Scotsman SCCG30 Operator’s Manual

Installation and User's Manual for Residential Ice Machine
Models SCCG30 and SCCP30
SCCG30 & SCCP30 User Manual
Introduction:
This ice machine is the result of Scotsman’s decades of experience in the design and manufacturing of both commercial and residential ice machines.
This manual includes the information needed to install, start up and maintain the ice machine. Note any Caution or Warning indicators, as they provide notice of potential hazards. Keep this manual for future reference.
Table of Contents
Specifications .......................................... Page 3
Cabinet Layout ......................................... Page 4
Air flow ............................................. Page 5
Water Quality: .......................................... Page 6
Door Panel ........................................... Page 7
Door Panel Attachment ..................................... Page 8
Door swing change ....................................... Page 9
Water .............................................. Page 10
Gravity Drain .......................................... Page 11
Electrical ............................................ Page 12
Use ............................................... Page 13
How to clean the condenser. .................................. Page 14
November 2009
Page 2
SCCG30 & SCCP30 User Manual
Specifications
This ice machine is designed to be used indoors, in a controlled environment. Use outside of the listed limitations is misuse and will void the warranty.
Air temperature limits
The ice machine will operate adequately within the limits, but functions best in temperatures between 70 and 80 degrees F.
Minimum – 50 degrees F
Maximum – 100 degrees F
Water temperature limits
Minimum – 40 degrees F.
Maximum – 100 degrees F.
Water pressure limits
Minimum – 20 psi
Maximum – 80 psi
Because the ice machine is making a food product, the water supply to the ice machine must be potable, or fit for human consumption.
Options:
Door Panel kits from Scotsman for attachment to the machine, or a custom panel can be made.
Kit Number Panel Finish Handle Finish
KDFS Stainless Steel Stainless Steel
Kickplate Extension: In some situations the leg levelers will be extended enough to become visible. A kit to extend the kickplate over the legs is KKPF.
Cabinet Stability installations it may be prudent to add a bracket that secures the back of the cabinet to a wall. That kit number is KATB.
Drain Conversion converted to a drain pump model by installing a drain pump kit. The drain pump kit consists of a drain pump, wiring harness and associated tubing. The part number is A39462-021.
Warranty Information
:Finished door panels are available
: In some free standing
: A gravity drain model can be
Electrical Voltage
Minimum - 104 volts
Maximum – 126 volts
Models
SCCP30M-1SU – Pump model, stainless cabinet
SCCG30M-1SU – Gravity drain model, stainless cabinet
Cabinet Dimensions
Width Depth, w/out door panel Depth, with door panel, handle adds 1 5/8" Height
14 7/8" 22" 22 3/4" 33 3/8" to 34 3/8"
Warranty information is supplied separately from this manual. Refer to it for coverage. In general, the warranty covers defects in materials or workmanship and does not cover corrections of installation errors or maintenance.
November 2009
Page 3
SCCG30 & SCCP30
14 7/8"
AIR IN
AIR OUT
.75
SHEET METAL DOOR FRONT
.63 MIN. CABINET DOOR
29 1/4"
1"
LEG ADJUSTMENT
(4) PLACES
33 3/8" MIN. 34 3/8" MAX.
22"
2 3/4"
4"
3 3/4"
1 1/2"
2 1/2"
3 1/4"
7 3/8"
115 V
POWER CORD
DRAIN FLEXIBLE TUBING 3/8 I.D. PUMP MODEL (INCLUDED) 5/8 I.D. GRAVITY MODEL (NOT INCLUDED)
POTABLE WATER INLET
1/4" COMPRESSION FITTING
3 7/8"
20 3/8"
FLOOR DRAIN ACCESS HOLE
User Manual
Cabinet Layout
November 2009
Page 4
SCCG30 & SCCP30 User Manual
Air flow
The machine takes in room temperature air at the lower right front and discharges warm air from the lower left front. Restricting the airflow will adversely affect the ability of the ice machine to make ice.
Warm Air Out
Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of agencies like U.L.
Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any parts and/or other components not specifically approved by Scotsman.
Scotsman reserves the right to make design changes and/or improvements at any time.
Specifications and designs are subject to change without notice.
Air Intake
November 2009
Page 5
Loading...
+ 10 hidden pages