Scotsman SCCG50M-1SS,SCCP50M-1SS Installation And User Manual

Installation and User's Manual for Outdoor Model Residential Ice Machine
Models SCCG50M-1SS and SCCP50M-1SS
SCCG50 & SCCP50 - Outdoor Model Installation and User's Manual
Introduction:
This ice machine is the result of Scotsman’s decades of experience as an industry leader in the design and manufacture of both commercial and residential ice machines.
This manual includes the information needed to install, start up and maintain the ice machine. Note any Caution or Warning indicators, as they provide notice of potential hazards. Keep this manual for future reference.
Table of Contents
Specifications .......................................... Page 2
Air flow ............................................. Page 3
Cabinet Drawing ........................................ Page 4
Water Quality .......................................... Page 5
Door swing change ....................................... Page 6
Installation: Water & Drain ................................... Page 7
Gravity Drain .......................................... Page 8
Electrical ............................................ Page 9
Use ............................................... Page 10
Maintenance .......................................... Page 11
How to clean the condenser and winterize. ........................... Page 12
How to remove scale from the ice making system. ....................... Page 13
What to do before calling for service .............................. Page 14
Outdoor Use Notice:
Keep from freezing. Severe damage will occur to the unit if left in or operated in temperatures beyond the limits listed in this manual. That damage is NOT covered by warranty.
Keep dry
Provide Shade ultraviolet radiation from the sun can potentially damage the unit's plastic components.
Water Supply should be rated for potable water and include UV protection. Copper tubing is recommended.
Back Flow Prevention
. Do not locate in low lying areas where puddles will accumulate.
: Heat gain from the sun will reduce the unit's ability to make and store ice, and
: Avoid a long run of hose or tubing exposed to the sun. Plastic water supply tubing
: The unit includes back flow prevention, no additional check valve is required.
Drainage
Operation below 65 degrees F.
: Do Not drain into swimming pool or onto grounds.
: It is normal for the ice level in the storage bin to be low when unit is used in temperatures
June 2008
Page 1
Specifications
SCCG50 & SCCP50 - Outdoor Model
Installation and User's Manual
This ice machine is designed to be used indoors, in a controlled environment or outdoors within certain limits. It can be used in a wide variety of environmental conditions, but there are limits. Use outside of the listed limitations is misuse and will void the warranty.
Air temperature limits:
The ice machine will operate adequately within the limits, but functions best in temperatures between 70 and 80 degrees F.
Minimum – 50 degrees F. (10oC)
Maximum – 100 degrees F. (38oC)
Water temperature limits:
Minimum – 40 degrees F. (4.5oC)
Maximum – 100 degrees F. (38oC)
Water pressure limits:
Options:
Drain Conversion:
A gravity drain model can be converted to a drain pump model by installing a drain pump kit. The drain pump kit consists of a drain pump, wiring harness and associated tubing. The part number is A39462-021.
Warranty Information
Warranty information is supplied separately from this manual. Refer to it for coverage. In general, the warranty covers defects in materials or workmanship and does not cover corrections of installation errors or maintenance.
Minimum – 20 psi (1.4 bar)
Maximum – 80 psi (5.5 bar)
Because the ice machine is making a food product, the water supply to the ice machine must be potable, or fit for human consumption.
Electrical voltage limits:
Minimum - 104 volts
Maximum – 126 volts
Models
There are two models, both air cooled:
SCCP50M-1SS – Pump model, stainless cabinet and door
SCCG50M-1SS – Gravity drain model, stainless cabinet and door
Dimensions
Width Depth, handle adds 1 5/8" Height
14 7/8" 22 3/4" 33 3/8" to 34 3/8"
July 2008
Page 2
SCCG50 & SCCP50 - Outdoor Model Installation and User's Manual
Air flow
The machine takes in room temperature air at the lower right front and forces warm air out the lower left front. Restricting the airflow or operating the machine in a hot or cold environment will adversely affect the ability of the ice machine to make ice.
When the door is opened, the control panel, ice making area and ice storage bin are visible. The scoop is located in a holder along the right side wall.
Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of agencies like U.L.
Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any parts and/or other components not specifically approved by Scotsman.
Scotsman reserves the right to make design changes and/or improvements at any time.
Specifications and designs are subject to change without notice.
Air IntakeWarm Air Out
Control Panel
Ice Making Area
June 2008
Page 3
Cabinet Drawing
14 7/8"
AIR IN
AIR OUT
.75
SHEET METAL DOOR FRONT
.63 MIN. CABINET DOOR
29 1/4"
1"
LEG ADJUSTMENT
(4) PLACES
33 3/8" MIN. 34 3/8" MAX.
22"
2 3/4"
4"
3 3/4"
1 1/2"
2 1/2"
3 1/4"
7 3/8"
115 V
POWER CORD
DRAIN FLEXIBLE TUBING 3/8 I.D. PUMP MODEL (INCLUDED) 5/8 I.D. GRAVITY MODEL (NOT INCLUDED)
POTABLE WATER INLET
1/4" COMPRESSION FITTING
3 7/8"
20 3/8"
FLOOR DRAIN
ACCESS HOLE
SCCG50 & SCCP50 - Outdoor Model
Installation and User's Manual
Installation Notes
Built In Situations: If a finished floor is to be installed in the area after the ice machine has been built in, shims the expected thickness of the floor should be installed under the unit to keep the machine level with the planned floor level.
Installations on a slab: Use a pump model and pump the water to the point of drainage. Pump models will pump 1 story (10 feet) high.
Installations over a crawl space or basement: Either gravity drain or pump model units may be used, if there is not enough room behind the machine for a drain/waste receptacle, the drain will have to be below the floor.
Note: When installed in a corner, the door swing may be limited due to handle contact with the wall or cabinet face.