Schneider Electric Small Building Systems Catalog

Product Catalog
Small Building Systems
VBZS - Viconics BACnet Zoning System VZ1
VZ7200F5000B Bacnet Zone Thermostat ............................................................................................................ VZ5
VZ7656B1000B Bacnet Rooftop Unit Thermostat ................................................................................................ VZ6
Digital Stand-Alone And Communicating Thermostats VT1
VWG-40 Wireless Gateway ............................................................................................................................... VT5
VT7xxxX5000/VT7xxxX5500 Series PIR Thermostats ..................................................................................... VT7
VT7200C5000 Series Zoning Thermostats ...................................................................................................... VT9
VT7200F5000 Series Zoning Thermostats ...................................................................................................... VT11
VT73xxC5000 Series Fancoil Thermostats ...................................................................................................... VT13
VT73xxF5000 Series Fancoil Thermostats ...................................................................................................... VT15
VT76xxA5000 And VT7600B5000 Series Roof Top Unit Thermostats ........................................................... VT17
VT76x5B5000 Series RoofTop Unit Thermostats With Econimizer Function ................................................... VT19
VT76xxH5000 Series Heat Pump Thermostats ................................................................................................. VT21
VT76x7B5000 Series Roof Top Unit Thermostats with Humidiy Control ........................................................ VT23
Analog Microcontroller Based Room Thermostats T1
T901 Series Electronic Thermostats ........................................................................................................................ T3
T920 Series Electronic Thermostats ........................................................................................................................ T4
T921 Series Electronic Thermostats ........................................................................................................................ T5
T926 Series Electronic Thermostats ........................................................................................................................ T6
T950 Series Electronic Thermostats ........................................................................................................................ T7
T951 Series Electronic Thermostats ........................................................................................................................ T8
Digital Microcontroller Based Humidity Controls H1
VH7200 Humidistat Series ........................................................................................................................... H3
VH20 Series Electronic Humidity Transmitters ....................................................................................................... H5
Electric Heat Controllers R1
R810 Series Solid State Relays ............................................................................................................................ R3
R820 Series SCR Power Controllers .................................................................................................................... R5
R850V Series Step Controllers ........................................................................................................................... R7
R851V Series Step Controllers ........................................................................................................................... R9
021-0247 Multi-Signal Input Electric Board ......................................................................................................... R11
C24 Ac/Dc Converter / C25 Pulse Repeater For R810 Series ............................................................................ R12
Sensors S1
Remote Temperature Sensors For VT7000 Series Thermostats ........................................................................... S3
S3000 series wall analog sensors for DDC application ........................................................................................ S6
Remote Temperature Sensors For T900 Series Thermostats ............................................................................... S7
Viconics Electronics Inc. 2013 www.viconics.com
G2
VBZS - Viconics BACnet Zoning System
VBZS - Viconics BACnet Zoning System
The Viconics VBZS BACnet® Zoning System has been specically designed to bring a simple scalable BACnet® solution to the commercial mid-market without the cost associated
with typical DDC type zoning systems.
VZ7000 SERIES
ZONING SYSTEM
The system is comprised of 2 main components: the VZ7200 pressure dependent VAV controller and the VZ7656, which serves as a master-scheduler, rooftop unit controller, static
pressure bypass controller, and status display via the local LCD user interface. Unique to the zoning market, is the VZ7200’s ability to be ordered with an on-board PIR occupancy
sensor, which provides incremental energy savings during occupied periods.
Together, these components work to provide exceptional comfort and system performance rivalling more costly and complex programmable automation at a fraction of the total installed cost.
System set-up, installation and commissioning are simplied with the elimination of separate commissioning equipment or tools. All conguration, addressing, zone-weighting
etc., are accomplished via the local LCD interface. BACnet
® object mapping is seamlessly
accomplished without the need for complex programming tools.
The scalability of the entire zoning package is it’s most unique feature. The VBZS offers owners un-paralleled “future-proof” exibility through the use of an open BACnet® protocol.
The entire system can be complimented with your choice of BACnet® controllers, graphical
workstation software available on the open market without being locked into a specic
vendor at any time. Moreover, since no other programming tools are required, mechanical service technicians can quickly and easily service the system without support from other controls vendors.
System Features Include:
» Utilizes BACnet® protocol for data exchange enabling addition of other brands of
BACnet® type components to compliment system.
» Real DDC type control functionality and accuracy. » LCD interface on both zoning and rooftop controllers. » Embedded conguration utility using simple real text conguration parameters. » Rooftop unit controller features onboard scheduling eliminating need for separate
time clock or panel.
» Rooftop unit controller features onboard static pressure controller, discharge and
return sensors, and additional monitoring input for most-used applications.
» Zoning controller features PIR motion detector capability for energy saving strategies.
VZ1
Viconics Electronics Inc. 2013
VBZS - Viconics BACnet Zoning System
VT7000 SERIES
THERMOSTATS
Viconics Electronics Inc. 2013
VZ2
VBZS - Viconics BACnet Zoning System
System Architecture
VZ7000 SERIES
ZONING SYSTEM
VZ3
Viconics Electronics Inc. 2013
VBZS - Viconics BACnet Zoning System
Specications
Thermostat power requirements: 19-30 Vac 50 or 60 Hz; 2 VA Class 2
Operating conditions: 0 °C to 50 °C ( 32 °F to 122 °F )
0% to 95% R.H. non-condensing
Storage conditions: -30 °C to 50 °C ( -22 °F to 122 °F )
0% to 95% R.H. non-condensing
Temperature sensor: Local 10 K NTC thermistor
Resolution: ± 0.1 °C ( ± 0.2 °F )
Temperature control accuracy: ± 0.5 ° C ( ± 0.9 °F ) @ 21 °C ( 70 °F ) typical calibrated
Occupied and unoccupied setpoint range cooling: 12.0 to 37.5 °C ( 54 to 100 °F )
Occupied and unoccupied setpoint range heating: 4.5 °C to 32 °C ( 40 °F to 90 °F )
Room and outdoor air temperature display -40 °C to 50 °C ( -40 °F to 122 °F )
Proportional band for room temperature range control: Cooling & Heating: 1.8°C ( 3.2°F )
Binary inputs: Dry contact across terminal BI1, BI2 & UI3 to Scom
Outputs rating: Triac output: 30 Vac, 1 Amp. Maximum, 3 Amp. in-rush
Analog: 0 to 10 Vdc into 2KΩ resistance min.
Wire gauge: 18 gauge maximum, 22 gauge recommended
Dimensions: 4.94” x 3.38” x 1.13”
Approximate shipping weight: 0.75 lb ( 0.34 kg )
Agency Approvals:
UL UL 873 (US) and CSA C22.2 No. 24 (Canada),
File E27734 with CCN
XAPX (US) and XAPX7 (Canada)
FCC Compliant to CFR 47, Part 15, Subpart B, Class A (US)
Industry Canada ICES-003 (Canada)
CE EMC Directive 89/336/EEC (Europe Union)
C-Tick AS/NZS CISPR 22 Compliant (Australia / New Zealand)
Supplier Code Number N10696
VT7000 SERIES
THERMOSTATS
Dimensions
Viconics Electronics Inc. 2013
BACnet network adapter 1/4 load transceiver optically isolated
Important Notice
All VZ7000 series controls are for use as operating controls only and are not safety devices. These instruments have undergone
rigorous tests and verications prior to
shipment to ensure proper and reliable
operation in the eld. Whenever a control
failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user / installer / electrical system designer to incorporate safety devices ( such as
relays, ow switch, thermal protections,
etc…) and/or alarm system to protect the entire system against such catastrophic failures. Tampering with the device or mis­application of the device will void the warranty.
VZ4
VZ7200F5000B BACnet Zone Thermostat
The Viconics VZ7200 PI thermostat family is specically designed for local pressure dependent VAV zone control within Viconics Zoning System product family.
The product features a backlit LCD display with dedicated function menu buttons for
simple user operation. Accurate temperature control is achieved due to the product’s PI
proportional control algorithm, which virtually eliminates temperature offset associated with traditional, differential-based thermostats.
The thermostats are used in conjunction with the Viconics VZ7656B1000B Roof Top Controller thermostat for total system operation of each zones and the RTU. A local BACnet MS_TP communication bus between all devices insures proper
VZ7000 SERIES
ZONING SYSTEM
Features
communication and smooth data exchange of all required information between the
Zones and the RTUs for proper system operation. As such, it can be seamlessly
integrated into any 3rd party BACnet® supervision system.
Fully scalable system
Can meet small and large system requirements
PI time proportioning algorithm
Increased comfort , accuracy, and energy savings
Removable terminal blocks
Facilitates wiring
Hinged PC board design
Access to mounting holes
Congurablezonesequencesofoperation
One model meet more applications
Uniquelocalcongurationsetuputility
Rapid commissioning and set-up with no laptop
required
EEPROM memory
No loss of program
Duct heater
Actuator
0-10 Vdc
4 5
9
0-10
Vdc
8 4 5
R820
SCR
Auxiliary output
Used for reheat
Pre-engineereddesign,softwareanddocumentation
Eliminates costly expenses usually associated with DDC
system
Native BACnet MS/TP solution, non-proprietary design
Supports up to 127 devices per trunk and will work with
any BACnet supervision system
Self-discoveringandself-bindingdatabase
Easy to congure and no custom programming required
PIR and Stand-by setpoints supported
Increased energy savings
Locally lockable keypad
Tamper proof, no need for thermostat guards
Auto central system RTU changeover
Achieves maximum user comfort
24Vac
Transformer
BACnet module
(next thermostat)
VZ5
-
+
VZ7200F1000B
ref
AO2
AO1
8
10 12 13 14 15
9
Local monitoring
input
BI1
11
5
4
Com
24Vac
RS
6
BO5
Scom
7
BO5
BI2
UI3
R810
Solid state
Baseboard
Viconics Electronics Inc. 2013
relay
VZ7656B1000B Bacnet Rooftop Unit Thermostat
The Viconics VZ7656B1000B thermostat is specically designed for RTU control of the Viconics Zoning System product family. The RTU thermostat is designed for single stage or multi-stage control of heating and cooling equipment such as rooftop and self-contained units used in zoning systems.
The product features a backlit LCD display with dedicated function menu buttons for simple user operation.
Accurate temperature control is achieved due to the product’s PI proportional control algorithm, which
virtually eliminates temperature offset associated with traditional, differential-based thermostats.
The thermostat also contains extra digital inputs, which can be set by the user to monitor lter status or used as a general purpose service indicator. All models contain a SPST auxiliary switch, which can be used to control lighting or disable the RTU economizer function during unoccupied periods. It also features a discharge air sensor input. Proportional static pressure logic (input and output) has been integrated onto
the thermostat to provide a complete single packaged unit for most small to medium size jobs.
Features
VT7000 SERIES
THERMOSTATS
Fully scalable system
Can meet small and large system requirements
True stand-alone system
Do not require a computer to operate
Pre-engineereddesign,softwareanddocumentation
Eliminates costly expenses usually associated with
DDC system
Native BACnet MS/TP solution, non-proprietary design
Supports up to 127 devices per trunk and will work with any BACnet supervision system
By-passdamperoutputlogicforstaticpressurecontrol
Increased comfort , accuracy, and energy savings
PI time proportioning algorithm
Increased comfort , accuracy, and energy savings
Intuitive, menu-driven programming (7 day, 2/4 events)
Can be used for all types of establishments
Fan
current
S2020E1000
Outdoor air
sensor
S2000D1000
Return
air sensor
Control
board
Bypass
damper
S2000D1000
Supply
air sensor
switch
Auxiliary output
Can be used for lighting and/or economizer override
Freezeprotection
Prevents costly freeze damage
Heating or cooling mode selection based on highest demandoraverageofvarioushighestdemands
Achieves maximum user comfort
Returnairnetworklostfunction
Guarantees comfort even if network communication is lost
Outside air heating and cooling lockout
Prevents heating and cooling overlap
SupplyandReturnairhighandlowlimits
Can be used with gas or electrical heating units
Progressiverecoveryfeature
Increases energy savings and user comfort
BACnet module
(next thermostat)
Viconics Electronics Inc. 2013
0-10 Vdc
9
Actuator
4 5
Pressure sensor
1Y22Y13G4RC5
VZ7656B1000B
BPD
AU
9
10
11
DI1
SP
12
C
13RS14
6RH7W18
Scom
15OS16
W2
DS
-
+
ref
VZ6
Digital Stand-Alone and Communicating Thermostats
Digital Stand-Alone and Communicating Thermostats
VT7000 Series communicating and non-communicating Digital PI based temperature /
humidity controllers.
THERMOSTATS
VT7000 SERIES
The VT7000 series PI based room temperature controllers have been specically designed for easy installation, commissioning and user conguration to reduce overall project
delivery costs.
End users will enjoy energy savings without sacricing rst installed cost and comfort.
All VT7000 series temperature controllers are available in both stand-alone and a host of
networked industry standard protocols such as BACnet MS/TP, Lontalk and more recently
Wireless Zigbee.
Uniquely the VT7000 series are matched with a host of accessories, including a new PIR accessory cover (see page VT5) which allows for incremental energy savings during
unoccupied periods without disrupting occupant comfort.
In this section you will be provided with information on the following products:
» Stand-Alone Digital wall mounted temperature controllers VT7000 Series. » Networked equivalents for all of the VT7000 Series. » PIR Accessory cover for the VT7200 and VT7300 Series. » Wireless network interface (Viconics Wireless Gateway)
For additional product or technical information please feel free to visit our web sites www.communicatingthermostat.com, www.viconics.com or contact our customer service department at: +1-800-563-5660,+1-514-321-5660, or email us at sales@viconics.com
VT1
Viconics Electronics Inc. 2013
Digital Stand-Alone and Communicating Thermostats
VT7000 SERIES
THERMOSTATS
Viconics Electronics Inc. 2013
VT2
Digital Stand-Alone and Communicating Thermostats
THERMOSTATS
VT7000 SERIES
Step 1 Step 2 Step 3 Step 4 Step5:Network
Five Step Model Selection Chart for VT7000 Digital Series Thermostats
Application Model Feature
Zone control,
Hot/Cool air dampers, valves, changeover capability, reheat contact output. No Fan control with this model.
with Humidity
sensor
2/4 pipe
fancoilcontrol
Hot/Chill water valves, 1, 2 or 3 speed fan, changeover capability, reheat contact output.
Commercial
Hotels/
Lodging
without Humidity
sensor
with Humidity
sensor
without Humidity
sensor
Primary Outputs
Floating 1H/1C VT7200C5000 VT7200C5000
Analog 1H/1C VT7200F5000 VT7200F5000B VT7200F5000E VT7200F5000W
Floating 1H/1C VT7350C5000 VT7350C5000B VT7350C5000E VT7350C5000W
Analog 1H/1C VT7350F5000 VT7350F5000B VT7350F5000E VT7350F5000W
ON/OFF 1H/1C VT7300A5000 VT7300A5000B VT7300A5000E VT7300A5000W
Floating 1H/1C VT7300C5000 VT7300C5000B VT7300C5000E VT7300C5000W
Analog 1H/1C VT7300F5000 VT7300F5000B VT7300F5000E VT7300F5000W
Floating 1H/1C VT7355C5000 VT7355C5000B VT7355C5000E VT7355C5000W
Analog 1H/1C VT7355F5000 VT7355F5000B VT7355F5000E VT7355F5000W
ON/OFF 1H/1C VT7305A5000 VT7305A5000B VT7305A5000E VT7305A5000W
Floating 1H/1C VT7305C5000 VT7305C5000B VT7305C5000E VT7305C5000W
Analog 1H/1C VT7305F5000 VT7305F5000B VT7305F5000E VT7305F5000W
Standalone
BACnet (MS/TP)
Echelon
Wireless (ZigBee)
B VT7200C5000E VT7200C5000W
Single stage ON/OFF 1H/1C VT7600A5000 VT7600A5000B VT7600A5000E VT7600A5000W
Rooftopunit
control, staged heat and cool, single speed fan, frost protection, progressive recovery.
Heat pump control
No schedule
Schedule
No schedule ON/OFF 3H/2C VT7600H5000 VT7600H5000B VT7600H5000E VT7600H5000W
Schedule ON/OFF 3H/2C VT7652H5000 VT7652H5000B VT7652H5000E VT7652H5000W
Multi-stage ON/OFF 2H/2C VT7600B5000 VT7600B5000B VT7600B5000E VT7600B5000W
Economizer ON/OFF 2H/2C VT7605B5000 VT7605B5000B VT7605B5000E VT7605B5000W
Humidity control ON/OFF 2H/2C VT7607B5000 VT7607B5000B VT7607B5000E VT7607B5000W
Single stage ON/OFF 1H/1C VT7652A5000 VT7652A5000B VT7652A5000E VT7652A5000W
Multi-stage ON/OFF 2H/2C VT7652B5000 VT7652B5000B VT7652B5000E VT7652B5000W
Economizer ON/OFF 2H/2C VT7656B5000 VT7656B5000B VT7656B5000E VT7656B5000W
Humidity control ON/OFF 2H/2C VT7657B5000 VT7657B5000B VT7657B5000E VT7657B5000W
For factory assembled PIR cover, use the same part numbers replacing 5000 by 5500 (ex: VT7200C5500E)
VT3
Viconics Electronics Inc. 2013
Digital Stand-Alone and Communicating Thermostats
Specications
Thermostat power requirements: 19-30 Vac 50 or 60 Hz; 2 VA Class 2
Operating conditions: 0 °C to 50 °C ( 32 °F to 122 °F )
0% to 95% R.H. non-condensing
Storage conditions: -30 °C to 50 °C ( -22 °F to 122 °F )
0% to 95% R.H. non-condensing
Temperature sensor: Local 10 K NTC thermistor
Resolution: ± 0.1 °C ( ± 0.2 °F )
Control accuracy: Temp: ± 0.5 ° C ( ± 0.9 °F ) @ 21 °C ( 70 °F ) typical calibrated
Humidity: ± 5% RH from 20 to 0% RH at 50 to 90°F (10 to 32 °C)
Occupied and unoccupied setpoint range cooling: 12.0 to 37.5 °C ( 54 to 100 °F )
Occupied and unoccupied setpoint range heating: 4.5 °C to 32 °C ( 40 °F to 90 °F )
Room and outdoor air temperature display -40 °C to 50 °C ( -40 °F to 122 °F )
Proportional band for room temperature range control: Cooling & Heating: 1.8°C ( 3.2°F )
Binary inputs: Dry contact across terminal BI1, BI2 & UI3 to Scom
Outputs rating: Triac output: 30 Vac, 1 Amp. Maximum, 3 Amp. in-rush
Analog: 0 to 10 Vdc into 2KΩ resistance min.
Economizer analog output rating: 0 to 10 Vdc into 2Kohms resistance min.
Economizer analog output accuracy: ± 3% typical
Wire gauge: 18 gauge maximum, 22 gauge recommended
Dimensions: 4.94” x 3.38” x 1.13”
Approximate shipping weight: 0.75 lb ( 0.34 kg )
VT7000 SERIES
THERMOSTATS
Dimensions
Agency Approvals:
UL UL 873 (US) and CSA C22.2 No. 24 (Canada),
File E27734 with CCN
XAPX (US) and XAPX7 (Canada)
FCC Compliant to CFR 47, Part 15, Subpart B, Class A (US)
Industry Canada ICES-003 (Canada)
CE EMC Directive 89/336/EEC (Europe Union)
C-Tick AS/NZS CISPR 22 Compliant (Australia / New Zealand)
Supplier Code Number N10696
Important Notice
All VT7000 series controls are for use as operating controls only and are not safety devices. These instruments have undergone
rigorous tests and verications prior to
shipment to ensure proper and reliable
operation in the eld. Whenever a control
failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user / installer / electrical system designer to incorporate safety devices ( such as
relays, ow switch, thermal protections,
etc…) and/or alarm system to protect the entire system against such catastrophic failures. Tampering with the device or mis­application of the device will void the warranty.
Viconics Electronics Inc. 2013
VT4
VWG-40 Wireless Gateway
THERMOSTATS
VT7000 SERIES
VWG-40-MSTP-1000 Viconics BACnet RS485 MS-TP wireless gateway
* Available Q2 2009
NEW!!
Available Models
MODEL DESCRIPTION
VWG-40-IP-1000 Viconics BACnet over IP wireless gateway
VWG-40-LON-1000* Viconics LON wireless gateway
The VWG-40 and related wireless thermostats are targeted to retrot applications where the addition of communicating eld bus wiring within the building space is prohibitive. The Gateway and Communicating Thermostats with wireless eld bus encourages the use of existing wiring utilized by existing electronic thermostat type controls.
The VWG-40-XX-1000 when utilized in conjunction with the VT7xxxXxxxxW series wireless thermostats will offer the integrator simple BACnet IP or BACnet MS/TP Objects or Lontalk
SNVT’s interface to integrate over standard building automation systems using familiar
integration toolsets. Up to 30 thermostats are supported by a single gateway.
Features & Benets
Features Benets
Supports up-to 40 thermostats per gateway Satisfy most project requirements
BACnet/Lon models available Integrates to a wide variety of industry automation systems
Auto-discovery of network nodes Simple set-up and operation reduces installation cost.
Wireless network interface Eliminates need for communication wiring
Thermostat operate absent from network connection Fully redundant automation with minimal downtime
Uses existing equipment wiring to power thermostat No batteries to service
Model Accessory
VWG-APP-1000
VWG-WA-1000 Replacement antenna for gateway mounted antenna setup
VWG-RA-1000
VWG-PS-AC24-1000 24VAC to 16VDC power supply for VWG-40
Interface software for VWG conguration and set-up. Operates under Windows XP ™. Uses a LAN crossover IP connection for initial set-up
Remote antenna for gateway when the gateway is installed inside a metal cabinet or
when remote antennal mounting is required by physical installation
VWG-PSNA-AC120-1000 120VAC North American wall adapter for VWG-40
VWG-PSEU-AC120-1000 120VAC European wall adapter for VWG-40
VT5
Viconics Electronics Inc. 2013
VWG-40 Wireless Gateway
Specications And Dimensions
Platform
• PowerPC 405EP 250 MHz processor
• 64MB SDRAM & 64 MB Serial Flash
• 128 KB Static RAM
• Battery Backup - 5 minutes typical - shutdown begins
within 10 seconds
• Real-time clock - 3 month backup max via battery
Operating System
• QNX RTOS
• IBM J9 JVM Java Virtual Machine
• NiagaraAX
Communications
• 2 Ethernet Ports – 10/100 Mbps (RJ-45 Connectors)
• 1 RS 232 Port (9 pin D-shell connector)
• 1 RS 485 non isolated port (3 Screw Connector on
base board)
PowerSupply
• VWG-PS-DC 24 Vac to 15 Vdc panel mounted power
supply for VWG
• VWG-PS-AC 120 Vac to 15 Vdc power supply for
VWG with cord
Environment
• Operating temperature range: 0° to 50°C (32°F to 122°F)
• Storage Temperature range: 0° to 60°C (32°F to 140°F)
• Relative humidity range: 5% to 95%, non-condensing
Agency Listings
• UL 916, C-UL listed to Canadian Standards Association
• (CSA) C22.2 No. 205-M1983 “Signal Equipment”
• CE, FCC part 15 Class A
• C-tick (Australia)
VT7000 SERIES
THERMOSTATS
Chassis
• Construction: Plastic, din rail or screw mount chassis,
plastic cover
• Cooling: Internal air convection
• Dimensions: check graphic
Viconics Electronics Inc. 2013
VT6
VT7000X5000/VT7000X5500 Series PIR Ready Thermostats
The VT7000X5000 & VT7000X5500 PI thermostat family is specically designed for advanced
occupancy applications. These thermostats are equipped with advanced active occupancy logic, which will automatically switch occupancy levels from occupied to stand-by and unoccupied as required by local activity being present or not. This advanced occupancy functionality provides
advantageous energy savings during occupied hours without sacricing occupant comfort.
THERMOSTATS
VT7000 SERIES
Available Models
All VT7000 series thermostats are available as VI-PIR cover ready models (VI-PIR cover could be added when needed) or factory assembled (VI-PIR cover factory installed).
Thermostats compatible with VI-PIR covers use the following part number assignments: VT7xxxxX5000(X). The 5 indicates that the thermostat’s base has the necessary onboard polarized PIR connector and functionality added. Factory assembled PIR thermostats (VI-PIR cover included) use the following part number assignments: VT7xxxxX5500(X). The 55 indicates that the thermostat comes with factory installed VI-PIR cover.
For example, a VI-PIR cover ready model would have the following model number: VT7300F5000B and a PIR model with factory installed VI-PIR cover would have this model number VT7300F5500B
VI-PIR Cover Ready Factory Assembled PIR Model
VT7200X5000 VT7200X5500 VT73xxX5000 VT73xxX5500 VT76xxX5000 VT76xxX5500
At the end of the model number add B for BACnet models, E for Echelon models or W for ZigBee wireless models. Ex: VT76xxX5000B, VT76xxX5000E, VT76xxX5000W.
Conguration Parameters Specic to PIR Models
Parameter name Function Range/Options
St-By TM
Unocc TM
St-By HT
St-By CL
Stand-by Timer value. Time delay between the moment where the PIR
cover detected the last movement in the area and the time which the thermostat stand-by mode and setpoints become active.
Unoccupied Timer value. Time delay between the moment where the
thermostat toggles to stand-by mode and the time which the thermostat unoccupied mode and setpoints become active. The factory value or 0.0 hours: Setting this parameter to its default value of 0.0 hours disables the unoccupied timer. This prevents the thermostat
to drift from stand-by mode to unoccupied mode when PIR functions are
used
Stand-by heating setpoint. The value of this parameter should reside between the occupied and unoccupied heating setpoints and make sure that the difference between the stand-by and occupied value can be
recovered in a timely fashion when movement is detected in the zone.
Stand-by cooling setpoint. The value of this parameter should reside between the occupied and unoccupied cooling setpoints and make sure that the difference between the stand-by and occupied value can be
recovered in a timely fashion when movement is detected in the zone.
0.5 to 24 hours in 0.5hr increments
0.0 to 24 hours in 0.5hr increments
40 to 90 °F ( 4.5 to 32.0 °C )
54 to 100 °F ( 12.0 to 37.5 °C )
VT7
Viconics Electronics Inc. 2013
New: VT7xxxX5000/VT7xxxX5500 Series PIR Ready Thermostats
Features
PI time proportioning algorithm
Maximizesenergysavings(10-30%)
CanbeutilizedinconjunctionwithViconicsscheduled(7day)oropennetworkprotocolsuchasBACnetMS/TP,
Echelon, or Zigbee thermostats
CompatiblewithVT7200andVT7300seriesthermostats
Pre-programmed, single device in a compact esthetically pleasing styling
Potentialforcontrollinglocallightingsystemsbaseduponoccupancy
Factoryoreldinstalledversionsavailable
AdiagnosticLEDinsidethePIRfacilitatescommissioningbyprovidingvisualconrmationofmotionduringthe rst30minutesofservice
Extendsequipmentlifespan
Applicationsincludehospitality,education,ofceforrooftopterminalequipment
Typical Detection Pattern for VI-PIR Lens
Horizontal
(typical)
Angle
Vertical Angle
(typical)
VT7000 SERIES
THERMOSTATS
Energy Savings
The VI-PIR can maximize your
energy saving from 10-30% by relaxing temperature set points
in unoccupied zones during
scheduled periods.
Viconics Electronics Inc. 2013
85 80
75 70
65 60 55
50 45
40 35
30 25
Ener gy U sa ge ( KWh)
20
15 10
5 0
0 2 4 6 8 10 12 14 16 18 20 22 24
Typical Consumption PIR Therm ostat Consumption Savings
Typical Savingsof10-30%
TimeofDay(EST)
50%
40%
Saving Percentage
30%
20%
10%
0%
VT8
VT7200C5000 Series Zoning Thermostats
The VT7200C5000 series features a backlit LCD display with dedicated function menu keys for simple operation. Accurate temperature control is achieved due to the
product’s PI proportional control algorithm. Models are available for 3 point oating
(can be set for On/Off). In addition, remote room sensing is available. All models contain an auxiliary contact that can be used to control lighting or auxiliary reheat. All
devices are also available with Echelon, BACnet MS-TP or wireless network adapter.
THERMOSTATS
VT7000 SERIES
Available Models
MODEL
2 ON / OFF OR
FLOATING OUTPUTS
AUX
OUTPUT
BACNET MODEL ECHELON MODEL WIRELESS MODEL
VT7200C5000 VT7200C5000B VT7200C5000E VT7200C5000W
Replace 5000 by 5500 for factory installed PIR cover.
Conguration Parameters
Parameter name Function Range/Options
PswrdSet Sets access password to the conguration menu 0 to 1000
Com Address* Sets the Com address of the thermostat 0 to 254
PAN ID** Sets the PAN ID of the thermostat 0 to 500
Channel** Sets the channel of the thermostat 10 to 26
Get From** Chooses thermostat to import conguration from 0 to 254
BI1 Denes the use of binary input BI1 None, Rem NSB, Motion NO, Motion NC, Window
BI2 Denes the use of binary input BI2 None, Door Dry, RemOVR, Filter, Service
UI3 Denes the use of universal input BI3 None, COC/NH, COC/NC, COS, SS
MenuScro Used to activate or deactivate menu scroll ON or OFF
C or F Sets temperature units °F, °C
Lockout Sets the keypad lockout level 0, 1, 4, 5
Out1Conf Denes the type of operation for output #1 2.0 pipe or 4.0 pipe
CntrlTyp Denes the type of control outputs Floating, On/Off
SeqOpera Denes the sequence of operation of thermostat 0, 1, 2, 3, 4, 5
St-By TM Sets the stand-by Timer value 0.5 to 24 hours (in 0.5hr increments)
Unocc TM Sets the unoccupied Timer value 0.0 to 24 hours (in 0.5hr increments)
St-By HT Sets the stand-by heating setpoint 40 to 90 °F ( 4.5 to 32.0 °C )
St-By CL Sets the stand-by cooling setpoint 54 to 100 °F ( 12.0 to 37.5 °C )
Unocc HT Sets the unoccupied heating setpoint 40 to 90 °F ( 4.5 to 32.0 °C )
Unocc CL Sets the unoccupied cooling setpoint 54 to 100 °F ( 12.0 to 37.5 °C )
heat max Sets the maximum heating setpoint limit 40 to 90 °F ( 4.5 to 32.0 °C )
cool min Sets the minimum cooling setpoint limit 54 to 100 °F ( 12.0 to 37.5 °C )
Pband Adjust the proportional band used by the PI control loop 2 to 10 °F ( 0.6 to 5.6 °C )
Set Type Enables temporary setpoints feature Permanent, Temporary
TOccTime Sets the temporary occupancy time when overriding 0 to 24 hours (in 1 hour increments)
DoorTime Forces Unoccupied mode if door stays open more than 1 to 10 minutes (in 1 minute increments)
deadband Denes the minimum deadband 2, 3, 4, 5 °F
cal RS Room air temperature sensor calibration ± 5.0 °F
aux cont Sets Auxiliary contact function to occupancy or reheat 0 (reheat); 1, 2 (occupancy); 5 (network)
FL time Sets stroke time of oating actuator 0.5 to 9 minutes
cph Sets the number of cycles per hour for On/Off outputs 3, 4, 5, 6, 7, 8
Reheat Sets the time base for the reheat output if used 0 (4 cph) or 1 (PWM 10 seconds)
UI3 dis Displays supply or changeover temperature when UI3 is congured as analog input (SS or COS)
Note:toaccesstheCongurationMenupressandholdthe“Override”keyfor8seconds
(*) Only available in Wireless (VT7200X5000W) and BACnet (VT7200X5000B) models (**) Only available in Wireless (VT7200X5000W) models
VT9
Viconics Electronics Inc. 2013
VT7200C5000 Series Zoning Thermostats
Features
Advancedoccupancyfunctions
Through the network or smart local occupancy
sensing
3congurableinputs
Adds functionality
Pre-conguredsequencesofoperation
One model meets more applications
reduces project delivery cost
Uniquelocalcongurationutility
Minimizes parameter tampering
Typical 4 Pipe Application
- Heating valve
- Cooling valve
- Electric duct heater
Cooling
valve
11
10 4 4
Lockable keypad
Tamper proof, no need for thermostat guards
Availableforanalogcontrol(seeVT7200F1000pageVT11)
Meet advanced applications requirements
Auxiliary output
Can be used for lighting or reheat
Availablewithvariousopenindustrystandards
communication adapters
Adds network integration functionality for additional savings
Viconics
R800
series
SSR
Triacs
4 7
24 Vac ON/OFF relay (4 C.P.H.) or 24 Vac PWM ( 10 seconds )
4
5
24V
Com.
6
BO57BO58BO3
Bi1
Ui315Bi214Scom
9 8
Heating
valve
24Vac
Transformer
BO111BO2
BO4
VT7000 SERIES
THERMOSTATS
Typical 2 Pipe Application
- Heating/Cooling valve
- Electric duct heater
- Changeover Sensor
See Page VT4 for
Dimensions and
specications
Changeover
sensor
15 13
Heating/
cooling
valve
11 10 4
10
9
24Vac
Transformer
BO111BO2
BO4
10
9
13RS12
VT7200C5000
Viconics
R800
series
SSR
Triacs
4 7
24 Vac ON/OFF relay (4 C.P.H.) or 24 Vac PWM ( 10 seconds )
4
5
24V
Com.
6
BO57BO58BO3
Bi1
13RS12
16
VT7200C5000
Ui315Bi214Scom
16
Model no. Accessory
S3010W1000 Wall mounted temperature sensor
S3020W1000
Wall mounted temperature sensor with override key and occupancy status LED
S2060A1000 Averaging temperature sensor
S2000D1000 Duct mounted temperature sensor
Viconics Electronics Inc. 2013
Model no. Accessory
S1010D1000
Low cost duct mounted changeover temperature sensor
S1010E1000 Capsule type general purpose temperature sensor
COV-BC Thermostat blind cover
See page S3-S4-S5 in Sensors section for details
VT10
VT7200F5000 Series Zoning Thermostats
The VT7200F5000 series features a backlit LCD display with dedicated function menu keys for simple operation. Accurate temperature control is achieved due to the
product’s PI proportional control algorithm. Models are available for analog 0-10Vdc
control. In addition remote room sensing is available. All models contain an auxiliary contact that can be used to control lighting or auxiliary reheat. All devices are also
available with Echelon, BACnet MS-TP or wireless network adapter.
THERMOSTATS
VT7000 SERIES
Available Models
MODEL
2 ANALOG
OUTPUTS
AUX
OUTPUT
BACNET MODEL ECHELON MODEL WIRELESS MODEL
VT7200F5000 VT7200F5000B VT7200F5000E VT7200F5000W
Replace 5000 by 5500 for factory installed PIR cover.
Conguration Parameters
Parameter name Function Range/Options
PswrdSet Sets access password to the conguration menu 0 to 1000
Com Addr* Sets the Com address of the thermostat 0 to 254
PAN ID** Sets the PAN ID of the thermostat 0 to 500
Channel** Sets the channel of the thermostat 10 to 26
Get From** Chooses thermostat to import conguration from 0 to 254
BI1 Denes the use of binary input BI1 None, Rem NSB, Motion NO, Motion NC, Window
BI2 Denes the use of binary input BI2 None, Door Dry, RemOVR, Filter, Service
UI3 Denes the use of universal input BI3 None, COC/NH, COC/NC, COS, SS
MenuScro Used to activate or deactivate menu scroll ON or OFF
C or F Sets temperature units °F, °C
Lockout Sets the keypad lockout level 0, 1, 4, 5
Out1Conf Denes the type of operation for output #1 2.0 pipe or 4.0 pipe
SeqOpera Denes the sequence of operation of thermostat 0, 1, 2, 3, 4, 5
St-By TM Sets the stand-by Timer value 0.5 to 24 hours (in 0.5hr increments)
Unocc TM Sets the unoccupied Timer value 0.0 to 24 hours (in 0.5hr increments)
St-By HT Sets the stand-by heating setpoint 40 to 90 °F ( 4.5 to 32.0 °C )
St-By CL Sets the stand-by cooling setpoint 54 to 100 °F ( 12.0 to 37.5 °C )
Unocc HT Sets the unoccupied heating setpoint 40 to 90 °F ( 4.5 to 32.0 °C )
Unocc CL Sets the unoccupied cooling setpoint 54 to 100 °F ( 12.0 to 37.5 °C )
heat max Sets the maximum heating setpoint limit 40 to 90 °F ( 4.5 to 32.0 °C )
cool min Sets the minimum cooling setpoint limit 54 to 100 °F ( 12.0 to 37.5 °C )
Pband Adjust the proportional band used by the PI control loop 2 to 10 °F ( 0.6 to 5.6 °C )
Set Type Enables temporary setpoints feature Permanent, Temporary
TOccTime Sets the temporary occupancy time when overriding 0 to 24 hours (in 1 hour increments)
DoorTime Forces Unoccupied mode if door stays open more than: 1 to 10 minutes (in 1 minute increments)
deadband Denes the minimum deadband 2, 3, 4, 5 °F
cal RS Room air temperature sensor calibration ± 5.0 °F
aux cont Sets Auxiliary contact function to occupancy or reheat 0 (reheat); 1, 2 (occupancy); 5 (network)
cph Sets the number of cycles per hour for On/Off outputs 3, 4, 5, 6, 7, 8
RA/DA Changes the action of the analog outputs RA or DA
Reheat Sets the time base for the reheat output if used 0 (4 cph) or 1 (PWM 10 seconds)
UI3 dis Displays supply or changeover temperature when UI3 is congured as analog input (SS or COS)
Note:toaccesstheCongurationMenupressandholdthe“Override”keyfor8seconds
* Only available in Wireless (VT7200X5000W) and BACnet (VT7200X5000B) models ** Only available in Wireless (VT7200X5000W) models
VT11
Viconics Electronics Inc. 2013
VT7200F5000 Series Zoning Thermostats
Features
Advancedoccupancyfunctions
Through the network or smart local occupancy
sensing
3congurableinputs
Adds functionality
Pre-conguredsequencesofoperation
One model meets more applications
reduces project delivery cost
Uniquelocalcongurationutility
Minimizes parameter tampering
Cooling
valve
Typical 4 Pipe Application
- Heating valve
- Cooling valve
- Electric duct heater
0-10
Vdc
9
5
4
Lockable keypad
Tamper proof, no need for thermostat guards
Availablefor24VacOn/Offoroatingcontrol(p.VT9)
Meet advanced applications requirements
Auxiliary output
Can be used for lighting or reheat
Availablewithvariousopenindustrystandards
communication adapters
Adds network integration functionality for additional savings
Viconics
R800
series
SSR
Triacs
7
4
24 Vac ON/OFF relay (4 C.P.H.) or 24 Vac PWM ( 10 sec onds )
0-10
Vdc
Heating
valve
24Vac
Transformer
5
4
8
VT7000 SERIES
THERMOSTATS
Typical 2 Pipe Application
- Heating/Cooling valve
- Electric duct heater
- Changeover Sensor
See Page VT4 for
Dimensions and
specications
Changeover
sensor
13
15
0-10 Vdc
9
Heating/
cooling
vavle
4
5
4
24V
Com.
7
6
BO5
BO5
VT7200F5000
AO2
AO1
Bi1
RS
Scom
Bi2
Ui3
8
10
9
11
12
13
14
15
Viconics
R800
series
SSR
Triacs
7
4
24Vac
Transformer
5
VT7200F5000
AO2
AO1
8
10
9
24 Vac ON/OFF relay (4 C.P.H.) or 24 Vac PWM ( 10 seconds )
4
5
24V
Com.
7
6
BO5
BO5
Bi1
RS
Scom
Bi2
11
12
13
14
Ui3
15
Model no. Accessory
S3010W1000 Wall mounted temperature sensor
S3020W1000
Wall mounted temperature sensor with override key and occupancy status LED
S2060A1000 Averaging temperature sensor
S2000D1000 Duct mounted temperature sensor
Viconics Electronics Inc. 2013
Model no. Accessory
S1010D1000
Low cost duct mounted changeover temperature sensor
S1010E1000 Capsule type general purpose temperature sensor
COV-BC Thermostat blind cover
See page S3-S4-S5 in Sensors section for details
VT12
VT73xxC5000 Series Fancoil thermostats
The VT73xxC5000 PI thermostat family is specically designed for fancoil control. The
product features a backlit LCD display with dedicated function menu buttons for simple
operation. Accurate temperature control is achieved due to the product’s PI proportional
control algorithm, which virtually eliminates temperature offset associated with traditional, differential-based thermostats. All models can control three, two or single fan speeds. Three additional inputs are also provided for various functions. All models
feature congurable System and Fan button functions to meet all possible applications.
All models contain an auxiliary contact that can be used to control lighting or auxiliary
reheat. All devices are also available with Echelon or BACnet MS-TP network adapter.
THERMOSTATS
VT7000 SERIES
VT13
MODEL
VT7300A5000 Commercial
VT7305A5000 Hotels/Lodging
VT7300C5000 Commercial
VT7350C5000 Commercial
VT7305C5000 Hotels/Lodging
VT7355C5000 Hotels/Lodging
Add B for BACnet models, E for Echelon models or W for ZigBee wireless models. Ex: VT73xxX5000B, VT73xxX5000E,VT73xxX5000W. Replace 5000 by 5500 for factory installed PIR cover.
Parameter name Function Range/Options
PswrdSet Sets access password to the conguration menu 0 to 1000 Com Addr* Sets the Com address of the thermostat 0 to 254 PAN ID** Sets the PAN ID of the thermostat 0 to 500 Channel** Sets the channel of the thermostat 10 to 26 Get From** Chooses thermostat to import conguration from 0 to 254 BI1 Denes the use of binary input BI1 None, Rem NSB, Motion NO or NC, Window BI2 Denes the use of binary input BI2 None, Door Dry, RemOVR, Filter, Service UI3 Denes the use of universal input UI3 None, COC/NH, COC/NC, COS, SS MenuScro Used to activate or deactivate menu scroll ON or OFF AutoMode Enables auto function for the mode button ON or OFF C or F Sets temperature units °F, °C %RH disp*** Enables %RH to be displayed below room temperature ON or OFF Lockout Sets the keypad lockout level 0, 1, 2, 3, 4, 5 Pipe No Denes number of pipes and limits sequences allowed 2.0 pipe or 4.0 pipe CntrlTyp Denes functioning of main outputs ON/OFF or Tri-State Floating SeqOpera Denes the sequence of operation of thermostat 0, 1, 2, 3, 4, 5 Fan Menu Denes sequence of fan operation 0, 1, 2, 3, 4 DEHumiLCK*** Enables or disables dehumidication ON, OFF %RH set*** Dehumidication setpoint 30 to 95% DehuHyst*** Denes humidity control hysterisys 2 to 20% DehuCool*** Maximum cooling valve position when dehumidication is enabled 20 to 100% St-By TM Sets the stand-by Timer value 0.5 to 24 hours (in 0.5hr increments) Unocc TM Sets the unoccupied Timer value 0.0 to 24 hours (in 0.5hr increments) St-By HT Sets the stand-by heating setpoint 40 to 90 °F ( 4.5 to 32.0 °C ) St-By CL Sets the stand-by cooling setpoint 54 to 100 °F ( 12.0 to 37.5 °C )
Unocc HT Sets the unoccupied heating setpoint 40 to 90 °F ( 4.5 to 32.0 °C ) Unocc CL Sets the unoccupied cooling setpoint 54 to 100 °F ( 12.0 to 37.5 °C )
heat max Sets the maximum heating setpoint limit 40 to 90 °F ( 4.5 to 32.0 °C ) cool min Sets the minimum cooling setpoint limit 54 to 100 °F ( 12.0 to 37.5 °C ) Pband Adjust the proportional band used by the PI control loop 2 to 10 °F ( 0.6 to 5.6 °C ) Set Type Enables temporary setpoints feature Permnent, Temporar SptFunc Sets the local setpoint interface for the user Dual Stp or AttchStp TOccTime Sets the temporary occupancy time when overriding 0 to 24 hours (in 1 hour increments) DoorTime Forces Unoccupied mode if door stays open more than: 1 to 10 minutes (in 1 minute increments) deadband Denes the minimum deadband 2, 3, 4, 5 °F
cal RS Room air temperature sensor calibration ± 5.0 °F cal RH Room relative humidity sensor calibration ± 15.0 %
aux cont Sets Auxiliary contact function and conguration 0 (reheat); 1, 2, 3, 4 (occupancy); 5 (network) Auto Fan Auto Speed Fan Mode operation for Fan Sequences 2 and 3 AS or AS AD FL time Sets stroke time of oating actuator 0.5 to 9 minutes (in 0.5 minute increments) cph Sets the number of cycles per hour for On/Off outputs 3, 4, 5, 6, 7, 8
Reheat Sets the time base for the reheat output if used 0 (4 CPH) or 1 (PWM 10 seconds) UI3 dis Displays supply or changeover temperature when UI3 is congured as analog input (SS or COS)
* Only available in Wireless (VT73xxX5000W) and BACnet (VT73xxX5000B) models ** Only available in Wireless (VT73xxX5000W) models
***OnlyavailableinmodelswithRHSensor(VT7350C5000X,VT7355C5000X)
2 ON/OFF
OUTPUTS
2 ON/OFF or
FLOATING OUTPUTS
HUMIDITY SENSOR
FOR DEHUM.
AUX.
OUTPUT
APPLICATION
(CENTER KEY OPTION)
Viconics Electronics Inc. 2013
Loading...