In the interests of user-safety (Required by safety regulations in some countries ) the set should be restored to its
original condition and only parts identical to those specified should be used.
Specifications are subject to change without
prior notice.
SHARP CORPORATION
This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
27U-S600
27U-S710
IMPORTANT SERVICE SAFETY PRECAUTION
Ë
Service work should be performed only by qualified service technicians who are
thoroughly familiar with all safety checks and the servicing guidelines which follow:
WARNING
1. For continued safety, no modification of any circuit
should be attempted.
2. Disconnect AC power before servicing.
3. Semiconductor heat sinks are potential shock hazards
when the chassis is operating.
4. The chassis in this receiver has two ground systems
which are separated by insulating material. The nonisolated (hot) ground system is for the B+ voltage
regulator circuit. The isolated ground system is for
the low B+ DC voltages and the secondary circuit of
the high voltage transformer.
To prevent electrical shock use an isolation
transformer between the line cord and power
receptacle, when servicing this chassis.
CAUTION: FOR CONTINUED
PROTECTION AGAINST A
RISK OF FIRE, REPLACE
4A 125V
ONLY WITH SAME TYPE 4A125V FUSE.
SERVICING OF HIGH VOLTAGE SYSTEM
AND PICTURE TUBE
When servicing the high voltage system,
remove the static charge by connecting a
10k ohm resistor in series with an insulated
wire (such as a test probe) between the picture tube ground and the anode lead. (AC
line cord should be disconnected from AC
outlet.)
1. Picture tube in this receiver employs integral implosion
protection.
2. Replace with tube of the same type number for
continued safety .
3. Do not lift picture tube by the neck.
4. Handle the picture tube only when wearing
shatterproof goggles and after discharging the high
voltage anode completely.
X-RADIA TION AND HIGH VOLTAGE LIMITS
1. Be sure all service personnel are aware of the
procedures and instructions covering X-radiation. The
only potential source of X-ray in current solid state
TV receivers is the picture tube. However, the picture
tube does not emit measurable X-Ray radiation, if
the high voltage is as specified in the "High Voltage
Check" instructions.
It is only when high voltage is excessive that Xradiation is capable of penetrating the shell of the
picture tube including the lead in the glass material.
The important precaution is to keep the high voltage
below the maximum level specified.
2. It is essential that servicemen have available at all
times an accurate high voltage meter.
The calibration of this meter should be checked
periodically.
3. High voltage should always be kept at the rated value
−no higher. Operation at higher voltages may cause
a failure of the picture tube or high voltage circuitry
and;also, under certain conditions, may produce
radiation in exceeding of desirable levels.
4. When the high voltage regulator is operating properly
there is no possibility of an X-radiation problem. Every
time a color chassis is serviced, the brightness should
be tested while monitoring the high voltage with a
meter to be certain that the high voltage does not
exceed the specified value and that it is regulating
correctly.
5. Do not use a picture tube other than that specified or
make unrecommended circuit modifications to the
high voltage circuitry.
6. When trouble shooting and taking test measurements
on a receiver with excessive high voltage, avoid being
unnecessarily close to the receiver.
Do not operate the receiver longer than is necessary
to locate the cause of excessive voltage.
2
22
IMPORTANT SERVICE SAFETY PRECAUTION
1.5k ohm
10W
0.15µF
TEST PROBE
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
(Continued)
27U-S600
27U-S710
BEFORE RETURNING THE RECEIVER
(Fire & Shock Hazard)
Before returning the receiver to the user, perform
the following safety checks.
1. Inspect all lead dress to make certain that leads are
not pinched or that hardware is not lodged between
the chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic
control knobs, insulating materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacity networks, mechanical
insulators, etc.
3. To be sure that no shock hazard exists, check for
leakage current in the following manner.
• Plug the AC cord directly into a 120 volt AC outlet,
(Do not use an isolation transformer for this test).
• Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15µF capacitor in series with
all exposed metal cabinet parts and a known earth
ground, such as electrical conduit or electrical ground
connected to earth ground.
• Use an AC voltmeter having with 5000 ohm per volt,
or higher, sensitivity to measure the AC voltage drop
across the resistor.
• Connect the resistor connection to all exposed metal
parts having a return to the chassis (antenna, metal
cabinet, screw heads, knobs and control shafts,
escutcheon, etc.) and measure the AC voltage drop
across the resistor.
AII checks must be repeated with the AC line cord
plug connection reversed. (If necessary, a nonpolarized adapter plug must be used only for the
purpose of completing these check.)
Any current measured must not exceed 0.5 milliamp.
Any measurements not within the limits outlined
above indicate of a potential shock hazard and
corrective action must be taken before returning the
instrument to the customer.
Many electrical and mechanical parts in television
receivers have special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
components having such features are identified by "å"
and shaded areas in the Replacement Parts Lists and
Schematic Diagrams.
For continued protection, replacement parts must be
identical to those used in the original circuit. The use of
substitute replacement parts which do not have the same
safety characteristics as the factory recommended
replacement parts shown in this service manual, may
create shock, fire, X-radiation or other hazards.
3
27U-S600
27U-S710
LOCATION OF USER'S CONTROL
(27U-S600)
Front Panel
POWER
Press→ On.
Press again→ Off.
MENU
Press→ Accesses MAIN
MENU.
Press again→ Exits MAIN
MENU.
Basic Remote Control Functions
POWER
Press→ On.
Press again→ Off.
REMOTE KEYPAD
Accesses any channel from keypad.
FLASHBACK
Returns to previous channel.
PERSONAL PREFERENCE
With the Personal Pref erence buttons,
you can program your favorite
programs by using the 4 categories A,
B, C and D. The channels can be
accessed quickly by using these
buttons.
VOLUME UP/DOWN
(+) Increases sound.
(–) Decreases sound.
• In menu mode, changes or selects
the TV adjustments.
MENU
Press→ Accesses MAIN MENU.
Press again→ Exits MAIN MENU.
CATV/DVD-TV/VCR MODE
SELECT SWITCH
In TV/VCR position, sends power and
channel select commands (Channel
up/down and Random Access buttons)
to the TV and VCR control.
In CATV/DVD position, sends power
and channel select commands to a
cable TV converter and DVD control.
DVD/VCR CONTROL
SENSOR AREA FOR
REMOTE CONTROL
POWER
TV
DVD
VCR
DISPLAY
123
456
789
FLASHBACK
PERSONAL PREFERENCE
ABCD
VOL
—
MENUMUTE
REW PLAYFF
PAUSE
PIP
SWAP FREEZE MOVE SELECT
TV • CATV • VCR • DVD
0
CH
CH
STOP REC
ENTER
100
CATVTV
DVDVCR
INPUT
VOL
+
CH/SKIP
VIDEO L-AUDIO-R
IN 2
(INSIDE DOOR)
CHANNEL UP/DOWN
(') Selects next higher channel.
(") Selects next lower channel.
• Press both at the same time to
access the MAIN MENU screen.
VOLUME UP/DOWN
(+) Increases sound.
(–) Decreases sound.
Infrared T ransmitter Windo w
DISPLAY
Press→ Displa ys receiving channel for
four seconds.
Press again→ Removes display.
• Temporarily displays receiving
channel when in Closed Caption
mode.
INPUT
Press→ Switch to external video
INPUT 1 mode.
Press 2 times→ Switch to external video
INPUT 2 mode.
Press 3 times→ Switch to external video
INPUT 3 mode or COMPONENT mode.
Press 4 times→ Switch back to the
original TV mode.
ENTER
Used in some instances where a Cable
Converter Box requires an “enter”
command after selecting channels,
when using the REMOTE KEYPAD
button.
CHANNEL UP/DOWN
(') Selects next higher channel.
(") Selects next lower channel.
•
Moves the “
” mark of the MENU
»
screens.
MUTE
Press→ Mutes sound.
Press again→ Restores sound.
• CLOSED CAPTION appears when
sound is muted.
PIP FUNCTION
With the VIDEO inputs, y ou can w atch
two pictures at the same time.
Note:
• The above shaded buttons on the Remote Control glow in the dark. To use the glow-in-the-dark display on the
remote control, place it under a fluorescent light or other lighting.
• The phosphorescent material contains no radioactive or toxic material, so it is safe to use.
• The degree of illumination will vary depending on the strength of lighting used.
• The degree of illumination will decrease with time and depending on the temperature.
• The time needed to charge the phosphorescent display will vary depending on the surrounding lighting.
• Sunlight and fluorescent lighting are the most effective when charging the display.
4
LOCATION OF USER'S CONTROL
Front Panel
POWER
→
Press On.
Press again Off.
SENSOR AREA FOR
REMOTE CONTROL
MENU
Press Accesses MAIN MENU.
Press again Exits MAIN MENU.
→
→
→
Basic Remote Control Functions
(27U-S710)
VOLUME UP/DOWN
(+) Increases sound.
(–) Decreases sound.
VIDEO L-AUDIO-R
IN 2
(INSIDE DOOR)
CHANNEL UP/DOWN
(
) Selects next higher
|
channel.
|
( ) Selects next lower
channel.
•Press both at the same
time to access the MAIN
MENU screen.
27U-S600
27U-S710
POWER
Press On.
→
Press again Off.
→
ANT–A/B
REMOTE KEYPAD
Accesses any channel from keypad.
FLASHBACK
Returns to previous channel.
PERSONAL PREFERENCE
With the Personal Preference buttons,
you can program your favorite programs
by using the 4 categories A, B, C and D
The channels can be accessed quickly
by using these buttons.
VOLUME UP/DOWN
(+) Increases sound.
(–) Decreases sound.
•
In menu mode, changes or selects the
TV adjustments.
MENU
→
Press Accesses MAIN MENU.
Press again Exits MAIN MENU.
MUTE
Press Mutes sound.
Press again Restores sound.
•
CLOSED CAPTION appears when
→
→
→
sound is muted.
POWER (DVD/VCR)
→
Press On.
Press again Off.
→
DVD/VCR CONTROL
POWER
ANT–A/B
ABCD
VOL
MENU MUTE SKIP
POWER (DVD/VCR)
CH SKIP
CATV
DVDVCR
DISPLAY
FLASHBACK
0
PERSONAL PREFERENCE
CH
–
CH
VCR-CH
PLAY
L
STOP
PAUSE
PIPSELECT
SWAP
FREEZE MOVE
TV • CATV • VCR • DVD
INPUT
ENTER
100
VOL
FWDREW
Infrared Transmitter Window
CATV/DVD-TV/VCR MODE buttons
TV
Press TV/VCR, sends power and channel
select commands (Channel up/down and
Random Access buttons) to the TV and
VCR control.
Press CATV/DVD, sends power and
channel select commands to a cable TV
321
654
987
converter and DVD control.
DISPLAY
Press Displays receiving channel for
→
four seconds.
Press again Removes display.
•
Temporarily displays receiving channel
→
when in Closed Caption mode.
+
INPUT
Press Switch to external video INPUT
→
1 mode.
Press 2 times Switch to external video
→
INPUT 2 mode.
REC
Press 3 times Switch to external video
INPUT 3 mode or COMPONENT mode.
Press 4 times Switch back to the
→
→
original TV mode.
ENTER
Used in some instances where a Cable
Converter Box requires an “enter”
command after selecting channels, when
using the REMOTE KEYPAD button.
CHANNEL UP/DOWN
( ) Selects next higher channel.
|
|
( ) Selects next lower channel.
•
Moves the “
” mark of the MENU
»
screens.
PIP FUNCTION
You can watch two pictures at the same
time.
SKIP/VCR-CH
REC
Note:
• The above shaded buttons on the Remote Control glow in the dark. To use the glow-in-the-dark display on the remote
control, place it under a fluorescent light or other lighting.
• The phosphorescent material contains no radioactive or toxic material, so it is safe to use.
• The degree of illumination will vary depending on the strength of lighting used.
• The degree of illumination will decrease with time and depending on the temperature.
• The time needed to charge the phosphorescent display will vary depending on the surrounding lighting.
• Sunlight and fluorescent lighting are the most effective when charging the display.
5
27U-S600
27U-S710
INSTALLATION AND SERVICE INSTRUCTIONS
Note:(1)When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2)Before performing adjustments, the TV set must be on at least 15 minutes.
CIRCUIT PROTECTION
The receiver is protected by a 4.0A fuse (F701),
mounted on PWB-A, wired into one side of the AC
line input.
X-RADIA TION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal
deflection system, high voltage system, B+ system,
test the X-Radiation protection circuit to ascertain
proper operation as follows:
1. Apply 120V AC using a variac transformer for accurate
input voltage.
2. Allow for warm up and adjust all customer controls
for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to TP651 and make sure
that the voltmeter reads 13.2 ±0.7V.
5. Apply external 16.3V DC at TP651 by using an
external DC supply , TV must be shut off.
6. To reset the protector, unplug the AC cord and plug
the AC cord power on. Now make sure that normal
picture appears on the screen.
7. If the operation of the horizontal oscillator does not
stop in step 5, the circuit must be repaired before the
set is returned to the customer.
HIGH VOL TAGE CHECK
High voltage is not adjustable but must be checked
to verify that the receiver is operating within safe
and efficient design limitations as specified checks
should be as follows:
1. Connect an accurate high voltage meter between
ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 120V AC
line voltage, with a strong air signal or a properly tuned
in test signal.
3. Enter the service mode and select the service
adjustment "V18" and Bus data "01" (Y -mute on, CRT
Cut Off).
4. The voltage should be approximately 29.0kV (at zero
beam).
If a correct reading cannot be obtained, check circuitry
for malfunctioning components. After the voltage test,
make Y-mute off to the normal mode.
6
27U-S600
27U-S710
For adjustments of this model, the bus data is converted to various analog signals by the D/A converter
circuit.
Note: There are still a few analog adjustments in this series such as focus and master screen voltage.
Follow the steps below whenever the service adjustment is required. See "Table-B" to determine, if service adjustments are required.
1. Service mode
Before putting unit into the service mode, check that
customer adjustments are in the normal mode. Use
the reset function in the video adjustment menu to
ensure customer controls are in their proper (reset)
position.
2. Service number selection
Once in the service mode, press the Ch-up or Chdown button on the remote controller or at the set.
The service adjustment number will vary in
increments of one, from "V01" to "P08". Select the
item you wish to adjust.
3. Data number selection
Press the Vol-up or V ol-down button to adjust the data
number.
DA TA NUMBER
SERVICE ADJUSTMENT NUMBER
To enter the service mode and exit service mode.
To enter the service mode manually just press and hold
the Vol-down and Ch-up buttons at the same time, plug
the AC cord into a wall socket.
Now the TV set is switched on and enters the service
mode.
To exit the service mode, turn the television off by
pressing the power button.
CHANNEL
V01
Figure A.
55(085)
02
7
27U-S600
27U-S710
SERVICE
NUMBER
V01PICTURE030-15(00h-0Fh)
V02TINT3E0-127(00h-7Fh)
V03COLOR2D0-127(00h-7Fh)
V04SUB-COLOR100-31(00h-1Fh)Must be set to "10"
V05BRIGHT4D0-127(00h-7Fh)
V06R CUT-OFF4064-255(40h-FFh)
V07G CUT-OFF4064-255(40h-FFh)
V08B CUT-OFF4064-255(40h-FFh)
V09G DRIVE400-127(00h-7Fh)
V10B DRIVE400-127(00h-7Fh)
V11SHARP140-63(00h-3Fh)Must be set to "1E"
V12N PHASE010-3(00h-03h)Must be set to "01"
V13DC RESTORATION000-3(00h-03h)Must be set to "03"
V14BLACK STRETCH030-3(00h-03h)Must be set to "03"
V15ABL START POINT030-3(00h-03h)Must be set to "03"
V16ABL GAIN020-3(00h-03h)Must be set to "02"
V17γ POINT000-3(00h-03h)Must be set to "02"
V18Y-MUTE/V-STOP000-2"00"=Normal, "01"=No-Y, "02"=No-Y & No-Vertical
V19ENERGY SAVE280-63(00h-3Fh)Must be set to "28"
V20RTONE-GF60-255(00h-FFh)Must be set to "F6"
V21RTONE-BF60-255(00h-FFh)Must be set to "F6"
V22BTONE-G000-255(00h-FFh)Must be set to "00"
V23BTONE-B0A0-255(00h-FFh)Must be set to "0A"
V24LOW-GF70-255(00h-FFh)Must be set to "F7"
V25LOW-BE80-255(00h-FFh)Must be set to "E8"
V26ML-G000-255(00h-FFh)Must be set to "00"
V27ML-BF90-255(00h-FFh)Must be set to "F9"
V28HIGH-G030-255(00h-FFh)Must be set to "03"
V29HIGH-B060-255(00h-FFh)Must be set to "06"
V30WPS010-1Must be set to "01"
V31RGB CONTRAST200-63(00h-3Fh)Must be set to "31"
V32Y-DL020-7(00h-07h)Must be set to "02"
V33Y-DL-INPUT010-7(00h-07h)Must be set to "01"
V34VSM GAIN070-7(00h-07h)Must be set to "07"
V35N COMB010-1Must be set to "01"
V36BPF/TOF-INPUT000-1Must be set to "01"
V37CORING000-1Must be set to "00"
V38VSM PHASE000-1Must be set to "00"
V39COLOR γ000-1Must be set to "01"
V40SHARP-INPUT140-63(00h-3Fh)Must be set to "1E"
V41TINT-INPUT3E0-127(00h-7Fh)
V42PICTURE-COMPONENT030-15(00h-0Fh)
V43TINT-COMPONENT100-31(00h-1Fh)Must be set to "10"
V44COLOR-COMPONENT300-127(00h-7Fh)Must be set to "44"
V45BRIGHT-COMPONENT4A0-127(00h-7Fh)
V46R CUT OFF-COMPONENT4064-255(40h-FFh)
V47G CUT OFF-COMPONENT4064-255(40h-FFh)
V48B CUT OFF-COMPONENT4064-255(40h-FFh)
V49G DRIVE-COMPONENT400-127(00h-7Fh)
V50B DRIVR-COMPONENT400-127(00h-7Fh)
V51SHARP COMPONENT140-63(00h-3Fh)Must be set to "1E"
V52N PHASE-COMPONENT010-3(00h-03h)Must be set to "01"
V53C-TRAP000-1Must be set to "00"
V54ANT-B PICTURE030-15(00h-0Fh)
V55ANT-B TINT3E0-127(00h-7Fh)
V56ANT-B COLOR2D0-127(00h-7Fh)
V57ANT-B SHARP140-63(00h-3Fh)Must be set to "1E"
ADJUSTMENT ITEM
INITIAL VALUE
DA T A
ADJUSTMENT CONTENTS
RANGE
Only for Model 27U-S710
R01RF-AGC240-63(00h-3Fh)
R02PIF VCO coil–
R03RF-AGC REF5C0-255(00h-FFh)Must be set to "5C"
D01V POSITION000-7(00h-07h)
D02H POSITION100-31(00h-1Fh)
D03V SIZE120-63(00h-3Fh)
D04H SIZE1F0-63(00h-3Fh)Must be set to "38"
D05V-LINEARITY070-15(00h-0Fh)
D06V-S CORRECTION080-15(00h-0Fh)Must be set to "08"
Table - A
8
27U-S600
27U-S710
SERVICE
NUMBER
D07EW PARABOLA210-63(00h-3Fh)Must be set to "04"
D08EW TRAPEZIUM0E0-31(00h-1Fh)Must be set to "0E"
D09EW CORNER0C0-15(00h-0Fh)Must be set to "04"
D10AFC GAIN020-3(00h-03h)Must be set to "02"
D11V EHT070-7(00h-07h)Must be set to "07"
D12H EHT030-7(00h-07h)Must be set to "03"
EX1F AO VOLUME240-50(00h-32h)Must be set to "24"
EX2CC-POSITION210-127(00h-7Fh)
EX3INT7A0-255(00h-FFh)Must be set to "7A"
EX4A-ATT5A0-127
EX5TUNER data000-3(00h-03h)Must be to "00"
EX6SYNC SLICE LEVEL360-255(00h-FFh)Must be to "36"
OP1OPTION1F70-255(00h-FFh)Must be set to "F7"
OP2OPTION2F90-7(00h-07h)Must be set to "10" (27U-S600), "B9" (27U-S710)
OP3OPTION3FFMust be set to "0C" (27U-S600), "0E" (27U-S710)
M01INPUT LEVEL090-15(00h-0Fh)Must be set to "09"
M02MTS VCO240-63(00h-3Fh)
M03FILTER1F0-63(00h-3Fh)
M04WIDEBAND180-63(00h-3Fh)
M05SPECTRAL100-63(00h-3Fh)
M06ANT-B INPUT LEVEL090-15(00h-0Fh)
M07ANT-B WIDEBAND180-63(00h-3Fh)
M08ANT-B SPECTRAL100-63(00h-3Fh)
M09SRS LEVELFF0-255(00h-FFh)Must be set to "E0"
M10BBE LEVELFF0-255(00h-FFh)Must be set to "D9"
M11SRS & BBE LEVELFF0-255(00h-FFh)Must be set to "D0"
M12SRS & BBE OFF LEVELFF0-255(00h-FFh)Must be set to "E5"
M13SRS Effect022-3(02h-03h)Must be set to "02"
M14BBE-L Effect080-15(00h-0Fh)Must be set to "0F"
M15BBE-H Effect080-15(00h-0Fh)Must be set to "0F"
M16AGC level070-7(00h-07h)Must be set to "01"
M17BASS Offset000-31(00h-1Fh)Must be set to "10"
M18TREBLE Offset000-31(00h-1Fh)Must be set to "10"
M19BASS Offset-BBE000-31(00h-1Fh)Must be set to "11"
M20TREBLE Offset-BBE000-31(00h-1Fh)Must be set to "10"
ADJUSTMENT ITEM
INITIAL VALUE
DA T A
ADJUSTMENT CONTENTS
RANGE
Only for Model 27U-S710
P01CONTRAST-PIP320-127(00h-7Fh)
P02TINT-PIP290-63(00h-3Fh)Must be set to "29"
P03COLOR-SAT-PIP320-127(00h-7Fh)
P04Y-OFFSET -PIP090-31(00h-1Fh)Must be set to "09"
P05HXA-PIP0A0-255(00h-FFh)Must be set to "0A"
P06HADJ-PIP000-15(00h-0Fh)Must be set to "00"
P07FREE RUN-PIP0B0-15(00h-0Fh)Must be set to "0B"
P08TINT-PIP-INPUT240-63(00h-3Fh)Must be set to "24"
Table - A
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2102.
PAR T REPLACED
IC2001
IC201
~IC2102(or IC2101)
CRT
IC3001
IC1801
~ IC2102(or IC2101) is E2PROM. IC2102 is Ref. No. for Sop type and IC2101 is Ref. No. for Dip type.
NECESSARYUNNECESSARY
ADJUSTMENT
X
X
X
X
X
NOTES
X
Data is stored in IC2102.
The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01).
Holding down both the VOL-up and CH-up buttons on the TV set in the
service mode for more than 2 seconds will automatically write the above
initial values into IC2102(or IC2101). Then perform a complete adjustment.
Adjust items related to picture tube only.
Adjust items related to MTS only (M01~M20).
Adjust items related to P-IN-P only (P01~P08).
T able - B
9
27U-S600
27U-S710
SERVICE ADJUSTMENT
RF AGC Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "R01".
3. Set the data value to point where no noise or beat
appears.
4. Select another channel to confirm that no noise or
beat appears.
Note 1 : You will have to come out of the service
mode to select another channel.
Note 2 : Setting the data to "00" will produce a black
raster.
Screen Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set the data value to "00" to
set the color level to minimum. (Record original data
code under adjustment "V03" before changing) You
may skip this step, if you selected a B/W picture or
monoscope pattern.
3. Select the service adjustment "V18" and adjust the
data value to "01", this turn off the luminance signal
(Y-mute).
4. Adjust the master screen control until the raster
darkens to the point where raster is barely seen.
5. Adjust the service adjustments "V06" red, "V07" green
and "V08" blue to obtain a good grey scale with normal
whites at low brightness level.
6. Select the service adjustment "V18" and reset data
to "00". Select the service adjustment "V03" and reset
data to obtain normal color level.
7. For component input, the data value of "V46" red,
"V47" green and "V48" blue is adjusted to follow the
data value of "V06", "V07" and "V08" respectively.
8. Reset the master screen control to obtain normal
brightness range.
Sub-picture and Sub-Bright Adjustments
1. Receive the window pattern signal.
• RF INPUT (TU51)
2. Get into service adjustment data "V01" and "V05"
and set the luminance as shown in figure "A" and "B"
as below respectively .
• RF INPUT (TU52)(Only for 27U-S710)
3. Get into service adjustment data "V54" and "V58"
and set the luminance as shown in figure "A" and "B"
as below respectively .
• COMPONENT INPUT
4. Get in service adjustment data "V42" and "V45" and
set the luminance as shown in figure "A" and "B" as
below respectively .
A
B
VOL T AGE CONFIRMATION
A: 86±10cd/m
B:1.25±0.5cd/m
2
2
Tint Adjustment (27U-S600)
1. Receive a good local channel.
2. Set customer tint control to center of it's range.
3. Enter the service mode and select the service
adjustment "V02".
4. Adjust "V02" data value to obtain normal flesh tones.
5. Input the data of "V41" to minus 5 step from "V02"
data.
White Balance Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set to "00" (minimum
color)(Record original data code under adjustment
"V03" before changing). "V03" does not have to be
adjusted, if you selected a B/W picture or monoscope
pattern.
3. Alternately adjust the service adjustment data of
"V09" and "V10" until a good grey scale with normal
whites is obtained. (RF Input)
4. For component input, the data value of "V49" and
"V50" is adjusted to follow the data value of "V09"
and "V10" respectively.
5. Select the service adjustment "V03" and reset data
to obtain normal color level.
10
27U-S600
27U-S710
Sub-Tint Adjustment (27U-S710)
1. Receive the half color bar signal.
• RF INPUT (TU51)
2. Get into Y-Mute by R/C, or by setting the "V18" bus
data to "01".
3. V ary the "V02" bus data until the waveform becomes
as stated below.
LEVEL
B-AMP Base waveform in step
(TP47B)
• RF INPUT (TU52)
4. Input data of "V55" to minus 1 step from "V02" data.
• AV INPUT
5. Input data of "V41" to minus 5 step from "V02" data.
Sub-Color Adjustment (27U-S600)
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position .
3. Enter the service mode and select service adjustment
"V03".
4. Adjust "V03" data value to obtain normal color level.
Sub-Color Adjustment (27U-S710)
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position .
• RF INPUT (TU51)
3. Enter the service mode and select service adjustment
"V03".
4. Adjust "V03" data value to obtain a normal color level.
• RF INPUT (TU52)
5. Enter the service mode and select service adjustment
"V56".
6. Input the data of "V56" same as "V03" data.
Vertical Phase Adjustment
1. Enter the service mode and select the service
adjustment "D01".
2. Adjust "D01" data value so that picture is centered.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D02".
3. Adjust "D02" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "EX2".
3. A black text box appears on the screen. (see
B.
below)
Figure
4. Adjust "EX2" data value so that text box is positioned
in the center of the screen.
Other Adjustments
1. Enter the service mode.
2. Adjust the following data values as listed below.
SERVICEADJUSTDATA(Hex)
POSITIONITEM27U-S600 27U-S710
OP1OPTION1F7F7
OP2OPTION210B9
OP3OPTION30C0E
Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D03" for V-size.
3. Adjust the "D03" bus data to get the proper V -size.
4. For V-linearity adjustment, select data bus "D05" and
adjust to get the proper vertical linearity.
Note: Aging for 10 min before adjustment. After the
adjustment of V-center and V-size, readjustment for this V-line.
Figure B.
11
27U-S600
27U-S710
Ë
MTS ADJUSTMENT
MTS Level Adjustment
1. Set the sound volume above 1.
Monoral signal: 400Hz, 100% modulation
2. Confirm "M01" data is "09h".
3. Vary the "EX4" bus data until the voltage to pin (39)
of IC3001.
4. Become the value as stated below.
• Only for 27U-S710
1. Set the sound volume above 1.
2. Vary the "M06" bus data until the voltage to pin (39)
of IC3001.
3. Becomes the value as stated below.
SETTING VOLTAGE
ADJ spec : 490±10mVrms
CHK spec: 490±20mVrms
MTS VCO Adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µF, 50V) in between
positive(+) side of C3005 and ground.
4. Enter the service mode and select the service
adjustment "M02"
5. Adjust the data so that the frequency counter reads
62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of
IC3001 .
Stereo pilot signal: 9.4kHz, 600mVrms.
2. Enter the service mode and select the service
adjustment "M03".
3. Adjust the data until "OK" appears in position on the
screen. Make sure the "OK" is displayed almost at
the center of the data range.
Separation Adjustment
1. Input "SIGNAL 1" and vary the "M04" bus data to get
the minimun AC voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" and vary the "M05" bus data to get
the minimun AC voltage to pin (39) of IC3001.
SIGNAL 1:
SIGNAL 2: 3kHz, 30% modulation, Lch only, NR-ON
• Only for 27U-S710
1. Input "SIGNAL 1" and vary the “M07” bus data to get
the minimun AC voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" and very the “M08” bus data to get
the minimun AC voltage to pin (39) of IC3001.
Note: SIGNAL 1 Adj. for wideband
SIGNAL 2 Adj. for spectral
Check the output of the speaker at the maximum
volume as stated below.
Confirmation spec:
ADJ spec: above 25 dB
CHK spec: above 20 dB
300Hz, 30% modulation, Lch only, NR-ON
Ë
P-IN-P ADJUSTMENT
P-IN-P Y-LEVEL Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P01".
3. Adjust "P01" data value to obtain normal contrast
level.
P-IN-P TINT Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P02".
3. Adjust data value to "29".
P-IN-P COLOR Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position.
3. Enter the service mode and select the service
adjustment "P03".
4. Adjust "P03" data value to obtain normal color level.
P-IN-P Y-OFF SET Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P04".
3. Adjust data value to "09".
P-IN-P H-POSITION Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P05".
3. Adjust data value to "0A".
P-IN-P BURST GATE PULSE (for MAIN)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P06".
3. Adjust data value to "00".
P-IN-P FREERUN
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P07".
3. Adjust data value to "0B".
P-IN-P TINT-INPUT Adjustment
1. Receive the composite signal.
2. Enter the service mode and select the service
adjustment "P08".
3. Adjust data value to "24".
12
MODEL 27U-S600 CHASSIS LAYOUT
H
G
F
27U-S600
27U-S710
E
D
C
B
A
654321
13
27U-S600
27U-S710
MODEL 27U-S710 CHASSIS LAYOUT
H
G
F
E
D
C
B
A
654321
14
MODEL 27U-S600 BLOCK DIAGRAM
H
G
F
27U-S600
27U-S710
E
D
C
B
A
654321
15
27U-S600
27U-S710
MODEL 27U-S710 BLOCK DIAGRAM
H
G
F
E
D
C
B
A
654321
16
DESCRIPTION OF SCHEMATIC DIAGRAM
27U-S600
27U-S710
NOTES:
1. The unit of resistance "ohm" is omitted.
(K=kΩ=1000Ω, M=MΩ)
2. All resistors are 1/16 watt, unless otherwise noted.
3. All capacitors are µ F, unless otherwise noted.
(P=pF=µµF)
4. (G) indicates ±2% tolerance may be used.
5. indicates line isolated ground.
VOLTAGE MEASUREMENT CONDITIONS:
1. All DC voltages are measured with DVM connected
between points indicated and chassis ground, line
voltage set at 120V AC and all controls set for normal
picture unless otherwise indicated.
2. All voltages measured with 1000µ V B & W or Color
signal.
WAVEFORMS
WAVEFORM MEASUREMENT CONDITIONS:
1. Photographs taken on a standard gated color bar
signal, the tint setting adjusted for proper color. The
wave shapes at the red, green and blue cathodes of
the picture tube depend on the tint, color level and
picture control.
2. indicates waveform check points (See chart,
waveforms are measured from point indicated to
chassis ground.)
å
AND SHADED ( ) COMPONENTS
= SAFETY RELATED PARTS.
'
MARK= X-RAY RELATED PARTS.
This circuit diagram is a standard one, printed circuits
may be subject to change for product improvement
without prior notice.