Installation Guide Smart-UPS™
750/1000/1500/2200/3000 VA 100/120/230 Vac
Rack-Mount 2U
Important Safety Messages
Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or
maintain it. The following special messages may appear throughout this manual or on the equipment to warn of
potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Caution product safety label indicates that an electrical hazard exists
which will result in personal injury if the instructions are not followed.
The following safety messages may appear throughout this manual to warn of potential
hazards.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or
moderate injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage.
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before installing the UPS.
•
here to all national and local electrical codes.
Ad
•
Th
is UPS is intended for indoor use only.
o not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or
D
•
humidity.
•
B
e sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
•The battery typically lasts for two to five years. Environmental factors impact battery life.
tem
peratures, poor quality utility power, and frequent short duration discharges will shorten battery life.
onnect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.
C
•
•
Th
e equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
• The batteries are heavy. Remove the batteries before installing the UPS and XLBP in a rack.
s install external battery packs (XLBPs) at the bottom in rack-mount or stack configurations. The U
Alway
•
st be installed above the XLBPs.
mu
•
A
lways install peripheral equipment above the UPS in rack-mount or stack configurations.
•The UPS will recognize as many as 10 external battery packs connected to the UPS. However there is no
limit to the number of XLBPs that can be used with the UPS.
The mo
•
located on the chassis under the front bezel.
•
Always
•Recycle the package materials or save them for reuse.
del and serial numbers are located on a small, rear panel label. For some models, an additional label is
recycle used batteries.
Elevated ambient
PS

Inventory
All models 2200/3000 VA models
(1) (1) (1) (1)
120/208/230 Vac models
(1) (1) (1)
230 Vac models
(2) (1)
2200/3000 VA models
2200/3000 VA models
(1)
2200/3000 VA models
Installation
CAUTION
DAMAGE TO EQUI PMENT OR PERSONNEL
• The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
•Remove the battery before installing the UPS in a rack.
hen installing equipment in a rack, always install the UPS at the bottom of the rack with the periph
W
•
equipm
ent above the UP
• The U
Failure to follow these instructions can result in equipment damage and minor or moderate injury
PS should always be installed below peripheral equipment in stack or rack configurations.
S.
(1)
eral
Smart-UPS 750/1000/1500/2200/3000 VA 120/208/230 Vac Rack-Mount 2U2

750 VA models
su0648a
su0649a
su0651a
su0440a
0469a
bu059a
Smart-UPS 750/1000/1500/2200/3000 VA 120/208/230 Vac Rack-Mount 2U 3

1000/1500 VA models
su0657a
su0661a
su0440a
0469a
su0629a
Smart-UPS 750/1000/1500/2200/3000 VA 120/208/230 Vac Rack-Mount 2U4

2200/3000 VA models
su0654a
su0661a
su0440a
0469a
su0629a
GRAPHIC OF CONNECTING THE BATTERY
Smart-UPS 750/1000/1500/2200/3000 VA 120/208/230 Vac Rack-Mount 2U 5

Overview and Start Up
Rear p anel features
SmartSlot for optional NMC accessory card
UPS input
Circuit breaker/Overload protection
Controlled outlet group
Chassis ground screw
Outlets
EPO connector
USB port
RJ45 connector - UPS monitoring serial port
750/1000 VA 120 Vac
1500 VA 100/120 Vac 3000 VA 100/120 Vac
4a
750/1000/1500 VA 230 Vac 3000 VA 208 Vac
5a
2200 VA 120 Vac 2200/3000 VA 230 Vac
su0623a
4a
a
a
Smart-UPS 750/1000/1500/2200/3000 VA 120/208/230 Vac Rack-Mount 2U6

Electrical connections
CAUTION
DAMAGE TO EQUIPMENT OR PERSONNEL
• Adhere to all local and national electrical codes.
•Wiring should be performed by qualified electrician.
•
A
lways connect the UPS to a grounded outlet.
Failure to follow these instructions can result in equipment damage and minor or moderate injury
Plug type and connector locations may vary.
su0628a
Smart-UPS 750/1000/1500/2200/3000 VA 120/208/230 Vac Rack-Mount 2U 7

Display panel features
Online LED
UPS
ON/OFF key
On Battery LED
Site Wiring Fault LED
Replace Battery LED
Display interface
UP/DOWN arrow keys
ENTER key
ESCAPE key
APC By Schneider
Controlle d outlet groups
Some UPS models have one bank of outlets that can function as a controlled group. Use the display
interface to configure the controlled outlet features, navigate to:
Main Menu > Control > Outlet1 Control.
Select models are ENERGY STAR® qualified.
© 2014 APC by Schneider Electric. APC, the AP C logo, and Smart-UPS are owned by Schneid er
Electric Industries S.A.S., or their affiliated compani es. All other trademarks are property of their
respective owners.
EN 990-3892C
10/2014