FEATURES AND SPECIFICATIONS
AC (with lock in opening and closing position) SC (with lock only in closing position) SA (with lock only in opening position)
The FULL TANK is a high quality hydraulic operator for condominium use for gates with leaf lengths up to max. 7 m.
The lock is guaranteed for leaf lengths up to 180 m with the 270 version and up to 2,20 m with the 390 version. For leaf lengths exceeding 2,20 m it is necessery, in all versions, to install an electric lock.
Available in the following versions:
SB (without lock)
The Full Tank is supplied with by-pass valves for the power regulation in both opening and closing. Electronic adjustable slow down in opening and closing with electronic control board. For the European laws and directives actually in force it is strongly recommended to use the Safety Gate (device for the reading of the gate position), for reverse in case of obstacle.
Dimensions (mm)
FULL TANK
EnglishEnglish
* Version with brake in closing + 25 mm Version with brake in opening and closing + 50 mm
Note: The frequency of use is valid only for the first hour at 20°C room temperature.
Note: in non-automatic logic, use operators without lock.
USING GRAPHIC
FULL TANK OPERATOR
Sistemi Elettronici
di Apertura Porte e Cancelli
®
7 m
70
FULL TANK 270
(230V-120V)
FT 270
(230V-120V)
6 m
Fig. 1
0 71
5
*
F
T 2
0
2
0
*
T 0
9
8
7
F 2
0
3
2
-
0
7
9
9
0
5
6
*
F
1
2
70
T
3
9
0
21
T
31
9
5*
F
0
FULL TANK 270 FULL TANK 390
FULL TANK 390
(230V-120V)
FT 390
(230V-120V)
4 m 3 m
FULL TANK 270
FAST
FT 270
FAST
FULL TANK 390
FAST
FT 390
FAST
Cicles/hour
OPERATORS
Max. leaf length
Fig. 2
FT 270 (230V) FT 390 (230V) FT 270 (120V) FT 390 (120V) FT 270 FAST FT 390 FAST 230V (±5%) 50/60 Hz 120V 60 Hz 230V (±5%) 50/60 Hz
220 W 300 W 310 W 1 A 2,45 A 1,5 A 270 mm 390 mm 270 mm 390 mm 270 mm 390 mm 1 cm/s 1,5 cm/s 1,2 cm/s 1,7 cm/s 3,35 cm/s 70 40 bar 30 bar 40 bar 35 bar
-20°C +55°C 130°C 640da N 480 daN 500 daN 12,5µF 60µF 12,5µF 12,8 kg 15,2 kg 12,8 kg 15,2 kg 13 kg 15,4 kg IP55 6 m 7 m 6 m 7 m 3 m 4 m 90° / 125°
Fig. 3
TECHNICAL FEATURES
Operating temperatures Thermal protection M
P
Power supply Power Absorbed current Stroke Shaft speed Cycles hour (at a temp. of 20°C) Max working pressure
ax Thrust Capacitor Weight
rotection class Max leaf lenght Opening degree of the leaf
11
33
44
22
5
6
7
8
1. Shaft cover
2. Release
3. Front bracket
4. Rear bracket
5. Cylinder
6. Electric motor
7. Hydraulic pump
8. Exit electric cables
15
Release
By-pass valves
Clevis Attachment
Rear attachment
Breather screw
Pin rear
attachment
(short)
Brass Pin (long)
Front bracket
Shaft Cover
End cover
Fig. 4
Shaft
FULL TANK
EnglishEnglish
Oil fill in cover
Sistemi Elettronici
di Apertura Porte e Cancelli
®
16
TYPICAL INSTALLATION
INSIDE
OUTSIDE
1. Full Tank operator
2. Mechanical stop
3. Control board
4. Warning lamp
5. Photocell tx
6. Differential switch 16A-0,03A
7. Photocell rx
8. Key switch start-stop
9. Antenna
10. Column for photocells
11. Warning notice
12. Safety Gate
TYPE OF INSTALLATION
It is possible to install the Full Tank with opening inside (Fig.5) or opening outside (Fig.6).
Install the operator always inside the property.
inside
inside
Outside
Outside
Inward installation Outward installation
Fig. 5
Fig. 6
FULL TANK
EnglishEnglish
11
33
44
1010
1010
11
77
1212
1212
55
99
88
22
66
22
11
2
x
1,5
2
x1
x
.3
1 SC
H
3
1 C
H
x S .
3x1
,5
2x1
3
x
1
,
5
3x
1
,
5
21
x
3
x
1
R
G 5
8
Sistemi Elettronici
di Apertura Porte e Cancelli
®
17
a
d
b
c
Fig. 7 encore
INSIDE OPENING INSTALLATION
To obtain 110° with d > 55 mm it is necessary to make a niche in the gate.
INSIDE OPENING INSTALLATION
To obtain 125° with d > 55 mm it is necessary to make a niche in the gate.
Outside
a
d
b
c
Fig. 7
Outside
Inside
Inside
Total stroke 270 mm - max. recommended stroke 250 mm
a b d
max
Max.
Opening
Angle
(mm)
(mm)
(mm)
250
215
250
250
215
250 225
250 235
255 242
250 242
250 250
100 100 105 105 120 120 125 140 140 145 145 150 155 160 170 180
115 150 110 145 105 130 125
95
110
95 105 100
85
90
75
65
50 50 55 55 70 70 75 90 90 95
95 100 105 110 120 130
110°
90°
110°
90°
106°
90° 90°
100°
90°
100°
90° 90° 96° 90° 92° 92°
250 250
250
250 250
253
245
Max. Stroke (mm)
Stroke for 90°(mm)
Total stroke 390 mm - max. recommended stroke 370 mm
a b d
max
Max.
Opening
Angle
(mm)
(mm)
(mm)
368
295
372
300
372
370
370
310
370 330
370
371
355
355
370
370
360
365
369
370
370
125 130 140 145 145 160 175 185 185 195 195 240 240 250 250 260 260 270 280 295
170 170 235 165 230 210 195 145 190 140 175 110 125 105 115
95
100
90 80 65
75 80 90 95
95 110 120 130 130 140 140 185 185 195 195 205 205 215 230 245
125° 125°
90°
120°
90° 90° 90°
110°
90°
110°
90°
100°
90° 95° 90° 95° 90° 90° 90° 90°
370 370
370
370
370
370
369
Stroke max (mm)
Stroke for 90°(mm)
FULL TANK
EnglishEnglish
Sistemi Elettronici
di Apertura Porte e Cancelli
®
18
Fig. 8 encore
OUTSIDE OPENING INSTALLATION
OUTSIDE OPENING INSTALLATION
Fig. 8
a
d
b
c
Inside
Outside
a
d
b
c
Inside
Outside
a b
Max.
Opening
Angle
(mm)
(mm)
250
240
250
250
243
241
150 160 165 175 180 180
90 90 80 80 70 65
95° 90° 95° 90° 90° 90°
250
249
Stroke max (mm)
Stroke for 90°(mm)
Total stroke 270 mm - max. recommended stroke 250 mm
a b
Max.
Opening
angle
(mm)
(mm)
356
342
345 336
330
335
319
250 255 265 270 275 275
100 95 95 90 90 90
100°
95° 95° 90° 90° 90°
325
342
Max. Stroke
(mm)
Stroke for 90°(mm)
Stroke 390 mm - max. recommended stroke 370 mm
FULL TANK
EnglishEnglish
Sistemi Elettronici
di Apertura Porte e Cancelli
®
19
Loading...
+ 14 hidden pages