Scotsman SCCP50M-1WU, SCCG50M-1WU, SCCP50M-1BU, SCCG50M-1BU, SCCP50M-1SU Installation and User's Manual

...
Installation and User's Manual for Residential Ice Machine
Models SCCG50 and SCCP50
SCCG50 & SCCP50 Installation and User's Manual
Introduction:
This ice machine is the result of Scotsman’s decades of experience as an industry leader in the design and manufacture of both commercial and residential ice machines.
This manual includes the information needed to install, start up and maintain the ice machine. Note any Caution or Warning indicators, as they provide notice of potential hazards. Keep this manual for future reference.
Table of Contents
Specifications .......................................... Page 2
Cabinet Layout ......................................... Page 3
Air flow ............................................. Page 4
Water Quality .......................................... Page 5
Door Covering .......................................... Page 6
Door Panel Attachment ..................................... Page 7
Door swing change ....................................... Page 8
Installation: Water & Drain ................................... Page 9
Gravity Drain .......................................... Page 10
Electrical ............................................ Page 11
Use ............................................... Page 12
How to clean the condenser and winterize. ........................... Page 13
How to remove scale from the ice making system. ....................... Page 14
July 2018
Page 1
Specifications
SCCG50 & SCCP50
Installation and User's Manual
This ice machine is designed to be used indoors, in a controlled environment. It can be used in a wide variety of environmental conditions, but there are limits. Use outside of the listed limitations is misuse and will void the warranty.
Air temperature limits:
The ice machine will operate adequately within the limits, but functions best in temperatures between 70 and 80 degrees F.
Minimum – 50 degrees F. (10
Maximum – 100 degrees F. (38
Water temperature limits:
Minimum – 40 degrees F. (4.5
Maximum – 100 degrees F. (38
Water pressure limits:
o
C)
o
C)
o
C)
o
C)
Minimum – 20 psi (1.4 bar)
Maximum – 80 psi (5.5 bar)
Because the ice machine is making a food product, the water supply to the ice machine must be potable, or fit for human consumption.
Options:
Door Panels: Finished door panels are available from Scotsman for attachment to the machine, or a custom panel can be made. The panel kits are:
Kit Number Panel Finish Handle Finish
KDFW White White
KDFWS White Stainless Steel
KDFB Black Black
KDFBS Black Stainless Steel
KDFS Stainless Steel Stainless Steel
Kickplate Extension: In some situations the leg levelers will be extended enough to become visible. A kit to extend the kickplate over the legs is KKPF.
Cabinet Stability: In some free standing installations it may be prudent to add a bracket that secures the back of the cabinet to a wall. That kit number is KATB.
Drain Conversion: A gravity drain model can be converted to a drain pump model by installing a drain pump kit. The drain pump kit consists of a drain pump, wiring harness and associated tubing. The part number is A39462-021.
Electrical voltage limits:
Minimum - 104 volts
Maximum – 126 volts
Models
There are six models, all air cooled:
Warranty Information
Warranty information is supplied separately from this manual. Refer to it for coverage. In general, the warranty covers defects in materials or workmanship and does not cover corrections of installation errors or maintenance.
SCCP50M-1WU – Pump model, white cabinet
SCCG50M-1WU – Gravity drain model, white cabinet
SCCP50M-1BU – Pump model, black cabinet
SCCG50M-1BU – Gravity drain model, black cabinet
SCCP50M-1SU – Pump model, stainless cabinet
SCCG50M-1SU – Gravity drain model, stainless cabinet
Cabinet Dimensions
Width Depth, w/out door panel Depth, with door panel, handle adds 1 5/8" Height
14 7/8" 22" 22 3/4" 33 3/8" to 34 3/8"
July 2008
Page 2
SCCG50 & SCCP50 Installation and User's Manual
Cabinet Layout
June 2008
Page 3
Air flow
The machine takes in room temperature air at the lower right front and forces warm air out the lower left front. Restricting the airflow will adversely affect the ability of the ice machine to make ice.
Clearance requirements: 0 inches at the top, 2 inches at the rear and an 1/8 inch at each side.
SCCG50 & SCCP50
Installation and User's Manual
Air IntakeWarm Air Out
Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of agencies like U.L.
Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any parts and/or other components not specifically approved by Scotsman.
Scotsman reserves the right to make design changes and/or improvements at any time.
Specifications and designs are subject to change without notice.
Model and Serial Number Tag
Control Panel
Ice Making Area
June 2010
Page 4
SCCG50 & SCCP50 Installation and User's Manual
Water Quality
All water, including potable water supplied by municipalities, contains some impurities or minerals. Water absorbs impurities from the air as rain and/or as it flows through the ground. Some of the impurities are solid particles, these are known as suspended solids, and a fine particle filter will remove them. Other impurities are chemically bonded to the water molecules, and cannot be filtered out, these are called dissolved solids.
Ice made by this machine will have a lower mineral content than the water it was made from. This is due to the method of making ice. Purer water will freeze first in the ice making molds. The reason for this is that anything dissolved in water lowers the water’s freezing temperature. This concentrates most of the impurities in the ice machine water reservoir where they may form hard deposits known as scale. The machine dilutes the concentration of minerals by over-filling the reservoir during the harvest cycle (with the excess water flowing down the drain). s. Between 2 and 4 pints of water flow into the unit each cycle. Between 1 and 3.5 pints of that rinses the reservoir and goes down the drain.
Some impurities will inevitably remain, and will stick to the parts in the machine, and will cause malformed ice cubes. Eventually, built up mineral
scale can shorten machine life.
To keep the machine operating properly, these impurities or minerals will have to be regularly dissolved by an acid cleaning, using Scotsman Ice Machine Scale Remover. Directions for this may be found in the section under cleaning.
Filters and Treatment
In general, it is always a good idea to filter the water. A water filter, if it is of the proper type, can remove taste and odors as well as particles. Some methods of water treatment for dissolved solids include reverse osmosis, and polyphosphate feeders.
RO Water
This machine can be supplied with Reverse Osmosis water, but the water conductivity must be no less than 10 microSiemens/cm. A reverse
osmosis system should include post treatment to satisfy the R.O. water’s potential aggressiveness. Deionized water is not recommended.
Because water softeners exchange one mineral for another, softened water may not improve water conditions when used with ice machines. Where water is very hard, softened water could result in white, mushy cubes that stick together.
If in doubt about the water, contact a local point of use water specialist for recommendations on water treatment.
Installation Overview
The ice machine must:
be connected to cold, potable water
be connected to a drain
be connected to the proper power supply
be able circulate air through the vents at the
front.
Note: Do not build in so that the door is recessed.
June 2008
Page 5
Door Covering
SCCG50 & SCCP50
Installation and User's Manual
Door Panel
The ice machine is supplied without a conventional door covering so it can be decorated to the user’s preference. Scotsman offers several coverings including white, black and stainless steel. In addition, a custom built panel can be placed onto the door.
Door Panel Attachment
To attach a Scotsman supplied panel:
Note: If door swing is to be changed, it must be done before panel is attached.
The panel will be held on by 6 sheet metal screws and 2 machine screws.
1. Remove the gasket and retain for later use.
2. If the door panel is stainless steel, remove any plastic covering the stainless steel panel.
Custom Panel
A custom panel of wood or other material not exceeding 15 lb can be attached to the door. Attachment is from the ice side of the door. Holes are provided in the door for this purpose.
See instructions in information packet to create and attach a custom panel:
3. Place the panel onto the outside of the door, and secure it to the door using two machine screws, located at the left center and right center.
4. Fasten the panel to the door using the 6 sheet metal screws. In the hinge area, use the outermost screw holes.
5. Place the covers over the hinge areas, and secure each cover to the door using a sheet metal screw.
6. Insert hole plug over screw installed in step 5.
7. Return the gasket to its original position.
Hole Plug
Cover
Gasket
June 2008
Page 6
SCCG50 & SCCP50 Installation and User’s Manual
Door Panel Attachment
Use Upper Hole at the
Top
Gasket
Scotsman Door Panel
Machine
Screw
Hole Plug
Use Lower
Hole at the
Bottom
Cover
June 2008
Page 7
Door swing change
SCCG50 & SCCP50
Installation and User's Manual
Note: Prior models had separate hinge brackets and different directions to change swing.
Moving the hinges allows the door to open from either the left or right side. Change swing before attaching door panel.
To change:
1. Remove innermost screw holding each hinge to cabinet, loosen the other.
Remove
Loosen
4. Remove hole plugs or screws from unit's new hinge locations, set aside.
5. Move screws loosened in step 1 to opposite location.
6. Install screws or plugs removed in step 4 to the unit's original hinge location to fill the holes.
7. Remove the upper hinge from the door and move it to the door's opposite side, bottom location. Secure using the original screws.
Note: If door panel is attached, it must be removed to access hinge screws and to reverse handle position.
8. Remove the original lower hinge and move it to the door's opposite side, upper location. Secure using the original screws.
9. Install pocket covers and hole plugs onto door.
2. Slide door to the side and remove from cabinet.
Plug
3. Remove plug and hinge pocket covers from door.
Pocket Cover
10. Attach the door to the cabinet using the original screws.
Installation Notes
Built In Situations: If a finished floor is to be installed in the area after the ice machine has been
built in, shims the expected thickness of the floor should be installed under the unit to keep the machine level with the planned floor level.
Installations on a slab: Use a pump model and pump the water to the point of drainage. Pump models will pump 1 story (10 feet) high.
Installations over a crawl space or basement: Either gravity drain or pump model units may be used, if there is not enough room behind the machine for a drain/waste receptacle, the drain will have to be below the floor.
Note: When installed in a corner, the door swing may be limited due to handle contact with the wall
or cabinet face.
Note: There are either plugs or screws in the holes where the hinges will mount. They must be moved.
January 2012
Page 8
SCCG50 & SCCP50 Installation and User's Manual
Installation: Water & Drain
Water Supply, all models: The recommended water supply tubing is ¼ inch OD copper. Stainless steel flex or reinforced PVC tube may also be used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.
Note: Do not use self-piercing type valves.
1. Remove the front service panel.
Screw Securing
Front Service
Panel
2. Route the tubing through the right hole in the back to the inlet water solenoid valve inlet.
3. Install a compression fitting on the tubing and connect to the inlet of the solenoid at the front of the unit.
Note: Water Connection is at the FRONT of the machine. Do NOT connect to tubing at the back.
Drains
There are two types of ice machine models, one that drains by gravity and one that has an internal drain pump.
Drain Pump Model drain installation
1. Locate the coil of 3/8” ID plastic drain tubing secured to the back of the unit.
2. Route the plastic drain tube from the back of the unit to the drain connection point.
The drain connection point can be as high as 10 feet above the ice machine. The drain pump includes a check valve to prevent re-pumping water in the drain hose.
IMPORTANT NOTE: Often an air gap is required by local codes between the ice maker drain tube and the drain receptacle.
Drain Tube,
Route to
building drain
Water Inlet Tube (field supplied)
Back View, Drain Pump Model
September 2011
Page 9
Gravity Drain
SCCG50 & SCCP50
Installation and User's Manual
Caution: Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice. Gravity drain tubing must be vented, have no kinks and slope to the building drain. Air gaps are typically required by local code.
1. Place the ice machine in front of the installation
opening. Adjust leveling legs to the approximate height.
2. Remove the front service access panel and the
upper back panel.
Note: If you are connecting a gravity drain model and the drain opening has been located in the floor under the base pan according to the pre install specifications, follow steps 3 through 5 to drain the unit through the base. If not, proceed to step 6b.
3. Remove the clamp and barbed elbow and take
off the plastic cover in the base pan below the drain hose.
4. Connect a straight 5/8” barbed connector to the drain hose, securing with the clamp removed in step 3.
5. Cut an 8” piece of 5/8” ID X 7/8” OD tygon (clear plastic) tubing. Slide one end of the tube onto the outlet of the barbed connector and secure with a clamp. Leave the other end of the tube lying on the floor of the base pan until the unit is positioned over the floor drain.
6. Route the drain tube. Either a) Insert the drain tube through the base pan into the floor drain or b) Route the drain tube through the left hole in the lower back panel and connect to barbed elbow and secure with a clamp.
Note: Add a vertical vent in a horizontal drain tube to reduce internal pressure and improve drainage.
7. Reinstall the upper back panel.
8. Reinstall the service access panel. Level the unit.
Drain Hose
Drain Hose, Route to building drain
Barbed Elbow
Water Inlet Tube (field supplied)
Back View, Gravity Drain Model
June 2008
Page 10
SCCG50 & SCCP50 Installation and User's Manual
Electrical
The ice machine is supplied with a power cord. Do not remove the grounding pin from the cord’s plug. Do not use extension cords. Follow all codes. Connect the machine to its own 115 volt, 15 amp circuit.
1. If the electrical outlet for the ice maker is behind the unit, plug in the unit.
2. Position the unit in the installation opening.
3. Turn on the water supply. Make sure that the ice maker is plugged in and the power is on.
4. Slide unit into installation opening, paying careful attention to water supply and drain connections. Do not kink!
5. Pour a couple of quarts of water into the ice storage bin; on drain pump equipped machines the drain pump should start and water should pump out. Check for leaks.
6. Replace the service access panel.
7. Level the unit as needed.
Installation check list:
1. Has the unit been connected to the proper water supply?
2. Has the water supply been checked for leaks?
3. Has the unit been connected to a drain?
4. Has the drain been tested for flow and leaks?
5. Has the unit been connected to the proper electrical supply?
6. Has the unit been leveled?
7. Have all packing materials been removed from the machine?
8. Has the door covering been installed?
Initial Start Up
1. Turn on the water supply.
2. Switch on the electrical power.
3. Push and release the On/Off switch to start the machine. The Ice Making light next to the On/Off switch will glow Green.
Water will begin to flow into the unit. When the
4. reservoir is full, water will start to drain from the
machine. After a few minutes the compressor, water pump and fan motor will begin to operate and the first ice making cycle will have begun.
No adjustments are needed.
After about a half hour, ice will fall into the ice storage bin. The machine makes 24 cubes per batch. It is normal for the first batches of ice to melt, that continues until the bin has cooled. It will take 8 to 10 hours of continuous run time to fill the ice bin. When the bin is full of ice, the ice machine will shut off. It will automatically restart when the ice level falls, either from use or normal meltage.
July 2008
Page 11
Use
No special instructions are needed for use. Just take as much ice as you need, the machine will replace it. A scoop is provided, and it can be stored in the machine using the loop of tubing on the right side as a holder. That tubing is also the ice level sensor; ice will fill the storage bin until it's near to or on that tube and then the machine will shut off.
To maximize ice storage capacity, you may need to use the scoop to level the ice in the storage bin, especially within the first day or so of operation.
SCCG50 & SCCP50
Installation and User's Manual
The machine can be shut off anytime by just pushing and releasing the On/Off button. The machine will shut off at the end of the next cycle. To shut off immediately, push and hold the On/Off button in until the machine stops.
What shouldn’t be done?
Never keep anything in the ice storage bin that is not ice. Objects like wine or beer bottles are not only unsanitary, but the labels can slip off and plug up the drain.
Never allow the machine to operate without regular cleaning. The machine will last longer if it is kept clean. Regular cleaning should happen at least once per year, and preferably twice. Some water conditions will dictate even more frequent cleaning of the ice making section, and some carpets or pets will dictate more frequent cleaning of the condenser.
Normal cubes are tapered cylinders. If the cubes
are ragged and mis-shaped, mineral scale must be
removed from the ice making system
Note: The Time to Clean light will switch ON after 6 months of use. It will stay ON until the ice making system is cleaned using the process on page 13.
Noise:
The ice machine is designed for quiet operation, but will make some noise during the ice making cycle. During a freezing cycle, it is normal to hear the fan moving air and the water pump circulating water. Ice hitting the bin or ice in the bin can be heard during harvest.
If ice making noise is objectionable, an appliance grade timer can be added to the power supply. Set the timer to turn the machine off at the time(s) of day when the noise is most objectionable.
July 2018
Page 12
SCCG50 & SCCP50 Installation and User's Manual
Maintenance
There are 5 things to keep clean:
1. The outside cabinet & door.
2. The ice storage bin.
3. The condenser.
4. The ice making system.
How to clean the ice storage bin.
Over time biofilm can grow inside the drain system which can affect the ability for the drain system to
evacuate the drain water. On the pump models this
can also drive a erratic pump operation. Including the pump cycling rapidly or running all the time.
Biofilm and pump cycling issues will eventually lead to low production and standing water in the bin. To
ensure that this does not become an issue frequent bin sanitizing may be required.
The ice storage bin should be sanitized occasionally. It is usually convenient to sanitize the bin after the ice making system has been cleaned,
and the storage bin is empty.
A sanitizing solution can be made of 1 ounce of household bleach and two gallons of hot (95oF. –
115oF.) water. Use a clean cloth and wipe the interior of the ice storage bin with the sanitizing
solution, pour some of the solution down the drain.
Condenser Surface
5. The ice scoop.
How to clean the cabinet.
Wipe off any spills on the surface of the door and handle as they occur. If anything spilled on the door or gasket dries onto the surface, wash with soap and warm water to remove.
Allow to air dry.
July 2018
Page 13
How to clean the condenser and winterize.
SCCG50 & SCCP50
Installation and User's Manual
Condenser cleaning
The condenser is like the radiator on a car, it has fins and tubes that can become clogged with dirt and lint. To clean:
1. Remove the kickplate and front service panel.
2. Locate the condenser surface.
3. Vacuum the surface, removing all dust and lint.
Caution: Do not dent the fins.
Winterizing
1. Clean the ice making system.
2. Open the door and push and release the On/Off
switch to turn the machine off.
3. Turn off the water supply.
4. Drain the water reservoir by removing the rubber
cap or drain plug under the reservoir - it's near the back wall of the ice storage bin.
5. Disconnect the incoming water line at the inlet
water valve.
6. Open the door, push and release the on/off
switch to turn the machine on.
7. Blow air through the inlet water valve until water
stops flowing out; a tire pump could do the job.
8. Drain pump models should have about 1/2
gallon of RV antifreeze (propylene glycol) poured into the ice storage bin drain.
Pour Scale Remover Here
4. Return the kickplate and front service panel to their original positions. Fasten them to the cabinet using the original screws.
Note: Automotive antifreeze must NOT be used.
9. Switch off and unplug the machine.
June 2012
Page 14
SCCG50 & SCCP50 Installation and User's Manual
How to remove scale from the ice making system.
1. Scoop out all of the ice, either discard it or save it in an ice chest or cooler.
2. Press and HOLD the On/Off button in for 3 seconds until the Green light goes out.
3. Press and HOLD the both the Clean-Reset and On/Off buttons for 5 seconds. The Time to Clean light will blink on and off.
4. Pour 8 ounces of Scotsman Ice Machine Scale Remover (available from a local Scotsman Distributor or Dealer) into the ice machine reservoir.
5. Operate the machine for about ½ hour.
6. Push and release the On/Off switch. The machine will begin to flush out the cleaning solution.
7. Operate the machine for another ½ hour.
What to do before calling for service
Ice cubes are incompletely formed
Clean the ice making system
Low capacity
Check for restricted drain or standing water
in the bin
Clean the air cooled condenser fins
No ice
Check on-off switch
Check electrical breaker
If the Check Water light is flashing Red,
check water supply. The control system checks for water every 20 minutes. When the water supply is restored, the machine will automatically restart ice making.
8. Push and release the On/Off switch. The machine will stop the cleaning process.
9. Pour a gallon of hot (95oF. – 115oF.) water into the bin to flush out the drain.
10. Clean the bin liner of mineral scale by mixing some ice machine scale remover and hot water, and using that solution to scrub the scale off of the liner.
11. Rinse the liner with hot water.
12. Sanitize the bin interior.
13. Replace the ice removed in step 1.
14. Push and release the On/Off button to restart ice making.
The ice scoop should be washed regularly, wash it just like any other food container.
Erratic drain pump operation (pump models only)
Clean and sanitize bin. If the problem
continues contact a local service provider
Time to Clean light is on
Clean the ice making system.