Securitron DT-7 Specsheet

C
www.securitron.com | techsupport@securitron.com
© 2015, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
B
A
MODEL
NOTE:ALL DIMENSIONS IN
A7B
3.187C2.5
INCHES.
DIGITAL TIMER 7 DAY—DT-7
Features
10
Can be operated in Toggle or Pulse mode
12 programmed On/Off times
Selectable day blocks (Mon-Fri, Sat-Sun)
The exclusive “First Man In” automates
Operates on 12/24 volts AC or DC
Current draw is 170 mA
A “AA” battery will provide five (5) year backup to the display module
Operating Temperature
Amp DPDT relay
holiday programming in many
applications
7 to 43C [45 to 110F]
How to Order
Part #
Description
DT-7 Digital Timer 7 Day
DIGITAL TIMER 7 DAY—DT-7 (cont’d)
www.securitron.com | techsupport@securitron.com
Architectural Specification—Digital Timer (DT-7)
A. The Dig
manufacturer.
B. The timer shall be of the daily or weekly digital timer type
C. The timer shall operate on 12 or 24 volt AC or DC.
D. The timer shall have 12 program instructions, including block instructions
for Monday - Sunday, Monday - Saturday, and Monday - Friday
E. The timer shall be capable of controlling loads of up to 10 amps at 12 or
24 volt AC or DC via a DP/DT relay.
F. The timer shall be equipped with a first man in feature to increase
security.
G. The timer’s program memory is maintained in a power failure by an on-
board alkaline battery.
ital Timer shall be produced by an ISO 9001 certified
Loading...