Schneider Electric Smart-UPS C 1000, Smart-UPS C 1500 Installation Guide

Installation Guide Smart-UPS
C 1000/1500 VA 120/230 Vac
2000/3000 VA 230 Vac Rack-Mount 2U

Important Safety Messages

Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed.
The following safety messages may appear throughout this manual to warn of potential hazards.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or
moderate injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage.

Safety and General Information

Read the Safety Guide supplied with this unit before installing the UPS.

• Adhere to all local and national electrical codes.
Thi
s UPS is intended for indoor use only
Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessi
• idity.
hum
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
• The battery typically lasts for two to five years. Environmental factors impact
ent temperatures, poor quality utility power, and frequent short duration discharges wi
ambi battery life.
Connect
• The batteries are heavy. Remove the batteries prior to installing the UPS in a rack.
the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.
This is a category C2 UPS product.
In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.
.
ve dust or
battery life. Elevated
ll shorten
WARNING

Inventory

All models
User Do cume ntati on
(2)
Documentation CD x 1
PowerChute Software CD x 1
(1)
(1)
(2)
(4)
(1)
Installation Guide
1000/1500/2000/3000 VA 230 Vac models
(2)
2000/3000 VA 230 Vac models
(1) (1) (1)

Product Overview

Rear Panel features

UPS input
Circuit breaker/Overload protection
Chassis ground screw
1000VA 120/230 Vac models
(2)
Outlets
USB port
Serial data port
(4)
(2)
(2)
(2)
1000 VA 120 Vac 1000 VA 230 Vac
su0644c
1500 VA 120 Vac
Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U2
1500 VA 230 Vac
su0644b
su0644d
su0644e
su0740a
UPS input
Circuit breaker/Overload protection
Chassis ground screw
Outlets
USB port
Serial data port
2000 VA 230 Vac 3000 VA 230 Vac

Front panel features

su0644 f
Online/On Battery LED
POWER ON/OFF button
120 Vac models only:
Site Wiring Fault/System Fault LED
Display interface
DISPLAY button
MUTE button
su0644 g

Installation

CAUTION
DAMAGE TO EQUIPMENT ORPERSONNEL
• The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
The combined weight
Failure to follow these instructions can result in equipment damage and minor or moderate injury
DAMAGE TO EQUIPMENT
• When installing equipment in a rack, always install peripheral equipment at the bottom of the rack.
• The UPS should always be installed above peripheral equipment in rack or stack configurations.
• Always connect the UPS to a grounded outlet.
Failure to follow these instructions can result in equipment damage
of the UPS and the battery is heavy. Remove the battery before installing the UPS in a rack.
CAUTION
Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 3

1000 VA 120/230 Vac Models

s
u
0

s
u
0
6
4
8
c
6
4
9
c

s
u
0
6
5
1
c
s
u
0
4
4
0
c

Two post rack installation


s
u
0
4
6
9
f
s u 0 4 6 9 h

Four post rack installation



Install the battery

s u 0 7 5 0 d
bu059a
s
u
0
6
2
9
d
Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U4
Secure the battery compartment door Install the bezel
s
u
0
6
5
9
c

1500 VA 120/230 Vac and 2000 VA 230 Vac Models

s
u
0
5
6
3
b

s
u
0
6
5
7
c
s
u
0
4
4
0
c
s
u
0
6
6
1
c

Two post rack installation


s u 0 4 6 9 i
s u 0 4 6 9 j

Four post rack installation


s u 0 7 5 0 e
s u 0 7 5 0 f
Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 5
Install the battery
s
u
0
629f
Connect the battery
Secure the battery compartment door Install the bezel
s
u06
58d

Connect equipment to the UPS and connect the UPS to AC power

CAUTION
RISK OF EQUIPMENT DAMAGE
• Adhere to all local and national electrical codes.
Wiring should be performed by qualified electrician.
• Always connect the UPS to a grounded outlet.
Failure to follow these instructions can result in equipment damage
s
u063
s
u0
631f
0e
© 2013 APC by Schneider Electric. APC, the APC logo, Smart-UPS and PowerChute are owned by Schneider Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective owners.
su0628b
EN 990-4495E-002
12/2013