This is the parts list for the SCE170. When looking
up part numbers, always check the complete
model and serial numbers to be certain of ordering
the correct parts.
The SCE170 has been manufactured in A, B and
C series configurations. It has also been
manufactured in 50 and 60 Hz.
60 Hz model numbers end in -1, 50 Hz in -6.
Model number examples include:
SCE170A-1A - A Series (Copeland
·
Compressor)
SCE170A-1B - B series (Tecumseh
·
Compressor)
SCE170W-1C - C series (water cooled
·
condenser change)
SCE170A-1H - H series color change
·
SCE170W-1H - H series color change
·
TABLE OF CONTENTS
Plastic tubing that has a length measurement in
the description is sold by the foot, order 1 unit, and
1 foot will be shipped. Order enough to cover the
length required. Lengths of tubing are listed under
the description column.
Cabinet .................................Page 2
Air cooled refrigeration ...........................Page 3
Water cooled refrigeration ..........................Page 4
Subject: SCE170 Air Cooled High Pressure Cut Out Change
Beginning with serial numbers ending in -04B (October 1998 production), the high pressure cut out
(also called the high pressure control) has been changed from a manual reset to an automatic reset.
When replacing a defective high pressure cut out on an air cooled SCE170, replace the old switch
(part number 11-0485-22 - cut out at 450 PSIG), with the new switch, part number 11-0501-22 (cut
out at 450 PSIG, cut in at 350 PSIG).
Although the new cut out connects to the machine’s wiring in the same place as the original’s, when
replacing a manual reset cut out, quick connects will have to be added to the existing wires so they
can be plugged onto the new switch. Also, part number 11-0485-22 will continue to be used as a
service part for other products.
The SCE170 has had a model series revision. The new models are SCE170A-1B and SCE170W-1B.
The changes are in the refrigeration system and include a new compressor.
The A37824-021 compressor kit (Tecumseh) replaces the prior Copeland compressor, which is no
longer available. The kit includes the new compressor (plus relay, capacitor, overload and a drier) and
the necessary tubing to connect it to the refrigeration system of the A series. Refer to the instructions
that are included with the kit for detailed information.
The B series refrigerant charge has changed from the A series:
·
Air cooled B series is 16 ounces
·
Water cooled B series is 11 ounces, both remain R-404A.
SCE170 B Series: The replacement TXV for this series machine has been changed. Although the
service kit part number remains 16-0868-22, the TXV supplied in the kit is now part number
16-0868-03.
When installing a 16-0868-03 TXV on a B series SCE170 that had the prior valve, relocate the
TXV bulb from its vertical suction line location to the horizontal suction line position, just to the right
(when viewed from the back) of the cube size control bulb.
Production of SCE170s with this valve began in early November, 2001, and they have the TXV bulb
next to the cube size control bulb, so they do not require bulb relocation when replacing the TXV.
The A series valve does not change.
AFE400: The replacement TXV for the AFE400 has been changed from 16-0996-01 to 16-1091-21.
These valves are completely interchangeable. Production of AFE400s with the new valve began in
early December, 2001.