Sharp AY-XP07ER, AY-XP09ER, AY-XP12ER Service manual

SERVICE MANUAL
SPLIT TYPE
ROOM AIR CONDITIONERS
INDOOR UNIT
AY-XP07ER–AE-X07ER AY-XP09ER–AE-X09ER AY-XP12ER–AE-X12ER
S////AYXP07ER
(INOOR UNIT)
MODEL
MODELS
AY-XP07ER AY-XP09ER AY-XP12ER
OUTDOOR UNIT
AE-X07ER AE-X09ER
AE-X12ER
(OUTDOOR UNIT)
TABLE OF CONTENTS
WIRING DIAGRAMS ..........................................................................................................................................4
REPLACEMENT PARTS LIST
AY-XP07ER / AY-XP09ER / AY-XP12ER.........................................................................................................8
AE-X07ER / AE-X09ER / AE-X12ER..............................................................................................................11
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
Page
SHARP CORPORATION
1
AY-XP07ER–AE-X07ER AY-XP09ER–AE-X09ER AY-XP12ER–AE-X12ER
SPECIFICATIONS
I
MODEL
NDOOR UNIT
ITEMS AY-XP07ER AE-X07ER AY-XP09ER AE-X09ER AY-XP12ER AE-X12ER Cooling capacity
Heating capacity
(Min. ~ Max.) (Min. ~ Max.)
kW 2.1 (0.9 _ 3.0) 2.6 (0.9 _ 3.0) 3.5 (0.9 _ 4.0) kW 3.0 (0.9 _ 4.0) 3.6 (0.9 _ 5.0) 4.6 (0.9 _ 6.0)
Moisture removal(at cooling) Liters/h
Electrical data
Phase Single Rated frequency Hz 50 Rated voltage V 230 Rated current Cool A 2.6 (0.8 _ 4.6) 3.3 (0.8 _ 4.6) 4.6 (0.8 _ 6.4) (Min - Max.) Heat A 3.7 (0.7 _ 6.5) 4.1 (0.7 _ 6.5) 5.2 (0.7 _ 8.1) Rated input Cool W 510 (150 _ 900) 650 (150 _ 900) 960 (150 _ 1400) (Min - Max.) Heat W 730 (130 _ 1400) 900 (130 _ 1400) 1190 (130 _ 1800)
Cool % 85 86 91
Power factor Heat % 86 95 99
Type Hermetically sealed rotary type
Compressor Model 5RS092XDF
Oil charge 320cc (RB68A or Freol Alphc 68M) Evaporator Louver Fin and Grooved tube type
Refrigerant system Condenser Corrugate Fin and Grooved tube type
Control Expansion valve Refrigerant (R410A) De-lce system Micro computer controled reversed systems High dB(A) 38 46 43 48 45 49
Noise level (at cooling)
Low dB(A) 32 34 38 – Soft dB(A) 26 28 31
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
1000g 1000g 1080g
Fan system
Drive Direct drive Air flow quantity High m3/min. 7.8 22 9.9 22 11.2 24 (at cooling) Low m3/min. 6.8 7.7 9.0
Soft m3/min. 5.2 6.0 6.8
Fan
Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling Flare type Refrigerant tube size Gas, Liquid 3/8", 1/4" 1/2", 1/4" Drain piping mm O.D ø 18
Others
Compressor: Thermal protector
Safety device Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters Polypropylene net (Washable)
Width mm 810 730 810 730 810 780
Net dimensions Height mm 285 540 285 540 285 540
Depth mm 240 250 240 250 240 265
Net weight kg 11 36 11 36 11 37 Note: The condition of star " " marked item are ‘ISO5151’ : 1994(E), condition T1.
2
EXTERNAL DIMENSIONS
790
AY-XP07ER–AE-X07ER AY-XP09ER–AE-X09ER AY-XP12ER–AE-X12ER
58
INVERTER AIR CONDITIONER
810
CRMC-A442JBE0
R03(AAA) 2PCS.
SHARP CORPORATION
175
Figure E-1. INDOOR UNIT
A
135
240
285
18.5
22.0
72
540
37.5
12
ø 4.5
58
B
Figure E-2. OUTDOOR UNIT
299
324
14
AE-X07ER AE-X09ER AE-X12ER
C
165
167.5
A 515 540
81
B 730 780
136
C 250 265
3
AY-XP07ER–AE-X07ER AY-XP09ER–AE-X09ER AY-XP12ER–AE-X12ER
WIRING DIAGRAMS
LED INDICATION FOR SELF-DIAGNOSIS
Temperature Indicator Blinking No.
Short circuit of the Thermistor
1 2
Overheat error (compressor and cycle) Open circuit of the Thermistor
5 6
Abnormal DC current
7
Abnormal AC current
9
Abnormal Thermistor or four way valv
11
Abnormal outdoor fan motor Rotation error of the compressor or compressor lock
13 14
Abnormal PAM voltage and PAM clock signal
17
Open circuit of serial signal line Short circuit of serial signal line
18
Abnormal fan motor of indoor unit
19
<Indication of the abnormal condition> LED indicator will blink, if the set is in abnormal condition.
Abnormal contents
Figure W-1. Wiring Diagram for AY-XP07ER / AY-XP09ER / AY-XP12ER
WIRING DIAGRAM
INDOOR UNIT
TERMINAL BOARD1
POWER SUPPLY
SINGLE PHASE
LOUVER MOTOR
(TOP)
LOUVER MOTOR
(BOTTOM)
ROOM TEMP. THERMISTOR
PIPE TEMP.
THERMISTOR BCN201 CN102 RECEIVER
BOARD UNIT
GREEN-YELLOW
N
BLUE
1
BLACK
TH1
YELLOW
TH2
ORANGE
BCN101
CN101
DISPLAY BOARD UNIT
CNA CNB
CN2 CN3
BCN1
BCN3
R76
C23 NF2 C28
CN5
<CB878>
IN OUT
RY1
NF1
NR1
SSR
CLUSTER
GENERATOR
CONTROL BOARD UNIT
DB1
C14A
FU2
C97 C96
FAN MOTOR
250V
2A SUPPLY UNIT
3.15A
C99 C98
FU1
250V
SERIAL SIGNAL
CIRCUIT
POWER
CN1
OUTDOOR UNIT
TERMINAL BOARD 2 TERMINAL BOARD
BLACK
BLUE RED
N
1
2
EVAPORATOR
S N
N
1
2
Figure W-2. Wiring Diagram for AE-X07ER / AE-X09ER / AE-X12ER
4
ELECTRICAL PARTS
For Model AY-XP07ER / AY-XP09ER / AY-XP12ER
DESCRIPTION MODEL REMARKS Indoor fan motor MLB084 DC Motor Indoor fan motor capacitor –– Transformer –– FUSE1 QFS-GA052JBZZ (250V, 3.15A) FUSE2 QFS-GA051JBZZ (250V, 2A)
For Model AE-X07ER / AE-X09ER / AE-X12ER
DESCRIPTION MODEL REMARKS Compressor 5RS092XDF D.C. brush-less motor Outdoor fan motor ML-A902 DC Motor Outdoor fan motor capacitor –– WPE1 QFS-GA050JBZZ(250V, 1A) WPE101 QFS-GA051JBE0(250V, 2A) WPE3 QFS-GA052JBZZ(250V, 3.15A) WPE5 QFS-GA065JBZZ(400V, 20A)
QFS-GA066JBZZ(400V, 15A)
AY-XP07ER–AE-X07ER AY-XP09ER–AE-X09ER AY-XP12ER–AE-X12ER