Sharp FO5700U Service Manual

FO-5700U
SERVICE MANUAL
No. 00ZFO5700USME
F ACSIMILE
MODEL FO-5700
Illustration: FO-5700
In this Service Manual for FO-5700U which is provided with 2nd. cassette (FO-47UC) and memory PWB (FO-1MK), only the information which differs from that for FO-4700U/FO-47UC already issed is contained. For the information not contained, refer to the Service Manual for FO-4700U/FO-47UC (00ZFO4700USME) and FO-1MK (00ZFO1MKCUSME).
Difference between FO-4700U and FO-5700U
FO-4700U FO-5700U
2nd. cassette
Memory PWB
Control PWB unit DCEKC082MXHZZ DCEKC489MXHZZ
CAUTION
This laser facsimile is a class 1 laser product that complies with 21CFR 1040.10 and 1040.11 of the CDRH or IEC60825-1 standard. This means that this machine does not produce a hazardous laser radiation. The use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
This laser radiation is not a danger to the skin, but when an exact focusing of the laser beam is achieved on the eyes retina, there is danger of spot damage to the retina.
The following cautions must be observed to avoid exposure of the laser beam to your eyes at the time of servicing.
1) When a problem in the laser optical unit has occurred, the whole optical unit must be exchanged as a unit, not an individual part.
2) Do not look into the machine with the main switch turned on after removing the toner/developer unit and drum cartridge.
3) Do not look into the laser beam exposure slit of the laser optical unit with the connector connected when removing and installing the optical system.
4) The cover of Laser Printer Unit contains the safety interlock switch. Do not defeat the safety interlock by inserting wedges or other items into the switch slot.
OPTION
(FO-47UC)
OPTION
(FO-1MK)
STANDARD EQUIPMENT
STANDARD EQUIPMENT
Laser Wave Length : 770-810 mm Laser Pulse Times Laser Output Power : 0.37 mW
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintain­ing the safety and performance of the set.
: 49.2 µs
1 - 1
This document has been published to be used for after sales service only. The contents are subject to change without notice.
FO-5700U
CAUTION FOR BATTERY REPLACEMENT
(Danish) ADVARSEL !
Lithiumbatteri-Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandoren.
(English) Caution !
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the equipment manufacturer. Discard used batteries according to manufacturer’s instructions. (Finnish) VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan
tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
(French) ATTENTION
Il y a danger d’explosion s’ il y a remplacement incorrect
de la batterie. Remplacer uniquement avec une batterie du
même type ou d’un type recommandé par le constructeur.
Mettre au rébut les batteries usagées conformément aux
instructions du fabricant.
(Swedish) VARNING
Explosionsfare vid felaktigt batteribyte.
Använd samma batterityp eller en ekvivalent
typ som rekommenderas av apparattillverkaren.
Kassera använt batteri enligt fabrikantens
instruktion.
(German) Achtung
Explosionsgefahr bei Verwendung inkorrekter Batterien.
Als Ersatzbatterien dürfen nur Batterien vom gleichen Typ oder
vom Hersteller empfohlene Batterien verwendet werden. Entsorgung der gebrauchten Batterien nur nach den vom
Hersteller angegebenen Anweisungen.
1 2
FO-5700U
CONTENTS
CHAPTER 1. GENERAL DESCRIPTION
[1] Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
[2] Refer to the service manual of FO-4700U/FO-47UC [3] Refer to the service manual of FO-4700U/FO-47UC [4] Refer to the service manual of FO-4700U/FO-47UC [5] Refer to the service manual of FO-4700U/FO-47UC
CHAPTER 2. ADJUSTMENTS
[1] Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
[2] Diagnostics and service soft switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
[3] Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
[4] Error code table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-36
CHAPTER 3. MECHANICAL DESCRIPTION
[1] Refer to the service manual of FO-4700U/FO-47UC [2] Refer to the service manual of FO-4700U/FO-47UC [3] Refer to the service manual of FO-4700U/FO-47UC [4]
How to install the verification stamp (FO-45VS) refer to the service manual supplement of FO-4700U/FO-47UC
CHAPTER 4. DIAGRAMS
[1] Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
[2] Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
[3] Point-to-point diagram and connector signal name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
CHAPTER 5. CIRCUIT DESCRIPTION
[1] Circuit description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
[2] Circuit description of control PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
[2-1] Circuit description of memory PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
[3] Refer to the service manual of FO-4700U/FO-47UC [4] Refer to the service manual of FO-4700U/FO-47UC [5] Refer to the service manual of FO-4700U/FO-47UC [6] Refer to the service manual of FO-4700U/FO-47UC
CHAPTER 6. CIRCUIT SCHEMATICS AND PARTS LAYOUT
[1] Control PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
[2] LIU PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
[3] Printer PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
[4] Power supply PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-25
[5] Operation panel PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-27
[6] High voltage PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29
[7] Toner empty PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31
[8] 2nd. cassette PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32
[9] Memory PWB circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-34
CHAPTER 7. OPERATION FLOWCHART
[1] Refer to the service manual of FO-4700U/FO-47UC [2] Refer to the service manual of FO-4700U/FO-47UC
CHAPTER 8. OTHERS
[1] Refer to the service manual of FO-4700U/FO-47UC [2] Refer to the service manual of FO-4700U/FO-47UC P ARTS GUIDE
1 - 3
FO-5700U
CHAPTER 1. GENERAL DESCRIPTION
[1] Specifications
• GENERAL
Automat ic dialing Rapid Key Dialing: 48 numbers Speed Dialing: 100 numbers
Memo ry siz e* 2 MB (approx. 116 pages with ECM off) Mode m speed 33,600 bps (max.)
Automatic fallback to lower speeds.
Transmission time* Approx. 2 seconds Toner ca rtridge yield Initial starter cartridge (included with
(4% page coverage) fax machine): 3000 pages (avg.)
(letter paper) Replacement cartridge (FO-47ND):
6000 pages (avg.) (letter paper)
Drum car tridge yield Initial starter cartridge (included with fax machine): 20,000 pages (avg.) Replacement cartridge (FO-47DR):
20,000 pages (avg.)
Resolution Horizontal: 203 pels/inch (8 pels/mm) Vertical: Standard: 98 lines/inch (3.85 lines/mm) Fine /Halftone: 196 lines/inch (7.7 lines/mm) Super fine: 391 lines/inch (15.4 lines mm)
Automatic d ocument 50 pages max. (20 lb letter paper) feeder
Paper capacity 750 sheets (tray and cassette) Compression scheme MMR, MR, MH, Sharp (H2)
(Also supports JBIG)
Halftone (grayscale) 64 levels Applicable telephone line Public switched telephone network Compatibility ITU-T (CCITT) G3 mode Printing resolution Horizontal: 406 lines/inch
(16 lines/mm) Vertical: 391 lines/inch (15.4 lines/mm) PC Printing: 600 dpi
Effective Scanning width 8.3" (210 mm) max. Effectiv e Printing width 8.0" (203 mm) max. Recepti on mo de s Auto/Manual Instascan speed 30 ppm (letter paper) Full Dual Access Yes Copy function Single/Multi/Sort (99 copies/page) Power requirements 120 V AC, 60 Hz Operating temperature 50 - 86°F (10 - 30°C) Humidity 20 to 85% RH Power consumption Standby: 12 W
Maximum: 580 W Dimensions Width: 18.1" (460 mm)
Depth: 15.2" (385 mm) Height: 15.4" (390 mm)
Weight Approx. 41.0 Ibs.(18.6kg)
* Based on ITU-T (CCITT) T est Chart #1 at standard resolution in Sharp
special mode, excluding time for protocol signals (i.e., ITU-T phase C time only).
Option Toner cartridge Drum cartridge PC interface Option memory Verification stamp
: FO-47ND : FO-47DR : FO-47IF : FO-3MK : FO-45VS
Input document size Automatic feeding:
Width: 5.8 to 10.1" (148 to 256 mm) Length: 5.0 to 14.3" (128 to 364 mm) Manual feeding: Width: 5.8 to 11.0" (148 to 279 mm) Length: 5.0 to 17.0" (128 to 432 mm)
Note: This facsimile machine is Year 2000 compliant.
<IMPORTANT PLEASE READ FIRST>
To avoid problems with supplies, please don’t use supplies from other units. Please use new supplies, when supply changes are required.
1 – 1
FO-5700U
TOP VOID LABEL
CHAPTER 2. ADJUSTMENTS
[1] Adjustments
General
Since the following adjustments and settings are provided for this model, make adjustments and/or setup as necessary.
1. Adjustments
Adjustments of output voltage (FACTORY ONLY)
1. Install the power supply unit in the machine.
2. Set the recording paper and document.
3. When the document is loaded, power is supplied to the output lines. Confirm that outputs are within the limits below.
Output voltage settings
CONTROL
PWB
CN5
12
POWER SUPPLY
PWB
Output Voltage limits
+5V MAIN 4.845V~5.355V
+5V SUB 4.845V~5.355V
+24V MAIN 23.04V~24.96V
+24V SUB 23.04V~24.96V
Connector CN4 No. Pin No. CN1
1 11 +5V 2 10 HV C HL 39T VR 4 8 T REM 5 7 T MON 6 6 B MON 7 5 B VR 8 4 C REM
9 3 C MON 10 2 MG 11 1 +24
1
8
1
CN1
12
1
CNPW
1
CNPRT
30
1
11
1
30
CN1
1
CN4
PRINTER
PWB
1
8
CN7
11
CN1
HI VOLTAGE
PWB
IC2
Voltage for adjust
IC2
VR1
VD
+ Check point for voltage
+
Digital multi meter
Fig. 1
Connector CN5 No. Pin No. CNPW
1 +24V SUB 2MG 3MG 4MG 5 +24V MAIN 6 +24V MAIN 7 +5V SUB 8DG
9DG 10 DG 11 +5V MAIN 12 +5V MAIN
Connector CN1 No. Pin No. CN7
1 24 MAIN 2MG 3DG 4 5V MAIN 5 HEATER ON 6FAN 7 FAN LOCK 8 H RELAY OFF
ADJUST VOLT AGE LIST
Top Void Printer Adjust V oltage
Label (mm.) Fig. 2 VR1 Fig. 1
5.5~6.9 4.42V
7.0~8.9 3.87V
9.0~10.9 3.14V
11.0~12.9 2.50V
Fig. 2
13.0~14.9 1.86V
15.0~17.0 1.22V
2. IC protectors replacement
ICPs (IC Protectors) are installed to protect the TX motor drive circuit and verification stamp drive circuit. ICPs protect various ICs and elec­tronic circuits from an overcurrent condition.
The location of ICPs are shown below:
12
1
27 25
CNPW
CNOP
150
130
CNPRT
IC7
F101
CNTXM
CNSTP
11
42
F100
1
1
CNLIU
CONTROL PWB (BOTTOM SIDE)
CNPN
24
CNCIS
9
CNSP
CNSEN
101
1
2
1
8
Fig. 3
(1) F100 (ICPS10) is installed in order to protect IC’s from and
overcurrent generated in the verification stamp drive circuit. If F100 is open, replace it with a new one.
(2) F101 (ICPS18) is installed in order to protect IC’s from an overcurrent
generated in the TX motor drive circuit. If F101 is open, replace it with a new one.
In addition to the replacement of F101 and F100, the factor causing F101 and F100 to open must also be repaired. If not, F101 and F100 will open again. Replacement parts
ICPS10 (Sharp code: VHViCPS10//-1) ICPS18 (Sharp code: VHViCPS18//-1)
3. Settings (1) Dial mode selector
OPTION SETTING: DIAL MODE (Soft Switch No. SW2 DATA No. 1) Use this to set the fax machine to the type of telephone line you are on.
• The factory setting is "TONE".
(step 1) Select "OPTION SETTING".
KEY: DISPLAY:
(step 2) Select "DIAL MODE".
KEY: DISPLAY:
(step 3) Select, using "1" or "2".
KEY:
DISPLAY: TONE SELECTED KEY:
DISPLAY:
(step 4) End, using the "STOP" key.
KEY:
FUNCTION 4
4:OPTIONAL SETTING ENTER #(01-34, ,#)
2
2 DIAL MODE
1
2
PULSE SELECTED
STOP
Cursor When initially registering, the mode shows 1=TONE. When registering again, the mode which was registered formerly is shown.
1=TONE, 2=PULSE
2 – 1
FO-5700U
[2] Diagnostics and service soft switches
1. Operating procedure
Two kinds of diagnoses are supported.
1-1. Fax diagnosis
This diagnosis is concerned with the main body of fax which is used for production and service support.
Entering the diagnostic mode
FUNC
Press display will appear.
ROM: FAB0
FAB0
Then press the and the key or select with the rapid key.
Enter the mode with the (Diag
specifications)
FUNC
02 PRINT AREA 03 ROM & RAM CHECK 04 AUTO FEEDER MODE 05 AGING MODE 06 PANEL CHECK MODE 07 OPTICAL ADJUST MODE 08 PRODUCT CHECK 09 10 11 12 13 14
15 CONF. PASSCODE 16 17 18 19 20
21 22
9 8
START
key. Select the desired item with the
START
9 8 7
START
START01 SOFT SWITCH MODE START START START START START START
START
START START START START START START START
START START START START
START START START
SIGNAL SEND MODE COMM. CHECK MODE MEMORY CLEAR FLASH MEMORY ALL FAX/TEL. ENTRY MODE
DEPT. PASSCODE
PRINT HOLD CODE MEMORY SET MODE STAMP AGING DIAL TEST MODE COPY DIAG MODE SIGNAL SEND MODE2 JBIG TEST MODE
key.
ROM:
FAB0
7
, and
the
following
key
1-2. Print diagnosis
This diagnosis is concerned with the print which is used for production and service support.
Entering the diagnostic mode
FUNC
Press display will appear.
PCU ROM Ver.:
Then press the key andthe key or select with the rapid key.
Enterthe mode with the key. (Diag•specifications)
FUNC
01 02
03
08
09
9 8
START
9 8 6
START START
START
START04
START05 START06 START07 START
START
START10 START11
6
, and
the
following
key. Select the desired item with the
START
PCU ROM Ver.:
START
AREA PRINT MODE CHECK PATTERN 1 CHECK PATTERN 2
CHECK PATTERN 3
PAPER FEED AGING BIAS ADJUST MODE LIFE SET MODE LIFE ALL CLEAR
LIFE ENTRY MODE
TOP ADJUST MODE
LIFE CLEAR MODE
Memory clear when power is turned on
Pressing the START and STOP keys, turn on the main power, and the following message will be displayed.
MEMORY CLEAR EXECUTE ? 1 = YES , 2 = NO
Here, when 1: YES is selected, the memory will be cleared to be ready for operation.
If 2: NO is selected, it will continue ready for operation as it is.
2 – 2
FO-5700U
2. Diagnostic items description
2-1. Fax diagnosis
1) Soft switch mode
In this mode, the soft switch are set and the soft switch list is printed.
Soft switch mode screen
S O F T S W I T C H M O D E S W 0 1 = 0 0 0 0 0 0 0 0
8
Data
1
Switch number selection
1 2 3 4 5 6 7 :DATA No.
Switch
No.
Press START key for setting of the next soft switch. If the soft
switch number is the final, pressing START key will exit the soft switch mode.
Enter two digits of a soft switch number to set the switch number.
If a switch number of unexisting soft switch is entered, key error buzzer sounds to reject the input.
S O F T S W I T C H M O D E S W 0 1 = 0 0 0 0 0 0 0 0
2
Data number selection
E N T E R L A S T D I G I T S W 1
1 6
S O F T S W I T C H M O D E S W 1 6 = 0 0 0 1 0 1 1 0
The cursor position shows the data to be set. Pressing # key moves the cursor to the right. If, however, the cursor is on data number 8, pressing # key shifts the cursor to data number 1 of the next switch number. If the switch number is the final, pressing # key will exit the soft switch mode. Pressing key moves the cursor to the left. If, however, the cursor is on data number 1, pressing key shifts the cursor to data number 1 of the former switch number. If the switch number is 1, pressing key will not move the cursor and the error buzzer will sound.
3
Data setting method
Press the FUNCTION key, and the data at the position of the cursor will be reversed to 0 when it is 1, or to 1 when it is 0. (If the soft switch can be changed at the bit (Refer to 6.), the error buzzer will sound with the process not received.)
4
Outputting method of soft switch list
In the soft switch mode, press the REPORT key, and the soft switch list will be output. If the recording paper runs out or is clogged, the key error buzzer will sound with the process not received.
5
Storage of data
In the following case, the data of the soft switches set will be stored.
It is shifted to set the next soft switch by pressing the START
switch.
It is shifted to set the next soft switch with the [#] key.
It is shifted to set the last soft switch with the [ ] key.
It is shifted to set another soft switch by inputting two digits as the
switch number. (When 2 digits are completely input.)
Output of the soft switch list is started.
6
Inhibition of data change
(This is also applicable for the optional setting.) In the following case, it is inhibited to change the data with the key error buzzer.
Switching ON/OFF of ECM during the use of image memory.
Switching OFF to ON of the print hold function when the print
hold pass code has not yet been registered.
Clearing the print hold pass code when print hold function is ON.
Switching ON/OFF of the print hold function during the use of
memory such as in the case of substitute receiving.
OFF to ON of telephone billing function which is using the image
memory is used (Note: In the existing set, the telephone billing code function is specified from OFF to ON when the timer system communication (including the batch communication) is set.) Here, the memory is usable when the telephone billing code func­tion is on. It can be set from ON to OFF while the memory is used. However, if setting is practically changed even once, it can not be returned from OFF to ON.
Switching ON/OFF of PC interface function during the use of im-
age memory.
OFF to ON of department control function during use of image
memory. (Note: In the existing set, the department control function is set from OFF to ON when the timer communication (including the batch sending) or the memory hold is set.)
ON to OFF of continuous serial polling function when the con-
tinuous serial polling is started. (Note: In the existing set, "ON to OFF of the continuous serial polling function when the continuous serial polling is registered" has been applied, but the conditions are now moderated. How­ever, registration is impossible to the program of the new continu­ous serial polling when the continuous serial polling function is OFF.)
In addition, change of all soft switches during communication
7
Linked change of data (This is the same even in the optional setting.)
When the department control function is off, the multi TTI func-
tion and telephone billing code function are turned off.
2) Print area
According to the size of the specified sheet, the effective printing area is printed.
3) ROM & RAM check
The sum value of ROM, the work and the back-up RAM are checked. The RS232C interface is also checked. If any error occurs, the buzzer will inform it. (Refer to the following table). Finally, the result will be printed. This diagnosis does not check the flash memory. The flash memory is checked with the flash memory test.
Number of buzzer sounds Device checked Remarks 1 time <Short sound> ROM Main 2 times <Short sounds> Integrated ROM Main 3 times <Short sounds> SRAM Main 4 times <Short sounds> DRAM Main
For the short and long sounds, one pattern is as follows.
Main system: 0.5 seconds ON/0.5 seconds OFF
Sub system: 1.00 second ON/0.5 seconds OFF The execution state of checking is as follows. Moreover, the list of the check result is output after checking is ended.
Display during check
ROM CPU SRM DRM
• • • •
Display after check
ROM CPU SRM DRM P P P E P=PASS E=ERROR
ROM/RAM check list output
2 – 3
FO-5700U
4) Auto feeder mode
The auto feed function can be checked by inserting and discharging the document. (The distance between pages can be displayed during op­eration of the scanner.)
1
Check of auto feed function After this mode is activated, set up the document, and press the
STAR T key , and it will be automatically fed. (Before the ST ART key is pressed, the document sensor alone is activated.) Moreover, the document size (A4/B4) and sensor information (A4/B4/ORG) are dis­played when the document sensor is turned.
04 : AUTO FEEDER MODE
After setup of the document
04 : AUTO FEEDER MODE B4 (A4 B4 ORG)
Only the sensor which is activated (fallen down) is displayed.) The paper sheet size (A4/B4) is displayed.
2
Display of distance between pages during operation of the scanner
Soon after this mode is activated, press the FUNCTION key for 5
seconds or more, and the display mode of the distance between pages will be activated. Then, set up the sending paper and select the image quality, and then press the START key, and operation will be started. Be sure to press the FUNCTION key prior to the START key. If the FUNCTION key is not pressed but the STAR T key is pressed, it will operate in the same matter as in the existing auto feeder mode. If the START key is pressed, the FUNCTION key will be invalid hereafter. Therefore, the display mode of the distance between pages and the existing mode can not be changed.
While the sending paper is read, the image quality key can be
input. STD/FINE/S-FINE modes are usable. However, the same operation of FINE will be selected if the intermediate tone is set.
The image quality, the length of the sending page read, the page
distance to the next sending paper and the total of the sending papers read are shown on the display.
When the stop key is pressed or 100 sending papers are read,
the content shown on the display will be totally output as the list after the remaining sending papers are discharged.
5) Aging mode
If any document is set up in the first state (when started), copying will be executed. If it is not set up, "check pattern 1" of the print diagnosis is output at the intervals of 1 time/60 minutes. (A total of 10 sheets are output.)
7) Optical adjust mode
Set documents and press the START key for ordinary copying. According to key operation, copying can be temporarily stopped. STOP key: To temporarily stop reading documents. START key: To start reading documents again. When any document is not set, print area printing is performed.
8) Product check
The diagnosis is used in the production process. After shift to the mode, the following operations are sequentially exe­cuted. At this time, the sensor of read-error can be checked by feeding the B4 document. Set up one short document of B4 size.
1
Memory clear (Same as Diagnosis 11)
2
Panel test (Same as Diagnosis 06)
3
Dial test (Same as Diagnosis 24)
4
Document auto feed
5
ROM & RAM test check (Same as the Diagnosis 03)
6
Flash memory test mode (Same as Diagnosis 12)
7
Registration of fixed data Registration of rapid key No. and other data necessary for produc-
tion. The registered data are shown in the following table. The chain dial is not set for any destination.
Rapid FAX Rapid FAX Rapid FAX Rapid FAX
No. No. No. No. No. No. No. No.
01 20 06 25 11 1 21 01 02 21 07 26 12 2 22 02 03 22 08 27 13 3 23 03 04 23 09 28 14 4 24 04 05 24 10 29 15 5 25 05
8
Transmission check (Same as Diagnosis 10) The soft switches necessary for production are set.
9
Test result print (one sheet)
Memory clear printing Panel test result printing ROM & RAM test result printing
F
Print area printing (one sheet)
6) Panel check mode
This is used to check whether each key is normally operated or not. According to the key input, LCD is displayed. Moreover, during execution, the document reading lamp is turned on. T est results are printed. (The maximum 100 input keys can be printed .) LED repeats lighting at regular intervals in sequence. (Lighting speed is specified separately.) In case of inputting all keys, key input OK is displayed when finishing the STOP key. When pressing the NUMERIC key during panel check, output of DTMF corresponding with the key is started. When pressing other keys, output is stopped.
2 – 4
9) Signal send mode
Rapid key RXX XX : Rapid number SPEED key SXXX XXX
: Speed key number
After shift to the mode, press the START key, and the signals will be transmitted in the following sequence. It can be used to check the modem and so on.
[ 1] No signals [ 2] 4800BPS (V27ter) [ 3] 14400BPS (V . 33) [ 4] 12000BPS (V . 33) [ 5] 14400BPS (V . 17) [ 6] 12000BPS (V . 17) [ 7] 9600BPS (V. 17) [ 8] 7200BPS (V. 17) [ 9] 9600BPS (V. 29) [10] 7200BPS (V . 29) [11] 4800BPS (V27ter) [12] 2400BPS (V27ter) [13] 300BPS (FLAG) [14] 2100Hz (CED) [15] 1100Hz (CNG)
10) Comm. check mode
Turn on the line monitor .
1 2
Turn off the COVER SHEET FUNCTION.
3
Set line equivalence at 0 km.
After the check, it is necessary to be sure to return the aforementioned soft switches into the initial state. (Clear the memory with the diagnosis.)
11) Memory clear
Clear the back-up memory to initialize the soft switches. The flash memory will be initialized. Then, the initialized list be output.
12) Flash memory
The flash memory is checked. The ordinary memories (ROM, SRAM, DRAM) are checked in the ROM & RAM check process. The write/read test is taken every block to print the result.
When an error occurs, the following error buzzer will sound.
Number of buzzer sounds Check device 9 times <Short sounds> Flash memory (Option)
During operation of this diagnosis, dual operation is not possible at all. If this is excessively repeated, it will shorten the life of the flash memory.
13) All FAX/TEL. entry mode
The function is used to simplify the registration of FAX/TEL No. during aging.
1
The diagnosis mode is activated. If anything is not registered in the Rapid number 01 or any program or group is not registered, it will pass the diagnosis without doing anything.
2
The FAX/TEL number (including the substitutive destination) of the Rapid number 01 is copied to the Rapid numbers 02 thru 48.
3
FAX number of the Rapid number 01 is copied to SPEED key numbers 001 thru 200.
FO-5700U
4
If any chain dial is not in the Rapid number, the Rapid numbers 02
thru 48 and SPEED key numbers 001 thru 200 are registered in the
group number 01.
If any chain dial is set, the group will be not produced but the chain
dial setting alone of the Rapid number 01 will be reset.
(In all others except the Rapid number 01, the chain dials will be
continuously set as they are.)
(16th and subsequential letters of the destination name registered in the Rapid number 01 will be discarded.)
14) Dept. passcode
The department passcode list is printed.
15) Conf. passcode
The confidential passcode list is printed. Differing from printing of one box alone soon after registration, the con­fidential passcodes of all boxes are printed.
16) Print hold code
The print lockout passcode No. is printed.
17) Memory set mode
The set and dump list of the memory content is output.
The address (8 digits (P) generally including the bank information is
input, and the data of 2 digits is continuously input.
Inputting is done in the hexadecimal mode. The ten-key is used for 0
thru 9, and the alphabetic keys A (RAPID 01 thru 06) are used for A
thru F.
During data inputting, the address can be moved forward and back-
ward one byte by one byte with " " and "#". (The address prior to the
address 0 is looped as the maximum address.)
The V alidity of the address is not checked. Accordingly, writing/ read-
ing operations are possible in the address of the memory not as-
signed, the address of ROM and so on.
(However, as practical, writing is not done, and the data content runs
short each reading.)
Though writing is possible in the flash memory, a little time is re-
quired.
It is also necessary to take care that the life of the flash memory is
excessively shortened if much data is written in the flash memory.
Since it may run away depending the written content, take minute
care for the writing address.
When the REPORT key is input, the memory dump list is produced
from the displayed address (here, it is limited at the 16-byte bound-
ary address (address with end 0) which does not exceed the speci-
fied address and is just in front.). The dump list is output to a maxi-
mum of 99 pages. If any data of one page can be repeatedly devel-
oped and printed, the list is sufficient. But it is not desired that the
content of plural pages are developed in the memory once and are
then printed. If the STOP key is pressed, it will pass to the diagnosis
after the page which is now being printed is completed printed.
If the address exceeds the maximum address, it will return to the
address 0 and printing will be continued.
18) Stamp aging
Diag mode is left though it doesn’t have this function.
2 – 5
FO-5700U
19) Dial test mode
The mode is used to inspect whether dialing is accurate in two kinds of dial modes . All data which can be dialed in this mode are automatically called up in both PB mode and DP mode.
When this mode is activated, the following operations will be automat­ically executed . Whether the dialed content is right or not is judged with the external instrument which is connected to the line cable.
1
After shift to the FAX diagnosis mode, press RAPID 24. (Also switch the display with the [ ] and [#] keys.)
2
Press the START key.
3
Turn on CML, and dial the following in the PB mode. 1, 2, 3, 4, 5, 6, 7, 8, 9, , 0, #
4
Turn off CML 500 mS alone.
5
Dial the following in the DP mode. 1, 5, 9, 0
6
After dialing, turn off CML.
This mode uses the ordinary auto dial. (Accordingly, the signal sending time and minimum pause are all the same as ordinary. The measurement result in this mode is completely all the same as in the ordinary dial mode. Moreover, the same process as above is also done in the dial test mode which is executed in the product check mode.
20) Copy diag mode
In order to shorten the process time during production, this mode is used to automatically switch the copy mode. Three menus are provided.
1. 1Set up two documents. (In case of two documents or more, there is no problem.
2
Press the STAR T key.
3
Copy 1st document in the fine mode/density AUTO. (One sheet is printed in the ordinary copy mode.)
4
Copy 2nd (subsequential) document in the intermediate tone mode/density DARK. (In the ordinary copying mode, one sheet is printed when the RESOLUTION key is pressed three times.)
When copy test is tried during production or is checked in two modes (fine and intermediate tones), this mode is provided to reduce the trou­blesome work which makes the operator stand aside to change the mode. Accordingly, the fine and intermediate tones are merely switched, and the mode is not switched to another mode. (Input of the image quality/ density key is invalid.)
2. Try the copy in the mode fixed at COPY REDUCE 95% and fine
mode/density AUTO. At this time, don’t change the soft key of COPY REDUCE. (Input of the image quality/density key is invalid.)
3. Continuously try the above items 1 and 2.
21) Signal Send Mode2
The signals concerned with V.34 & V.8 are checked. After this mode is activated, press the START key, and the signals will be sent in the following sequence. It can be used to check the modem.
[ 1] No signal [ 2] 33600BPS [ 3] 31200BPS [ 4] 28800BPS [ 5] 26400BPS [ 6] 24000BPS [ 7] 21600BPS [ 8] 19200BPS [ 9] 16800BPS [10] 14400BPS [11] 12000BPS [12] 9600BPS [13] 7200BPS [14] 4800BPS [15] 2400BPS
22) JBIG Test Mode
Enter the diagnostic mode.
1 2
Press the RAPID22 button. ("22: JBIG TEST MODE" appears.)
3
Press the START key to begin the JBIG test operation. When both tests are completed normally, the buzzer sounds and "JBIG
TEST NORMAL END" appears at the same time. If the decoding test terminates abnormally, the buzzer sounds and "ERROR: JBIG DECODE" appears at the same time. If the encoding test terminates abnormally, the buzzer sounds and "ERROR: JBIG ENCODE" appears at the same time.
2 – 6
FO-5700U
2-2. Print diagnosis
Rapid key 01: Area print mode
The effective printing area frame is printed in the specified sheet size.
1 2 3 4 5 6 7 8 9
4mm ± 2
208mm
1. [Full black pattern]
2. [Intermediate tone 2 pattern]
3. [Intermediate tone 1 pattern]
4mm ± 2.5
4mm
4mm
The left pattern is repeated.
The left pattern is repeated.
Rapid key 05: Paper feed aging
The mode is used for aging related to the printing. In this mode, the following modes are provided.
1
Blank paper aging mode (ALL WHITE AGING)
2
Whole black print aging mode (ALL BLACK AGING)
3
4% printing aging mode (4% AGING) After selecting the paper-pass aging mode in the print diagnosis mode, input the number of each mode above with the ten-key, and the mode will be executed. The detailed specifications of each mode are described as follows. Here, the operation in each mode is stopped only when the STOP key is pressed by the operator or a printing-impossible error oc­curs.
Blank paper aging mode
In the mode, printing is continued in the whole white (white paper) printing pattern until the STOP key is pressed by the operator . (In the printing area)
Whole black printing aging mode
In the mode, printing is continued in the whole black (whole black) printing pattern until the STOP key is pressed by the operator . (In the printing area)
Rapid key 06: Bias adjust mode
The mode is used to adjust the printing density of the printed image. The image printing density is adjustable in seven steps of 1 to 7. For details, refer to the following table. (For selection, use the keys 1 thru 7.)
Image printing density Thin ←→Thick
1234567
Default value
4. [Mesh point pattern] The left pattern is repeated.
5. [Longitudinal strip 2 pattern]
Black 2 dot and white 2 dot are repeated in line.
6. [Lateral strip 2 pattern]
Black 2 line and white 2 line are repeated.
7. [Longitudinal strip 1 pattern]
Black 1 dot and white 1 dot are repeated in line.
8. [Lateral strip 1 pattern]
Black 1 line and white 1 line are repeated.
9. [Full White pattern]
Rapid key 02: Check pattern 1
The lateral stripe 2 pattern is printed on one sheet. (Black 2 line and white 2 line are repeated.)
Rapid key 03: Check pattern 2
The lateral stripe 2 pattern is printed on multiple pages. Press the STOP key to end the printing.
Rapid key 04: Check pattern 3
The intermediate tone 1 is printed on one sheet.
Rapid key 07: Life set mode
The mode is used to set the life counter of the printer and the counter of the auto feeder at desired values. For setting, proceed with the following procedure.
1
When the life counter setting mode is selected, the following will be is displayed.
= 00123
DRUM
LIFE
LIFE
IFE1
L
LIFE2
LIFE3
0
= 00123
0
= 00123
0
= 00123
0
= 00123
0
0
key
MACHINE
# key
FEEDER LI FE= 00123
The cursor blinks at the top data. Five counters can be selected with the "#" and " " keys.
2
In the state 1, input a desired setting number of 6 digits with the ten­key.
3
After input of 6 digits, shift to another counter with the "#" and " " keys as necessary. When all necessary counters are completely in­put, press the START key.
4
"STORED" will be displayed with the set values stored into the memory.
For checking, retry this mode. Note: This counter indicates the printer use conditions such as numbers of printed pages from the beginning of use. In the normal memory clear condition, the counter will not be reset. In conditions including damaged memory contents caused by repairing the panel, this counter should be reset or cleared in addition to the ordi­nary memory clear.
2 – 7
FO-5700U
Rapid key 08: Life all clear
The mode is used to clear the life counter of the printer of the counter of the auto feeder.
Note: The counter shows the operational state of the printer (e.g. how
many sheets have been printed since start of use?). The ordi­nary memory does not reset the counter. Accordingly, it is nec­essary to reset this counter in addition to the ordinary memory clear if the content in the memory on the control PWB is broken because of PWB repair, etc. (In the production stage, it is nec­essary to execute this in the last process.)
Rapid key 09: Life entry mode (For Serviceman temporary counter)
The mode is used to set a desired value for the judgment value (alarm judgment counter value) of the general purpose life counters 1 thru 3 of the printer. If the life of a consumable part (developer, imprinter, etc) is set, the model which has the error display and RMS function will inform RMS when the counter reaches the set value. For setting, proceed with the following procedure.
1
When the life counter setting mode is selected, the following will be
displayed.
# key
LI FE1= 00000
LI FE2= 00000
0
0
key
Rapid key 11: Life clear mode
The mode is used to respectively clear the life counter of the printer and the counter of the auto feeder. For setting, proceed with the following procedure.
1
When the life counter clearing mode is selected, the following will be is displayed. Seven counters can be selected with the "#" and " " keys.
# key
MACHINE
DRUM
FEEDER L I FE LEAR
TONER L I FE LEAR
LIFE
LIFE
L
IFE1
LIFE2
LIFE3
LEAR
C
LEAR
C
LEAR
C
LEAR
C
LEAR
C
C
C
key
LI FE3= 00000
0
The cursor blinks at the top data.
Three counters can be selected with the "#" and " " keys.
2
In the state 1 , input a desired setting number of 6 digits with the ten-
key.
3
After input of 6 digits, shift to another counter with the "#" and " "
keys as necessary. When all necessary counters are completely in­put, press the START key.
4
"STORED" will be displayed with the set values stored into the
memory. For checking, retry this mode.
Note: The counter shows the operational state of the printer (how many
sheets have been printed since start of use? and others). The ordinary memory does not reset the counter. Accordingly, it is necessary to reset the counter or do the clear process in addi­tion to the ordinary memory clear if the content in the memory on the control PWB is broken because of PWB repair, etc. (In the production stage, it is necessary to execute this in the last process.)
Rapid key 10: Top adjust mode
As the method to adjust the top margin for printing, adjust top margin adjusting VR on the PWB. If this mode is used at this time, adjustment is possible without the printing test every time when VR is turned. For the practical use, determine the adjusting value on the basis of the old data, and adjust to the determined value in this mode. Then, check it with the printing test.
2
In the state 1, input the CLEAR key, and the counter will be respec­tively cleared.
3
After one clear, move the cursor to another counter with the "#" and " " keys as necessary, and then press the CLEAR key. When the necessary counters are completely cleared, press the STOP key.
2 – 8
3. How to make soft switch setting
To enter the soft switch mode, make the following key entries in sequence.
FO-5700U
Press
FUNCTION
9 8 7 START 0 1START
S F T S W 1 = 0 0 0 0 0 0 0 0 S F T S W 1 = 1 0 0 0 0 0 0 0 S F T S W 1 = 1 0 0 0 0 0 0 0 S F T S W 1 = 1 0 0 0 0 0 0 0 S F T S W 1 = 1 0 0 0 0 0 0 0
S F T S W 2 = 0 0 0 0 0 0 0 0 S F T S W 99 = 0 0 0 0 0 0 0 0
Press FUNCTION key.
Press key.
Press key.
Bit1 - 8 are set.
Press key during setting.
START
Soft SW2 - 99 are set.
To finish the settings halfway between SW 1 and SW99, press the STOP key. In this case, the setting being done to the SW No. on display will be nullified while settings done to the preceding SW Nos. remain in effect.
The soft switch mode is terminated.
2 – 9
FO-5700U
4. Soft switch description
Soft switch
DATA
SW
NO.
NO.
1 Recall interval Binary input 8421 0 OPTION 2 No. = 1234(Data No.) 1 Set to 1~15 3 EX 0101 0
SW1
SW2
SW3
SW4 3 No. 3 1 00001
SW5
4 eg. Recall interval is set to 5 min. 1 5 Recall times Binary input 8421 0 OPTION 6 No. = 5678(Data No.) 0 Set to 0~14 7 EX 0010 1 8 eg. Recall times is set to 2 times. 0 1 Dial mode PULSE TONE 0 2 Receive mode AUTO MANUAL 1 3 ECM mode Off On 0 OPTION 4 Reserved 0 5 Polling security On Off 1 OPTION 6 Auto cover sheet No Yes 1 OPTION 7 JUNK-FAX function in manual reception Yes No 0 8 JUNK-FAX function Yes No 0 OPTION 1 Number of rings for auto-receive Binary input 8421 0 OPTION 2 (0: No ring receive) No. = 1234(Data No.) 0 Set to 0~9 3 EX 0001 0 4 eg. Number of rings for auto receive is set to 1 time. 1 5 Switch to auto-receive from manual receive Binary input 8421 0 OPTION 6 (0: No switch) No. = 5678(Data No.) 0 Set to 0~9 7 EX 0000 0 8 eg. Switch to auto receive is set to disable. 0
Communication results printout Printed at Printed at Printed at
1 No. 1 0 00110 2 No. 2 0 01010
4 Image addition function to the communication On Off 1 OPTION
result table (for memory transmission only) 5 Reserved 0 6 TEL billing code function On Off 0 OPTION 7 Billing code position Before After 1 OPTION 8 Multi-TTI feature On Off 0 OPTION 1 Time display format 24 hours 12 hours-AM/PM 0 2 Date display format Month-Day-Year Day-Month-Year 1 3 Header print Off On 0 4 Footer print On Off 0 5 Relay data output No Yes 0 6 Substitute reception Off On 0 7 Substitute reception conditions Reception disable without TSI Reception enable without TSI 0 8 CSI transmission Off On 0
ITEM
error only
Switch setting and function
1
error/timer/ memory sion mode only only
transmis- every time
0
Not printed
Printed OPTION
Initial
setting
Remarks
2 – 10
FO-5700U
DATA
SW
NO.
NO.
1 JBIG (Joint Bi-level Image Group) On Off 1 2 JBIG option On Off 0 3 MMR On Off 1 4MR On Off 1
SW6 Modem speed V.33 V.17 V. 29 V. 27ter
5 No. 5 0 0 1 1 1 1 0 0 0 0 1 6 No. 6 1 1 0 0 0 0 0 0 0 0 0 7 No. 7 0 1 0 1 0 1 0 1 1 0 0 8 No. 8 0 0 0 0 1 1 1 1 0 0 0
Reception speed fixed NO V. 17- V. 29- V. 27ter-
1 No. 1 0 1 0 1 0 2 No. 2 0 1 1 0 0 3 DIS receive acknowledge during Twice Once in NSF reception, twice 0 Effective to
G3 transmission in DIS reception international
SW7 comm.
4 Non-modulated carrier in V.29 On Off 0
transmission mode 5 CNG send in manual transmission On Off 1 6 Protocol monitor On Off 0 7 Line monitor On Off 0 8 Max. length for TX/RX/Copy TX: unlimited, RX: unlimited TX/Copy: 1.0m, RX: 1.5m 0
Compromised equalizer 0Km 1.8Km 3.6Km 7.2Km Valid when 1 No. 1 0 0 1 1 0 transmitting 2 No. 2 0 1 0 1 0 3 H2 mode No Yes 0
SW8
4 Signal transmission level Binary input 16 8 4 2 1 0 5 No. = 45678 (Data No.) 1 6 EX 01101 1 7 eg. Signal transmission level is set to -10dBm 0 8 1
ITEM
Switch setting and function
1
14400 12000 14400 12000
0
9600 7200 9600 7200 4800 2400
14400BPS 9600BPS 4800BPS
Initial
setting
Remarks
When 14400BPS MODEM used, setting to 14400BPS is ignored.
2 – 11
FO-5700U
SW
DATA
NO.
NO.
CED tone signal interval 75ms 500ms 750ms 1000ms 1 No. 1 0 0 1 1 0 2 No. 2 0 1 0 1 0 3 Equalization freeze On Off 0
SW9 4 Equalization freeze conditions All 7200bps 0
5 CED detection time 500ms 1000ms 0
Alarm buzzer 3sec 1sec No BEEP No BEEP 6 No. 5 0 0 1 1 0 7 No. 6 0 1 0 1 0 8 Action when RTN received Not Error Error 0 1 Memory retransmission times Binary input 8421 1 OPTION 2 No. = 1234(Data No.) 0 3 EX 1010 1
SW10
SW11
SW12
SW13
SW14
4 eg. Retransmission time set to 10 times. 0 5 Memory retransmission interval Binary input 8421 0 OPTION 6 No. = 5678(Data No.) 0 7 EX 0010 1 8 0 1 Reserved 1 2 Reserved 1 3 Reserved 1 4 Reserved 0 5 Reserved 1 6 Reserved 1 7 Reserved 1 8 Reserved 0 1 Reserved 1 2 Reserved 1 3 Reserved 0
EOL detection timer 13sec 25sec 5sec 5sec 4 No. 4 0 0 1 1 0 5 No. 5 0 1 0 1 0
Processing of DIS reception
after DIS transmission 6 No. 6 0 0 1 1 0 7 No. 7 0 1 0 1 0 8 The change to DB from DP by Yes No 0 1 DTMF output level (High) Binary input 16 8 4 2 1 0 2 No. = 45678 (Data No.) n = 0.5dBm 1 3 EX 01100 1 4 eg. Signal transmission level is set to -10dBm 0 5 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 DTMF output level (Low) Binary input 16 8 4 2 1 1 2 No. = 45678 (Data No.) n = 0.5dBm 0 3 EX 10000 0 4 eg. Signal transmission level is set to -10dBm 0 5 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
Retransmitting command
Breaking Apply to T.30+α
circuit T.30
0
Initial
setting
Remarks
2 – 12
FO-5700U
SW NO.
SW15
SW16
SW17
SW18
SW19
SW20
DAT A
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0
Cl Signal OFF detect enable time 5 No. 5 0 0 0 0 0 0 0 0 6 No. 6 0 0 0 0 1 1 1 1 7 No. 7 0 0 1 1 0 0 1 0 8 No. 8 0 1 0 1 0 1 0 1 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0
Distinctive ringing OFF STD 5 No. 5 0 0 1 0 1 0 1 0 6 No. 6 0 0 0 1 1 0 0 0 7 No. 7 0 0 0 0 0 1 1 0 8 No. 8 0 1 0 0 0 0 0 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 1 5 Reserved 1 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 1 4 Reserved 1 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
(ms)
Switch setting and function
1
200 300 350 400 500 700 1200
RING1 RING2 RING3 RING4 RING5
0
Initial
setting
Remarks
2 – 13
FO-5700U
SW NO.
SW21
SW22
SW23
SW24
SW25
SW26
DAT A
NO.
1 Reserved 1 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 1 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0
Busy tone detection frequency 4 No. 4 0 0 0 0 1 0 5 No. 5 0 0 1 1 0 0 6 No. 6 0 1 0 1 0 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
520~640Hz 300~600Hz 380~500Hz
0
reserve reserve
Initial
setting
Remarks
2 – 14
FO-5700U
SW NO.
SW27
SW28
SW29
SW30
SW31
DAT A
NO.
1 F.A.S.T (RMS) mode On Off 0 2 Reserved 0 3 Verification ST AMP Y e s No 0 4 Summer time (Day light saving) No Yes 1
Key buzzer volume Off HIGH MIDDLE LOW 5 No. 5 0 0 1 1 1 6 No. 6 0 1 0 1 0 7 Reserved 0 8 Reserved 0
Speaker volume HIGH HIGH MIDDLE LOW 1 No. 1 0 0 1 1 1 2 No. 2 0 1 0 1 1 3 Reserved 1 4 Reserved 0
Ringer volume Off HIGH MIDDLE LOW 5 No. 5 0 0 1 1 1 6 No. 6 0 1 0 1 1 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 PC I/F mode On Off 1 OPTION 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Header registration On Off 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Quick on-line function Yes No 1
Cassette selection Manual Auto-1 Auto-2 Auto-1 OPTION 1 No. 1 0 0 1 1 0 2 No. 2 0 1 0 1 1
The first priority cassette None Tray 3 No. 3 0 0 0 0 4 No. 4 0 0 1 1 5 No. 5 0 1 0 1 0
The second priority cassette None Tray 6 No. 6 0 0 0 0 7 No. 7 0 0 1 1 8 No. 8 0 1 0 1 1
ITEM
Switch setting and function
1
1st. Cass. 2nd. Cass. Tr ay OPTION
1st. Cass. 2nd. Cass. Tr ay OPTION
0
Other
Combination
Other
Combination
Initial
setting
0 1
0 1
Remarks
It is effective only when No.31-1/2 are set up of manual
It is effective only when No.31-1/2 are set up of manual
2 – 15
FO-5700U
SW NO.
SW32
SW33
SW34
SW35
SW36
SW37
DATA
NO.
The third priority cassette None Tray 1 No. 1 0 0 0 0 Other 0 2 No. 2 0 0 1 1 Combination 0 3 No. 3 0 1 0 1 1 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Print hold function On Off 0
Heater mode Always on Always off OPTION 1 No. 1 0 0 0 2 No. 2 0 1 1
Density adjustment of print bias Binary input 4 2 1 set to 1~6. 3 No. = 3 4 5 (Data No.) 1: faint ~ 6: deep 1 set to 0, is 4 EX 1 0 0 0 equal to 4 5 eg. Bias is set to level 4. 0 (100).
Drum life limit Near
6 No. 6 0 0 1 1 0 7 No. 7 0 1 0 1 0 8 Reserved 0 1 The default resolution for copying Super fine Fine 0 OPTION 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 1 3 Reserved 1 4 Reserved 1 5 Reserved 0 6 Reserved 1 7 Reserved 1 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 1 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 1 1 Delay time after PC printing Binary input 128 64 32 16 8 4 2 1 0 2 ( n second) No. = 1 2 3 4 5 6 7 8 (Data No.) 0 3 EX 0 0 0 0 0 1 1 0 (= 6 secs) 0 4 0 5 0 6 1 7 1 8 0
ITEM
Limit
Switch setting and function
1
1st. Cass. 2nd. Cass. Tr ay OPTION
19000pcs 15000pcs 15000pcs 16000pcs 20000pcs 16000pcs 20000pcs 20000pcs
0
Initial
setting
Remarks
It is effective only when No.31-1/2 are set up of manual
2 – 16
FO-5700U
SW NO.
SW38
SW39
SW40
SW41
SW42
SW43
SW44
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0
Data reduction AUTO 100%
6
(Prohibition of setting except Auto and 100%) 7 No. 7 0 0 0 8 No. 8 0 0 0 1 Automatic printing of activity report Yes (When memory full) No 2
Print out of total time and total number of pages on activity report 3 Reserved 0 4 Department function On Off 0 5 Department ID digit Binary input 8 4 2 1 0 OPTION 6 No. = 5 6 7 8 (Data No.) 1 7EX01000 8 eg. Department is set to level 4. 0
ITEM
No. 6 0 1 0
Off On 0
Switch setting and function
1
(First data is cleared when memory full)
0
Initial
setting
Remarks
0 OPTION
set to 3 ~ 9
2 – 17
FO-5700U
SW NO.
SW45
SW46
SW47
SW48
SW49
SW50
DAT A
NO.
1 Picture quality priority mode Fine standard 0 OPTION 2 Cut off mode ( When copy mode ) Continue Cut -off 0 OPTION 3 Scanning ratio in memory input 1:1 Reduce 0 4
Overseas communication mode selection function
5 Reserved 0
Reduce ratio when copy mode AUTO 100%
6
(Prohibition of setting except Auto and 100%) 7 No. 7 0 0 0 8 No. 8 0 0 0 1 Reserved 0 2 Reserved 0
Density adjustment (when Fine/STD mode) Normal Faint Deep Deep
3 No. 3 0 0 1 1 0 4 No. 4 0 1 0 1 0
Density adjustment (when Half-tone mode) Normal Faint Deep Deep
5 No. 5 0 0 1 1 0 6 No. 6 0 1 0 1 0 7 MTF correction in Half-tone mode On Off 1 8 MTF intensity in Half-tone mode Strong Weak 0 1 Cassette define LTR/A4:Tray A4 LTR 0 2 Cassette define LTR/A4:Upper A4 LTR 0 3 Cassette define LTR/A4:Lower A4 LTR 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 1 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 1 1 Secure billing code Yes No 0 2 Pause with Z key Ye s No 0 3 Reserved 0 4 Z key pause time (250ms unit) Binary input 16 8421 0 5 No. = 45678(Data No.) 0 6 EX 00000 0 7 eg. Pause time 250ms 0 8 time = (n+1) x 250ms 0 1 Separate feature On Off 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Addition of header (sender information) On Off 1 6 DTMF sending by the panel test On Off 0 7 Power save system Real time Timer 1 8 Reserved 0
ITEM
Yes No 0
No. 6 0 1 1
Switch setting and function
1
0
(when Dark
mode) ONLY
(when Dark
mode) ONLY
Initial
setting
Remarks
Memory Scanning
2 – 18
FO-5700U
SW NO.
SW51
SW52
SW53
SW54
SW55
SW56
SW57
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
0
Initial
setting
Remarks
2 – 19
FO-5700U
SW NO.
SW58
SW59
SW60
SW61
SW62
SW63
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 1 4 Reserved 0 5 Reserved 0 6 Reserved 1 7 Reserved 0 8 Reserved 1 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 1 3 Waiting time after dialing 90 sec 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
Depends on each country’s specifications
0
Initial
setting
0
Remarks
2 – 20
FO-5700U
SW NO.
SW64
SW65
SW66
SW67
SW68
SW69
SW70
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 1 6 Reserved 1 7 Reserved 0 8 Reserved 1 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
0
Initial
setting
Remarks
2 – 21
FO-5700U
SW NO.
SW71
SW72
SW73
SW74
SW75
SW76
SW77
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
0
Initial
setting
Remarks
2 – 22
FO-5700U
SW NO.
SW78
SW79
SW80
SW81
SW82
SW83
SW84
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
0
Initial
setting
Remarks
2 – 23
FO-5700U
SW NO.
SW85
SW86
SW87
SW88
SW89
SW90
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
0
Initial
setting
Remarks
2 – 24
FO-5700U
SW NO.
SW91
SW92
SW93
SW94
SW95
SW96
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0
ITEM
Switch setting and function
1
0
Initial
setting
Remarks
2 – 25
FO-5700U
SW NO.
SW97
SW98
SW99
DATA
NO.
1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Reserved 0 2 Reserved 0 3 Reserved 0 4 Reserved 0 5 Reserved 0 6 Reserved 0 7 Reserved 1 8 Reserved 1
ITEM
Switch setting and function
1
0
Initial
setting
Remarks
2 – 26
Loading...