The information presented in this manual is not warranted by the American Power Conversion Corporation
to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed
operational and site specific development plan. Therefore, American Power Conversion Corpo ration
assumes no liability for damages, violations of codes, improper installation, system failures, or any other
problems that could arise based on the use of this Publication.
The information contained in this Publication is provided as is and has been prepared solely for the purpose
of evaluating data center design and construction. This Publication has been compiled in good faith by
American Power Conversion Corporation. However, no representation is made or warranty given, either
express or implied, as to the completeness or accuracy of the information this Publication contains.
IN NO EVENT SHALL AMERICAN POWER CO NVERSION CORPORATION, OR ANY
PARENT, AFFILIATE OR SUBSIDI A RY COMPANY OF AMERICAN POWER CON VERSION
CORPORATION OR THEIR RESPE CTI VE OFFICERS, DIRECTORS, OR EMPLOYEES BE LIABLE
FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNIT IVE , SPECIAL, OR INCIDENTAL
DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUS INESS,
CONTRACT, REVENUE, DATA, INFORMATION, OR BUSINESS INTERRUPTION) RESULTING
FROM, ARISING OUT, OR IN CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS
PUBLICATION OR THE CONTENT, EVEN IF AMERICAN POWER CONVERSION CORPORATION
HAS BEEN EXPRESSLY ADVISED OF THE POSSIBI LIT Y OF SUCH DAMAGES. AMERICAN
POWER CONVERSION CORPORATION RESERVES THE RIGHT TO MAKE CHANGES OR
UPDATES WITH RESPECT TO OR IN THE CONTENT OF THE PUBLICATION OR THE FORMAT
THEREOF AT ANY TIME WITHOUT NOTICE.
Copyright, intellectual, and all other proprietary rights in the content (including but not limited to software,
audio, video, text, and photographs) rest wi th Ameri can Power Conversion Corporation or its licensors. All
rights in the content not expressly granted herein are res er v ed. No r i ghts of an y kind are li censed or assigned
or shall otherwise pass to persons accessing this information.
This Publication shall not be for resale in whole or in part.
_____________________________________________________________________________________________
ii Smart-UPS On-Line, 208 V/240 V, 1.5kVA to 20kVA Technical Specifications 990-4768
A
Table of Contents
Technical Data .................................................................................... 3
APC Smart-UPS On-Line Model List ............................................................................ 3
120 V Output / 120 V Input .................................................................................................. 3
120 V, 208 V Output / 208 V Input ....................................................................................... 3
208 V Output / 208 V Input .................................................................................................. 4
Input Power Factor ....................................................................................................... 4
APC Smart-UPS RT 1500 VA Rack/Tower 120 V SURTA1500RMXL2U 89.0%
APC Smart-UPS RT 1500 VA 120 V SURTA1500XL 89.1%
APC Smart-UPS RT 2200 VA RM 120 V SURTA2200R MXL2U 89. 1%
APC Smart-UPS RT 2200 VA 120 V SURTA2200XL 89.1%
APC Smart-UPS RT 3000 VA Rack/Tower 120 V SURTA3000RMXL3U 85.7%
APC Smart-UPS RT 3000 VA 120 V SURTA3000XL 85.7%
Models with 120 V, 208 V Output / 208 V Input
Model SKUEfficiency
@ full load
APC Smart-UPS RT 3000 VA 208 V with 208 V to 120 V
Step-Down Transformer
APC Smart-UPS RT 3000 VA Rack-Mount 208 V with 208 V to
120 V Step-Down Transf ormer
APC Smart-UPS RT 5000 VA 208 V to 208/120 V SURTD5000R MXLP3U 90.0%
APC Smart-UPS RT Rack/To wer 5000 VA 208 V with 208 V to
120 V Step-Down Transf ormer
APC Smart-UPS RT Rack/To wer 6000 VA 208 V with 208 V to
120 V Step-Down Transf ormer
APC Smart-UPS RT 6 kVA RM 208 V with 208 V to 120 V 2 U
Step-Down Tr ansformer
APC Smart-UPS RT 6000 VA RM 208 V to 208/120 V SURTD6000R MXLP3U 90.0%
APC Smart-UPS RT Rack/To wer 8000 VA 208 V with 208 V to
120 V Step-Down Transf ormer
APC Smart-UPS RT 8 kVA RM 208 V with 208 V to 120 V 2 U
Step-Down Tr ansformer
APC Smart-UPS RT 10,000 VA 208 V with 208 V to 120 V
Step-Down Tr ansformer
APC Smart-UPS RT 10,000 VA 208 V with (2) 208 V to 120 V
Step-Down Tr ansformer
APC Smart-UPS RT 10 kVA RM 208 V with (2) 208 V to 120 V
2 U Step-Down Transforme r
APC Smart-UPS RT 15 kVA RM 208 V with 208 V to 120 V 10
kVA Step-Down Transformer
APC Smart-UPS RT 15 kVA RM 208 V with 208 V to120 V 5
kVA Step-Down Transformer
APC Smart-UPS RT 20 kVA RM 208 V with 208 V to 120 V 10
kVA Step-Down Transformer
APC Smart-UPS RT 20 kVA RM 208 V with 208 V to 120 V 5
APC Smart-UPS RT 3000 VA Rack Tower 208 V SURTD3000RMXLT3U 92.0%
APC Smart-UPS RT 3000 VA 208 V SURTD3000XLT 92.0%
APC Smart-UPS RT 5000 VA Rack Tower 208 V SURTD5000RMXLT3U 91.0%
APC Smart-UPS RT 5000 VA 208 V SURTD5000XLT 91.1%
APC Smart-UPS RT 6000 VA Rack/Tower 208 V SURT6000RMXLT3U 92.0%
APC Smart-UP S RT 6000 VA 20 8 V SURT6000XLT 92.0%
APC Smart-UPS RT 8000 VA Rack/Tower 208 V SURT8000RMXLT6U 93.0%
APC Smart-UP S RT 8000 VA 20 8 V SURT8000XLT 93.0%
APC Smart-UPS RT 10,000 VA Rack Tower 208 V SURT10000RMXLT6U 92.0%
APC Smart-UPS RT 10,000 VA 208 V SURT10000XLT 92. 0%
APC Smart-UPS RT 15 kVA RM 208 V SURT15KRMXLT 94.0%
APC Smart-UPS RT 20 kVA RM 208 V SURT20KRMXLT 94.0%