Product data sheet
SSP1A450BDT
solid state relay-panel mount-thermal pad-input 4-32V DC, output 48-660V AC,50 A
Main
Range of product Zelio Relay
Product or component type
Provided accessory Thermal pad
Device short name SSP1
Mounting support Panel
Number of phases 1 phase
Contacts type and conifguration
[In] rated current 50 A
Solid state output type Zero voltage switching
Complementary
Control circuit voltage 4...32 V DC
Switching voltage >= 4 V DC turn-on
Response time 0.5 cycle turn-off
Input current 7...12 mA
Output voltage 48...660 V AC
Load current 0.15...50 A
Transient overvoltage 1200 V
Surge current <= 625 A for 16.6 ms
Maximum I²t for fusing 1629 A².s for 8.33 ms at 60 Hz half cycle
Co-ordination type Type 2 - 32 A miniature circuit breaker (MCB) - curve B
Leakage current <= 1 mA off-state
Voltage drop 1.15 V on-state
DV/Dt 500 V/µs off-state at maximum voltage
Power factor 0.5 with maximum load
Motor controller rating 5 hp 480 V AC
Insulation resistance 1000 MOhm at 500 V DC
Maximum capacitance 8 pF for input/output
Dielectric strength 4 kV AC for input or output to case
[Uimp] rated impulse withstand voltage 6 kV input to output
Tightening torque 2...2.2 N.m for output
Connections - terminals Ring lugs : 11.7 x 4.5 mm for output
Thermal resistance 0.45 °C/W junction to case
Thermal pad impedance 0.48 °C-in²/W at 25 psi
Dec 1, 2015
<= 1 V DC turn-off
0.5 cycle turn-on
1770 A².s for 10 ms at 50 Hz half cycle
Type 1 - 40 A miniature circuit breaker (MCB) - curve B
2 hp 240 V AC
0.75 hp 120 V AC
4 kV AC for input/output
6 kV output to case
1.5...1.7 N.m for input
Forked type tag connectors : 11.7 x 4.5 mm for output Ring lugs : 9.2 x 4 mm for input Forked type tag connectors : 9.2 x 4 mm for input Screw terminals : 0.5...8.26 mm², (AWG 20...AWG 8) without cable end for output Screw terminals : 0.2...3.3 mm², (AWG 24...AWG 12) without cable end for input Screw terminals : 0.5...5.26 mm², (AWG 20...AWG 10) with cable end for output Screw terminals : 0.2...3.3 mm², (AWG 24...AWG 12) with cable end for input
Solid state relay
1 NO
SCR output
1
LED indicator LED green for input status
IP degree of protection IP20
Product weight 89.2 g
Environment
Ambient air temperature for operation -40...80 °C
Ambient air temperature for storage -40...125 °C
Pollution degree 2
Overvoltage category III
Product certifications CE
Marking CE
Standards EN/IEC 60950-1
CSA RoHS UL REACH EAC
CSA UL EAC
UL 508 EN/IEC 62314 CSA C22.2 No 14-13
2