Seco-Larm SD-995A-D3Q User Manual

Unique design accommodates both wood and
Operating voltage: 12 VAC/VDC
Features:
SD-995A-D3Q
Weatherproof Door/Gate Strike
Manual
Fail-secure operation Reversible for right or left-handed doors Zinc alloy body Corrosion-resistant case and moving parts Complete mounting hardware included
1,034-lb (470kg) Holding force Tested to 250,000 cycles Current draw: 310mA@12VDC Strike depth: 9/16" (15mm) Faceplate size: 31/2"x17/16"x1/8"
(89x35x3 mm)
SECO-LARM® Weatherproof Door/Gate Strike
Specifications:
Model
SD-995A-D3Q
Operation
Fail-secure
Operating voltage
12 VAC/VDC
Current draw
310mA@12VDC
Design
Reversible non-handed
Max. latch throw
9
/16" (15mm)
Keeper width
15/8" (41mm)
Strike depth
9
/16" (15mm)
Holding force
1,034-lb (470kg)
IP Rating
IP42
Operating temperature
14°~113° F (-10°~45° C)
Operating humidity
0~95% RH (no condensation)
Faceplate dimensions
31/2"x17/16"x1/8" (89x35x3 mm)
Weight
12.1-oz (343g)
Parts List:
1x Door strike
1x Mounting template
2x Mounting tabs
2x Wood screws
4x Machine screws
2x Crimp connectors
1x Manual
Sides
Top
17/16"
(35mm)
11
/16"
(17.5mm)
5
/8"
(15.35mm)
25/8" (67mm)
15/8"
(41mm)
11/16"
(27.5mm)
11
/16"
(17mm)
17/8"
(47mm)
Dimensions:
31/2"
(89mm)
3"
(76mm)
2 SECO-LARM® U.S.A., Inc.
SECO-LARM® Weatherproof Door/Gate Strike
1. Measure the latch line (see fig. 1).
the door jamb and the face of the door latch.
2.
3.
4.
If cutting into a wooden door, use a chisel
5.
6.
7.
Installation:
Fig.4
Fig.3
Fig.2
Fig.1
Door latch
Door jamb
Deadlatch pi n
X
Latch line
Fig.5
a. Measure the distance between the face of
This is the vertical latch distance.
b. Measure the vertical latch distance on the
door jamb from the face of the door jamb. At that point, draw a vertical line. This is the latch line.
Measure the center line (see fig. 2).
a. Measure the distance from the floor to the
center of the door latch. Ignore the location of the deadlatch pin when taking measurements.
b. Measure the same distance as above along
the inside of the door jamb. This is the center line.
Align the included mounting template to the latch
and center lines (see fig. 3)
Using the template as a guide, cut into the door
jamb to a depth of
NOTE:
to knock out a 1/8” (3mm) deep cut as shown on the template.
Using two of the included machine screws, affix
the mounting tabs to the inside of the door jamb (see fig. 4).
Connect the two wires from the access control or
egress device, e.g. keypad, push-button switch, push-bar, etc. to the door strike wires. Polarity is not important.
Conceal all wires in the door frame. Use two of
the included machine screws to mount the unit to the mounting tabs. Adjust as needed to ensure the door closes smoothly (see fig. 5).
3
/4” (19mm).
Vertical latch distance
SECO-LARM® U.S.A., Inc. 3
SECO-LARM® Weatherproof Door/Gate Strike
Electric strike does not activate
Remove the strike and check that the wires are
Door does not open when the
Check that the door latch is operating properly, and
adjusted by moving it or adding washers or shims
Troubleshooting:
Also Available:
Fail-Secure Electric Door Strike
Fail-Safe Electric Door Strike
Indoor Access Control Keypad
Electric Door Strike for Metal Doors
Electric Door Strike for Wood Doors
Universal Door Strike
WARRANTY:
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for three (3
LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects i
The sole obligation of
SECO
LARM’s
option.
consequential personal or property
damage of any kind to the purchaser or anyone else.
NOTICE:
However, the
SECO
LARM reserves the right to change specifications without notice. Copyright © 2016
y not be reproduced or copied, in whole or
in part, without the written permission of SECO
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
PITGW1
Phone: (949) 261-2999 | (800) 662-0800
Email: sales@seco-larm.com
SD-995C
SD-990AQ
electric strike is activated
) years from the date of sale to the original customer. SECO-
SD-994C
SD-990BQ
SD-996C-NUQ
SK-1011-SDQ
connected properly
Use a multimeter to test that the strike is receiving the proper voltage and amperage. If it is not, it may be necessary to use heavier gauge wires, or increase the output of the power supply
Make sure the activation device (keypad or pushbutton switch) is working properly
replace if necessary
The position of the electric strike may need to be
-LARM.
-
LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO­ In no event shall SECO-LARM be liable for any special, collateral, incidental, or
The information and specifications printed in this manual are current at the time of publication.
-LARM policy is one of continual development and improvement. For this reason, SECO-
SECO-LARM U.S.A., Inc. All rights reserved. This material ma
SECO-LARM is also not responsible for misprints or typographical errors.
4 SECO-LARM® U.S.A., Inc.
-LARM.
n material and workmanship.
MI_SD-995A-D3Q_160518.docx