SECURING THE SATELLITE PLACEMENT POSITIONS
Be sure that all adjusters are placed against the oor. Failure to place the adjusters
against the oor could lead to accidents caused by cabinet movement.
WARNING!
Each satellite is equipped with 4 adjusters and 4 casters. When the placement position has been
determined, place the adjusters directly against the oor and perform adjustments to make the
satellite horizontally level.
1
Move the satellite to the placement
position.
2
Remove the 2 screws at each cor-
ner to remove the lower covers.
LEG COVER FRONT
SCREW(2 each)
M4×12
ADJUSTERS
CASTERS
FIG. 6. 2 a BOTTOM VIEW OF THE SATELLITE
LEG COVER REAR
www.seuservice.com
PHOTO 6. 2 a
34
3
Place all the adjusters against the oor. Use a wrench to adjust the height of the adjusters so that
the satellite is horizontally level.
Following adjustment, tighten the nut on each adjuster to x the height.
4
Be sure to make contact with the surface.
Fasten upward.
PHOTO 6. 2 b
5
Replace the 4 covers at the corners.
FIG 6. 2 b
Refer to this gure (scale: 1/100) for
the layout of the place of installation.
6
Follow the procedure below to attach the instruction plate and the instruction holder to the
service door.
Exercise caution, as the service door closes by its own weight, and can injure hands or ngers.
Do not over-tighten the ange nuts, as this could damage the instruction plate.
CARRIAGE BOLT (6)
7
Release and open the service door.
Secure the instruction plate to the service
8
door using 6 carriage bolts and ange/cap
M4×10, chrome plated
INSTRUCTION PLATE
INSTRUCTION HOLDER
nuts. Push the carriage bolts all the way
through the holes, and tighten the 4 ange
nuts from the inner side of the service door
CAP NUT (2)
M4, at washer used
and the 2 cap nuts in the upside.
SERVICE DOOR
35
FLANGE NUT (4)
M4
Release
FIG. 6. 2 c
www.seuservice.com
3
POWER SUPPLY, AND EARTH CONNECTION
● Be sure to independently use the power supply socket outlet equipped with
WARNING!
● This product is designed for an electrical outlet with an earth element. The
● If an electrical outlet with an earth element is not available and a commercially
● In order to ground securely, do not use the service outlet to supply the power
● The electric current capacity of the service outlet for the satellites is 10A max.
● Ensure that the power cord and earth wire are not exposed on the surface (pas-
an Earth Leakage Breaker. Using a power supply without an Earth Leakage
Breaker can cause a re when electric leakage occurs.
power cord incorporates an earth wire. Improper grounding could result in
electrical shock to customers, damage to components, and/or malfunctioning.
distributed conversion adapter is used, make sure that the product's earth terminal is connected to a grounded terminal using an earth wire. Improper grounding could result in electrical shock to customers, damage to components,
and/or malfunctioning.
of the other satellites. Improper grounding could result in electrical shock to
customers, damage to components, and/or malfunctioning. (For TAIWAN)
Never use the service outlet for the machinery exceeding 10A. Using the
machinery exceeding 10A can cause generation of heat and re hazard. (For
TAIWAN)
sage, etc.). If exposed, they can be caught and are susceptible to damage. If
damaged, the cord and wire can cause electric shock and short circuit accidents. Ensure that the wiring position is not in the customer's passage way or
the wiring has protective covering.
The AC unit for the main projection unit is located at the back of the cabinet. The AC unit features a
main switch, a circuit protector, an earth terminal, and an inlet for connecting the power cord.
The AC unit for each satellite is also located at the
back. These AC units feature a power switch, a circuit
protector, an earth terminal, an inlet for connecting the
power cord, and a service outlet.
When connecting the satellite
power source and earth, place the
latch located at the end of the chain
extending from the AC cover onto
the hook located on the back of the
satellite. This will secure the AC
cover in the open position. When
the work is nished, replace the
latch onto the hook located on the
back of the AC cover and close the
cover.
HOOK
LATCH
FIG. 6. 3 a
AC COVER
www.seuservice.com
36
Ensure that the main switch is OFF.
9
CIRCUIT PROTECTOR
Main SW off
AC Cable (Power Cord)
MAIN SW
AC COVER
INLET
EARTH TERMINAL (for TAIWAN)
Connect with the
indoor earth terminal.
FIG. 6. 3 b AC UNIT OF THE MAIN PROJECTION UNIT
CIRCUIT PROTECTOR(10A)(For TAIWAN)
(For Service outlet)
SERVICE OUTLET (For TAIWAN)
EARTH TERMINAL (For TAIWAN)
Connect to the
indoor earth terminal.
INLET
POWER SW OFF.
CIRCUIT PROTECTOR(5A)
10
Firmly insert the power plug into the socket outlet. Insert the opposite side of the power cord
plug to the AC unit's connector (INLET).
POWER SWITCH
FIG. 6. 3 c AC UNIT OF THE SATELLITE
37
www.seuservice.com