1431 (POT or PHT) PUSH TRACK APPLICATION INSTALLATION INSTRUCTIONS
CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE For assistance, contact SARGENT at 800-727-5477 or www.sargentlock.com NOTE: AN AUXILIARY DOOR STOP IS REQUIRED
B
Pre-drill - 3/32" holes
for self tapping screws or #16 drill for
#12-24 tap for machine screws
LEFT HAND
SHOWN
DRILL AND TAP DOOR AND FRAME. SEE PAGE 4 FOR DIMENSIONS
WARNING: IF NOT PROPERLY INDEXED, DOOR CLOSER WILL NOT OPERATE PROPERLY
C
WITH A WRENCH, ROTATE THE BOTTOM SPINDLE INTO POSITION SHOWN. ALIGN ARM TO MARK ON SPINDLE TO MATCH HAND OF DOOR. SECURE ARM TO SPINDLE WITH SCREW AND WASHER PROVIDED. (LEFT HAND DOOR SHOWN)
A
LEFT HAND
RIGHT HAND
WITH PROVIDED FASTENERS, SECURE CLOSER BODY TO DOOR WITH POWER ADJUSTMENT FACING TOWARDS HINGE.
WHEN USING MORTISE NUTS:
A7194E
Copyright ©SARGENT Manufacturing. All rights reserved. Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.
1/8" HEX SOCKET
WRENCH
BACKCHECK
RANGE
DELAYED ACTION
RANGE
CLOSING SPEED
RANGE
LATCHING SPEED
RANGE
DOOR WIDTH
1431 DOOR CLOSER
(INCHES)
24-30 TURN nut 1-3 CCW
30-36 FACTORY SET
36-42 TURN nut 1-3 CW
42-48 4-6 CW
ADJUSTING DOOR TO CLOSE DUE TO HIGH DRAFT CONDITIONS MAY EXCEED ADA STANDARDS. CONSULT LOCAL ORDINANCES WHEN FIRE DOORS ARE INVOLVED.
SLIDE TRACK OVER ROLLER AND INSTALL END CAPS.
SECURE TRACK TO FRAME WITH SCREWS PROVIDED. HOLDER/BUMPER OPTION END TOWARD HINGE
1431 POT/PHT
D
E
Copyright ©SARGENT Manufacturing. All rights reserved. Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.
A7194E
2
FINAL ADJUSTMENT AND REGULATING PROCEDURE
Adjust Door speed, and Latching speed valves to achieve the desired closing time. Recommend 6 seconds minimum from 90° to the closed position.
If Backcheck is required, adjust valve to achieve a slight cushioning effect. Auxiliary stop required.
If closer is equipped with Delayed Action, regulate valve to achieve the desired delay.
ADJUST POWER TO ALLOW DOOR TO CLOSE AND LATCH.
Adjust closing power to the minimum required to reliably close and latch door.
- If door is hard to open, decrease power slightly.
- If door does not latch, increase power as required.
- Use the chart as a starting point.
- Doors adjusted with high closing power to overcome strong draft conditions may exceed ADA standards.