Sanyo TS3632, KS3032, KS2432, XS3632, XS4232 User Manual 2

...
INSTRUCTION MANUAL
Split System Air Conditioner
COOL/FAN Model
Wall-mounted type Ceiling-mounted type Recessed type
KS2432 TS2432 XS1822, XS1852
KS3032 TS3632 XS2432
KS3632 TS4232 XS3632
XS4232
Save These Instructions!
Features
These air conditioners are equipped with cooling function. Details on this function are provided below; refer to these descriptions when using the air conditioner.
Microprocessor Controlled Operation
The interior compartment of the remote control unit contains several features to facilitate automatic operation, easy logically displayed for easy use.
Simple One-touch Wireless Remote Control
The remote control unit has several features to facilitate automatic operation.
24-hour clock with ON/OFF Program Timer
The wireless remote controller allows you to set up a wide variety of time based operations. Such functions include automatic on/off with time settings, same time on/off every day, on timer and off timer.
1-Hour OFF Timer
This timer can be set to automatically turn off the unit at any time after one hour.
Night Setback
Pressing this button changes the setting of the room temperature thermostat, allowing you to set the temperature at whatever level that you find comfortable.
Air Sweep Control
This function moves a flap up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner.
Automatic Restart Function for Power Failure
Even when power failure occurs, preset programmed operation can be reactivated once power resumes.
Anti-Mold Filter
This unit is equipped with an anti-mold filter that inhibits the growth of mold and bacteria.
Automatic and 3-step Fan Speed
Auto/High/Medium/Low
2 OI-201-02EG
Contents
Page
Features.................................................................................................................. 2
Product Information .............................................................................................. 3
Alert Symbols ........................................................................................................ 3
Installation Location.............................................................................................. 4
Electrical Requirements ........................................................................................ 4
Safety Instructions ................................................................................................ 4
Names of Parts ...................................................................................................... 5
Using the Remote Control Unit ......................................................................... 11
Operation with the Remote Control Unit.......................................................... 13
1. Operation ............................................................................................... 13
2. Adjusting the Fan Speed...................................................................... 14
3. Fan Only................................................................................................. 14
4. Night Setback Mode ............................................................................ 15
Special Remarks ................................................................................................. 16
Setting the Timer ................................................................................................ 17
Using the 1-Hour OFF Timer.............................................................................. 19
Adjusting the Airflow Direction ......................................................................... 20
Operation without the Remote Control Unit .................................................... 20
Care and Cleaning............................................................................................... 21
Troubleshooting................................................................................................... 23
Tips for Energy Saving....................................................................................... 23
Operating Range ................................................................................................. 23
Product Information
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet.
Model No.
Date of purchase
Dealer’s address
Serial No.
Phone number
Alert Symbols
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
CAUTION
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
3OI-201-03EG
Avoid:
Installation Location
We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.
Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.
Do not install the air conditioner where excessively high heat­generating objects are placed.
To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.
The unit may malfunction when the receiver in the indoor unit is exposed to the inverter lamp light.
Electrical Requirements
1. All wiring must conform to the local electrical codes. Consult your
dealer or a qualified electrician for details.
2. Each unit must be properly grounded with a ground (or earth) wire or
through the supply wiring.
3. Wiring must be done by a qualified electrician.
Power supply: 60 Hz, single-phase, 230/208 volts.
CAUTION
To warm up the system, the power mains
Power mains
must be turned on at least five (5) hours before operation. Leave the power mains
ON
ON unless you will not be using this appliance for an extended period. (CL MODEL)
Safety Instructions
Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.
Never touch the unit with wet hands.
Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.
This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.
CAUTION
Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
Do not let children play with the air conditioner.
Do not cool the room too much if babies or invalids are present.
4 OI-201-04EG
Air outlet
Names of Parts
Each air conditioner as shown below consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit.
Recessed typeCeiling mounted type
Air intake
Air outlet
Air intake
Drain tube
Remote control unit
Wall mounted type
Refrigerant tubes
NOTE
Drain tube
Remote control unit
Air intake
Air outlet
Remote control unit
This illustration is based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner which you have selected.
Drain hose
Refrigerant tubes
Refrigerant tubes
Air intake The return air in the room is drawn into this section and passes through
air filters which remove dust and foreign particles.
Air outlet Conditioned air is returned to the room through the air outlet (ceiling
and wall mounted type) or four air outlets (Recessed type). The direction of airflow can be adjusted as desired using the remote control unit.
Remote control unit The wireless remote control unit controls power ON/OFF, operation
mode selection, temperature, fan speed, timer setting, and air sweeping.
Refrigerant tubes The indoor and outdoor units are connected by copper tubes through
which refrigerant gas flows.
Drain tube Moisture in the room is condensed and drains off by means of this tube.
Outdoor (condensing) unit The outdoor unit contains the compressor, fan motor, heat exchanger
coil, and other electrical components.
5OI-201-05EG
Unit Display and Operation Selector
Recessed type Ceiling mounted type
OPERATION lamp
Recessed type
Operation selector
TIMER lamp
Remote control receiver
Ceiling mounted type
Finger-hold
Air intake grille
Air intake grille
Air filter
Operation selector
6 OI-201-06EG
Unit Display and Operation Selector (continued)
INDOOR UNIT
REMOTE CONTROL receiver
OPERATION lamp
TIMER lamp
REMOTE CONTROL
receiver
Operation selector
ON position This position is for operating the air conditioner with the wireless
OFF position Switch the selector to the OFF position if you are not going to use
TEST position This position is used only when servicing the air conditioner.
CAUTION
This section picks up infrared signals from the remote control unit (transmitter).
remote control unit. Set the selector normally in this position.
the air conditioner for a few days or longer.
The OFF position does not disconnect the power. Use the main power switch to turn off power completely.
Do not set at the TEST position for normal operation.
Operation selector
OPERATION lamp This lights when the system is in the continuous COOL or FAN
mode.
TIMER lamp This lamp lights when the system is being controlled by the timer.
7OI-201-07EG
Remote Control Unit (Display)
Displayed when main unit sensor is in use
Displayed when setting temperature
HR.
1
(1) Operation mode
COOL .......................................
FAN ..........................................
SET TEMP
ON OFF AM PM
Symbols
F
Displayed when transmitting data
Displayed when temperature is shown
Displayed when the temperature setting is at the upper or lower allowable limit
Displayed when setting timer
(3) Set temperature
60–88°F
When set to 82 °F ...........
Current temperature
indication .........................
F
(2) Fan speed
Automatic operation ..............
HIGH ........................................
MEDIUM..................................
LOW.........................................
(4) Timer
24-hour clock with ON/OFF
Program Timer .......................
24-hour ON Timer ..................
24-hour OFF Timer .................
1-hour OFF Timer ...................
(5) NIGHT SETBACK ....................
(6) Confirmation of
transmission ...........................
(7) Sweep indication....................
ON
OFF
HR.
1
8 OI-201-08EG