SHARP 27US600, US710 Service Manual

27U-S600 27U-S710
SERVICE MANUAL
S52J727U-S600
COLOR TELEVISION
Chassis No. GB-1
27U-S600
27U-S71027U-S600
MODELS
In the interests of user-safety (Required by safety regulations in some countries ) the set should be restored to its original condition and only parts identical to those specified should be used.
27U-S710
CONTENTS
Page
» ELECTRICAL SPECIFICATIONS .........................................................................................................1
» IMPORTANT SERVICE SAFETY PRECAUTION .................................................................................2
» LOCATION OF USER'S CONTROL .....................................................................................................4
» INSTALLA TION AND SERVICE INSTRUCTIONS ................................................................................6
» SERVICE ADJUSTMENT ...................................................................................................................10
» CHASSIS LAYOUT .............................................................................................................................13
» BLOCK DIAGRAM ..............................................................................................................................15
» SCHEMATIC DIAGRAMS...................................................................................................................17
» PRINTED WIRING BOARD ASSEMBLIES ........................................................................................37
» REPLACEMENT PARTS LIST............................................................................................................44
» PACKING OF THE SET ......................................................................................................................59
ELECTRICAL SPECIFICATIONS
POWER INPUT..................................................... 120V AC 60 Hz
POWER RATING .................................................................. 126W
PICTURE SIZE ........................................... 2,187cm2 (339sq inch)
CONVERGENCE ............................................................. Magnetic
SWEEP DEFLECTION .................................................... Magnetic
FOCUS ............................................... Hi-Bi-Potential Electrostatic
INTERMEDIATE FREQUENCIES
Picture IF Carrier Frequency ..................................... 45.75 MHz
Sound IF Carrier Frequency...................................... 41.25 MHz
Color Sub-Carrier Frequency .................................... 42.17 MHz
(Nominal)
AUDIO POWER
OUTPUT RATING ..............3.0W + 3.0W (at 10% distortion and
Dual CH Operate)
SPEAKER
SIZE ..........................................................9 x 5 cm oval (2 pcs.)
VOICE COIL IMPEDANCE............................... 8 ohm at 400 Hz
ANTENNA INPUT IMPEDANCE
VHF/UHF.....................................................75 ohm Unbalanced
TUNING RANGES
VHF-Channels...............................................................2 thru 13
UHF-Channels ............................................................14 thru 69
CATV Channels ...........................................................1 thru 125
(EIA, Channel Plan U.S.A.)
Specifications are subject to change without prior notice.
SHARP CORPORATION
27U-S600 27U-S710
IMPORTANT SERVICE SAFETY PRECAUTION
Ë
Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the servicing guidelines which follow:
WARNING
1. For continued safety, no modification of any circuit should be attempted.
2. Disconnect AC power before servicing.
3. Semiconductor heat sinks are potential shock hazards when the chassis is operating.
4. The chassis in this receiver has two ground systems which are separated by insulating material. The non­isolated (hot) ground system is for the B+ voltage regulator circuit. The isolated ground system is for the low B+ DC voltages and the secondary circuit of the high voltage transformer. To prevent electrical shock use an isolation transformer between the line cord and power receptacle, when servicing this chassis.
CAUTION: FOR CONTINUED PROTECTION AGAINST A RISK OF FIRE, REPLACE
4A 125V
ONLY WITH SAME TYPE 4A­125V FUSE.
SERVICING OF HIGH VOLTAGE SYSTEM AND PICTURE TUBE
When servicing the high voltage system, remove the static charge by connecting a 10k ohm resistor in series with an insulated wire (such as a test probe) between the pic­ture tube ground and the anode lead. (AC line cord should be disconnected from AC outlet.)
1. Picture tube in this receiver employs integral implosion protection.
2. Replace with tube of the same type number for continued safety .
3. Do not lift picture tube by the neck.
4. Handle the picture tube only when wearing shatterproof goggles and after discharging the high voltage anode completely.
X-RADIA TION AND HIGH VOLTAGE LIMITS
1. Be sure all service personnel are aware of the procedures and instructions covering X-radiation. The only potential source of X-ray in current solid state TV receivers is the picture tube. However, the picture tube does not emit measurable X-Ray radiation, if the high voltage is as specified in the "High Voltage Check" instructions. It is only when high voltage is excessive that X­radiation is capable of penetrating the shell of the picture tube including the lead in the glass material. The important precaution is to keep the high voltage below the maximum level specified.
2. It is essential that servicemen have available at all times an accurate high voltage meter. The calibration of this meter should be checked periodically.
3. High voltage should always be kept at the rated value
no higher. Operation at higher voltages may cause a failure of the picture tube or high voltage circuitry and;also, under certain conditions, may produce radiation in exceeding of desirable levels.
4. When the high voltage regulator is operating properly there is no possibility of an X-radiation problem. Every time a color chassis is serviced, the brightness should be tested while monitoring the high voltage with a meter to be certain that the high voltage does not exceed the specified value and that it is regulating correctly.
5. Do not use a picture tube other than that specified or make unrecommended circuit modifications to the high voltage circuitry.
6. When trouble shooting and taking test measurements on a receiver with excessive high voltage, avoid being unnecessarily close to the receiver. Do not operate the receiver longer than is necessary to locate the cause of excessive voltage.
2
2 2
IMPORTANT SERVICE SAFETY PRECAUTION
1.5k ohm 10W
0.15µF
TEST PROBE
TO EXPOSED METAL PARTS
CONNECT TO KNOWN EARTH GROUND
(Continued)
27U-S600 27U-S710
BEFORE RETURNING THE RECEIVER (Fire & Shock Hazard)
Before returning the receiver to the user, perform the following safety checks.
1. Inspect all lead dress to make certain that leads are not pinched or that hardware is not lodged between the chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic control knobs, insulating materials, cabinet backs, adjustment and compartment covers or shields, isolation resistor-capacity networks, mechanical insulators, etc.
3. To be sure that no shock hazard exists, check for leakage current in the following manner.
Plug the AC cord directly into a 120 volt AC outlet, (Do not use an isolation transformer for this test).
Using two clip leads, connect a 1.5k ohm, 10 watt resistor paralleled by a 0.15µF capacitor in series with all exposed metal cabinet parts and a known earth ground, such as electrical conduit or electrical ground connected to earth ground.
Use an AC voltmeter having with 5000 ohm per volt, or higher, sensitivity to measure the AC voltage drop across the resistor.
Connect the resistor connection to all exposed metal parts having a return to the chassis (antenna, metal cabinet, screw heads, knobs and control shafts, escutcheon, etc.) and measure the AC voltage drop across the resistor. AII checks must be repeated with the AC line cord plug connection reversed. (If necessary, a non­polarized adapter plug must be used only for the purpose of completing these check.) Any current measured must not exceed 0.5 milliamp. Any measurements not within the limits outlined above indicate of a potential shock hazard and corrective action must be taken before returning the instrument to the customer.
234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121
SAFETY NOTICE
Many electrical and mechanical parts in television receivers have special safety-related characteristics. These characteristics are often not evident from visual inspection, nor can protection afforded by them be necessarily increased by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this manual; electrical components having such features are identified by "å" and shaded areas in the Replacement Parts Lists and Schematic Diagrams.
234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121
For continued protection, replacement parts must be identical to those used in the original circuit. The use of substitute replacement parts which do not have the same safety characteristics as the factory recommended replacement parts shown in this service manual, may create shock, fire, X-radiation or other hazards.
3
27U-S600 27U-S710
LOCATION OF USER'S CONTROL
(27U-S600)
Front Panel
POWER
Press On. Press again Off.
MENU
Press Accesses MAIN MENU. Press again → Exits MAIN MENU.
Basic Remote Control Functions
POWER
Press On. Press again Off.
REMOTE KEYPAD
Accesses any channel from keypad.
FLASHBACK
Returns to previous channel.
PERSONAL PREFERENCE
With the Personal Pref erence buttons, you can program your favorite programs by using the 4 categories A, B, C and D. The channels can be accessed quickly by using these buttons.
VOLUME UP/DOWN
(+) Increases sound. (–) Decreases sound.
• In menu mode, changes or selects the TV adjustments.
MENU
Press Accesses MAIN MENU. Press again Exits MAIN MENU.
CATV/DVD-TV/VCR MODE SELECT SWITCH
In TV/VCR position, sends power and channel select commands (Channel up/down and Random Access buttons) to the TV and VCR control. In CATV/DVD position, sends power and channel select commands to a cable TV converter and DVD control.
DVD/VCR CONTROL
SENSOR AREA FOR REMOTE CONTROL
POWER
TV
DVD VCR
DISPLAY
1 2 3 4 5 6 7 8 9
FLASHBACK
PERSONAL PREFERENCE
A B C D
VOL
MENU MUTE
REW PLAY FF
PAUSE
PIP
SWAP FREEZE MOVE SELECT
TV • CATV • VCR • DVD
0
CH
CH
STOP REC
ENTER
100
CATV TV
DVD VCR
INPUT
VOL
+
CH/SKIP
VIDEO L-AUDIO-R
IN 2
(INSIDE DOOR)
CHANNEL UP/DOWN
(') Selects next higher channel. (") Selects next lower channel.
• Press both at the same time to access the MAIN MENU screen.
VOLUME UP/DOWN
(+) Increases sound. (–) Decreases sound.
Infrared T ransmitter Windo w
DISPLAY
Press Displa ys receiving channel for four seconds. Press again Removes display.
• Temporarily displays receiving channel when in Closed Caption mode.
INPUT
Press Switch to external video INPUT 1 mode. Press 2 times → Switch to external video INPUT 2 mode. Press 3 times → Switch to external video INPUT 3 mode or COMPONENT mode. Press 4 times → Switch back to the original TV mode.
ENTER
Used in some instances where a Cable Converter Box requires an “enter” command after selecting channels, when using the REMOTE KEYPAD button.
CHANNEL UP/DOWN
(') Selects next higher channel. (") Selects next lower channel.
Moves the “
” mark of the MENU
»
screens.
MUTE
Press Mutes sound. Press again Restores sound.
• CLOSED CAPTION appears when sound is muted.
PIP FUNCTION
With the VIDEO inputs, y ou can w atch two pictures at the same time.
Note:
• The above shaded buttons on the Remote Control glow in the dark. To use the glow-in-the-dark display on the remote control, place it under a fluorescent light or other lighting.
• The phosphorescent material contains no radioactive or toxic material, so it is safe to use.
• The degree of illumination will vary depending on the strength of lighting used.
• The degree of illumination will decrease with time and depending on the temperature.
• The time needed to charge the phosphorescent display will vary depending on the surrounding lighting.
• Sunlight and fluorescent lighting are the most effective when charging the display.
4
LOCATION OF USER'S CONTROL
Front Panel
POWER
Press On.
Press again Off.
SENSOR AREA FOR REMOTE CONTROL
MENU
Press Accesses MAIN MENU. Press again Exits MAIN MENU.
Basic Remote Control Functions
(27U-S710)
VOLUME UP/DOWN
(+) Increases sound. (–) Decreases sound.
VIDEO L-AUDIO-R
IN 2
(INSIDE DOOR)
CHANNEL UP/DOWN (
) Selects next higher
|
channel.
|
( ) Selects next lower
channel.
Press both at the same
time to access the MAIN MENU screen.
27U-S600 27U-S710
POWER
Press On.
Press again Off.
ANT–A/B
REMOTE KEYPAD
Accesses any channel from keypad.
FLASHBACK
Returns to previous channel.
PERSONAL PREFERENCE
With the Personal Preference buttons, you can program your favorite programs by using the 4 categories A, B, C and D The channels can be accessed quickly by using these buttons.
VOLUME UP/DOWN
(+) Increases sound. (–) Decreases sound.
In menu mode, changes or selects the TV adjustments.
MENU
Press Accesses MAIN MENU. Press again Exits MAIN MENU.
MUTE
Press Mutes sound. Press again Restores sound.
CLOSED CAPTION appears when
sound is muted.
POWER (DVD/VCR)
Press On. Press again Off.
DVD/VCR CONTROL
POWER
ANT–A/B
ABCD
VOL
MENU MUTE SKIP
POWER (DVD/VCR)
CH SKIP
CATV
DVD VCR
DISPLAY
FLASHBACK
0
PERSONAL PREFERENCE
CH
CH
VCR-CH
PLAY
L
STOP
PAUSE
PIP SELECT
SWAP
FREEZE MOVE
TV CATV VCR • DVD
INPUT
ENTER
100
VOL
FWDREW
Infrared Transmitter Window
CATV/DVD-TV/VCR MODE buttons
TV
Press TV/VCR, sends power and channel select commands (Channel up/down and Random Access buttons) to the TV and VCR control. Press CATV/DVD, sends power and channel select commands to a cable TV
321 654 987
converter and DVD control.
DISPLAY
Press Displays receiving channel for
four seconds. Press again Removes display.
Temporarily displays receiving channel
when in Closed Caption mode.
+
INPUT
Press Switch to external video INPUT
1 mode. Press 2 times Switch to external video
INPUT 2 mode.
REC
Press 3 times Switch to external video INPUT 3 mode or COMPONENT mode. Press 4 times Switch back to the
original TV mode.
ENTER
Used in some instances where a Cable Converter Box requires an enter command after selecting channels, when using the REMOTE KEYPAD button.
CHANNEL UP/DOWN
( ) Selects next higher channel.
|
|
( ) Selects next lower channel.
Moves the
mark of the MENU
»
screens.
PIP FUNCTION
You can watch two pictures at the same time.
SKIP/VCR-CH
REC
Note:
The above shaded buttons on the Remote Control glow in the dark. To use the glow-in-the-dark display on the remote
control, place it under a fluorescent light or other lighting.
The phosphorescent material contains no radioactive or toxic material, so it is safe to use.
The degree of illumination will vary depending on the strength of lighting used.
The degree of illumination will decrease with time and depending on the temperature.
The time needed to charge the phosphorescent display will vary depending on the surrounding lighting.
Sunlight and fluorescent lighting are the most effective when charging the display.
5
27U-S600 27U-S710
INSTALLATION AND SERVICE INSTRUCTIONS
Note: (1)When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2)Before performing adjustments, the TV set must be on at least 15 minutes.
CIRCUIT PROTECTION
The receiver is protected by a 4.0A fuse (F701), mounted on PWB-A, wired into one side of the AC line input.
X-RADIA TION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal deflection system, high voltage system, B+ system, test the X-Radiation protection circuit to ascertain proper operation as follows:
1. Apply 120V AC using a variac transformer for accurate input voltage.
2. Allow for warm up and adjust all customer controls for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to TP651 and make sure that the voltmeter reads 13.2 ±0.7V.
5. Apply external 16.3V DC at TP651 by using an external DC supply , TV must be shut off.
6. To reset the protector, unplug the AC cord and plug the AC cord power on. Now make sure that normal picture appears on the screen.
7. If the operation of the horizontal oscillator does not stop in step 5, the circuit must be repaired before the set is returned to the customer.
HIGH VOL TAGE CHECK
High voltage is not adjustable but must be checked to verify that the receiver is operating within safe and efficient design limitations as specified checks should be as follows:
1. Connect an accurate high voltage meter between ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 120V AC line voltage, with a strong air signal or a properly tuned in test signal.
3. Enter the service mode and select the service adjustment "V18" and Bus data "01" (Y -mute on, CRT Cut Off).
4. The voltage should be approximately 29.0kV (at zero beam). If a correct reading cannot be obtained, check circuitry for malfunctioning components. After the voltage test, make Y-mute off to the normal mode.
6
27U-S600 27U-S710
For adjustments of this model, the bus data is converted to various analog signals by the D/A converter circuit.
Note: There are still a few analog adjustments in this series such as focus and master screen voltage.
Follow the steps below whenever the service adjustment is required. See "Table-B" to determine, if serv­ice adjustments are required.
1. Service mode
Before putting unit into the service mode, check that customer adjustments are in the normal mode. Use the reset function in the video adjustment menu to ensure customer controls are in their proper (reset) position.
2. Service number selection
Once in the service mode, press the Ch-up or Ch­down button on the remote controller or at the set. The service adjustment number will vary in increments of one, from "V01" to "P08". Select the item you wish to adjust.
3. Data number selection
Press the Vol-up or V ol-down button to adjust the data number.
DA TA NUMBER
SERVICE ADJUSTMENT NUMBER
To enter the service mode and exit serv­ice mode.
To enter the service mode manually just press and hold the Vol-down and Ch-up buttons at the same time, plug the AC cord into a wall socket. Now the TV set is switched on and enters the service mode. To exit the service mode, turn the television off by pressing the power button.
CHANNEL
V01
Figure A.
55(085)
02
7
27U-S600 27U-S710
SERVICE
NUMBER
V01 PICTURE 03 0-15(00h-0Fh) V02 TINT 3E 0-127(00h-7Fh) V03 COLOR 2D 0-127(00h-7Fh) V04 SUB-COLOR 10 0-31(00h-1Fh) Must be set to "10" V05 BRIGHT 4D 0-127(00h-7Fh) V06 R CUT-OFF 40 64-255(40h-FFh) V07 G CUT-OFF 40 64-255(40h-FFh) V08 B CUT-OFF 40 64-255(40h-FFh) V09 G DRIVE 40 0-127(00h-7Fh) V10 B DRIVE 40 0-127(00h-7Fh) V11 SHARP 14 0-63(00h-3Fh) Must be set to "1E" V12 N PHASE 01 0-3(00h-03h) Must be set to "01" V13 DC RESTORATION 00 0-3(00h-03h) Must be set to "03" V14 BLACK STRETCH 03 0-3(00h-03h) Must be set to "03" V15 ABL START POINT 03 0-3(00h-03h) Must be set to "03" V16 ABL GAIN 02 0-3(00h-03h) Must be set to "02" V17 γ POINT 00 0-3(00h-03h) Must be set to "02" V18 Y-MUTE/V-STOP 00 0-2 "00"=Normal, "01"=No-Y, "02"=No-Y & No-Vertical V19 ENERGY SAVE 28 0-63(00h-3Fh) Must be set to "28" V20 RTONE-G F6 0-255(00h-FFh) Must be set to "F6" V21 RTONE-B F6 0-255(00h-FFh) Must be set to "F6" V22 BTONE-G 00 0-255(00h-FFh) Must be set to "00" V23 BTONE-B 0A 0-255(00h-FFh) Must be set to "0A" V24 LOW-G F7 0-255(00h-FFh) Must be set to "F7" V25 LOW-B E8 0-255(00h-FFh) Must be set to "E8" V26 ML-G 00 0-255(00h-FFh) Must be set to "00" V27 ML-B F9 0-255(00h-FFh) Must be set to "F9" V28 HIGH-G 03 0-255(00h-FFh) Must be set to "03" V29 HIGH-B 06 0-255(00h-FFh) Must be set to "06" V30 WPS 01 0-1 Must be set to "01" V31 RGB CONTRAST 20 0-63(00h-3Fh) Must be set to "31" V32 Y-DL 02 0-7(00h-07h) Must be set to "02" V33 Y-DL-INPUT 01 0-7(00h-07h) Must be set to "01" V34 VSM GAIN 07 0-7(00h-07h) Must be set to "07" V35 N COMB 01 0-1 Must be set to "01" V36 BPF/TOF-INPUT 00 0-1 Must be set to "01" V37 CORING 00 0-1 Must be set to "00" V38 VSM PHASE 00 0-1 Must be set to "00" V39 COLOR γ 00 0-1 Must be set to "01" V40 SHARP-INPUT 14 0-63(00h-3Fh) Must be set to "1E" V41 TINT-INPUT 3E 0-127(00h-7Fh) V42 PICTURE-COMPONENT 03 0-15(00h-0Fh) V43 TINT-COMPONENT 10 0-31(00h-1Fh) Must be set to "10" V44 COLOR-COMPONENT 30 0-127(00h-7Fh) Must be set to "44" V45 BRIGHT-COMPONENT 4A 0-127(00h-7Fh) V46 R CUT OFF-COMPONENT 40 64-255(40h-FFh) V47 G CUT OFF-COMPONENT 40 64-255(40h-FFh) V48 B CUT OFF-COMPONENT 40 64-255(40h-FFh) V49 G DRIVE-COMPONENT 40 0-127(00h-7Fh) V50 B DRIVR-COMPONENT 40 0-127(00h-7Fh) V51 SHARP COMPONENT 14 0-63(00h-3Fh) Must be set to "1E" V52 N PHASE-COMPONENT 01 0-3(00h-03h) Must be set to "01" V53 C-TRAP 00 0-1 Must be set to "00" V54 ANT-B PICTURE 03 0-15(00h-0Fh) V55 ANT-B TINT 3E 0-127(00h-7Fh) V56 ANT-B COLOR 2D 0-127(00h-7Fh) V57 ANT-B SHARP 14 0-63(00h-3Fh) Must be set to "1E"
ADJUSTMENT ITEM
INITIAL VALUE
DA T A
ADJUSTMENT CONTENTS
RANGE
Only for Model 27U-S710
R01 RF-AGC 24 0-63(00h-3Fh) R02 PIF VCO coil – R03 RF-AGC REF 5C 0-255(00h-FFh) Must be set to "5C"
D01 V POSITION 00 0-7(00h-07h) D02 H POSITION 10 0-31(00h-1Fh) D03 V SIZE 12 0-63(00h-3Fh) D04 H SIZE 1F 0-63(00h-3Fh) Must be set to "38" D05 V-LINEARITY 07 0-15(00h-0Fh) D06 V-S CORRECTION 08 0-15(00h-0Fh) Must be set to "08"
Table - A
8
27U-S600 27U-S710
SERVICE
NUMBER
D07 EW PARABOLA 21 0-63(00h-3Fh) Must be set to "04" D08 EW TRAPEZIUM 0E 0-31(00h-1Fh) Must be set to "0E" D09 EW CORNER 0C 0-15(00h-0Fh) Must be set to "04" D10 AFC GAIN 02 0-3(00h-03h) Must be set to "02" D11 V EHT 07 0-7(00h-07h) Must be set to "07" D12 H EHT 03 0-7(00h-07h) Must be set to "03"
EX1 F AO VOLUME 24 0-50(00h-32h) Must be set to "24" EX2 CC-POSITION 21 0-127(00h-7Fh) EX3 INT 7A 0-255(00h-FFh) Must be set to "7A" EX4 A-ATT 5A 0-127 EX5 TUNER data 00 0-3(00h-03h) Must be to "00" EX6 SYNC SLICE LEVEL 36 0-255(00h-FFh) Must be to "36"
OP1 OPTION1 F7 0-255(00h-FFh) Must be set to "F7" OP2 OPTION2 F9 0-7(00h-07h) Must be set to "10" (27U-S600), "B9" (27U-S710) OP3 OPTION3 FF Must be set to "0C" (27U-S600), "0E" (27U-S710)
M01 INPUT LEVEL 09 0-15(00h-0Fh) Must be set to "09" M02 MTS VCO 24 0-63(00h-3Fh) M03 FILTER 1F 0-63(00h-3Fh) M04 WIDEBAND 18 0-63(00h-3Fh) M05 SPECTRAL 10 0-63(00h-3Fh) M06 ANT-B INPUT LEVEL 09 0-15(00h-0Fh) M07 ANT-B WIDEBAND 18 0-63(00h-3Fh) M08 ANT-B SPECTRAL 10 0-63(00h-3Fh) M09 SRS LEVEL FF 0-255(00h-FFh) Must be set to "E0" M10 BBE LEVEL FF 0-255(00h-FFh) Must be set to "D9" M11 SRS & BBE LEVEL FF 0-255(00h-FFh) Must be set to "D0" M12 SRS & BBE OFF LEVEL FF 0-255(00h-FFh) Must be set to "E5" M13 SRS Effect 02 2-3(02h-03h) Must be set to "02" M14 BBE-L Effect 08 0-15(00h-0Fh) Must be set to "0F" M15 BBE-H Effect 08 0-15(00h-0Fh) Must be set to "0F" M16 AGC level 07 0-7(00h-07h) Must be set to "01" M17 BASS Offset 00 0-31(00h-1Fh) Must be set to "10" M18 TREBLE Offset 00 0-31(00h-1Fh) Must be set to "10" M19 BASS Offset-BBE 00 0-31(00h-1Fh) Must be set to "11" M20 TREBLE Offset-BBE 00 0-31(00h-1Fh) Must be set to "10"
ADJUSTMENT ITEM
INITIAL VALUE
DA T A
ADJUSTMENT CONTENTS
RANGE
Only for Model 27U-S710
P01 CONTRAST-PIP 32 0-127(00h-7Fh) P02 TINT-PIP 29 0-63(00h-3Fh) Must be set to "29" P03 COLOR-SAT-PIP 32 0-127(00h-7Fh) P04 Y-OFFSET -PIP 09 0-31(00h-1Fh) Must be set to "09" P05 HXA-PIP 0A 0-255(00h-FFh) Must be set to "0A" P06 HADJ-PIP 00 0-15(00h-0Fh) Must be set to "00" P07 FREE RUN-PIP 0B 0-15(00h-0Fh) Must be set to "0B" P08 TINT-PIP-INPUT 24 0-63(00h-3Fh) Must be set to "24"
Table - A
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will automatically write the above initial values into IC2102.
PAR T REPLACED
IC2001 IC201
~IC2102(or IC2101)
CRT IC3001
IC1801
~ IC2102(or IC2101) is E2PROM. IC2102 is Ref. No. for Sop type and IC2101 is Ref. No. for Dip type.
NECESSARY UNNECESSARY
ADJUSTMENT
X
X
X X X
NOTES
X
Data is stored in IC2102. The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01). Holding down both the VOL-up and CH-up buttons on the TV set in the
service mode for more than 2 seconds will automatically write the above initial values into IC2102(or IC2101). Then perform a complete adjustment.
Adjust items related to picture tube only. Adjust items related to MTS only (M01~M20).
Adjust items related to P-IN-P only (P01~P08).
T able - B
9
27U-S600 27U-S710
SERVICE ADJUSTMENT
RF AGC Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "R01".
3. Set the data value to point where no noise or beat appears.
4. Select another channel to confirm that no noise or beat appears. Note 1 : You will have to come out of the service
mode to select another channel.
Note 2 : Setting the data to "00" will produce a black
raster.
Screen Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "V03" and set the data value to "00" to set the color level to minimum. (Record original data code under adjustment "V03" before changing) You may skip this step, if you selected a B/W picture or monoscope pattern.
3. Select the service adjustment "V18" and adjust the data value to "01", this turn off the luminance signal (Y-mute).
4. Adjust the master screen control until the raster darkens to the point where raster is barely seen.
5. Adjust the service adjustments "V06" red, "V07" green and "V08" blue to obtain a good grey scale with normal whites at low brightness level.
6. Select the service adjustment "V18" and reset data to "00". Select the service adjustment "V03" and reset data to obtain normal color level.
7. For component input, the data value of "V46" red, "V47" green and "V48" blue is adjusted to follow the data value of "V06", "V07" and "V08" respectively.
8. Reset the master screen control to obtain normal brightness range.
Sub-picture and Sub-Bright Adjustments
1. Receive the window pattern signal.
RF INPUT (TU51)
2. Get into service adjustment data "V01" and "V05" and set the luminance as shown in figure "A" and "B" as below respectively .
RF INPUT (TU52)(Only for 27U-S710)
3. Get into service adjustment data "V54" and "V58" and set the luminance as shown in figure "A" and "B" as below respectively .
COMPONENT INPUT
4. Get in service adjustment data "V42" and "V45" and set the luminance as shown in figure "A" and "B" as below respectively .
A
B
VOL T AGE CONFIRMATION
A: 86±10cd/m B:1.25±0.5cd/m
2
2
Tint Adjustment (27U-S600)
1. Receive a good local channel.
2. Set customer tint control to center of it's range.
3. Enter the service mode and select the service adjustment "V02".
4. Adjust "V02" data value to obtain normal flesh tones.
5. Input the data of "V41" to minus 5 step from "V02" data.
White Balance Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "V03" and set to "00" (minimum color)(Record original data code under adjustment "V03" before changing). "V03" does not have to be adjusted, if you selected a B/W picture or monoscope pattern.
3. Alternately adjust the service adjustment data of "V09" and "V10" until a good grey scale with normal whites is obtained. (RF Input)
4. For component input, the data value of "V49" and "V50" is adjusted to follow the data value of "V09" and "V10" respectively.
5. Select the service adjustment "V03" and reset data to obtain normal color level.
10
27U-S600 27U-S710
Sub-Tint Adjustment (27U-S710)
1. Receive the half color bar signal.
RF INPUT (TU51)
2. Get into Y-Mute by R/C, or by setting the "V18" bus data to "01".
3. V ary the "V02" bus data until the waveform becomes as stated below.
LEVEL
B-AMP Base waveform in step (TP47B)
RF INPUT (TU52)
4. Input data of "V55" to minus 1 step from "V02" data.
AV INPUT
5. Input data of "V41" to minus 5 step from "V02" data.
Sub-Color Adjustment (27U-S600)
1. Receive a good local channel.
2. Make sure the customer color control is set to center position .
3. Enter the service mode and select service adjustment "V03".
4. Adjust "V03" data value to obtain normal color level.
Sub-Color Adjustment (27U-S710)
1. Receive a good local channel.
2. Make sure the customer color control is set to center position .
RF INPUT (TU51)
3. Enter the service mode and select service adjustment "V03".
4. Adjust "V03" data value to obtain a normal color level.
RF INPUT (TU52)
5. Enter the service mode and select service adjustment "V56".
6. Input the data of "V56" same as "V03" data.
Vertical Phase Adjustment
1. Enter the service mode and select the service adjustment "D01".
2. Adjust "D01" data value so that picture is centered.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "D02".
3. Adjust "D02" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "EX2".
3. A black text box appears on the screen. (see
B.
below)
Figure
4. Adjust "EX2" data value so that text box is positioned in the center of the screen.
Other Adjustments
1. Enter the service mode.
2. Adjust the following data values as listed below.
SERVICE ADJUST DATA(Hex)
POSITION ITEM 27U-S600 27U-S710
OP1 OPTION1 F7 F7 OP2 OPTION2 10 B9 OP3 OPTION3 0C 0E
Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "D03" for V-size.
3. Adjust the "D03" bus data to get the proper V -size.
4. For V-linearity adjustment, select data bus "D05" and adjust to get the proper vertical linearity. Note: Aging for 10 min before adjustment. After the
adjustment of V-center and V-size, re­adjustment for this V-line.
Figure B.
11
27U-S600 27U-S710
Ë
MTS ADJUSTMENT
MTS Level Adjustment
1. Set the sound volume above 1. Monoral signal: 400Hz, 100% modulation
2. Confirm "M01" data is "09h".
3. Vary the "EX4" bus data until the voltage to pin (39) of IC3001.
4. Become the value as stated below.
Only for 27U-S710
1. Set the sound volume above 1.
2. Vary the "M06" bus data until the voltage to pin (39) of IC3001.
3. Becomes the value as stated below. SETTING VOLTAGE
ADJ spec : 490±10mVrms CHK spec: 490±20mVrms
MTS VCO Adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µF, 50V) in between positive(+) side of C3005 and ground.
4. Enter the service mode and select the service adjustment "M02"
5. Adjust the data so that the frequency counter reads
62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of IC3001 . Stereo pilot signal: 9.4kHz, 600mVrms.
2. Enter the service mode and select the service adjustment "M03".
3. Adjust the data until "OK" appears in position on the screen. Make sure the "OK" is displayed almost at the center of the data range.
Separation Adjustment
1. Input "SIGNAL 1" and vary the "M04" bus data to get the minimun AC voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" and vary the "M05" bus data to get the minimun AC voltage to pin (39) of IC3001. SIGNAL 1: SIGNAL 2: 3kHz, 30% modulation, Lch only, NR-ON
Only for 27U-S710
1. Input "SIGNAL 1" and vary the M07 bus data to get the minimun AC voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" and very the M08 bus data to get the minimun AC voltage to pin (39) of IC3001.
Note: SIGNAL 1 Adj. for wideband
SIGNAL 2 Adj. for spectral Check the output of the speaker at the maximum volume as stated below. Confirmation spec:
ADJ spec: above 25 dB
CHK spec: above 20 dB
300Hz, 30% modulation, Lch only, NR-ON
Ë
P-IN-P ADJUSTMENT
P-IN-P Y-LEVEL Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P01".
3. Adjust "P01" data value to obtain normal contrast level.
P-IN-P TINT Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P02".
3. Adjust data value to "29".
P-IN-P COLOR Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center position.
3. Enter the service mode and select the service adjustment "P03".
4. Adjust "P03" data value to obtain normal color level.
P-IN-P Y-OFF SET Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P04".
3. Adjust data value to "09".
P-IN-P H-POSITION Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P05".
3. Adjust data value to "0A".
P-IN-P BURST GATE PULSE (for MAIN)
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P06".
3. Adjust data value to "00".
P-IN-P FREERUN
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P07".
3. Adjust data value to "0B".
P-IN-P TINT-INPUT Adjustment
1. Receive the composite signal.
2. Enter the service mode and select the service adjustment "P08".
3. Adjust data value to "24".
12
MODEL 27U-S600 CHASSIS LAYOUT
H
G
F
27U-S600 27U-S710
E
D
C
B
A
654321
13
27U-S600 27U-S710
MODEL 27U-S710 CHASSIS LAYOUT
H
G
F
E
D
C
B
A
654321
14
MODEL 27U-S600 BLOCK DIAGRAM
H
G
F
27U-S600 27U-S710
E
D
C
B
A
654321
15
27U-S600 27U-S710
MODEL 27U-S710 BLOCK DIAGRAM
H
G
F
E
D
C
B
A
654321
16
DESCRIPTION OF SCHEMATIC DIAGRAM
27U-S600 27U-S710
NOTES:
1. The unit of resistance "ohm" is omitted. (K=kΩ=1000Ω, M=MΩ)
2. All resistors are 1/16 watt, unless otherwise noted.
3. All capacitors are µ F, unless otherwise noted. (P=pF=µµF)
4. (G) indicates ±2% tolerance may be used.
5. indicates line isolated ground.
VOLTAGE MEASUREMENT CONDITIONS:
1. All DC voltages are measured with DVM connected between points indicated and chassis ground, line voltage set at 120V AC and all controls set for normal picture unless otherwise indicated.
2. All voltages measured with 1000µ V B & W or Color signal.
WAVEFORMS
WAVEFORM MEASUREMENT CONDITIONS:
1. Photographs taken on a standard gated color bar signal, the tint setting adjusted for proper color. The wave shapes at the red, green and blue cathodes of the picture tube depend on the tint, color level and picture control.
2. indicates waveform check points (See chart, waveforms are measured from point indicated to chassis ground.)
å
AND SHADED ( ) COMPONENTS
= SAFETY RELATED PARTS.
'
MARK= X-RAY RELATED PARTS.
This circuit diagram is a standard one, printed circuits may be subject to change for product improvement without prior notice.
1 1.2 Vp-p 2 2.3 Vp-p 3 1.0 Vp-p 4 0.5 Vp-p 5 5 Vp-p 6 5 Vp-p
7 1.1 Vp-p 8 1.5 Vp-p 9 30 Vp-p 0 53 Vp-p q 5.4 Vp-p w 0.8 Vp-p
e 190 Vp-p r 15 Vp-p t 1050 Vp-p y 900 Vp-p u 220 Vp-p i 27 Vp-p
o 3.0 Vp-p p 3.0 Vp-p a 3.0 Vp-p s 140 Vp-p d 130 Vp-p f 130 Vp-p
17
27U-S600 27U-S710
MODEL 27U-S600 SCHEMATIC DIAGRAM: MAIN-1 Unit
H
G
F
E
D
C
B
A
87109654321
18
Loading...
+ 42 hidden pages