SARGENT Profile Series v.G1.5 User Manual

Keypad Programming Instructions
for the Profile Series LK and v.G1 Locks
© SARGENT Manufacturing Company
A7716B
www.sargentlock.com
For installation assistance, contact SARGENT at 800-810-WIRE (9473)
Table of Contents
LK Programming .......................................................1-4
G1-LU, G1-PA, G1-PK, G1-TU, G1-TA, G1-TP Programming....5-8
G1-PA and G1-TA Programming........................................8
Chain Programming......................................................9
Log Sheet for Keypad Programming ......................Back Cover
Page
1
2
3
4
5
6
© SARGENT Manufacturing Company
The Keypad Lock can support 100 (LK) / 2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) users.
Each user is assigned a User Number in addition to the code used for entry.
Example for v. G1:
USER TYPE USER NUMBER
Master 01
Supervisor 02
Standard 04-97 (LK) 04-2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA)
1
For installation assistance, contact SARGENT at 800-810-WIRE (9473)
• SofLink™ Plus applications software must be used with (G1-PA & G1-TA) controller for programming
• The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is also used for programming. Users are deleted through the Master Programming Code only
• Emergency code is a 10 second unlock time and will override a thrown deadbolt on a mortise lock
• The Supervisory Code is always User “02”. The Supervisory Code allows temporary lock out of selected users, changes duration of unlock time, requests infrared interrogation output, and may add additional User Codes
Note: For LK Emergency Code is at User location “02”
The Supervisory Code is at User location “03”
• The User Codes are entered at user location “04” or higher. User numbers do not have to be used or entered sequentially
• The “Lock Out” user is location dependent. To ensure that all users are locked out of the keypad, program this user at location "04"
• The “Passage” user has precedence over all users except the “Panic” user. The lock must be toggled back into a locked state for other users to function
To Begin Programming:
The Lock Controller is preset at the factory with Master Code “1234”. Entering 1234 *will unlock the lock allowing the lever handle to retract the latchbolt.
Initial Set-Up Procedures:
• The following are typical procedures to be used when setting up your Profile Series v. G1 lock
• If a mistake is made during any of the procedures, depress the “*” key several times until the yellow LED goes out
• If no keystroke is made in a 30 sec. timeframe, the programming up to that point will default and you will have to start over
LK Programming (100 Users)
To determine programming steps for your lock:
If your label has an LK, use the programming below. If your label has a G1-LU, G1-PK, G1-PA, G1-TU, G1-TP or G1-TA, turn to programming in Section 3.
Change the Master Code
99# 1234* Yellow LED blinks 50# 1# Yellow LED blinks New Master Code* Yellow LED blinks quickly New Master Code* Yellow LED blinks slowly * Yellow LED goes out (If solid, see note)
This example uses the Factory Default 1234*
It is recommended not to use the factory default master code.
-
+
-
+
-
+
-
+
+
-
+
-
LK
Keypad Programming Instructions for the Profile Series LK and v. G1 Locks
1
© SARGENT Manufacturing Company
2
For installation assistance, contact SARGENT at 800-810-WIRE (9473)
To Enter the Emergency Code
99# Master Code* Yellow LED blinks 50# 02# Yellow LED blinks Emergency (1-6 digits)* Yellow LED blinks quickly Emergency (1-6 digits)* Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock.
• Factory Emergency Code is 4321
To Enter or Change the Supervisor Code
99# Master Code* Yellow LED blinks 50# 1# 03# Yellow LED blinks Supervisory (1-6 digits)* Yellow LED blinks quickly Supervisory (1-6 digits)* Yellow LED blinks Slowly (If solid, see note) * Yellow LED goes out
Enter A User Code
99# Master Code* or Supervisory Code* Yellow LED blinks 50# 1# (User Number 04-100)# Yellow LED blinks User Code (1-6 digits)* Yellow LED blinks quickly User Code (1-6 digits)* Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out
Enter A Passage (Maintained) Code
99# Master Code* Yellow LED blinks 50# 0# (User Number 04-100)# Yellow LED blinks User Code (1-6 digits)* Yellow LED blinks quickly User Code (1-6 digits)* Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out
Enter A One Time User Code
99# Master Code* or Supervisory Code* Yellow LED blinks 50# 5# (User Number 04-100)# Yellow LED blinks User Code (1-6 digits)* Yellow LED blinks quickly User Code (1-6 digits)* Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out
To Deactivate/Reactivate “Beep” With Key Stroke
99# Supervisory or Master Code* Yellow LED blinks 30# 0# 0# (Off) (1# = On) Yellow LED blinks * Yellow LED blinks quickly * Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out
Note: If turning beep off, not audible on last two steps.
To Clear the Entire Memory
99# Master Code* Yellow LED blinks 46# 00000# 00000# Yellow LED blinks * Yellow LED blinks quickly * Yellow LED goes solid and begins to blink * Yellow LED goes out (If solid, see note)
This deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234*, Door Number to 0001 and Unlock Time to 5 seconds. If the Master Code is not known, factory assistance will be required to clear the memory. Call 1-800-810-9473.
Keypad Programming Instructions for the Profile Series LK Lock
© SARGENT Manufacturing Company