
AIRLIFT™ S2 Electric Height-Adjustable Standing Desk
USER MANUAL

Initialization & Use Instructions
DESK MUST BE INITIALIZED BEFORE YOUR FIRST USE
SAVE MEMORY
MEMORY 1 / 2 / 3 / 4
DISPLAY
UP ARROW DOWN ARROW
Initialize
Press and hold the UP ARROW and DOWN ARROW simultaneously on the
controller until three blinking zeros appear on the display, then release.
The desk will descend to it's lowest height, then rise to it's highest height,
and then descend to middle-height.
When the number 38 (+/- 1) appears on the display, the desk is ready.
It may be necessary to reinitialize the desk from time-to-time due to power
outages or simply due to use over time.
If necessary, follow the above instructions to re-initialize.
Adjust Height
Press and hold the UP ARROW to lift.
Press and hold the DOWN ARROW button to lower.
Save Height
Press and hold the M button + Number button for 1 to 3 seconds until
the displayed number starts blinking.
Recall Height
Press the desired Number button twice, or press and hold to adjust to the
height stored at that number.
1

Troubleshooting
Problem Acon
Desk does not go up or down.
The controller does not illuminate
when any button is pressed.
Desk does not go up or down.
The controller illuminates when any
button is pressed.
Columns do not go up evenly. Unplug the power cord and re-plug after 10 seconds. Re-initialize
Desk wobbles excessively. It is normal that desk moves slightly at standing height when in
HOT is displayed on the panel.
Desk legs are noisy.
Check all connections. Make sure power cord is plugged into the
control box and a power outlet. Press any button on the controller
and make sure it illuminates. Re-initialize the desk.
Unplug the power cord and re-plug after 10 seconds. Re-initialize
the desk. If the problem persists, switch motor cables from one
port to another at control box and re-initialize again.
the desk. If the problem persists, switch motor cables from one
port to another at control box and re-initialize again.
use. Retighten all screws and bolts, and adjust leveling feet to
make sure table stands level.
The desk motors are overheated. Stop using the desk for 10
minutes and let them cool down.
It is normal that desk makes noise when the stages move past
each other. Apply silicon-based lubricant if it is unusually noisy.
Error Codes
Code Acon
E-1: System malfunction. Please contact customer service.
E-2: Starting current exception. Please re-initialize the system.
Press and hold the UP ARROW and DOWN ARROW simultaneously on the controller until three blinking zeros appear on the
display, then release. (see pg. 17)
If failure code still shows, please contact customer service.
E-4: Main power supply malfunction. Please contact customer service.
E-5: Motor is not running on the same
position.
E-6: Motor A stalling. Please re-initialize the system.
E-7: Motor B stalling.
E-8: Motor wiring malfunction.
E-9: Motor A Hall element malfunction.
E-10: Motor B Hall element malfunction.
Please re-initialize the system.
Please re-initialize the system.
Please re-initialize the system.
Please re-initialize the system.
Please re-initialize the system.
E-11: Height record error.
E-12: Over heat. Let the system cool down then re-initialize the system.
Please re-initialize the system.
2