58
ERROR MESSAGES
18
ERROR MESSAGES 18
When an error occurs in the mechanism, a number corresponding to the error is displayed on the 7-seg displays on
the side (1P or 2P) that the error has occurred. Press the test switch to enter test mode.
Test the mechanism and confirm the location of the error before exiting test mode.
After initialization, credits attained before the error are restored and the game resumes. (Partial credits attained for
multiple coins are deleted). For details, see [11-3 Explanation of Test Mode].
When an error has occurred, the credits are displayed in 2 digits on the small 7-seg displays.
If an error of unknown cause occurs and cannot be resolved, or if the same error occurs frequently, turn the power
off and contact the office indicated on these instructions or where the product was purchased.
No.
7-seg Display
Reads Cause
0 00E BACK limit sensor in the X-direction does not turn ON.
1 01E BACK limit sensor in the X-direction does not turn OFF.
2 02E FWD limit sensor in the X-direction does not turn ON.
3 03E FWD limit sensor in the X-direction does not turn OFF.
Corrective Measure: Errors involving left/right movements. Check the limit sensor and its operation in test
mode 1. (See Section 11)
4 04E BACK limit sensor in the Y-direction does not turn ON.
5 05E BACK limit sensor in the Y-direction does not turn OFF.
6 06E FWD limit sensor in the Y-direction does not turn ON.
7 07E FWD limit sensor in the Y-direction does not turn OFF.
Corrective Measure: Errors involving forward/backward movements. Check the limit sensor and its operation in
test mode 1. (See Section 11)
8 08E UP limit sensor in the Z-direction does not turn ON.
9 09E UP limit sensor in the Z-direction does not turn OFF.
10 10E DOWN limit sensor in the Z-direction does not turn ON.
11 11E DOWN limit sensor in the Z-direction does not turn OFF.
Corrective Measure: Errors involving up/down movements. Check the limit sensor and its operation in test
mode 2. (See Section 11)
12 12E Open sensor does not turn ON.
13 13E Open sensor does not turn OFF.
Corrective Measure: Errors involving open/close movements. Check the open sensor and its operation in test
mode 3. (See Section 11)
14 14E There is no coin meter attached.
Corrective Measure: Errors involving the coin meter. Check the meter, its operation, and wire connections.
15 15E Problem with the prize sensor.
Corrective Measure: Errors involving the prize sensor. Check the prize sensor and its operation in test mode.
(See Section 11)
20 Problem with the X-axis.
Corrective Measure: Errors involving the X-axis. Check the limit sensor and its operation in test mode 1.
21 Problem with the Y-axis.
Corrective Measure: Errors involving the Y-axis. Check the limit sensor and its operation in test mode 1.
If the following errors occur after the power supply has been
activated, there may be a problem with the DIP SW board.
TABLE 18