Split System Submittal Data
System: 36KS72R Indoor/Outdoor: KHS3672R/C3672R 
Wall Mounted Air Conditioner
Job Name: 
Location: 
Engineer: 
Submitted to: 
Submitted by: 
Reference:
    General Data (at 230V)
Power     V/PH/Hz    230/208/1/60
Circuit Ampacity 
Fuse Size, Max.
Compressor
No. used 
R.L. Amps - L.R.
Outdoor Unit
Fan type  
Dia. (in.) - No. Speeds 
Type Drive - No. Speeds 
No. Poles 
No. Motors 
CFM 
F.L. Amps
           (A)             15-35 Indoor-Outdoor
            (A)            15-35 Indoor-Outdoor
DC Rotary Inverter
1
              (A)                     16.4-17.5
 Propeller
18-7/64-1 
DC Motor
         (RPM)                     8 - 830
       (W)                       1 - 90
         (High)                        1942
         (A)                          17.3
Approval: 
Date: 
Construction: 
Unit #: 
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit) 
Control 
Connection 
Line Length, Max (ft.) 
Lift Difference, Max (ft.) 
Line Size 
Line Size
Dimensions
Indoor Unit
Outdoor Unit
R410A
6.17
Electric Expansion Valve
Flare
165
50 (outdoor lower), 100 (outdoor higher)
(in. O.D. Discharge)            3/8”
(in. O.D. Suction)            5/8”
(in.)                    H x W x D
(Uncrated)    14-9/16 x 59-1/16 x 9-7/16
(Crated)     18-7/16 x 62-9/16 x 12-9/16
(Uncrated)   30-23/32 x 37 x 13-3/8
(Crated)       34-31/32 x 39-31/32 x 16-3/32
Coil Type 
Fin Type - Pipe Type 
Rows - F.P.I. 
Face Area 
Tube Size
Indoor Unit
Fan type  
Dia. & Length (in.) - No. Speeds 
No. Speeds 
No. Poles 
No. Motors 
CFM 
Indoor Sound Rating 
F.L. Amps
Coil Type 
Fin Type - Pipe Type 
Rows - F.P.I. 
Face Area 
Tube Size 
Drain Connection Size
      (sq.ft.)                        7.26
    (in.)                        3/8”
         (RPM, High)                 4 - 1273
       (W)                        1 - 50
(HI/Med/Lo)             830/710/590
       (Hi) (dB-A)                        48
         (A)                          0.5
      (sq.ft.)                        3.23
    (in.)                        3/8”
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rifeled
2 - 14.1
Cross Flow
4-13/18 L46 - 1
3 & Auto
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
3 - 12.7
 (in.)                       1-1/4”
Weight
Net 
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity 
Sensible Capacity 
Latent Capacity 
SEER 
Dehumidification 
Amps 
Power Inputs 
Outdoor Sound Rating
(lbs.)     72.8                      143 
(lbs.)     90.4                      161
(cu.ft.)    8.4                      13.0
              (Pints/H)                  10.0
             (A)                   17.9/19.8
       (dB-A)                       52
Indoor                  Outdoor
Indoor                  Outdoor
(BTU/H)    31,400 (9,500-31,400) 
(BTU/H)                22,030
(BTU/H)                 9,370
       (W)               3,750/3,750
15.9

Dimensions
Dimensional Data for 36K72R
Indoor unit : KH3672R
Dimensional Data for 36K72R
Indoor unit : KH3672R
Features
Controls 
Remote Controller 
Temperature Control 
Timer 
Night Setback 
Air Louver
Power Failure Automatic Restart 
Self-Diagnosis 
Air Filter
       (Horizontal)                       Manual
       (Vertical)                      Automatic
LCD Wireless Type, Temp. Sensor Built In
Microprocessor
IC Thermostat
24 Hr. Program
Built-In
Built-In 
Built-In
Washable, Anti-Mold
Options
Refrigerant Line Set 
Fresh Air Intake 
Airduct Extension 
Indoor Frame Extension 
Condensate Drain Pump 
Non-Removeable Remo-con Bracket
Operating Range
        Indoor Air Intake Temp.   Outdoor Air Intake Temp.
Cooling
Maximum          95F DB/71F WB           115F DB 
Minimum           67F DB/57F WB            0F DB
Available
N/A 
N/A
N/A 
Available 
Available
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive 
Wood Dale, IL 60191 USA