Features

This air conditioner is an inverter type unit that automatically adjusts capacity as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner.

Microprocessor Controlled Operation

The interior compartment of the remote control unit contains several features to facilitate automatic operation, easy logically displayed for easy use.

Simple One-touch Wireless Remote Control

The remote control unit has several features to facilitate automatic operation.

24-Hour ON or OFF Timer

This timer can be set to automatically turn the unit on or off at any time within a 24 hour period.

1-Hour OFF Timer

This timer can be set to automatically turn off the unit at any time after one hour.

Night Setback

Pressing this button changes the setting of the room temperature thermostat, allowing you to set the temperature at whatever level that you find comfortable.

Automatic and 3-step Fan Speed

Auto/High/Medium/Low

Air Sweep Control

This function moves a flap up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner.

Auto. Flap Control

This automatically sets the flap to the optimum position during heating, cooling, and drying operation.

Automatic Switching between Cooling and Heating

This unit automatically switches between cooling operation and heating operation according to the difference between the room temperature and the temperature setting.

Hot Start Heating System

Right from the start, the air is warm and comfortable. This system prevents any cold blasts at the beginning while the heat pump is warming up, or even defrosting.

Automatic Restart Function for Power Failure

Even when power failure occurs, preset programmed operation can be reactivated once power resumes.

High Power Operation

If not in Auto Operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature.

The fan speed is 1 step above “High”.

Quiet Operation

The fan rotates slower than the fan speed setting to provide a quieter operating sound.

ION Operation

While it is operating, the unit generates negative ions that freshen up the air in the room.

Anti-Mold Filter

This unit is equipped with an anti-mold filter that inhibits the growth of mold and bacteria.

Air Clean Filter

An air filter that eliminates unpleasant odors and cleans the air is available.

Purchase a replacement filter at your local dealer. (model STK-FDXB)

2

OI-802-2-EG

 

Contents

 

 

Page

Features ...................................................................................................................

2

Product Information..................................................................................................

3

Alert Symbols...........................................................................................................

3

Installation Location .................................................................................................

4

Electrical Requirements ...........................................................................................

4

Safety Instructions....................................................................................................

4

Names of Parts ........................................................................................................

5

Using the Remote Control Unit ..............................................................................

10

Operation with the Remote Control Unit ................................................................

12

1. Automatic Operation .....................................................................................

12

2. Manual Operation .........................................................................................

13

3. Adjusting the Fan Speed...............................................................................

14

4. Fan Only........................................................................................................

14

5. Night Setback Mode......................................................................................

15

6. QUIET Mode .................................................................................................

16

7. HIGH POWER Mode ....................................................................................

16

8. ION Mode......................................................................................................

16

Special Remarks....................................................................................................

17

Setting the Timer....................................................................................................

18

Using the 1-Hour OFF Timer .................................................................................

20

Tips for Energy Saving ...........................................................................................

20

Adjusting the Airflow Direction ...............................................................................

21

Operation without the Remote Control Unit ...........................................................

22

Care and Cleaning .................................................................................................

22

Troubleshooting......................................................................................................

25

Operating Range....................................................................................................

25

Product Information

If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet.

Model No. ______________________ Serial No. _______________________

Date of purchase ___________________________________________________

Dealer’s address ___________________________________________________

Phone number ___________________

Alert Symbols

The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

CAUTION

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

OI-802-3EG

3

 

Installation Location

We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.

Do not install this air conditioner where there are fumes or flammable

gases, or in an extremely humid space such as a greenhouse.

Do not install the air conditioner where excessively high heatgenerating objects are placed.

Avoid: To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.

Electrical Requirements

1.All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.

2.Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.

3.Wiring must be done by a qualified electrician.

Safety Instructions

Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.

This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.

 

 

• Never use or store gasoline or other flammable vapor or liquid near the

 

 

air conditioner — it is very dangerous.

 

 

• This air conditioner has no ventilator for intaking fresh air from

 

 

outdoors. You must open doors or windows frequently when you use

 

 

gas or oil heating appliances in the same room, which consume a lot of

 

 

oxygen from the air. Otherwise there is a risk of suffocation in an

 

 

extreme case.

 

 

 

 

 

 

 

 

• Do not turn the air conditioner on and off from the power mains switch.

CAUTION

 

 

Use the ON/OFF operation button.

 

 

• Do not stick anything into the air outlet of the outdoor unit. This is

 

 

dangerous because the fan is rotating at high speed.

 

 

• Do not let children play with the air conditioner.

 

 

• Do not cool or heat the room too much if babies or invalids are present.

 

 

 

4

OI-802-4-EG

 

Names of Parts

Air intakes

INDOOR UNIT

Air outlet

Remote control unit

Drain hose

Refrigerant tubes

OUTDOOR UNIT

Air outlet

NOTE

This illustration is based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner which you have selected.

This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit.

Air Intake

Air from the room is drawn into this section and passes through air filters which

 

remove dust.

 

 

Air Outlet

Conditioned air is blown out of the air conditioner through the air outlet.

 

 

Remote Control Unit

The wireless remote control unit controls power ON/OFF, operation mode

 

selection, temperature, fan speed, timer setting, and air sweeping.

 

 

Refrigerant Tubes

The indoor and outdoor units are connected by copper tubes through which

 

refrigerant gas flows.

 

 

Drain Hose

Moisture in the room condenses and drains off through this hose.

 

 

Outdoor (Condensing) Unit

The outdoor unit contains the compressor, fan motor, heat exchanger coil, and

 

other electrical components.

 

 

OI-802-5EG

5

 

Unit Display and Operation Button

INDOOR UNIT

IMPORTANT

Avoid using radio equipment such as mobile phone near (within 4 ft.) the remote control receiver. Some radio equipment may cause malfunction of the unit.

If the trouble happens, disconnect power and restart the air conditioner after a few minutes.

OPERATION lamp

TIMER lamp QUIET QUIET lamp

ION lamp

OPERATION button

REMOTE CONTROL receiver

REMOTE CONTROL receiver This section picks up infrared signals from the remote control unit (transmitter).

OPERATION button When the remote control cannot be used, pressing this button enables heating and cooling operation.

Each time this button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation.

Cooling operation

 

Heating operation

 

Stop

 

 

(green)

 

(red)

 

(lamp off)

OPERATION lamp This lamp lights when the system is in the continuous AUTO (red or green), HEAT (red), DRY (orange), COOL (green) and FAN (green) mode.

The OPERATION lamp lights up red and orange alternately when the system is defrosting.

TIMER lamp This lamp lights when the system is being controlled by the timer.

QUIET lamp This lamp lights during operation in the QUIET mode.

ION lamp This lamp lights during operation in the ION mode while the indoor unit is operating.

NOTE The unit’s display lamps are dimmed during operation in the NIGHT SETBACK mode.

6

OI-802-6-EG

 

Sanyo KHS0971, KHS1271 User Manual

Remote Control Unit (Display)

Displayed when transmitting data

Displayed when indoor unit sensor is in use

Displayed when setting temperature

Displayed when temperature is shown

Displayed when setting timer

Displayed when the time display is set to 12-hour time.

Symbols

(1)Operation mode

AUTO .........................................

HEAT ..........................................

MILD DRY ..................................

COOL .........................................

FAN ............................................

(2)Fan speed

Automatic operation ...................

HIGH .........................................

MEDIUM.....................................

LOW ...........................................

(3)Temperature setting 60 – 86 °F

When set to 80 °F

temperature indication................

(4)Timer

24-hour clock with ON/OFF program Timer............................

ON Timer....................................

OFF Timer..................................

1-hour OFF Timer.......................

(5)NIGHT SETBACK ......................

(6)Confirmation of transmission .....

(7)Auto. flap indication ....................

Flap angle indication ..................

Sweep indication ........................

(8)High power operation .................

(9)Quiet operation...........................

(10)ION operation ...........................

OI-802-7EG

7

 

Remote Control Unit

Transmitter

Sensor

 

Display

 

(Cover closed)

 

 

 

 

ION button

ON/OFF operation button

 

 

 

 

 

1 HR. TIMER button

 

 

 

Temperature setting buttons (TEMP.)

 

QUIET button

MODE selector button

 

FAN SPEED selector button

NIGHT SETBACK button

 

FLAP button

HIGH POWER button

 

ON TIME

Advance button

Advance button

OFF TIME

setting

 

setting

Return button

Return button

buttons

buttons

 

CLOCK button

 

CANCEL button

 

 

SENSOR button

Time display selector button

ADDRESS switch

ACL button

 

 

Temperature display

 

selector button

 

NOTE

 

The illustration above pictures the remote control unit after the cover has been

 

 

 

opened.

 

 

 

 

 

 

Transmitter

When you press the buttons on the remote control unit, the

mark appears in

 

 

 

the display to transmit the setting changes to the receiver in the air conditioner.

 

 

 

 

 

Sensor

A temperature sensor inside the remote control unit senses the room

 

 

 

temperature.

 

 

 

 

 

 

Display

Information on the operating conditions is displayed while the remote control unit

 

 

 

is switched on. If the unit is turned off, FLAP setting and FAN SPEED setting are

 

 

 

not displayed.

 

 

 

 

 

ION button

: This button is for turning the negative ions generated during operation on

 

 

 

and off.

 

 

 

 

 

 

ON/OFF operation button

This button is for turning the air conditioner on and off.

 

 

 

 

 

1 HR. TIMER button

: When you press this button, regardless of whether the unit is operating or

(1-HOUR OFF TIMER)

stopping, the unit operates for one hour and then shuts down.

 

 

 

 

 

8

OI-802-8-EG

 

Remote Control Unit (continued)

Temperature setting buttons

Press the

button to increase the set temperature.

 

 

(TEMP.)

Press the

button to reduce the set temperature.

 

 

 

 

 

The temperature setting changes by 1 °C or 2 °F each time one of the TEMP.

 

 

 

 

 

buttons is pressed.

 

 

 

 

 

 

 

 

QUIET button

: When you press this button, the fan rotates slower than the fan speed

 

 

 

 

 

 

setting to provide a quieter operating sound.

 

 

 

 

 

 

 

 

 

 

 

 

MODE selector button

Use this button to select AUTO, HEAT, DRY, COOL or FAN mode.

 

 

 

 

(AUTO)

: When this setting is selected, the air conditioner calculates the difference

 

 

 

 

 

 

 

 

 

 

between the thermostat setting and the room temperature and

 

 

 

 

(HEAT)

automatically switches to the ‘‘COOL’’ or ‘‘HEAT’’ mode as appropriate.

 

 

 

 

: The air conditioner makes the room warmer.

 

 

 

 

(DRY)

: The air conditioner reduces the humidity in the room.

 

 

 

(COOL)

: The air conditioner makes the room cooler.

 

 

 

 

(FAN)

: The air conditioner works only as a circulation fan.

 

 

 

 

 

 

 

 

 

 

FAN SPEED selector button

: The air conditioner automatically decides the fan speeds.

 

 

 

 

 

 

: High fan speed

 

 

 

 

 

 

: Medium fan speed

 

 

 

 

 

 

: Low fan speed

 

 

 

 

 

 

 

 

 

 

NIGHT SETBACK button

For details, see “5. Night Setback Mode”. When you press this button in the

 

 

 

 

 

 

HEAT, DRY or COOL mode, the mark appears in the display, and the remote

 

 

 

 

 

 

 

 

 

 

 

control unit will automatically adjust the set temperature to save energy.

 

 

 

 

 

 

 

 

FLAP button

Press this button either to select the setting of the airflow direction to the auto.

 

 

 

 

 

 

flap in each mode or one of the six possible positions manually or to select the

 

 

 

 

 

sweep function which moves the flap up and down automatically.

 

 

 

 

 

: Auto flap setting: If selected in a heating operation, the flap is set to

 

 

 

 

 

position (3) in the following chart. If selected in a cooling or dry operation,

 

 

 

 

 

the flap is set at position (7) in the following chart.

 

 

 

 

 

: The airflow direction can be set manually. (six positions)

 

 

 

 

 

: The flap moves up and down automatically.

 

 

 

 

 

When you press the FLAP button, the air flow direction will be changed one by

 

 

 

NOTE

 

 

 

 

 

 

 

one as follows.

SWEEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH POWER button

: If this button is pressed during HEAT, DRY, COOL or FAN operation, the

 

 

 

 

 

 

unit operates at maximum output for 30 minutes, regardless of the desired

 

 

 

 

 

temperature.

 

 

 

 

 

The fan speed is 1 step above “High”.

 

 

 

 

 

 

 

 

ON TIME/OFF TIME setting

No display: The timer does not operate.

 

 

 

buttons

: The air conditioner starts at the set time.

 

 

 

 

 

: The air conditioner stops at the set time.

 

 

 

 

 

 

: The air conditioner stops and starts, or starts and stops, at the

 

 

 

 

 

 

set times every day. For details, see “Setting the Timer”.

 

 

 

 

 

 

 

 

 

 

OI-802-9EG

9

 

Remote Control Unit (continued)

SENSOR button When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly.

NOTE If the remote control is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.

Temperature Display Selector This switches the temperature display between °C and °F. button

Time Display Selector button This switches the time display between 24-hour time and 12-hour time.

ACL button (ALL CLEAR) Puts the remote control unit into pre-operation status. Always press this button after replacing the batteries.

ADDRESS switch • The address switch changes to prevent mixing of signals from remote control units when two air conditioners are installed next to each other. Normally, the address switch is set to A. For more information, please contact the dealer where you made the purchase.

Normally, the tabs on the remote control unit should not be bent.

NOTE The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

Using the Remote Control Unit

How to Install Batteries

 

1.

Slide the cover in the direction

 

 

indicated by the arrow and remove it.

 

2.

Install two AAA alkaline batteries.

 

 

Make sure the batteries point in the

 

 

direction marked in the battery

 

 

compartment.

 

3.

Use a thin object such as the tip of a

 

 

pen to press the ACL button.

ACL button

 

NOTE

• The batteries last about six months, depending on how much you use

 

the remote control unit. Replace the batteries when the remote control

 

unit’s display fails to light, or when the remote control cannot be used to

 

change the air conditioner’s settings.

Use two fresh leak-proof type-AAA alkaline batteries.

In replacing batteries, follow the instructions as mentioned in the subsection “How to Install Batteries”.

If you do not use the remote control unit more than 1 month, take out the batteries.

10

OI-802-10-EG

 

Using the Remote Control Unit (continued)

How to Use the Remote When using the remote control unit, always point the unit’s transmitter head Control Unit directly at the air conditioner’s receiver.

Air conditioner (Indoor unit)

 

Receiver

Remote control

(Transmitter head)

unit

 

Remote Control Unit The remote control unit may be operated either from a non-fixed position or from Installation Position a wall-mounted position. To ensure that the air conditioner operates correctly, DO

NOT install the remote control unit in the following places:

DO NOT • In direct sunlight

Behind a curtain or other places where it is covered

More than 26 feet (8 m) away from the air conditioner

In the path of the air conditioner’s airstream

Where it may become extremely hot or cold

Where it may be subject to electrical or magnetic noise

Where there is an obstacle between the remote control unit and air conditioner (since a check signal is sent from the remote control unit every 5 minutes)

Mounting the Remote Control Before mounting the remote control unit, press the ON/OFF operation button at Unit the mounting location to make sure that the air conditioner operates from that

location. The indoor unit should make a beeping sound to indicate that it has received the signal.

Remote control

Rear side

 

unit mount

 

Press

Mounting screws

5/32 x 5/8" (4 x 16 mm)

(included)

Set in place

Hole

To prevent loss of the remote control unit, you can connect the remote control unit to the mount by passing a string through the remote control unit and attachment hole.

 

To take out the remote control unit, pull it forward.

When Holding the Remote

• When using the remote control unit and during air conditioner operation, the

Control Unit

transmitter on the remote control unit should be pointed toward the receiver

 

on the indoor unit.

 

• Make sure that there are no objects between the remote control unit and

 

receiver which could block the signal.

OI-802-11EG

11

 

 

Operation with the Remote Control

 

Unit

1. Automatic Operation

This unit automatically switches between cooling operation and heating operation

 

according to the difference between the room temperature and the temperature

 

setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 2

STEP 1

NOTE Check that the circuit breaker on the power panel is turned on.

Once mode is selected and the unit is preset by following the steps below, you can have the air conditioner automatically bring the room to the desired temperature simply by pressing the ON/OFF operation button.

STEP 1

Press the MODE selector button to .

STEP 2

Press the ON/OFF operation button.

 

To stop the air conditioner, press the ON/OFF operation button again.

 

• To change the temperature setting; press the temperature setting buttons and

NOTE

 

change the setting to the desired temperature.

 

12

OI-802-12-EG

 

Operation with the Remote Control Unit (continued)

2. Manual Operation

STEP 2

STEP 3

STEP 1

STEP 4

STEP 5

NOTE Check that the circuit breaker on the power panel is turned on.

If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired.

STEP 1

Press the MODE selector button and select the desired mode.

 

For heating operation

 

For dehumidifying operation

 

For cooling operation

 

For fan only operation

STEP 2 To start the air conditioner, press the ON/OFF operation button.

STEP 3 Press the TEMP. setting buttons to change the temperature setting to the desired temperature.

Adjustable temperature range:

30 °C max.

or

86 °F max.

16 °C min.

 

60 °F min.

STEP 4 Set the FAN SPEED selector button to the setting you want.

STEP 5 Press the FLAP button and set the airflow direction as desired. (Refer to “Adjusting the Airflow Direction” on page 21.)

To stop the air conditioner, press the ON/OFF operation button again.

OI-802-13EG

13

 

Operation with the Remote Control Unit (continued)

NOTE

• Choose the best position in the room for the remote control unit, which also

 

acts as the sensor for room comfort and transmits the operating instructions.

 

Once you’ve found this best position, always keep the remote control unit

 

there.

 

• This appliance has a built-in 5-minute time delay circuit to ensure reliable

 

operation. When the operation button is pressed, the compressor will start

 

running within three minutes. In the event of power failure, the unit will stop.

3.Adjusting the Fan Speed

A. Automatic fan speed Simply set the FAN SPEED selector button to the position.

This automatically sets the best fan speed for the room temperature.

B. Manual fan speed If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired. [, , or ]

4. Fan Only

STEP 2

STEP 1

STEP 3

If you want to circulate air without any temperature control, follow these steps:

STEP 1 Press the MODE selector button to switch to the fan mode .

STEP 2 Press the ON/OFF operation button.

STEP 3 Press the FAN SPEED selector button to select the fan speed of your choice (, or ).

14

OI-802-14-EG

 

5. Night Setback Mode

A.In Cooling and DRY Mode: ( and )

Operation with the Remote Control Unit (continued)

Night Setback Mode is used for saving energy.

Press the NIGHT SETBACK button while operation.

The mark appears in the display.

To release the night setback function, press the NIGHT SETBACK button again.

When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was made, and then another 2 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

 

 

 

 

 

 

 

2 °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature

 

2 °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the NIGHT

 

30 min.

 

30 min. Time

 

SETBACK button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. In Heating Mode: ( )

 

When the night setback mode is selected, the air conditioner automatically

lowers the temperature setting 4 °F when 30 minutes have passed after the

selection was made, and then another 4 °F after another 30 minutes have

passed, regardless of the indoor temperature when night setback was

selected. This enables you to save energy without sacrificing comfort. This

function is convenient when gentle heating is needed.

Setting

4 °F

temperature

 

 

4 °F

Press the NIGHT

30 min.

30 min.

Time

SETBACK button

 

 

 

 

 

 

OI-802-15EG