SEKURE Ademco Vista-32FB User's Manual

9,,
9
3DUWLWLRQHG6HFXULW\6\VWHP
6
6
7
$
7
$
ZLWK6FKHGXOLQJ
)
)
8VHU*XLGH
%
%
K3522 3/99
FIRE
FIRE
PULL
*
TABLE OF CONTENTS
SYSTEM OVERVIEW ....................................4
General.......................................................4
A Partitioned System..................................4
Zones..........................................................5
Fire Protection ............................................5
Burglary Protection.....................................5
Alarms.........................................................6
Memory of Alarm ........................................6
Speed Key (Macros)...................................6
Using Schedules......................................... 7
Device Timers.............................................7
To Access Another Partition (GOTO
Command)..................................................7
Master Keypad Operation...........................8
Self-Help Feature........................................8
Phone Access & Voice Response
Capability....................................................8
ABOUT THE KEYPADS...............................10
General.....................................................10
The Alpha Keypad ....................................10
FUNCTIONS OF THE KEYPAD...................11
ENTRY/EXIT DELAYS.................................14
General Information..................................14
SECURITY CODES & AUTHORITY
LEVELS ....................................................15
General Information..................................15
Duress Code.............................................15
Quick Arming ............................................15
Authority Levels ........................................16
General Rules on Authority Levels and
Changes ...................................................17
To Exit User Edit Mode.............................18
To Add a User...........................................18
To Change a User's Code ........................20
To Delete a User.......................................21
ACCESSING OTHER PARTITIONS............22
To Access Another Partition.....................22
Global Arming...........................................22
Master Keypad Operation.........................23
Common Lobby Operation........................25
How User Codes Affect the Common
Lobby........................................................26
CHECKING FOR OPEN ZONES.................28
Using the
DISPLAYING ALL ZONE
DESCRIPTORS........................................29
Using the
BYPASSING PROTECTION ZONES ..........30
Using the 6
Quick Bypass............................................31
Displaying Bypassed Zones.....................31
ARMING PERIMETER ONLY ......................32
Using the 3
ARMING PERIMETER ONLY ......................33
Using the 7
ARMING ALL PROTECTION.......................34
Using the 2
ARMING ALL PROTECTION.......................35
Using the 4
DISARMING AND SILENCING ALARMS....36
Using the 1
Memory of Alarm ......................................36
USING THE KEYSWITCH ...........................37
General.....................................................37
Arming ......................................................37
Disarming..................................................37
CHIME MODE..............................................38
Using the 9 Key ...................................38
VIEWING CENTRAL STAT ION
MESSAGES..............................................39
General Information..................................39
PANIC KEYS................................................40
Using Panic Keys......................................40
SPEED KEY (MACROS)..............................41
Ready Key........................28
Ready Key........................29
Bypass Key.......................30
Stay key............................32
Instant Key........................33
Away Key..........................34
Maximum Key................... 35
OFF Key...........................36
– 2 –
General Information..................................41
Defining.....................................................41
Executing..................................................42
ACCESS DOOR CONTROL ........................43
General Information..................................43
USING #70 RELAY MENU MODE...............44
General Information..................................44
USING SCHEDULES...................................46
Delaying the Closing Time........................46
Temporary Open/Close Schedules ..........46
Programming Temporary Schedules........47
PROGRAMMING DEVICE TIMERS ............50
General Information..................................50
EVENT LOG PROCEDURES ......................53
General Information..................................53
To Display The Event Log........................53
EVENT LOGGING PROCEDURES
(CONTINUED)..........................................54
TESTING THE SYSTEM..............................55
Using the 5
Testing Your System ................................56
FIRE ALARM SYSTEM................................57
General.....................................................57
In Case Of Fire Alarm...............................57
Silencing A Fire Alarm ..............................57
Test Key ...........................55
Fire Display Lock ......................................58
Fire Drill Test (Code + # + 69)..................58
TROUBLE CONDITIONS.............................60
Typical Trouble Displays ..........................60
Power Failure............................................62
RECOMMENDATIONS FOR PROPER
PROTECTION..........................................63
Recommendations For Smoke And
Heat Detectors..........................................63
Recommendations For Proper
Intrusion Protection...................................65
EMERGENCY EVACUATION......................66
MAINTAINING YOUR SYSTEM ..................67
Taking Care of Your System ....................67
Replacing Batteries in Wireless
Sensors.....................................................67
Silencing Low Battery Warning Tones
at the Keypad............................................68
Routine Care.............................................68
QUICK GUIDE TO SYSTEM
FUNCTIONS.............................................69
SUMMARY OF AUDIBLE
NOTIFICATION ........................................71
GLOSSARY..................................................72
INDEX...........................................................78
– 3 –
System Overview
General
Congratulations on your ownership of an Ademco Partitioned Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today. Ademco is the world's largest manufacturer of security systems and millions of premises are protected by Ademco systems.
This system offers you three forms of protection: burglary, fire and emergency. To realize the full potential of the system, it is important that you feel comfortable in operating it. Your system consists of at least one keypad that provides full control of system operation, various sensors that provide perimeter and interior burglary protection, plus a selected number of strategically placed smoke or combustion detectors designed to provide early warning in case of fire.
The system uses microcomputer technology to monitor all protection zones and system status and provides appropriate information for display on the keypad(s) used with the system, and initiates appropriate alarms. Your system may also have been programmed to automatically transmit alarm or status messages over the phone lines to a central alarm monitoring station.
A Partitioned System
Simply stated, a partitioned system shares one physical alarm system among different users, each with their own requirements. For the most part, you as a user need not know about other users and their structure in the system, but from time to time, you may see display messages which indicate the system is in use by another user. Do not be concerned, this is normal. Refer to the section for additional information.
4
Accessing Other Partitions
Zones
Your system's sensing devices have been assigned to various zones. For example, the sensing device on your Entry/Exit door may have been assigned to zone 001, sensing devices on windows in the master bedroom to zone 002, and so on. These numbers will appear on the display, along with an alpha descriptor for that zone (if programmed), when an alarm or trouble condition occurs.
Fire Protection
The fire protection portion of your security system (if used) is always on and will sound an alarm if a fire condition is detected. Refer to the
Fire Alarm System
protection, smoke detectors and planning emergency exit routes from your house.
Burglary Protection
The burglary protection portion of your system must be turned on or armed before it will sense burglary alarm conditions. Your system provides four modes of burglary protection: Stay, Away, Instant and Maximum, and even allows you to bypass selected zones of protection while leaving the rest of the system armed. The system also provides a Chime mode, for alerting users to the opening and closing of doors and windows whi le the system is disar med. Refer to the oth er sections of this manual for procedures for using these features.
System Overview (cont’d)
section for important information concerning fire
– 5 –
System Overview (cont’d)
The following table lists the four different arming modes and the results of each.
Features For Each Arming Mode
Arming Mode
AWAY Yes Yes Yes Yes STAY Yes Yes Yes No INSTANT Yes No Yes No MAXIMUM Yes No Yes Yes
Alarms
When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm. If your system is connected to a central monitoring station, an alarm message will also be sent. To stop the alarm sounding, simply disarm the system.
Memory of Alarm
When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (e.g., Fire, Alarm). It remains displayed until it is cleared by disarming the system (see
Exit Delay
Disarming and Silencing Alarms
Entry Delay
Perimeter Armed
Interior Armed
section).
Speed Key (Macros)
The system can store a string of up to 32 keystrokes, which can be activated anytime by simply pressing the feature can be used to make it easy to perform a complicated procedure (such as going to another partition to bypass a zone), or it can be used to simp lify an ever yday, repeat ed procedur e. Refer to the
Speed Key (Macros)
6
A, B, C, or D
keys. This
section for procedures for using this feature.
System Overview (cont’d)
Using Schedules
Your system may have been programmed with schedules for automatically arming, disarming and activating various devices and/or performing other system functions at predetermined times. Users can modify some of these schedules by manually delaying a closing time, using temporary schedules, or by programming special user schedules. Refer to the manual for scheduling related procedures.
Device Timers
The system provides up to 20 timers which can be used to control various devices, such as lights or appliances. These timers are similar in concept to the individual appliance timers that might be purchased at a department store. The devices that can be controlled are programmed into the system by the installer. Up to 16 of these devices can be programmed. Refer to the for procedures.
To Access Another Partition (GOTO Command)
Using Schedules
Programming Device Timers
section at the end of this
section
Each keypad is assigned a default partition for display purposes, and will show only that partition's information. But, if the user is authorized, a keypad in one partition can be used to perform system functions in another partition using the GOTO command. Note that only those partitions authorized and programmed by the installer can be accessed in this manner.
To GOTO another partition, enter your security code, then press followed by the desired partition number (1-2).
The keypad will remain in the new partition until directed to go to another partition, or until 120 seconds has elapsed with no keypad activity. Entering partition number 0 will return the keypad to its original partition.
– 7 –
System Overview (cont’d)
Master Keypad Operation
A master keypad is one on which the status of both partitions is displayed simultaneously. A user can get more information about a
certain partition by simply entering number (1-2). To log on to the master partition (3) using the GOTO
command, a user must have access to all partitions.
Self-Help Feature
Abbreviated user's instructions are built into the system that can be easily viewed on the alpha keypad's message display screen. This feature will prove particularly useful if this manual is not conveniently accessible when you need to perform a system procedure with which you are not familiar.
To view the abbreviated instructions:
Simply press and hold down the function key of interest until the description starts to appear (about five seconds) and then release it.
Refer to the each key function.
Functions Of The Keypad
Phone Access & Voice Response Capability
Your system may include a 4285 or 4286 VIP module that will permit you to access the system via a touch-tone phone, either on-premises or by call-in when away. The phone access feature will enable you to do the following:
+ the desired partition
section for descriptions of
8
• Receive synthesized voice messages over the telephone regarding the status of the security system.
• Arm and disarm the system and perform most function commands via the telephone, with voice confirmation provided after each command entry.
System Overview (cont’d)
Control 4204/4204CF relays devices through the #70 Manual Relay Activation mode.
Complete information regarding the use of this feature is provided in a separate manual entitled accompanies the 4285 or 4286 VIP module.
Phone Access User's Guide
, which
– 9 –
About The Keypads
General
IMPORTANT: If the keypad beeps rapidly upon
entering the premises, it indicates that an alarm has
IMMEDIATELY and CONTACT THE POLICE
Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences. Keypad display back lighting is programmable to always stay on or to light only when a key is pressed, then turn off a few minutes later.
The keypads also feature a built-in sounder that will sound during alarms and troubles. It will also beep during certain system functions, such as during entry/exit delay times, during Chime mode, and when depressing keys to arm and disarm the system (to acknowledge the key press). These sounds can be optionally suppressed in some of your keypads (so as not to disturb other users of the system). Ask your installer if this has been done.
occurred during your absence. LEAVE
from a nearby safe location.
The Alpha Keypad
Alpha keypads feature a 2-line, 32 character alphanumeric Liquid Crystal Display (LCD) which can display system messages in friendly English. Abbreviated user's instructions can also be displayed (see
Self Help
can also be programmed with custom zone descriptors.
10
paragraph in the
System Overview
section). These keypads
Functions Of The Keypad
READYARMED
PANIC
OFF AWAY STAY
MAX TEST BYPASS
INSTANT CODE CHIME
READY
1
2
3
654 897 0
*
#
A
B
C
D
15
1
2
5
3
4
6
7
9
10
12
13
11
8
17
14
16
LOCATION OF DEDICATED PANIC KEYS.
KEY D USED AS SPEED KEY (if programmed)
IMPORTANT!:
sequential key depressions must be made within 3 seconds of one another. If 3 seconds elapses without a key depression, the entry is aborted and must be repeated from its beginning.
When using the keypad to enter codes and commands,
– 11 –
Functions Of The Keypad (cont’d)
1.
ALPHA DISPLAY WINDOW:
2-line, 32-character Liquid Crystal Display (LCD). Displays protection point identification and system status messages, and user instructions.
2.
OFF
KEY:
portion of the system, silences alarms and audible trouble indicators, and clears visual alarm trouble after the problem has been corrected.
3.
AWAY
both perimeter and interior burglary protection by sensing an intruder's movements through protected interior areas as well as guarding pr otected doors, windows, etc. Late arrivals can enter through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires.
4.
STAY
perimeter burglary protection, guarding protected doors, windows and other perimeter protection points, and sounds an alarm if one is opened. Interior protection is not armed, which allows movement within your house without causing
KEY:
Disarms the burglary
KEY:
Completely arms
Arms the
A
an alarm. Late arrivals can enter through an Entry Delay zone without causing an alarm if the system is disarmed before the entry delay time expires.
5.
MAXIMUM
similar to Away mode, but eliminates the entry delay period, thus providing maximum protection. An alarm will occur immediately upon opening any protection point, including entry delay zones.
6.
TEST
alarm sounder if disarmed.
7.
BYPASS
protection zones from being monitored by the system. Displays previously bypassed protection zones.
8.
INSTANT
similar to Stay mode, but turns off the entry delay period, offering greater security while inside and not expecting any late arrivals. An alarm will occur immediately upon opening any perimeter protection point, including entry delay zones.
9.
CODE
additional user codes that can be given to other users of the system.
KEY:
KEY:
Tests the system and
KEY:
KEY:
KEY:
Arms in manner
Removes individual
Arms in manner
Allows the entry of
– 12 –
Functions Of The Keypad (cont’d)
14.
10.
CHIME
Chime mode. When on, any entry through a protected delay or perimeter zone while the system is disarmed will cause a tone to sound at the keypad(s).
11.
READY
prior to arming the system, the keypad will display all open protection zones within the keypad's home partition. This key is also used to display all zone descriptors that have been programmed for your system, by holding the key down for at least five seconds.
12.
#
KEY:
system without use of a security code (Quick Arm, if programmed).
13.
KEYS 0-9:
individual security access code(s).
KEY:
KEY:
Permits arming of the
Turns on & off the
When depressed
Used to enter your
POWER/READY INDICATOR:
(GREEN) On some keypads, this lights when primary power is on. If off, the system is operating on its backup battery power. CALL YOUR INSTALLER IMMEDIATELY. On other types of keypads, lit indicates system is ready to be armed, while unlit indicates system not ready.
15.
ARMED INDICATOR:
when the system has been armed (Stay, Away, Instant or Maximum).
16.
INTERNAL SOUNDER:
audible, internal warning and confirmation sounds, as well as alarms (see
Notifications
17.
A-B-C PANIC KEYS:
Panic Keys
these keys.
Summary of Audible
).
section for descriptions of
(RED) Lit
Source of
Refer to the
– 13 –
Entry/Exit Delays
General Information
Your system has preset time delays, known as exit delay and entry delay. Whenever you arm your system, leave through the designated exit door without setting off an alarm. Exit Delay begins immediately after entering any arming command, and applies to all modes of arming protection. If programmed, a slow beeping will sound throughout the exit delay period.
Exit Delay
gives you time to
Entry Delay
through the designated entrance door. But the system must be disarmed before the entry delay period ends, or an alarm will occur. The keypad will beep during the entry delay period, reminding you to disarm the system. You can also arm the system with no entry delay at all by using either Instant or Maximum Arming modes. These modes provide greater security while on the premises or while away for extended periods of time. See your installer for your delay times.
gives you time to disarm the system when you reenter
– 14 –
General Information
At the time of installation, you were assigned an authority level and a personal four-digit security code, known only to you and yours. The security code must be entered when arming and disarming the system. The authority level defines the system functions that you can perform.
As an additional safety feature, other users that do not have a need to know your code can be assigned different security codes, and each user can be given a different authority level. Users are identified by user numbers, which are assigned when assigning a user's security code.
All codes can be used interchangeably when performing system functions within the limits of each code's authority level (a system armed with one user's code can be disarmed by another user's code), with the exception of the Operator Level C code. See section on the following page for detailed information regarding user authority levels.
Duress Code
Security Codes & Authority Levels
Authority Levels
Quick Arming
This feat ure is int ended f or use wh en you ar e force d to dis arm or ar m the system under threat. When used, the system will act normally, but can silently notify the central station of your situation, if that service has been provided. The Duress code is pre-assigned by the installer during installation (authority level 6).
Important:
central station.
Note that if Quick Arming was programmed by the installer, the # key can be pressed in place of the security code when arming the
This code is useful only when the system is connected to a
– 15 –
Security Codes & Authority Levels (cont’d)
system. The security code must always be used to disarm the system, however.
Authority Levels
Authority levels define the system functions a particular user can perform. Depending on the authority assigned to you, there are certain system functions you may be prohibited from performing. In summary, there are six authority levels, each having certain system restrictions as shown below.
Level 1 Master:
Level 2 Manager
Level 3 Operator A
Level 4 Operator B
Level 5 Operator C
Level 6 Duress
: Can perform system functions in assigned
: Can arm and disarm the system, but also
Can perform all system functions in assigned partitions, and can add, delete or change manager and operator level users. Master codes are added by the installer.
partitions, and can add, delete or change operator level users.
: Can perform system functions in assigned
partitions, but cannot add or delete other users.
: Same as Operator A, except Operator B
cannot bypass zones of protection.
: Can arm the system in assigned partitions,
but cannot disarm the system unless the system was armed with this code. This code is typically assigned to someone who has a need to arm/disarm the system only at certain times (such as a baby-sitter).
sends a silent panic alarm to the central station, if that service is connected.
– 16 –
Security Codes & Authority Levels (cont’d)
To view your authority level and system capabilities:
1. Enter your code +
2. The keypad will display the partition(s) that you are authorized to operate, and your user number and authority level in each partition.
+ .
General Rules on Authority Levels and Changes
A user may not delete or change the user code of the same or higher
authority than which he is assigned.
A user may only add users to a lower authority level.
A user may assign access codes only to those partitions to which the
user adding the code has access. (e.g., a user with access to only partition 1 cannot assign codes in partition 2.)
The only way to assign a user's authority level is by using the
procedure. To change a user's authority level, that user must
User
first be deleted, then added again.
A user can only be deleted or changed from within the partition to
which t h e user is assigned.
User numbers must be entered as 2-digit entries. Single digit user
numbers must be preceded by a 0 (example, 03, 04, etc.). Security codes are entered as 4-digit numbers.
Before assigning a security code, be sure it does not conflict with any
Duress code.
Add A
Note:
keypads in that partition will display, USER EDIT MODE – PLEASE STAND BY , and key depr essions ( except Pani c) at those k eypads wi ll be ignored. Panic key depressions will cause an alarm and terminate user entry.
When adding, changing or deleting users, all other alpha
– 17 –
Security Codes & Authority Levels (cont’d)
To Exit User Edit Mode
You can exit any of the user edit modes described on the following pages at any time by doing the following:
1. Press either
2. System returns to normal mode.
To Add a User
IMPORTANT:
system function they do not need to know (e.g. bypassing protection zones).
1. Enter master or manager code and press the 8 key.
2. Enter the new user's 2-digit user number (02-75).
3. Enter 4-digit security code for that user. The following prompts will
ADD NEW USER? 0 = NO , 1 = YES
USER NUMBER = 03 ENTER AUTH. LEVEL
appear.
or # , or d o n't pres s any ke y for ten s econds.
Temporary users should not be shown how to use any
CODE
Enter 1 to add a new user code. Entering
0
will change the existing user's code to the code entered in step 3. See
Changing A User's Code
section. Enter the authority level, 1-6, for this user
within this partition.
=master
1
=operator B
4
=manager
2
=operator C6=duress code
5
=operator A
3
18
ACCESS GROUP? ENTER 0-8
If access schedules have been programmed, this prompt appears. Enter the user's access group number
if this user should have
(1-8)
limited access to the system. Enter 0 if no access group should be assigned.
Security Codes & Authority Levels (cont’d)
RF BUTTON ? 0 = NO , 1 = YES
ENTER BUTTON ZN # (001-032)
MULTI-ACCESS ? 0 = NO , 1 = YES
GLOBAL ARM ? 0 = NO , 1 = YES
PART.2 - SHOP? 0 = NO , 1 = YES
This prompt will appear if a 5800 series button transmitter has been supplied and has not yet been assigned to a user. Press 1 if a button transmitter will be assigned to this user. Otherwise press 0.
If assigning a button transmitter, this prompt will appear. Enter the button's zone number (see your installer for zone number).
If you as a user have access to other partitions, the keypad will prompt for ability of this new user to access (GOTO) those partitions. Press 0 (No) or 1 (Yes). If no, the system activates this user code and exits Add a User mode. If yes, the keypad prompts for the Global Arm option for this user.
Press 1 (Yes) if this user will be allowed to try to arm more than one partition at the same time. Press 0 if this user will arm only his assigned partition.
The keypad now prompts for the users access to the next partition (see GOTO command). Again press 0 or 1. If yes, the system will automatically assign a user number for use in that partition and will prompt for the authority level and global arm option for this user within the partition (see previous steps).
– 19 –
Security Codes & Authority Levels (cont’d)
PART. 1 A0✱ WHSE USER 03 AUTH=3G.
To Change a User's Code
1. Enter master or manager code and press the 8 key + user number to be changed.
2. Enter the new code for that user.
ADD NEW USER? 0 = NO , 1 = YES
When all partitions have been displayed, the keypad will scroll through the partition(s) to which access has been assigned, and will display the user number, authority level and global arm option for each. The G after the authority level indicates that the global arm feature is active for this user in the displayed
partition. The ✱ indicates the partition from which this user can be changed or deleted. The . at the end of the second line indicates that this user sends open/close reports. Open/close reporting is automatically active for any users added by you, if you have open/close reporting active.
CODE
The system will recognize that the user number is already in use and will prompt whether or not this is a new user. Enter to change the existing user's code to the code entered in step 2.
0
20
USER 02 CHANGED SUCCESSFULLY
The system will confirm that the change is allowed based on authorization level, and if so, will put the new code into effect.
that if changing one’s own code,
Note
the system will prompt for the new code to be reentered. This prevents accidentally changing one's own code.
Security Codes & Authority Levels (cont’d)
To Delete a User
1. Enter master or manager code and press the 8 key + user number to be deleted.
2. Enter master or manager code first entered.
CODE
OK TO DELETE 0 = NO , 1 = YES
USER CODE DELETED
The system will recognize that the user number is already in use and will prompt to confirm that it should be deleted. Press (No) or 1 (Yes).
If yes, that user's code will be removed from all partitions to which it was assigned, and all authorization levels and other information about that user will be deleted. Note that a user can only be deleted from the partition in which it was first assigned, and can only be deleted by a user with a higher authority level. A User's security code cannot be deleted by that user.
0
– 21 –
Accessing Other Partitions
To Access Another Partition
Each keypad is assigned a default partition for display purposes, and will show only that partition's information. But, if the user is authorized, using the GOTO command can use a keypad in one partition to perform system functions in other partitions. Note that only those partitions authorized and programmed by the installer can be accessed in this manner.
To GOTO another part it io n:
1. Enter your security code, then press + partition number (0-3).
2.
Global Arming
The Global Arming option may have been programmed for use by some users. If Global Arming was enabled for use with your security code, a keypad prompt (message) will appear after pressing one of the arming function keys (Stay, Instant, Away, Maximum, Off). Follow the keypad prompts to continue arming the system. See your installer for detailed instructions on the use of this feature.
If global arming does not apply to your security code, use the procedures described in the following pages.
READY
Entering partition number 0 will return the keypad to its original partition.
LOG-ON TO AAAA PART. X COMPLETE
The keypad will remain in the new partition until directed to go to another partition, or until 2 minutes has elapsed with no keypad activity. AAAA = alpha descriptor programmed by the installer X = partition number
– 22 –
Accessing Other Partitions (cont’d)
Master Keypad Operation
A master keypad is one that reflects the status of the entire system (Partitions 1-2) on its display. This is useful because it eliminates the need for a security officer in a building to have to log-on to various partitions from one partition's keypad to find out where an alarm has occurred.
A description of a typical display follows:
The status of each partition is directly below the partition number on the display. Possible status indications include:
A = Armed Away M = Armed Maximum S = Armed Stay I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready
SYSTEM 1 2 STATUS R N
= Alarm Memory/Trouble present
To obtain more information regarding a particular partition, enter
+ [Partition No.]
(i.e.,
2). This will allow viewing only of that
[
partition. In order to affect that partition, the user must log on with a code that has access to that partition. Also, in order for a user of any partition to log onto the Master partition (Partition 3) to view the status of all partitions, that user must have access to all partitions. Otherwise, access will be denied.
The following is an example of what would be displayed for a fault condition on Zone 2 (Loading Dock Window) on Partition 1 (Warehouse) when logging on from a keypad on Partition 3:
WHSE DISARMED
HIT ✱ FOR FAULTS
This is the normal display that appears at Partition 1's keypad(s).
23
]
Accessing Other Partitions (cont’d)
Pressing ✱ will display:
FAULT 002 LOADING
DOCK WINDOW
Additional zone faults will be displayed one at a time. To display a new partition's status, press the status of the new partition.
The Armed LED on a master keypad will be lit only if all partitions have been armed successfully. The Ready LED will be lit only if all partitions are ready to arm.
The sounder on a master keypad will reflect the sound of the most critical condition on all of the partitions. The priority of the sounds is as follows:
A. Pulsing fire alarm sounds B. Steady burglar alarm sounds C. Trouble sounds
The sounder may be silenced by pressing any key on the master keypad.
] + [Partition No.]
[
. This will display
– 24 –
Loading...
+ 56 hidden pages