Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord
1
can result in damage to the unit and cause electrical shock.
Be careful not to expose your body directly to the outlet air for a long time. It may affect
2
your physical conditions.
When using the air conditioner for infants, children, elderly, bedridden, or disabled people
3
make sure the room temperature is suitable for those in the room.
E-16
ENGLISH
Never insert objects into the unit. Inserting objects can result in injury due to the high
4
speed rotation of internal fans.
Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe,
5
water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause
electric shock.
If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation
6
immediately and turn the circuit breaker OFF.
Follow local rules and regulations for power supply cord cabling. Improper cable
7
connection can cause the power supply cord, plug and the electrical outlet to overheat
and cause fire.
Use only the manufacture-specified power cord for replacement. Replacement should be
8
performed by a qualified technician or a service person.
WARNINGS FOR INSTALLATION / REMOVAL / REPAIR
• Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric
shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the
installation/removal/repair of the unit.
This equipment complies with the requirements of Directives 89/336/EEC and 73/23/
EEC as amended by 93/68/EEC.
E-1
PRECAUTIONS
CAUTIONS FOR USE
Open a window or door periodically to ventilate the room, especially when using gas
1
appliances. Insufficient ventilation may cause oxygen shortage.
Do not operate the buttons with wet hand. It may cause electric shock.
2
For safety, turn the circuit breaker off when not using the unit for an extended period of
3
time.
Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly
4
in place.
Do not put anything on the outdoor unit nor step on it. The object or the person may fall
5
down or drop, causing injury.
This unit is designed for residential use. Do not use for other applications such as in a
6
kennel or greenhouse to raise animals or grow plants.
Do not place a vessel with water on the unit. If water penetrates into the unit, electrical
7
insulations may deteriorate and cause electric shock.
Do not block the air inlets nor outlets of the unit. It may cause insufficient performance
8
or troubles.
Be sure to stop the operation and turn the circuit breaker off before performing any
9
maintenance or cleaning. A fan is rotating inside the unit and you may get injured.
Do not splash or pour water directly on the unit. Water can cause electrical shock or
10
equipment damage.
This appliance is not intended for use by young children or infirm persons without
11
supervision.
Young children should be supervised to ensure that they do not play with the appliance.
CAUTIONS FOR LOCATION / INSTALLATION
• Make sure to connect the air conditioner to power supply of the rated voltage and
frequency.
Use of a power supply with improper voltage and frequency can result in equipment
damage and possible fire.
• Do not install the unit in a place where inflammable gas may leak. It may cause fire.
Install the unit in a place with minimal dust, fumes and moisture in the air.
• Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting
of the room, furniture etc.
• Make sure a leak breaker or a circuit breaker is installed, depending on the installation
location, to avoid electrical shock.
E-2
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
INDOOR TEMP. OUTDOOR TEMP.
COOLING
HEATING
D.B. = Dry-bulb W.B. = Wet-bulb
upper limit
lower limit
upper limit
lower limit
32˚C D.B.43˚C D.B.
23˚C W.B. -
21˚C D.B.21˚C D.B.
15˚C W.B. -
27˚C D.B.24˚C D.B.
-18˚C W.B.
20˚C D.B.-7˚C D.B.
--8˚C W.B.
• The built-in protective device may prevent the unit
from operating when used
out of this range.
• Condensation may form on
the air outlet if the unit operates continuously in the
COOL or DRY mode when
humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re-start in the same settings which were active before
the power failure, except for timer settings.
If the timers were set before a power failure, they will need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on
to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
• When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an
automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the
inside and outside fans stop operating.
• After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
HEATING EFFICIENCY
• The unit employs a heat pump that draws heat from the outside air and releases it into the room.
The outside air temperature therefore greatly affects the heating efficiency.
• If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
• It takes time to warm up and heat the entire room because of the forced air circulation system.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
ENGLISH
SET THE CORRECT TEMPERATURE
• Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower
in the HEAT mode will save approximately 10 percent in power consumption.
• Setting the temperature lower than necessary during cooling operation will result in increased
power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
• Blocking direct sunlight during cooling operation will reduce power consumption.
• Close the windows and doors during cooling and heating operations.
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR
CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION
MAKE MOST OF THE TIMER OFF FUNCTION
DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN
EXTENDED PERIOD OF TIME
• The indoor unit still consumes a small amount of power when it is not operating.
! Inlet (Air)
@ Interconnecting Cord
# Refrigerant Tube and
$ Outlet (Air)
E-5
PART NAMES
REMOTE CONTROL
DISPLAY
FULL
POWER
MODE
FAN
SWING
1h
CLEAN
SET/C
1
2
3
4
5
6
7
8
9
0
q
w
e
r
t
y
u
i
o
1 TRANSMITTER
2 DISPLAY (Liquid Crystal Display)
3 DISPLAY Button
4 FULL POWER Button
5 ON/OFF Button
6 THERMO. (Thermostat) Button
7 MODE Button
8 FAN Button
9 ONE-HOUR OFF TIMER Button
0 TIMER ON Button (for setting the timer)
q TIMER OFF Button (for setting the timer)
w PLASMACLUSTER Button
(only for models AY-XPM7CR/AY-XPM9CR/AYXPM12CR)
e TIME ADVANCE Button
r TIME REVERSE Button
t SELF CLEAN Button
(only for models AY-XPM7CR/AY-XPM9CR/AYXPM12CR)
y TIMER SET/CANCEL Button
u Indicates BATTERY COMPARTMENT is
below this mark
i CLOCK Button
o SWING Button
L.C.D. REMOTE CONTROL DISPLAY
p THERMOSTAT SETTING FOR AUTO AND
DRY MODES
a SELF CLEAN SYMBOL
(only for models AY-XPM7CR/AY-XPM9CR/
AY-XPM12CR)
s TRANSMITTING SYMBOL
d MODE SYMBOLS
: AUTO: DRY
: HEAT: COOL
f TEMPERATURE INDICATOR
g FULL POWER SYMBOL
h FAN SPEED SYMBOLS
: AUTO: LOW
: HIGH: SOFT
E-6
p
a
s
d
AM
PM
AM
PM
AUTO
C
j TIMER ON INDICATOR/CLOCK
Indicates the on timer preset time or current
time.
k TIMER OFF INDICATOR
Indicates the preset time for off timer or onehour off timer.
l PLASMACLUSTER SYMBOL
(only for models AY-XPM7CR/AYXPM9CR/AY-XPM12CR)
f
g
h
j
k
l
SETTING DUST COLLECTION FILTER AND DEODORANT FILTER
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
The dust collection filter and the deodorant filter are packed as accessory of this unit.
During operation of the air conditioner, the filters remove dust and tobacco smoke
from the air and discharges clean air.
Take out the air filters.
1
1 Open the open panel.
1
2
DUST COLLECTION FILTER (gray)
Set the black side facing upward.
3
2 Push the air filters up slightly to unlock
them.
3 Pull the air filters down to remove
them.
ENGLISH
Filter stopper
DEODORANT FILTER (green)
Filter stopper
3
2
1
Set the dust collection filter and the deo-
2
dorant filter under the filter stoppers located on the air filter.
Reinstall the air filters
3
1 Reinstall the air filters in the original
positions.
2 Close the open panel.
3 Push the arrow-marked of the panel
firmly to lock it in place.
Precautions
• The filters are sealed in a plastic bag to keep their dust collection effect.
Do not open the bag until using the filters. (Otherwise the filters life may get shorter.)
• Do not expose the filters to direct sunlight. (Otherwise they may deteriorate.)
E-7
USING THE REMOTE CONTROL
LOADING BATTERIES Use two size-AAA (R03) batteries.
Remove the remote control
1
cover.
Insert batteries in the compart-
2
ment, making sure the ± and
— polarities are correctly
aligned.
• The display indicates "AM
6:00" when batteries are properly installed.
Reinstall the cover.
3
+
NOTES:
• The battery life is approximately one year in normal use.
• When you replace the batteries, always change both batteries, and make sure
they are the same type.
• If the remote control does not operate properly after replacing the batteries, take
out the batteries and reinstall them again after 30 seconds.
• If you will not be using the unit for a long time, remove the batteries from the
remote control.
Remote control
cover
+
-
HOW TO USE THE REMOTE CONTROL
Point the remote control towards
the unit’s signal receiver window
and press the desired button. The
unit generates a beep when it receives the signal.
• Make sure there is no curtain or other
object between the remote control and
the unit.
• The remote control can send signals
from up to 7 metres away.
E-8
CAUTION
• Do not allow the signal receiver window to receive strong direct sunlight, since it can
adversely affect its operation. If the signal receiver window is exposed to direct sunlight,
close a curtain to block the light.
• Using a fluorescent lamp with a quick starter in the same room may interfere with
transmission of the signal.
• The unit can be affected by signals transmitted from the remote control of a television,
VCR or other equipment used in the same room.
• Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit
and remote control from moisture and shock which can discolour or damage them.
SET CURRENT CLOCK TIME
ENGLISH
There are two clock modes:
12-hour mode and 24-hour
mode.
MODE
FAN
SWING
The PLASMACLUSTER and the SELF
CLEAN buttons are provided only on
models AY-XPM7CR/AY-XPM9CR/
AY-XPM12CR.
1h
CLEAN
SET/C
2
3
1
Example: 5 o'clock in the afternoon
ClockDisplay
12-hour modePM 5:00
24-hour mode17:00
To set to the 12-hour mode, press the
1
CLOCK button once in the first step.
To set to the 24-hour mode, press the
CLOCK button twice in the first step.
Press the TIME ADVANCE or REVERSE
2
button to set the current time.
• Keep the button pressed to advance
or reverse the time display quickly.
Press the SET/C button.
3
• The colon (:) blinks to indicate that the
clock is functioning.
NOTE:
• The current time cannot be set when the
timer is operating.
E-9
BASIC OPERATION
1
AM
Press the MODE button to select the operation mode.
AUTO HEAT COOL DRY
DISPLAY
FULL
POWER
MODE
FAN
SWING
1h
CLEAN
SET/C
2
5
Press the ON/OFF button to start opera-
2
tion.
• The red OPERATION lamp ( ) on the unit
will light.
3
Press the THERMO. button to set the de-
1
4
3
sired temperature.
• In the AUTO and
DRY mode, the temperature can be
changed in 1°C
incerments within the
range of 2°C higher
to 2°C lower from the
temperature automatically determined
by the air conditioner.
• In the COOL and HEAT modes, the temperature can be set within the range of 18 to
32°C.
Press the FAN button to set the desired fan
4
speed.
AUTO SOFT LOW HIGH
(Example: 1°C higher)
(Example: 2°C lower)
C
C
• In the DRY mode, the fan speed is preset to
AUTO and cannot be changed.
To turn off the unit, press the ON/OFF but-
The PLASMACLUSTER and the
SELF CLEAN buttons are provided
only on models AY-XPM7CR/AYXPM9CR/AY-XPM12CR.
NOTES:
This air conditioner is a multi-type, and two (or three) indoor units are connected to one outdoor unit.
When the setting mode differs among indoor unit(s), the indoor unit(s) operated later may not work.
• When the indoor unit(s) is/are operating in HEAT mode, the remaining unit(s) can not operate in
COOL or DRY mode.
• When the indoor unit(s) is/are operating in COOL or DRY mode, the remaining unit(s) can not
operate in HEAT mode.
When the mode of the indoor unit(s) later operated is/are different from those which is/are in
operation, 4 seconds later, a long BEEP will be emitted and the temperature indicator on the
indicator panel will indicate" " and the OPERATION lamp and TIMER lamp will blink alternately.
This shows that the later operated unit(s) is/are not working. In such case, change the remote
control's mode and send the same mode signal which the other indoor unit(s) is/are operating in. The
BEEP will be emitted twice from the indoor unit(s) later operated, and the unit(s) will operate.
5
ton again.
• The red OPERATION lamp ( ) on the unit
will turn off.
E-10
TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting and mode are automatically selected according to
the room temperature and outdoor temperature when the unit is turned on.
Modes and Temperature Settings
26
Heat
(24¡C)
indoortemp.
(¡C)
outdoor
281810034
Cool
(24¡C)
Heat
Heat
(23¡C)
(22¡C)
the figures in ( ) are temperature settings
Dry
RoomTemp.
()
-2¡C
Cool
(25¡C)
temp.
Cool
(26¡C)
• During operation, if the outdoor temperature
(¡C)
changes, the temperature settings will automatically slide as shown in the chart.
• Mode of the unit operated first will have
priority over other unit(s) without reference
to the chart.
TIPS ABOUT INDICATOR PANEL
ENGLISH
The indicator panel will change each time you press
the DISPLAY button in the following manner.
(AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
DISPLAY
FULL
POWER
(AY-XM7CR/AY-XM9CR/AY-XM12CR)
The room
ECO
POWER
MONITOR
Room Temp.
Lamp
temperature
Indiactor
temperature and
POWER MONITOR
are displayed.
Room Temp. Lamp
temperature
Indiactor
ECO
POWER MONITOR
The outdoor
ECO
Outdoor Temp.
Lamp
temperature and
POWER MONITOR
are displayed.
Outdoor Temp. Lamp
ECO
No display.
POWER MONITOR
When the room temperature or the outdoor temperature is displayed, the POWER MONITOR
will light up in 4 levels for COOL and HEAT modes (3 levels for DRY mode), to indicate the
operation power. When the air conditioner is operating at maximum power in the COOL and
HEAT modes, "POWER" will light and "ECO" will turn off on the indicator panel.
NOTES:
• The displayed temperatures are rough estimates and may vary from the actual temperatures.
• Temperature display ranges
Room temperature: 0°C ~ 40°C ( is displayed when less than 0°C and when higher
than 40°C)
Outdoor temperature: -9°C ~ 45°C ( is displayed when less than -9°C and when
higher than 45°C)
• is displayed during the first 120 seconds of operation while the temperatures are being
detected. (Temperature detection may more than 120seconds when other unit(s) is/are
already being operated.)
• is displayed for 5 seconds when the unit is not in operation.
E-11
ADJUSTING THE AIR FLOW DIRECTION
VERTICAL AIR FLOW DIRECTION
The air flow direction is automatically preset in each mode as follows for optimum
comfort:
COOL and DRY modesHorizontal air flow
HEATmodeDiagonal air flow
HOW TO ADJUST THE AIR FLOW DIRECTION
Press the SWING button on the
remote control once.
• The vertical adjustment louvre
will change its angle continuously.
COOL and DRY modes
Adjustment range
Press the SWING button again
when the vertical adjustment
louvre is at the desired position.
• The louvre will stop moving within
the range shown in the diagram.
• The adjusted position will be
memorized and will be automatically set to the same position
when operated the next time.
The adjustment range
is narrower the SWING
range in order to prevent condensation from
dripping.
HORIZONTAL AIR FLOW DIRECTION
Hold the horizontal adjustment
louvre as shown in the diagram
and adjust the air flow direction.
HEAT mode
The range is wide so the
air flow can be directed
toward the floor.
CAUTION
Never attempt to adjust the vertical adjustment louvres manually.
• Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction
when the remote control is used for the adjustment.
• When the vertical adjustment louvre is positioned at the lowest position in the COOL or
DRY mode for an extended period of time, condensation may result.
Do not adjust the horizontal adjustment louvre extremely to the right or left when operating
the air conditioner with fan speed "SOFT" for an extended period of time.
Condensation may form on the louvres.
E-12
FULL POWER OPERATION
In this operation, the air conditioner works at maximum power to makes the room
cool or warm so rapidly that you can use it just after you come home.
To activate the FULL POWER operation, press the
1
FULL POWER button during operation.
• The remote control will display .
• The temperature display will go off.
PM
TO CANCEL
Press the FULL POWER button again.
DISPLAY
FULL
POWER
1
• FULL POWER operation will also be cancelled when
the operation mode is changed, or when the unit is
turned off.
NOTE:
• You cannot set the temperature and fan speed during the FULL POWER operation.
ONE-HOUR OFF TIMER
When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour.
Press the ONE-HOUR OFF TIMER button.
1
• The remote control displays “ ”.
• The orange TIMER lamp ( ) on the unit will light up.
• The unit will stop operating after one hour.
ENGLISH
TO CANCEL
Press the TIMER CANCEL (SET/C) button.
MODE
FAN
The PLASMACLUSTER and the
SELF CLEAN buttons are provided
only on models AY-XPM7CR/AYXPM9CR/AY-XPM12CR.
1h
1
• The orange TIMER lamp ( ) on the unit will turn off.
Or, turn the unit off by pressing the ON/OFF button.
• The red OPERATION lamp ( ) and the orange
TIMER lamp ( ) on the unit will turn off.
NOTES:
• The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF
operations.
• When the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will
operate for an hour with the formerly set condition.
• If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER
activates, press the ONE-HOUR OFF TIMER button again during operation.
• If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting.
E-13
TIMER OPERATION
NOTE:
Before setting the timer, make sure the clock is properly set with the current time.
TIMER OFF
Press the TIMER OFF ( ) button.
1
The TIMER OFF indicator will blink; press the
2
TIME ADVANCE or REVERSE buttons to set
the desired time. (The time can be set in 10minute increments.)
AM
Point the remote control at the signal receiver
3
DISPLAY
window on the unit and press the TIMER SET
(SET/C) button.
FULL
POWER
• The unit will generate a beep when it re-
• The orange TIMER lamp (
MODE
1h
1
FAN
CLEAN
SWING
SET/C
The PLASMACLUSTER and the SELF CLEAN buttons
are provided only on models AY-XPM7CR/AY-XPM9CR/
AY-XPM12CR.
TIPS ABOUT TIMER OFF OPERATION
When the TIMER OFF mode is set, the
temperature setting is automatically
adjusted to prevent the room from
becoming excessively hot or too cold
while you sleep. (Auto Sleep function)
COOL/DRY MODE:
• One hour after the time operation begins,
the temperature setting rises 1°C higher
than the original thermostat setting.
HEAT MODE:
• One hour after the timer operation begins,
the temperature setting drops 3°C lower
than the original thermostat setting.
2
3
) on the unit will
light.
ceives the signal.
TO CANCEL TIMER MODE
Press the TIMER CANCEL (SET/C) button.
• The orange TIMER lamp ( ) on the unit will
turn off.
• The current clock
time will be displayed on the remote control.
The PLASMACLUSTER and
the SELF CLEAN buttons are
provided only on models AYXPM7CR/AY-XPM9CR/AYXPM12CR.
MODE
FAN
SWING
1h
CLEAN
NOTE:
• If any TIMER ON, TIMER OFF and ONE-HOUR
OFF TIMER are set, the TIMER CANCEL
button cancels all settings.
SET/C
TO CHANGE TIME SETTING
Cancel the TIMER seting first, then set it
again.
E-14
TIMER ON
Press the TIMER ON ( ) button.
1
The TIMER ON indicator will blink; press the TIME
2
ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10-minute
AM
DISPLAY
FULL
POWER
CLEAN
1h
1
2
SET/C
3
MODE
FAN
SWING
The PLASMACLUSTER and the SELF CLEAN buttons
are provided only on models AY-XPM7CR/AY-XPM9CR/
AY-XPM12CR.
increments.)
Point the remote control at the signal receiver
3
window on the unit and press the TIMER SET
(SET/C) button.
• The orange TIMER lamp (
light.
• The unit will generate a beep when it receives
the signal.
Select the operation condition.
4
• The unit will turn on prior to the set time to allow
the room to reach the desired temperature by
the programmed time. (Awaking function)
• If unit(s) is/are operated in one mode while
TIMER ON is set with another unit in different
mode, the timer may not activate the required
operation.
ENGLISH
) on the unit will
COMBINED USE OF ON AND OFF TIMERS
You can use the ON and OFF timers in combination.
Example:
To stop operation at 11:00 p.m. and resume operation (With the same mode and temperature settings)
to bring the room temperature to the desired level by
7:00 a.m.
AM
PM
Set the TIMER OFF to 11:00 p.m. during opera-
1
tion.
Set the TIMER ON to 7:00 a.m.
2
The arrow (
indicator and the TIMER OFF indicator shows which
timer will activate first.
or ) between the TIMER ON
NOTES:
• You cannot programme the ON-TIMER and OFF-TIMER to operate the unit at
different temperatures or other settings.
• Either timer can be programmed to activate prior the other.
E-15
TIPS ABOUT PLASMACLUSTER OPERATION
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
The ionizer inside the air conditioner will release cluster ions, which are
collective mass of positive and negative ions, into the room.
The cluster ions reduce airborne mold fungus and deodorize/decompose odorcausing molecules.
Ionizer
Mold fungus
Odor
Cluster ions
AIR CLEAN OPERATION
Cluster ions released into the air will reduce airborne mold fungus and deodorize/decompose
odor-causing molecules.
REFRESHING OPERATION
It is said that plenty of negative ions exist in places such as waterfalls or forests in natural
environment. In this operation mode, negative inos will be released in an increased rate, in order
to bring the room air close to this condition.
PLASMACLUSTER AUTO OPERA TION
Dust sensor and odor sensor will detect foul air in the room.
Air Clean Operation will be performed for one minute after the air conditioner is operated to
detect foul air.
Air Clean Operation and Refreshing Operation will be selected and be performed automatically
depending on the air foul degree.
Air Clean Operation will be performed when the air is detected to be foul, Refreshing Operation
will be performed when the air is clean.
SELF CLEAN OPERATION
Plasmacluster Operation will be performed with FAN or HEAT mode, in order to reduce the
growth of mold fungus, and dry inside of the air conditioner unit.
Utilize the operation at seasonal change over terms.
Mold fungus already grown can not be eliminated by this operation.
TIPS ABOUT DUST SENSOR AND ODOR SENSOR
What does Dust Sensor react to?
• Dust sensor reacts to mold fungus, plants/flowers pollen, dead ticks, dust, tobacco smoke etc.
What does Odor Sensor react to?
• Odor Sensor reacts to tobacco smoke, motor exhaust, odor emitted from animals, etc.
Dust and Odor Sensor also may react to vapour of insecticides, cosmetics, alcohol, chemicals
and the like, and to extreme change of temperature/humidity.
E-16
PLASMACLUSTER OPERATION
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
You can choose PLASMACLUSTER AUTO OPERATION, AIR CLEAN OPERATION or
REFRESHING OPERATION
When the unit is in operation, press the
1
PLASMACLUSTER button to select the mode.
PLASMACLUSTER AUTOAIR CLEANREFRESHINGCANCEL
AUTO
AM
• In the AIR CLEAN operation, the blue
PLASMACLUSTER lamp on the unit will light up.
MODE
1h
• In the REFRESHING operation, the green
PLASMACLUSTER lamp on the unit will light up.
ENGLISH
FAN
SWING
CLEAN
1
SET/C
TO CANCEL
Press the PLASMACLUSTER button until
PLASMACLUSTER symbol on the remote control
display goes off.
• The PLASMACLUSTER lamp on the unit will turn off.
NOTES:
• Setting of the PLASMACLUSTER operation will be memorized and will operate in the same
mode, the next time you turn on the air conditioner.
• To turn off the PLASMACLUSTER lamp, press the DISPLAY button.
• When the PLASMACLUSTER button is pressed while the unit is not operating, the
PLASMACLUSTER operation will be performed without accompanying air conditioning mode
(eg. HEATING or COOLING).The mode symbol of the remote control will go off and the fan
speed can not be set AUTO. At this time, you may feel HEATING is performed with units in other
rooms. Indoor fan will decrease its rotating speed and will ture ON and OFF depending on the
room temperature.
SELF CLEAN OPERATION
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Press the SELF CLEAN button when the unit is not
1
operating.
• The remote control displays " ".
• The red OPERATION lamp ( ) and the blue
AM
PLASMACLUSTER lamp on the unit will light up.
• The unit will stop operation after forty minutes.
• The remaining operation time will be indicated on the
TEMPERATURE INDICATOR of the indoor unit in
minute decrements.
FAN
SWING
CLEAN
SET/C
1
NOTE:
• You cannot set the temperature, fan speed, air flow direction or timer setting during the SELF
CLEAN operation.
TO CANCEL
Press the SELF CLEAN button.
Or, turn the unit off by pressing the ON/OFF button.
• The red OPERATION lamp ( ),the blue
PLASMACLUSTER lamp and the TEMPERATURE
INDICATOR on the unit will turn off.
E-17
AUXILIARY MODE
Use this mode when the remote control is not available.
TO TURN ON
Lift the front panel of the indoor unit and press the
AUX. button on the operation panel.
• The red OPERATION lamp (
light and the unit will start operating in the AUTO
mode.
• The fan speed and temperature setting are set
to AUTO.
TO TURN OFF
) on the unit will
Press the AUX. button on the operation panel
again.
• The red OPERATION lamp (
turn off.
) on the unit will
NOTE:
If the AUX. button is pressed during normal operation, the unit will turn off.
OPTION KIT
(only for models AY-XM7CR/AY-XM9CR/AY-XM12CR)
Air Purifying Filter
During operation of the air conditioner, the air
purifying filter removes dust and tobacco smoke
from the air and discharges clean air.
The apatite antibacterial material used in the air
purifying filter suppresses activities of adsorbed
viruses and other germs.
The replacement period for the disposable type is
approximately 3~6 months.
Contact your dealer for the purchase of this option.
AUX.
Type AZ-F900B
E-18
MAINTENANCE
Be sure to turn off the air conditioner and turn off the circuit breaker before performing any maintenance.
(for models AY-XM7CR/AY-XM9CR/AY-XM12CR)
CLEANING THE FILTERS
1
2
1
2
3
3
3
4
2
1
The air filters should be cleaned every two weeks.
TURN OFF THE UNIT
REMOVE THE FILTERS
1 Lift the open panel.
2 Push the air filters up slightly to unlock them.
3 Pull the air filters down to remove them.
ENGLISH
CLEAN THE FILTERS
Use a vacuum cleaner to remove dust. If the
filters are dirty, wash them with warm water
and a mild detergent. Dry filters in the shade
before reinstalling.
REINSTALL THE FILTERS
1 Reinstall the filters in the original positions.
2 Close the front panel.
3 Push the arrow-marked of the panel firmly
to lock it in place.
CLEANING THE UNIT AND THE REMOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them. We can cause electrical shock or
equipment damage.
• Do not use hot water, thinner, abrasive powders or strong solvents.
MAINTENANCE AFTER AIR
CONDITIONER SEASON
Operate the unit in the COOL
1
mode, temperature setting 32°C,
for about half a day to allow the
mechanism to thoroughly dry.
Stop the operation.
2
Turn off the circuit breaker, if you
have one exclusively for the air
conditioner.
Clean the filters, then reinstall
3
them.
MAINTENANCE BEFORE
AIR CONDITIONER SEASON
Make sure that the air filters are
1
not dirty.
Make sure that nothing obstructs
2
the air inlet or outlet.
Check the outdoor mounting rack
3
periodically for wear and to make
sure it is firmly in place.
E-19
MAINTENANCE
Be sure to turn off the air conditioner and turn off the circuit breaker before performing any maintenance.
(for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
CLEANING THE FILTERS
1
2
1
2
3
3
4
3
5
2
1
6
The air filters should be cleaned every two weeks.
TURN OFF THE UNIT
REMOVE THE FILTERS
1 Lift the open panel.
2 Push the air filters up slightly to unlock them.
3 Pull the air filters down to remove them.
TAKE OFF THE DEODORANT FILTER AND
THE DUST COLLECTION FILTER FROM
THE AIR FILTERS
CLEAN THE FILTERS
Use a vacuum cleaner to remove dust. If the
filters are dirty, wash them with warm water
and a mild detergent. Dry filters in the shade
before reinstalling.
REINSTALL THE DEODORANT FILTER AND
THE DUST COLLECTION FILTER
REINSTALL THE FILTERS
1 Reinstall the filters in the original positions.
2 Close the front panel.
3 Push the arrow-marked of the panel firmly
to lock it in place.
CLEANING THE UNIT AND THE REMOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them. We can cause electrical shock or
equipment damage.
• Do not use hot water, thinner, abrasive powders or strong solvents.
MAINTENANCE AFTER AIR
CONDITIONER SEASON
Operate the unit in the SELF
1
CLEAN OPERATION to allow the
mechanism to thoroughly dry.
Stop the operation.
2
Turn off the circuit breaker, if you
have one exclusively for the air
conditioner.
Clean the filters, then reinstall
3
them.
E-20
MAINTENANCE BEFORE
AIR CONDITIONER SEASON
Make sure that the air filters are
1
not dirty.
Make sure that nothing obstructs
2
the air inlet or outlet.
Check the outdoor mounting rack
3
periodically for wear and to make
sure it is firmly in place.
CLEANING THE DEODORANT FILTER (GREEN)
The filter should be cleaned every 3~6 months
REMOVE THE AIR FILTERS
1
CLEAN THE DEODORANT FILTER
2
1 Take off the deodorant filter from the air
filters.
2 Soak the deodorant filter in mild detergent
dilution for 10 to 20 minutes.
Filter stopper
NOTE:
• Replacement is necessary at the interval of 3 years, as the deodorising effect will
deteriorate.
The new filters are available at your nearest dealer.
Replacement filter: Type AZ-F910C
Rinse thoroughly with water, dry completely
under sunlight.
3 Set the clean deodorant filter under the fil-
ter stoppers located on the air filters.
REINSTALL THE AIR FILTERS
3
ENGLISH
CHANGING THE DUST COLLECTION FILTER (GRAY)
The filter should be changed every 3~6 months
REMOVE THE AIR FILTERS
Filter stopper
NOTE:
• The dirty dust collection filter is not washable for reuse.
The new filters are available at your nearest dealer.
Replacement filter: Type AZ-F900C
1
CHANGE THE DUST COLLECTION FILTER
2
1 Take off the old dust collection filter from
the air filters.
2 Set the new dust collection filter, the black
side facing upward, under the filter stoppers located on the air filters.
REINSTALL THE AIR FILTERS
3
E-21
BEFORE CALLING FOR SERVICE
The following conditions do not denote equipment malfunctions
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on
immediately after it is turned off. The unit will not
operate immediately after the mode is changed.
This is to protect the internal mechanisms. Wait
3 minutes before operating the unit.
UNIT DOES NOT SEND OUT WARM AIR
The unit is preheating or de-icing.
ODORS
Carpet and furniture odors that entered into the
unit and the air conditioner's inner component
odors at the early stage of installation may be
sent out from the unit.
CRACKING NOISE
The unit may produce a cracking noise. This
sound is generated by the friction of the front
panel and other components expanding or
connecting due to a temperature change.
SWISHING NOISE
The soft, swishing noise is the sound of the
refrigerant flowing inside the unit.
INDOOR UNIT BECOMES WARM EVEN
WHEN IDLE
This is because the refrigerant also flows
through the idle indoor unit's pipes when the
other unit is operated in HEAT mode.
WATER VAPOUR
• In the COOL and DRY operation, water
vapour can sometimes be seen at the air
outlet due to the difference between the
room air temperature and the air discharged by the unit.
• In the HEAT operation, water vapour may
flow out of the outdoor unit during de-icing.
THE OUTDOOR UNIT DOES NOT STOP
After stopping the operation, the outdoor unit
will rotate its' fan for about a minute to cool
down the unit.
UNIT DOES NOT OPERATE IN YOUR
REQUESTED MODE
• When one indoor unit is operating in COOL
or DRY mode, you can not operate the
other unit in HEAT mode. (4 seconds later,
a long BEEP will be emitted, and the
temperature indicator on the indicator panel
will indicate " " and the OPERATION lamp
and TIMER lamp will blink alternately.)
• When one indoor unit is operating in HEAT
mode, you can not operate the other unit
in COOL nor DRY mode. (4 seconds later,
a long BEEP will be emitted, and the
temperature indicator on the indicator panel
will indicate " " and the OPERATION lamp
and TIMER lamp will blink alternately.)
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
ODOR EMITTED FROM THE
PLASMACLUSTER AIR OUTLET
This is the smell of ozone generated from the
ionizer. Density of the ozone is very little, having
no adverse effect over your health. The ozone
released into the air will decompose soon, and its
density in the room will not increase.
INDOOR UNIT BECOMES WARM EVEN
WHEN NOT DURING HEATING
A LOW BUZZ NOISE EMITTED
This is a sound emitted when the unit is
generating cluster ions.
UNIT DOES NOT SEND OUT AIR
(PLASMACLUTER operation without
accompanying air conditioning mode,
SELF CLEAN operation)
• The other unit(s) is/are de-icing.
OPERATION
When the PLASMACLUSTER button is pressed
while the unit is not operating, the
PLASMACLUSTER operation will be performed
without accompanying air conditioning mode (eg.
HEATING or COOLING) . At this time, you may feel
warm air coming out from the unit air outlet if
HEATING is performed with units in other rooms.
Indoor fan will decrease its rotating speed and will
turn ON and OFF depending on the room
temperature.
During PLASMACLUSTER AUTO
OPERATION, the air conditioner
operates in the REFRESHING OPERATION even when there is odor in the
room.
• In case for example, when the room is
full of tobacco smokes before the air
conditioner is turned on, the ODOR
SENSOR may become unreactive.
E-22
If the unit appears to be malfunctioning, check the following points before calling for
service.
IF THE UNIT FAILS TO OPERATE
Check to see if the circuit breaker has tripped or the fuse has blown.
IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY
Check the filters. If dirty,
clean them.
Make sure windows and
doors are closed tightly.
Check the outdoor unit to
make sure nothing is blocking
the air inlet or outlet.
A large number of people in
the room can prevent the unit
from achieving the desired
temperature.
Check the thermostat is
proper setting.
Check whether any heatgenerating appliances are
operating in the room.
IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
Check whether the remote
control batteries have become old and weak.
Please call for service when OPERATION Lamp, TIMER Lamp and TEMPERATURE INDICATOR
on the indicator panel blink.
Try to send the signal again
with the remote control pointed
properly towards the unit’s signal receiver window.
Check whether the remote
control batteries are installed with the polarities
properly aligned.
ENGLISH
E-23
DEUTSCH
Vielen Dank für den Kauf dieses SHARP-Klimagerätes. Bitte lesen Sie sich diese
Bedienungsanleitung sorgfältig durch, bevor Sie das Erzeugnis betreiben.
INHALT
• VORSICHTSMASSNAHMEN ......................D-1
• ZUSÄTZLICHE ANMERKUNGEN
ZUM BETRIEB.............................................D-3
Ziehen Sie nicht am Netzkabel und deformieren Sie es nicht. Das Ziehen am Netzkabel
1
sowie dessen Missbrauch kann zu einer Beschädigung des Gerätes führen und einen
elektrischen Schlag verursachen.
Zur Vermeidung von Gesundheitsschäden sollten Sie Ihren Körper nicht über einen
2
längeren Zeitraum hinweg dem kalten Luftstrom aussetzen. Dies könnte Ihren
Gesundheitszustand beeinträchtigen.
Bei der Benutzung des Klimageräts für Säuglinge, Kinder, ältere, bettlägerige oder
3
behinderte Personen ist unbedingt sicherzustellen, dass die Raumtemperatur für die
sich im Raum befindlichen Personen angemessen ist.
Stecken Sie keinerlei Gegenstände in das Gerät hinein. Dies könnte aufgrund der
4
Hochgeschwindigkeitslüfter Verletzungen verursachen.
Das Klimagerät muss auf jeden Fall geerdet werden. Schließen Sie den Erdungsdraht
5
nicht an Gas- oder Wasserleitungen, an Blitzableitern oder Telefonerdkabeln an. Eine
unvollständige Erdung könnte einen elektrischen Schlag verursachen.
Wenn beim Klimagerät irgendwelche Unregelmäßigkeiten auftreten (z.B. Brandgeruch),
6
muss der Betrieb sofort beendet und der Leistungsschalter auf OFF gestellt werden.
Halten Sie sich bei der Verlegung des Netzkabels an die örtlichen Vorschriften und
7
Bestimmungen. Ein falscher Kabelanschluss kann eine Überhitzung des Netzkabels,
des Netzsteckers oder der Steckdose und damit einen Brand verursachen.
Tauschen Sie das Netzkabel ausschließlich gegen den vom Hersteller angegebenen
8
Netzkabeltyp aus. Der Austausch sollte ausschließlich einem qualifizierten Techniker
oder dem Kundendienst vorbehalten bleiben.
DEUTSCH
SICHERHEITSHINWEISE ZUR INSTALLATION/ZUM
AUSBAU/ZUR REPARATUR
• Versuchen Sie nicht, das Gerät selbst zu installieren/auszubauen/zu reparieren. Falsch ausgeführte
Arbeiten verursachen elektrische Schläge, Wasserleck, Feuer usw.. Wenden Sie sich für
Installations-/Ausbau-/Reparaturarbeiten an Ihren Händler oder an einen qualifizierten
Kundendienst.
Dieses Gerät erfüllt die Vorschriften der EG-Richtlinien 89/336/EEC und 73/23/EEC in
der geänderten Fassung 93/68/EEC.
D-1
VORSICHTSMASSNAHMEN
SICHERHEITSHINWEISE ZUM BETRIEB
Öffnen Sie regelmäßig ein Fenster oder eine Tür, um den Raum zu lüften, besonders
1
dann, wenn Sie mit Gas betriebene Geräte benutzen. Eine unzureichende Belüftung
kann einen Sauerstoffmangel verursachen.
Die Tasten nicht mit nassen Händen bedienen. Dies könnte einen elektrischen Schlag
2
verursachen.
Aus Sicherheitsgründen sollte der Leistungsschalter ausgeschaltet sein, wenn das
3
Gerät über einen längeren Zeitraum nicht benutzt wird.
Überprüfen Sie den Montagerahmen für das Außengerät regelmäßig auf Verschleiß und
4
richtigen, festen Sitz.
Legen Sie keinerlei Gegenstände auf das Außengerät und betreten Sie es nicht. Der
5
Gegenstand oder die Person könnten in das Gerät hinein- bzw. hinunterfallen; dadurch
könnten Beschädigungen bzw. Verletzungen verursacht werden.
Dieses Gerät wurde ausschließlich für den Hausgebrauch hergestellt und darf nicht für
6
Einrichtungen wie zum Beispiel eine Hundehütte oder ein Gewächshaus zur Aufzucht
von Tieren oder Pflanzen verwendet werden.
Stellen Sie keinen mit Wasser gefüllten Behälter auf das Gerät. Beim Eintreten von
7
Wasser in das Gerät könnten die elektrischen Isolierungen Schaden nehmen und einen
elektrischen Schlag verursachen.
Blockieren Sie weder die Lufteinlass- noch Luftauslassöffnungen des Gerätes. Dies
8
könnte einen erheblichen Leistungsabfall des Gerätes sowie Störungen zur Folge
haben.
Vor der Durchführung von Wartungs- oder Reinigungsarbeiten muss in jedem Fall der
9
Betrieb gestoppt und der Leistungsschalter ausgeschaltet werden. Da im Inneren des
Gerätes ein Lüfter läuft, könnten Sie sich ansonsten Verletzungen zuziehen.
Verspritzen bzw. verschütten Sie kein Wasser direkt über dem Gerät. Wasser kann
10
sowohl einen elektrischen Schlag als auch eine Beschädigung des Gerätes verursachen.
Dieses Gerät ist nicht für die unbeaufsichtigte Benutzung durch Kleinkinder oder hilflose
11
Personen ausgelegt.
Kleinkinder sollten beaufsichtigt werden, um auszuschließen, dass sie dieses Gerät als
Spielzeug benutzen.
VORSICHTSMASSNAHMEN ZUR AUFSTELLUNG/
INSTALLATION
• Schließen Sie die Klimaanlage unbedingt an ein Netz mit der angegebenen Spannung
und Frequenz an.
Der Anschluss an ein Netz mit der falschen Voltzahl und Frequenz kann zu einer
Beschädigung des Gerätes führen und möglicherweise sogar einen Brand verursachen.
• Installieren Sie das Gerät nicht an einem Ort, an dem möglicherweise Gas ausläuft. Dies
könnte einen Brand verursachen.
Installieren Sie das Gerät an einem Ort, an dem in der Luft nur geringe Mengen an Staub,
Rauch und Feuchtigkeit vorhanden sind.
• Verlegen Sie den Ablaufschlauch gerade, um einen sanften Ablauf sicherzustellen. Ein
unzureichender Ablauf kann den Raum, die Möbel usw. feucht werden lassen.
• Stellen Sie abhängig vom Aufstellungsort sicher, dass ein Kriechstromschutz oder
Leistungsschalter installiert ist, um einen elektrischen Schlag zu vermeiden.
D-2
ZUSÄTZLICHE ANMERKUNGEN ZUM BETRIEB
BETRIEBSTEMPERATUREN
INNENTEMP.AUSSENTEMP.
KÜHLEN
Obere Grenze
Untere Grenze
Obere Grenze
HEIZEN
Untere Grenze
T.T. = Trocknenthermometer F.T. = Feuchtthermometer
32˚C T.T.43˚C T.T.
23˚C F.T. -
21˚C T.T.21˚C T.T.
15˚C F.T. -
27˚C T.T.24˚C T.T.
-18˚C F.T.
20˚C T.T.-7˚C T.T.
--8˚C F.T.
BEI STROMAUSFALL
Dieses Klimagerät verfügt über eine Reservefunktion, um Einstellungen im Falle eines Stromausfalls
zu speichern.
Nach Ende des Stromausfalls startet das Gerät wieder mit den Einstellungen, die vor dem
Stromausfall aktiv waren. Einzige Ausnahme sind die Zeitschalter-Einstellungen.
Falls vor dem Stromausfall Zeitschaltereinstellungen durchgeführt worden sind, müssen diese erneut
eingestellt werden.
VORHEIZFUNKTION
Bei der Betriebsart HEIZEN startet der Innenlüfter nach dem Einschalten des Gerätes möglicherweise
erst nach zwei bis fünf Minuten, um zu verhindern, dass kalte Luft aus dem Gerät geblasen wird.
ENTEISUNGSFUNKTION
• Wenn sich während der Betriebsart HEIZEN auf dem Wärmeaustauscher im Außengerät Eis
bildet, liefert ein automatischer Enteiser ca. 5 bis 10 Minuten Wärme, um das Eis zu beseitigen.
Während der Enteisung laufen die Innen- und Außenlüfter nicht.
• Nach Beendigung der Enteisung setzt das Gerät automatisch den Betrieb im HEIZEN-Betrieb fort.
HEIZLEISTUNG
• Das Gerät ist mit einer Wärmepumpe ausgestattet, die Wärme aus der Außenluft herauszieht und
diese Wärme an den Raum abgibt. Daher hängt die Heizleistung in hohem Maß von der
Außentemperatur ab.
• Wenn die Heizleistung aufgrund geringer Außentemperaturen reduziert ist, sollten Sie ein
zusätzliches Heizgerät einsetzen.
• Es dauert eine Zeitlang, um den ganzen Raum aufzuwärmen und zu heizen, denn dieses Gerät
arbeitet nach dem Prinzip der erzwungenen Luftumwälzung.
• Eine eingebaute Schutzvorrichtung sperrt den
Gerätebetrieb, wenn der
entsprechende Temperaturbereich überschritten wird.
• Am Luftauslass kann sich
Kondenswasser bilden,
wenn das Gerät bei einer
Luftfeuchtigkeit von mehr
als 80 Prozent kontinuierlich
in der Betriebsart KÜHLEN
oder TROCKNEN läuft.
DEUTSCH
ENERGIESPARTIPPS
Bei Berücksichtigung der nachfolgend aufgeführten Tipps können Sie bei der
Benutzung der Klimaanlage auf einfache Weise Energie sparen.
STELLEN SIE DIE RICHTIGE TEMPERATUR EIN
• Wenn im KÜHLEN-Betrieb das Thermostat 1°C höher als die gewünschte Temperatur eingestellt
wird und im HEIZEN-Betrieb 2°C niedriger, können Sie ca. 10 Prozent Strom sparen.
• Wenn Sie die Temperatur beim Kühlen niedriger als erforderlich einstellen, erhöht sich der Stromverbrauch.
VERMEIDEN SIE DIREKTES SONNENLICHT UND ZUGLUFT
• Der Ausschluss von direktem Sonnenlicht während des Kühlbetriebes reduziert den Stromverbrauch.
• Schließen Sie im Kühl- und Heizbetrieb die Fenster und Türen.
STELLEN SIE DIE RICHTUNG DES LUFTSTROMS RICHTIG EIN, UM DIE
BESTMÖGLICHE LUFTZIRKULATION ZU ERREICHEN
HALTEN SIE DEN FILTER SAUBER, UM EINEN MÖGLICHST
LEISTUNGSFÄHIGEN BETRIEB SICHERZUSTELLEN
NUTZEN SIE DIE AUSSCHALTFUNKTION DES ZEITSCHALTERS VOLL AUS
TRENNEN SIE DAS NETZKABEL AB, WENN DAS GERÄT ÜBER EINEN
LÄNGEREN ZEITRAUM HINWEG NICHT BENUTZT WIRD
• Das Gerät verbraucht auch bei Nichtbenutzung eine geringe Menge Strom.
D-3
TEILEBEZEICHNUNGEN
ZIMMERGERÄT
AUSSENGERÄT
AE-XM18CR
(Bei den Modellen AY-XPM7CR, AY-XPM9CR, AY-XPM12CR)