do not damage, coat, forcefully bend, pull, twist, pinch or bundle and do not place heavy objects on the power cord/plug. Using a damaged cord/plug may result in electrical shock or fire.
If the power cord is damaged.
Do not use if the power cord/plug is damaged or the power plug inserted into the wall outlet is loose. Electrical shock, short circuit and/or fire may occur as a result. It must be replaced by the manufacturer, It’s service agent or similarly qualified persons in order to avoid a hazard.
Caution to be taken by people nearby.
Keep out of reach of children. Electrical shock and/or bodily injury may occur as a result.
Do not insert objects.
Do not insert objects such as metals (pins, wires, etc.) into the discharge port, intake port or gaps. Electrical shock and/or malfunction may occur, causing bodily injury as a result.
Do not use chlorine bleach/acidic cleaners.
Harmful gas may be generated from the cleaner, causing a health hazard.
Do not use electrical current other than 220 ~ 240V.
Fire, electrical shock and/or malfunction may occur as a result.
Do not modify . Disassembly/repair to be performed only by authorized techni­cian.
Fire, electrical shock and/or bodily injury may occur as a result. For repair, contact your dealer of purchase.
Do not spill liquids into the unit.
Do not expose the unit to liquids or directly insert liquids into the unit. Liquids may enter internal parts, causing electrical shock, short circuit and/or fire as a result.
Periodically remove dust, etc. from the power plug.
Accumulation of dust and humidity may cause bad insulation, resulting in fire.
Take caution of soiling on the floor under and surrounding the unit when us­ing for extensive period in the same location.
Periodically move the product and clean the floor, etc.
Securely insert the power plug into the wall outlet.
Electrical shock, short circuit, smoke and/or fire may occur as a result.
Remove the power plug from the wall outlet when cleaning.
Do not remove plug using wet hands. Electrical shock and/or bodily injury may occur as a result.
If abnormality is noticed (such as burnt odor), stop operation and remove the power plug.
Fire and/or electrical shock may occur as a result. Stop operation and contact your dealer of purchase.
3
Do not place on unstable surface.
Do not tilt or place the unit on an unstable or high surface. The unit may tip over, spilling the water inside.
Do not place on top of electric appliances.
Do not use on top of electric appliances such as heaters, televisions, etc. The unit may top over, causing electric shock and/or short circuit as a result.
Do not drink the water inside the tray.
Water inside may cause sickness.
Always remove by holding the power plug.
Do not pull on the cord and always hold the plug when removing. Electrical shock and/or short circuit may occur, causing fire as a result.
Replace the tank water daily with fresh tap water.
Keep the unit interior free of soiling by cleaning periodically. Using the unit without periodical cleaning will result in the emission of foul odors caused by propaga­tion of molds and bacteria from soiling and water scaling. Occasionally, your body may react sensi­tively to such odors depending on your constitution and may be hazardous to your health. * In this case, consult a physician.
When moving the unit, hold the bottom of the unit securely using both hands and keep level.
Water may spill, wetting the floor. Do not tilt or shake the unit.
When not using, remove the power plug and discharge water.
Empty the water within the tray and tank. Electrical shock, short circuit and/or fire from deterioration of insulation may occur.
4
EFFECT OF CLUSTER IONS
How bacteria-removing ions eradicate floating mold fungus.
Testing organization: Ishikawa Prefecture Preventive Medicine Organization
Bacteria-removing ions (large volume of plus and minus ions) gather around the surfaces of floating mold fungus.
Bacteria-removing ions, consisting of plus ions (hydrogen ions: H+) and minus ions (oxygen ions: O2), react on the surfaces of the floating mold fungus and change to a very powerful active substance of hydroxyl radical OH.
Hydroxyl radical OH removes hydrogen atoms from the cell walls of floating mold fungus and destroys the cell walls. Mold fungus with broken cell walls is self-destroyed!
1
2
3
HOW THE HYBRID HUMIDIFIER WORKS
Hybrid humidifier uses a combination of evaporation method, which humidifies the air by applying air to the humidification fil­ter, and the heat method, which assists evaporation by warming the air using a heater. When starting operation, warm air is applied to the humidification filter for humidification. The heater is turned off when the air reaches the set filter and uses the air in the room to maintain set humidity while con­serving power.
What is a hybrid humidifier?
Humidification using heat/evaporation method
Evaporation-type humidification
Method of applying air when drying clothes quickly .
Heat-type humidification
Method of applying warm air when drying clothes more quickly. More moisture is released as vapor than with cool air.
Tray
Tank
humidification air
Humidification filter
Heater
Fan
Indoor air
Cluster ion generation device
Mold fungus
Mold fungus
Mold fungus
-
5
Steam is not visible from discharge port.
THINGS TO KEEP IN MIND
To correctly detect the temperature/humidity.
• Place the unit free from direct sunlight and warm air from air conditioners and heaters.
• Place the unit where the intake air temperature is between 0 ~ 35°C.
To reduce indoor humidity differences.
•Temperature and humidity will differ between areas near the floor and ceiling. It circulates through indoor air.
Correct placement.
• Always place the unit on a stable, level surface.
• Maintain sufficient spacing as shown in the il­lustration to prevent malfunctions, deterioration, and damage as well as deformation and stain­ing of walls and furniture from humidification.
About the current humidity display.
(Use the humidity display only as a guide.) Current humidity display displays the humidity measured with built-in temperature/humidity sen­sors.
• The temperature will differ depending on the lo-
cation in the room. Select an appropriate loca­tion for the placement of the unit.
• Immediately after the start of operation, the sen-
sors will be influenced by the internal tempera­ture and humidity and requires about 5 minutes for the current humidity display to stabilize.
Steam and mist are not visible.
• Since the unit uses the humidification method of
applying air to the humidification filter and dis­charging humidified air (heat/evaporation ), steam will not be visible as with steam fan type and ul­trasonic type humidifiers.
Discharged air is not warm.
• Since the heat is taken when vaporizing water using the humidification filter even during heat/
evaporation operation, the discharged air will not be warm. Depending on the wideness of the room, the air may even feel cold.
The amount of humidification will vary depending on the tem­perature and humidity.
• Since water is difficult to vaporize
under conditions such as high hu­midity when there is rain or when the temperature is low, the amount of humidified air will be less.
(The tank water will decrease more
slowly.)
Amount of humidification and humidity
(Continuous operation)
250
300
400
500
600
700
030405060
(mL/h)
Amount of humidification
Humidity(%)
Humidity display lamp
Temperature/humidity sensors (Unit interior)
1.5m or more
0.15m or more
Level surface
0.25m or more
6
CAUTIONS CONCERNING USAGE
Be sure to follow the items described below to prevent damage, deterioration and trouble.
Do not block the intake and discharge ports.
Blocking the intake port or discharge port may cause deformation and/or mal­function as a result.
Do not place the unit on thick carpets, thick blankets, etc.
The internal tem­perature will rise and may cause the sen­sors to malfunction as a result.
Do not place in a location exposed to direct wind or in a location where unit is in contact with wall, furniture, cur­tains, ceiling, etc.
Staining and/or de­formation may occur as a result.
Place the unit at least 2m from televi­sions, radios, electromagnetic clocks, etc.
Electrical interfer­ence or malfunction of flow switch may occur as a result.
At least 2m  of space
Do not use at the location with high humidity (about 70% or more).
Malfunction may occur as a result.
Do not place under direct sunlight or near heating apparatus.
Deformation, discolora­tion and/or malfunctions of temperature and hu­midity sensors and safety mechanisms may occur as a result. In addition, the air within the tank may expand, causing the water to spill.
Take caution to freezing water.
If there is a risk of water becoming fro­zen, empty the wa­ter within the tank and tray. Using fro­zen water may cause malfunction to occur as a result.
Clean periodically.
Adhering of large amounts of water scaling may cause malfunction to oc­cur as a result.
Do not use other than tap water.
(Conventional tap water is sterilized with chlorine to suppress propagation of bacte­ria.)
•Using hot water of 40°C or higher, chemi­cal agents, aromatic substances, dirty wa­ter, etc. may cause deformation and/or mal­function to occur as a result.
• Using mineral water, ionized alkaline wa­ter, well water, purified water, etc., may cause increased water scaling, creating an environment for mold fungus and bacteria to easily propagate.
Do not use the unit with the humidifi­cation filter removed.
Malfunction may occur as a result.
Empty water when not in use.
When not in use, empty the water within the tank and tray. Leaving water within the tank and tray will cause mold fungus and bacte­ria to easily propagate.
7
FRONT
BACK
NAMES AND OPERATIONS OF PARTS
Tank
Tank handle
Handle
Tank cap
Cluster ion sign (blue)
(Water supply port)
(Page 10)
(Page 10)
(Page 4)
(Page 8~9)
(Page 10)
(Page 11~12)
(Page 16)
(Page 14)
Humidifier discharge port/cluster ion discharge port
Float
(Unit interior)
Operation panel
Air filter
Handle
Power cord
Power Plug
Tray
Temperature/humidity sensors
(Unit interior)
(Unit bottom)
Do not hold this section when carrying as it will become deta­ched.
Dirt and the smell of water are restrained with the sheet containing the zeolite and activated carbon set to the humidification filter.
Humidification filter set
(Humidification filter, zeolite sheet)
Zeolite sheet
(Humidification filter set interior)
(Page 5)
(Page 17)
(Page 17)
(Page 16)
(Page 16)
(Page 14)
( ) indicates main pages of description.
8
NAMES OF PARTS
OPERATION PANEL
Power ON/OFF button
Water supply lamp (red)
The lamp will flash when the water within the tank becomes empty.
(Page 12)
(Page 11)
(Page 11,13)
(Page 11,13)
(Page 11,13)
(Page 11,13)
Power is turned on and off.
Humidity display lamp (green)
When the humidifier is in operation, the current humidity is displayed.
65% or more 55 ~ 64% 45 ~ 54% 35 ~ 44% Less than 35%
Operation display lamp
Displays the operation mode.
<Humidity setting> (Green)
Set humidity guide
About 60% About 50% About 40%
<Auto humidification> (Green)
Performs auto humidification operation.
<Silent> (Yellow)
Performs continuous silent operation.
<Continuous> (Red)
Performs continuous operation using maximum humidifying capacity.
During <Silent> and <Continuous> operations, the unit will stop when the humidity of the intake port reaches 80% or higher. (To prevent condensation.) In case of bad condensation, operate the unit in humidity setting mode (between 40 ~ 50). (Condensation may not be completely removed in some cases.) If the operation display lamp flashes, see Page 18.
9
Reset button
Off timer button
Cluster ion button
Cluster ion lamp
(Green)
(Page 14)
(Page 14)
(Page 15)
(Page 11)
(Page 11)
(Page 11)
(Page 15)
Off timer lamp (green)
Indicates the remaining time of operation.
Maintenance lamp (yellow)
Indicates time for cleaning.
Indicates time for cleaning.
Unit operates for the set time and turns off auto-matically.
Cluster ion operation is turned on and off. (Cluster ion operation can be performed independently.)
The lamp lights during cluster ion operation.
Humidity Select button
Operation mode is set.
10
1
1
2
3
4
5
Tank cap
Tank handle 
Remove the tank
Tank 
Tighten tank cap.
CORRECT USAGE
CAUTION
Preparation
Place the unit on a level surface within the room and insert the power plug into the wall outlet.
• Be sure to place the unit on a stable, level sur­face.
• Place the unit not directly exposed to air from air conditioners and heat from heaters.
• Read “Correct placement” (Page 5)
Hold the tank handle and remove the tank.
Remove the tank cap and pour water.
• Use drinkable tap water. (Conventional tap water is sterilized with chlo­rine to suppress propagation of bacteria.)
• Read “Do not use other than top water” (Page 6)
After supplying water, securely tighten the tank cap.
• Check to see that there is no water leak.
• Be sure to wipe off any excess water around the tank.
Set the tank into the unit.
• Hook the groove on the tank to the tab on the unit. The unit may not operate if the tank is set at an angle. (Align the mark on the tank and the
mark on the unit.)
• Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result.
• Do not use hot water of 40°C or higher, chemical agents, aromatic substances, dirty water , etc. Deforma­tion and/or malfunction may occur as a result.
• Do not use mineral water, ionized alkaline water, well water, purified water, etc. Propagation of mold fungus and bacteria may occur as a result.
• Securely tighten the tank cap. If the tank cap is difficult to tighten, loosen the cap one full turn to properly set the cap to the tank.
Tab on unit
Set the tank.
Tank mark
Unit mark
Groove on tank
Pour water
Tank
Tank cap
11
2
1
2
2
1
Beep Beep
Oreparation
Power ON/OFF button
Humidity select button
Press the Power ON/OFF button.
•The auto humidification mode (green), cluster ion lamp (green) and cluster ion sign (blue) will light and the auto humidification mode operation and cluster ion operation will start.
• For about the first minute of operation, the humidity display lamp (green) will flash in the following order: (Checking of current humidity in progress.)
Press the Humidity Select button and select the desired operation.
The mode will change each time the Humidity Select button is pressed as shown below.
When the cluster ion lamp is off:
When the cluster ion lamp is on:
When performing only cluster ion operation.
(Operation can be made with the tank empty.)
• Empty all water from the tray and tank. Water remaining within the tank and tray will cause humidification.
• Set the Cluster ion button to ON. (Cluster ion lamp and cluster ion sign lit)
• Set the Humidity Select button to OFF. (2 short beeps will be heard.) (Operation display lamp off)
40」「50」 60
(Green) (Green) (Green) (Green)
Continuous
Silent
Auto humidification
(Yellow) (Red)
Humidity setting mode
Auto humidification mode
Silent mode
Continuous operation mode
40」「50」 60
(Green) (Green) (Green) (Green)
Continuous
Silent
Auto humidification
(Yellow) (Red)
Humidity setting mode
Auto humidification mode
Silent mode
Continuous operation mode
Off
Cluster ion operation (humidifier off)
The ozone generated by the cluster ion generator may have an odor. How­ever, the amount of ozone generated is very little and is harmless to the human body , Furthermore, the ozone decomposes quickly so it does not accumulate in the room.
12
3
1
2
NOTE
Stopping operation
Press the Power ON/OFF button.
• All lamps will turn off the operation will stop. To prevent rise in temperature within the unit, the fan will rotate
for about 1 minute after stopping operation. Remove the power plug once the fan has stopped.
• Even during cluster ion operation, press the Power ON/OFF button
to stop operation.
• When the Power ON/OFF button is set to ON after turning off the
unit without removing the power plug, operation will start in the last mode set before the unit was turned off by the memory feature. However, the off timer will not be stored in the memory.
• Remove the power plug when leaving the house, during an earth-
quake or when not using the unit for an extensive period. (Even with the Power ON/OFF button set to OFF, the unit will consume about 0.5W of electricity.)
Turning off the cluster ion sign (blue) during cluster ion operation.
(Cluster ions will be discharged even when the cluster ion sign is turned off.)
Perform the following steps. While the unit is not in operation, press and hold the Hu­midity Select button and Cluster Ion button simulta­neously for more than 1 second.
2 short setting beeps will be heard.
Setting is complete if the cluster ion sign (blue) does not light when pressing the Power ON/OFF button and set­ting the cluster ion operation to ON.
(To return the setting to the original state, repeat step 1 or remove the power plug and reinsert to cancel the setting.)
When the tank is empty.
• Series of long beeps will be heard for about 10 seconds and the
water supply lamp will flash.
• The current humidity lamp and cluster ion sign will turn off and the
humidification operation will automatically stop.
(Humidification operation will restart automatically once the tank is refilled.)
•Water may drop when removing the tank. Drop the all water into the tray before removing.
• During operation, a clicking sound may be heard from the electrical components of the unit. However,
this is not a malfunction.
• Condensation may appear on the surface of the tank after filling when the room temperature is low or
immediately after turning off operation. However, this is not a malfunction.
• Set the tank into the unit slowly without dropping. Malfunction may occur as a result.
• Securely set the tray to the unit. Not setting the tray properly may cause the water supply lamp to flash,
preventing the unit from performing humidification.
CORRECT USAGE
(When thinking that cluster ion sign is too bright to night etc.)
Power ON/OFF button
Beep
Flashing
Long beeps
Water supply lamp
2 short beeps
Press and hold simultaneously for about 1 second.
Humidity select button
Cluster ion button
13
CAUTION
NOTE
About humidity setting mode, auto humidification mode, silent mode, continu­ous operation mode
65%
0 16 18 20 22 24 26 33
60% 55%
Room temperature
About the Humidity Setting Mode
Continuous Operation Mode
Silent Mode
Auto humidification Mode
Humidity setting mode
When operating the unit at the desired humidity setting.
Using the humidity sensor, the unit will automatically switch opera­tions between high, medium, low and off to adjust to the set humidity.
Auto humidification mode
To maintain pleasant humidity.
Using dual (temperature and humidity) sensors, the unit automatically switches operations between high, medium, low and off depending on the room humidity while at the same time checking the room tem­perature for fine humidity control.
Silent mode
To operate the unit silently while sleeping, etc.
The volume of air and humidification discharged are suppressed for silent continuous operation of humidification (low). (Heater OFF)
Continuous operation mode
To operate the unit continuously.
The unit will perform humidification (high) operation continuously (heater ON).
The current humidity is displayed during humidification operation.
• Using lamps, the current humidity of the room is displayed as a guide.
• The humidity may differ depending on the area of the room.
• The current humidity will not be displayed during cluster ion operation.
• During continuous operation mode and silent mode, the unit will stop operate once the hu­midity in the room reaches 80% or higher. Too much humidification may cause condensation on windows and within closets. Auto humidification mode will humidify the room while suppressing dryness of the room.
• Recommended for use while operating air conditioners and heaters as well as the flu sea­son.
• The humidity of the room may not rise effectively if the room exceeds the applicable floor area (Page20) or when ventilating.
• The humidity setting is to be used only as a guide. The humidity will differ depending on the area of the room and differences in the accuracy will also be noticed with other humidity instrumentation.
•Vaporization may not perform effectively during rainy and cold weather.
• Some time is required for the humidification filter to sufficiently absorb water when using the unit for the first time or when not using for an extensive period. In this case, humidification may not perform effectively for some time after starting operation.
• Steam will not be visible since water is evaporated using a low temperature. However, this is not a malfunction.
•A bubble appears in the tank, and has sound to supply water to the tray during operation.
14
1
2
3
CAUTION
NOTE
NOTE
CAUTION
About the Off timer
When carrying
Off timer can be used during humidification and cluster ion operations.
Press the Off Timer button during operation and set the timer.
Check to see that the tank is at least half full before performing operation.
Operation will stop automatically after 2 (or 4) hours.
•To change the set time, press the Off Timer button and select the de­sired time. When “4” is selected, the display will change to “2” when the remaining time becomes less than 2 hours.
The power ON/OFF button is pressed, and the fan stops for about 1 minute rest. Remove the tank, and carry after disconnecting the power plug.
Remove the tank.
• Not removing the tank may cause the water level within the tray to rise and spill.
Hold the handle (unit bottom) and carry slowly using both hands.
•Tilting or shaking the unit may cause the water within the tray to spill.
• The built-in tip-over safety mechanism may cause a clattering sound. How­ever, this is not a malfunction.
Set the tank into the unit.
Hook the groove on the tank to the tab on the unit. The unit may not operate if the tank is set at an angle.
(Align the mark on the tank and the mark on the unit.)
Tank handle  
Tank 
Handle (unit bottom)
2Hours 4Hours OFF
Short  beep 
Short  beep 
Short  beep 
CORRECT USAGE
15
3
4
1
2
3
Pull up and remove the tank.
Pull up and remove the humidification filter set.
Tray
Humidification filter set
Pull out the tray.
CLEANING AND STORAGE
NOTE
1
2
Warning
• Always remove the power plug from the wall outlet when cleaning. Electrical shock or bodily injury may occur as a result.
• Do not use chlorine bleach and acidic cleaners to clean the unit interior. Harmful gases may be generated from the cleaner as a result.
• Do not clean while the unit is in operation or immediately after use. Electrical shock or bodily injury may occur as a result.
When the maintenance lamp lights
When the total humidification time reaches approximately 80 hours, long beeps will be heard for about 10 seconds and the maintenance lamp will light to notify that the unit has not been cleaned for some time.
Clean the unit by following cleaning procedure . Insert the power plug into the wall outlet and press the
Power ON/OFF button. Press and hold the Reset button until a short beep is
heard (about 3 seconds).
(To reset the Maintenance lamp.)
• Degree of soiling will differ depending on the water quality. Clean frequently even if cleaning was per­formed within the last 2 weeks.
• Internal temperature will rise and the amount of humidification will decrease when brownish red and white impurities accumulate within the humidifier filter, tray and tank or when there is accumulation of dust on the air filter. Clean the unit frequently regardless of whether the maintenance lamp turns on to avoid malfunction of the unit.
• After cleaning, be sure to press and hold the Reset button until a short beep is heard (about 3 seconds).
• Since there is the possibility of water spilling when cleaning the unit, move the unit to a location where water may be spilled.
Cleaning procedure
Remove the power plug, and remove all parts.
Empty the water within the tray.
Clean each part, and reattach each part.
Insert the power plug into the wall outlet and press the power ON/OFF button.
CAUTION
• Reattach each part to their original state.
• The tank must be removed first in order to remove the tray.
Pull out the tray slowly to avoid water spills.
(Page 16)
3
Maintenance lamp
Reset button
Beep
Press and hold the reset but­ton about 3 seconds until a short beep is heard (T o reset the maintenance lamp).
5
Tray
16
1
2
Float
Remove soiling 
Allow to sit 
Lattices facing down 
Rinse
3
4
CLEANING AND STORAGE
Empty tray
1
2
Tray
Clean once every 2 weeks.
Empty the water within the tray.
Empty the tray from the direction shown on the right.
Rinse the tray with water and remove soiling.
• Do not remove the float (styrofoam).
• For fine areas, use a cotton swab or tooth brush to remove soiling.
• Wipe and dry any water on the outside of the tray.
Humidification Filter Set
Clean once every 2 weeks.
Place citric acid in water or lukewarm water (about 40°C) and allow to dissolve.
Used volume
20g per 3 liters of water of lukewarm water (about 40°C).
Place the humidification filter set and allow to sit.
(About 60 minutes) Do not remove the humidification filter from the hu-
midification filter set.
Use clean water.
Repeat 2 or 3 times replacing water each time.
Reattach the humidification filter set in the original state.
• Insufficient rinsing will cause citric acid odors, defor­mation and discoloration of unit.
• Citric acid is a type of food additive and is not harm­ful to the human body. However, store in a location that is out of the reach of children.
• Citric acid can be purchased at your local pharmacy or pharmaceutical store.
Replacement guide for humidification filter.
About 6 months.
• Replace the humidification filter even within 6 months if any of the following is noticed: Discoloration (black or yellow), stubborn dirt or white hardened substances that cannot be removed even when cleaning. Filter is damaged or is badly out of shape.
• Dispose of old humidification filters and zeolite sheets as non­flammable garbage.
Humidification  filter set
Reattach
Lattice side
• Model: HV-FP5 for HV-50CXE
• Product name: replacement humidification filter (1 unit)
Separately sold replacement humidification filter includes a humidification filter and zeolite sheet. Set the new hu­midification filter and zeolite sheet to the currently used filter frame.
17
1
2
3
Air filter
Clean weekly.
Remove the air filter from the side of the unit.
Remove dust using a vacuum cleaner.
• Remove dust on the air filter from the side with the lattice facing up (front side) as shown in the illus­tration.
• The air filter can’t be removed from the lattice.
CAUTION
Set the air filter in the original state.
• Humidification volume will decrease as soiling accu­mulates. In addition, the air filter should be cleaned frequently as the humidity sensor may not be able to perform properly.
NOTE
Tank / T ank cap
Clean daily.
Pour small amount of water into the tank, securely tighten the tank cap and shake. When completed, empty the water from the tank.
When using detergent, use diluted neutral detergent. (Rinse thor­oughly so that there is no remain­ing detergent within the tank.)
Unit
Clean once about every month.
Wipe with soft cloth. For stubborn dirt, clean with a cloth
damped with neutral detergent and wipe off using a well-wrung cloth making sure there is no remaining detergent.
CAUTION
•To prevent deformation and dis­coloration, do not wipe with gaso­line, paint thinner, benzene or al­kaline detergent. When using a chemical fiber cloth, make sure to follow the accompanied instruc­tions.
Storage
• After cleaning, wipe off any excess moisture on each part including the tray and humidification filter set and allow to dry sufficiently in the shade.
• Be sure the humidification filter is sufficiently dried. Storing the filter with moisture remaining will cause molding and foul odors.
• Place the unit in the box of purchase along with the instruction manual or place the unit into a plastic bag and store in a location with low humidity.
Air filter
Pull out the tab.
Air filter
Tank
Tank cap
18
TROUBLESHOOTING
Not all problems are caused by malfunctions. Before calling for repair, check to see if the symptom can be cured by following the remedies shown below.
Symptom
Check location and remedy
No steam is discharged
This product uses a method of vaporizing water contained in the humidification filter and thus no steam can be seen.
The unit does not operate (Tank water does not decrease)
Properly insert the power plug.(Page10)
Is the power plug properly inserted into the wall outlet?
Since the humidity is controlled by the unit other than during continuous operation mode and silent mode, humidification will stop when the set humidity is reached.(page13)
The unit will stop when the room humidity reaches 80% or higher even during continuous operation mode or silent mode.(page13)
Continuous operation display lamp flashes
(Tip-over safety mechanism tripped)
Has unit been exposed to vibration or has the unit been tilted?
Place the unit on a stable, level surface and press the Power ON/OFF button again.
Continuous and Auto humidification operation display lamps flash
(Temperature abnormality detection mechanism tripped)
Is the temperature where the unit is placed less than 0 C?
Use the unit in at a room temperature higher than 0 C to avoid water within the unit from freezing.(Page5)
Water Supply lamp flashes even when there is water in the tank
Is the float caught?
The humidity does not rise
Is the room larger than the applicable floor area?
Is the room being ventilated or is the floor carpeted?
Humidity may not rise effectively when ventilating, when the walls and floor are dry and when the floor is carpeted. Check to see if there are any changes when using for 1 ~ 2 weeks.(Page6)
Operation does not stop even after the humidity rises
Use the unit in a location free of direct sunlight and warm air from heaters.(Page6)
Is the unit exposed to direct sunlight or warm air from a heater?
Use the unit in a mode other than continuous and silent.(Page13)
Is the unit operating in continuous or silent mode?
Clean the tray and tank.(page16,17)
Is the tray dirty or is the water old?
Clean the humidification filter set.(page16)
Is there adhering of water scaling or debris on the humidification filter set?
Remove any debris surrounding the float.(page16)
Is the tray securely inserted into the unit?
Securely insert the tray into the unit.(page12,16)
Volume of air discharged has decreased
Is there an accumulation of dust in the air filter (intake port)?
Clean the air filter.(page17)
Is there adhering of water scaling or debris on the humidification filter set?
Clean the humidification filter set.(page16)
There is foul odor
(Page5)
19
Symptom
Check location and remedy
The current humidity is always high
The current humidity is higher than the set humidity
Reading on the current humidity display and that of a hygrometer are different.
Noise is heard
Bubbling sound
Buzzing sound
Air is discharged from the discharge port after stopping operation
Rooms facing north and rooms near bathrooms accumulate steam very easily and thus the humidity may become high.
If symptom persists even when moving the unit to another room, contact your dealer of purchase.
Is the unit being used in a highly-dense or small room?
Circulate the air within the room.(Page5)
There are differences in the humidity depending on the areaof the room.
Accuracy and response speed to changes in humidity are different from the humidity sensor of the humidifier and other humidity instrumentation. (Use the humidity display only as a guide.)
This is the sound that is produced when water is being supplied to the tray from the tank.
The discharge sound of cluster ions may increase or decrease depending on the humidity of the room. The sound may not be noticed at all at times, but the effect of the cluster ions is the same. If the sound becomes irritating, place the unit further away.
After stopping operation, the fan will rotate for about 1 minute to prevent the internal temperature from rising.
SHARP CORPORATION
OSAKA, JAPAN
SPECIFICATIONS
220~240V 50Hz
255W
16W 500mL/h 150mL/h
36dB 23dB
HV-50CXEModel
Voltage/frequency
Reated powew consumption
High(heater on) Silent High(heater on) Silent
Humidification *1
(Room temperature: 20 C; humidity: 30%)
(Room temperature: 20 C; humidity: 30%)
Noise
High Silent High Silent
Continuous humidification
Timer
Tank capacity
2/4 hour select timer
Approx. 4.0 liters
2m
Power cord length Dimensions (mm)
395 (W) X 175 (D) X 377 (H)
Weight
Approx. 5.0kg
Safety mechanisms
High temperature safety mechanism (Thermostat)
Room temperature abnormality detection mechanism (Room thermistor)
Tip-over safety mechanism
About 8 hours
About 26.7 hours
If the fan stops to operate for some reason or when the humidification filter or air filter is continuously used without cleaning, high temperature error is detected and opera­tion is stopped.
When the temperature of the intake port becomes approximately 0 C, operation is stopped for safety.
If the unit is tilted or tips over or if there is vibration, opera­tion is stopped.
TINSJA069TDRZ 03HK
TH
Printed in Thailand
Accompanied document:
Operation manual (1 copy)
*1: The amount of humidification will differ depending on the room temperature/humidity.
The amount of humidification will increase higher the temperature or lower the humidity. The amount of humidification will decrease lower the temperature or higher the humidity. Usage temperature range: room temperature between 0 ~ 35°C
Separately sold part
• Name: Replacement humidification filter (1 unit)
• Model: HV-FP5 for HV-50CXE
Loading...