Schneider Electric Smart-UPS Installation Guide

Installation Guide Smart-UPS
X
2000/2200/3000 VA Tower/Rack-Mount 4U

Important Safety Messages

Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed.
The following safety messages may appear throughout this manual to warn of potential hazards.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or
moderate injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage.

Safety and General Information

Read the Safety Guide supplied with this unit before installing the UPS.
• Adhere to all local and national electrical codes.
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
• The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality utility power, and frequent short duration discharges will shorten battery life.
• Connect the UPS power cable directly to a wall outlet. Do not use surge pro tec to rs or extension cords.
• The batteries are heav y. Remove the batteries pr ior to installing the UPS in a rack.
• Always install external battery packs (XLBPs) at the bottom of the rack. The UPS must be installed above the XLBPs.
• The UPS display interface will re cog niz e as many as 10 external battery packs conn ected to the UPS. However there is no limit to the number of XLBPs that can be used with the UPS.
• Refer to Specifications in the Operation manual for UPS and battery weight.

Inventory

Inspect the contents upon receipt. Notify the carrier and dealer if the unit is damaged.
Included with all models
1 pair tower stabilizer brackets Use 8 flat head screws to secure tower stabilizer brackets to the UPS 1 pair rack-mount brackets Use 8 flat head screws to secure rack-mount brackets to the UPS Use 4 ornamental screws to secure rack-mount brackets to the rails Install a cage nut in the rack to secure the top hole of each rack-mount bracket in a four post rack
Included with models that have factory installed
Network Management Cards
Rail kit
1 pair support brackets Two post racks
10 screws
Included with High Voltage (HV) models
Included with model SMX3000HVT
Four post rack s 6 screws 6 washers
1 pair rail cleats 8 pan head screws
Smart-UPS X 2000/2200/3000 VA Tower/Rack-Mount 4U2

Product Overview

su0343a
Electric
su0756a
GROUP 1GROUP 2
su0757a
Front panel features
Online LEDPower On Battery LEDSite Wiring Fault LEDReplace Battery LEDLCD display screen
APC By Schneider
  
Rear panel features
SmartSlot Controll able Outlet G roup 3Chassis ground screw  External battery pack connectorUPS utility power input EPO connectorCircuit Breaker reset Serial portControllable Outlet Group 1 USB portControllable Outlet Group 2
ON/OFF button
UP/DOWN arrow keys ENTER key ESC key
2000 VA, 120 Vac Low Voltage 3000 VA, 120 Vac Low Voltage
GROUP 3
Smart-UPS X 2000/2200/3000 VA Tower/Rack-Mount 4U 3