Addendum Smart-UPS™ C 1000/1500 V A
120/230 Vac Tower/Rack-Mount 2U
Overview
This addendum provides corrections to the Operation Manuals for Smart-UPS™ C 1000/1500 VA 120/230 V
Tow er and Rack-Mount 2U mo dels.
Feature Reference Guide
Normal Mode
Function Button
Power
Power On
Power Off
Display
Status Inquiry
Mute
Enable/Disable
Fault Reset
Timing
(seconds)
0.2 Off
2On
0.2 On
2On
2Fault
UPS
State
Description
Press the POWER ON/OFF button to turn on the UPS. The
UPS will operate on AC power.
If AC power is not available the UPS will operate on
battery power.
Press the POWER ON/OFF button to turn off the UPS.
Press to verify the status or condition of the UPS. The LCD
will illuminate for 60 seconds.
Enable or disable the audible alarms. The Mute icon will
illuminate and the UPS will beep once.
After a fault has been identified, press the POWER ON/OFF
button to remove the visual indication and return to standby
status.
Configuration Mode
The Configuration mode provides additional options for the UPS. Press and hold the MUTE and MENU
buttons for 2 seconds until the system emits a short beep and the Display will flash to indicate the UPS
has entered Configuration mode.
When in Configuration mode the
MENU button forwards the display through the available options the MUTE button
toggles the configuration settings for that option.
Note: When system detects 15 seconds of no activity in Configuration mode, or when you press and
hold the
automatically exits and returns to Normal mode.
MUTE and MENU buttons for 2 seconds until the system emits a short beep, the program
Function Options Description
Self-Test
Power Quality
• 0: Default Setting
• 1: Begin Self-Test
• Good
•Fair
• Poor
When set to 1, pressing the MENU button will trigger the self test
and exit the Configuration mode.
0 is the default setting and will not initiate a self test, by pressing the
MENU button you will advance to the next configuration item.
Note: If UPS is put into Configuration Mode while the
UPS's Output Power is off, the Function of Self-Test
will not be available.
Select the quality of input utility power.
• If Good is selected, the unit will go on battery power more
provide the clean
est power supply to the connected equipment.
• If Fair is selected, the UPS is under normal operating conditions.
• If Poor is selected, the UPS will tolerate more
er and will go on battery power less often.
pow
often to
fluctuations in
Output
Voltage Setting
*
230V models only
LCD Display
Dimmer
Green Mode
Enable
Clear Event
Counter
• 220 Vac
• 230 Vac
• 240 Vac
• Load Bar Icon shows
100% = Always On.
• Load Bar Icon shows
0% = Auto Dim.
•0: Disable
•1: Enable
•NA
If unsure of the local power quality, sele ct Good.
Select the appropriate voltage of outlets when the UPS is in battery
mode.
When the LCD Display Dimmer is configured to Auto Dim the
LCD will illuminate if a button is pressed or an event occurs, then
will automatically dim after 60 seconds of no activity.
When Green Mode is enabled the UPS is operating at the most
efficient level by bypassing unused AVR components while
acceptable AC voltage is present. The UPS will enter and exit Green
mode automatically while Enabled.
Pressing the MUTE button will clear the event counter.
EN 990-4601A
03/2013