Servend SII-008, SAII Service Manual

SII-008
ASSE Standard #1022-2003 Performance Requirements for
Backflow Preventer for Beverage Dispensing Equipment
ASSE Standard #1032-1980 Performance Requirements
for Dual Check Valve Type Backflow Preventers For
Carbonated Beverage Dispensers - Post Mix Type
8/09
Parts & Service Communicator
Subject: Double Check V alve Certification
SCOPE
SAll Servend/Multiplex equipment comes with a double check valve that meets ASSE standard #1032 or a back flow preventer that meets ASSE standard #1022. Those standards are listed below and may be found at www.asse­plumbing.org.
NSF certifies Servend/Multiplex equipment under standard 18. The website is www.nsf.org. Click on Food Equipment. Check standard 18. Our products are listed under Manitowoc Beverage Equipment.
Each check valve will be identified with NSF and ASSE ratings such as the pictures below.
ASSE Standard #1032-1980
The devices covered by this standard are those with functional capabilities for preventing back pressure backflow in water supply lines, and which can operate under continuous or intermittent pressure conditions. These devices consist of two independently acting primary check valves, internally force loaded to a normally closed position, in a common casing or valve body.
Devices may have a supplementary check valve downstream of the primary downstream check valve. Where it is incorporated in the design, it shall be held open by suitable means or removed for all performance tests where noted.
FURTHER ACTIONS
Contact Manitowoc Beverage Systems Service Sellersburg Indiana if you have any questions or concerns: 800-3 67-0427.
Manitowoc Beverage Systems Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
ANSI Approved - 2003
This standard covers a backflow prevention device designed to protect the potable water sup ply serving beverage dispensing equipment. These devices are intended for use under continuous or intermittent pressure conditions. They shall consist of two independently acting check valves biased to a normally closed position. An atmospheric port shall be located between the check valves and shall be biased to a normally open position. The port shall vent liquids, gases, or both, under backflow conditions.