WEA412h (Indoor type) Quick Installation Manual
This manual describes the Wireless Enterprise WEA412h configuration and
installation instructions.
Introduction
What is WEA412h?
WEA412h is an Access Point (AP) which supports IEEE 802.11ac wave1 standards and
it connects wireless devices such as smartphone, laptop, tablet and etc. to a wired
network in a hospitality environment such as hotel, dormitory, and condominium.
The WEA412h supports the following features.
- IEEE 802.11a/b/g/n/ac standards
- 2.4 GHz and 5 GHz concurrent radios.
- 2 × 2 Multiple Input Multiple Output (MIMO)
- Gigabit Ethernet 1 port (PoE In) for a WAN connection
- Gigabit Ethernet 4 ports (PoE Out 1 port) for an uplink connection for wired network
- Power over Ethernet (PoE) IEEE 802.3af/802.3at
- External 48 V/0.75 A power adaptor (Optional).
- PoE Output of 10 watts max with 802.3at mode or using 48 V/0.75 A power adaptor.
- A tricolored LED displaying the operational status of WEA412h.
- One USB port (Host 2.0)
Components
After unpacking the WEA412h, confirm that all of the following items have been included:
Side View
Torx Security Screw Hole
DC Input
Left Side
Right Side
Torx Security Screw Hole
Kensington Security Slot
USB
Factory Reset Switch
Interface
Port Name Description
Tricolored LED Displays the operational status of WEA412h using a tricolored LED.
DC Input This is for connecting the power adapter.
Ethernet Port ( PoE In) Suppor ts 1000 BASE-T Gigabit Ethernet and IEEE 802.3af /802.3at PoE mode.
Ethernet Port
(LAN1~LAN4)
USB Port Supports BLE and ZigBee dongle and provides the 2.5 W output power.
Factory reset switch Used to reset the WEA412h to the initial factor y settings.
Suppor ts 1000 BASE-T Gigabit Ethernet and a PoE Output for the L AN1 port.
WE A412h
Bracket for the standard junction box
(standard gang junction box)
Ordered separately
Wall Mount Bracket Four plastic anchors Four Phillips screws (M4, L50)
- It is recommended to keep all packaging materials and the box.
- The power adaptor is sold separately. If necessary, contact the retailer.
Four Phillips screws
(UNC # 6-32, L8 )
Two Security Torx
(T10) screws
Installation
Manual
LED status indicator
LED Status Description
System start status White On Initial LED status
Blue On Device reset and test in progress
Red On Booting failure ( Device reset failure )
Provisioning status Red, Green, and
Normal operation
status
Upgrade Blue blinking Software upgrade in progress
Error status Red blinking Physical connection error of network
Off repeatedly
Green blinking CAPWAP connection in progress (APC server connection normal)
Green On When the re is no connected wireless device
Blue On When the re is a connected wireless device
Yellow blinking IP address conflict
Purple blinking Dynamic IP address allocation failure
Bluish-green blinking Logical connection error of network
Off Wireless interface error
APC connection in progress (Network link normal)
Installation
WEA412h can be installed on a general wall or on the standard junction box.
Please confirm that all of the components have been included before installation.
Names and Functions
Front and Rear View
Bottom View
Ethernet Port
(PoE Out)
Ethernet
Port
Ethernet Port (PoE In)
LED status
indicator
Before Installation
Safety Requirements
Carefully observe the following safety warnings in order to avoid the risk of damage or injury.
For safe use, make sure to be well-informed.
- There is a risk of electrical shock. Make sure that the power is turned off during installation. Do not proceed
with the installation if there is any electrical current leaking. It may cause a serious electric shock.
- Wear anti-static gloves or take an appropriate action to prevent ESD when handling the product.
- Do not connect a phone line to an Ethernet port. This may damage the product.
- This product must be connected to a power supply in compliance with IEEE 802.3af/at or connected to a
limited power supply in compliance with IEC60950.
- This product must be installed in a vertical direction. To prevent damage of a product and burns of a user
due to heat caused when the product is installed in a horizontal direction, an operation of wireless LAN is
compulsorily restricted when the surface temperature of the product exceeds IEC60950 standards (95°C).
- This product must be installed or removed by only appropriately trained service personnel.
- This product operates in the Safety Extra Low Voltage (SELV) state in compliance with IEC60950.
- All the connected equipment including this product must be installed inside of the same building.
For more details, refer to the Environment A of IEEE 802.3af/at standards.
- During installation, this product must be installed at least 3 m or more apart from WiBro/3G/4G repeater or
antenna.
Installation Instructions
The following instructions must be carefully observed during installation.
- The system must be installed in a place that is easily accessible for product installation,
cable connections, and maintenance.
- The PoE cable must be always installed away from any electrical interference source
such as power lines, fluorescent lights or transmitters.
- The PoE cable must be Cat 5e or higher.
- When PoE is unavailable, a power adapter (sold separately) can be used.
The 3-pin (including ground) power socket that supplies 100~240 V AC, 50~60 Hz must
be located within 2 m from each equipment and the power must be supplied through an
independent circuit breaker.
It is recommended to use the equipment that uses a filter or a surge.
- Whether a USB port and a PoE output port (LAN1/PoE Out) operate or not according to
a power pull-in source is as follows.
1) Power adapter: an USB port (2.5 W) and a PoE output port (15.4 W) available
2) 802.3at: an USB port (2.5 W) and a PoE output port (10 W) available
3) 802.3af: both an USB port and a PoE output port are disabled
Wall-mount installation on a junction box
Couple and assemble screws fitting to the type of
1.
the standard junction box.
Location and number of screws to be coupled
vary depending on the standard junction box.
: Standard gang junction box (Box for 1-Korea/USA)
: Standard gang junction box (Box for 2-Korea/USA)
: Standard gang junction box (Box for 1-EU)
Connect an Ethernet cable to the Ethernet (PoE In)
2.
port by passing through the standard junction box.
Hang the Ethernet cable on the wall mounting
2.
bracket as shown in the picture.
Mount the standard junction box bracket on the wall
3.
mounting bracket. (There is hook type fasteners to
help mounting)
1) Use a hammer to insert 4 plastic anchors into the
4.
drilled holes on the wall.
2) Align the inserted plastic anchors with the screw
holes of the bracket.
3) Tighten the wall mounting bracket and the
standard junction box bracket to a wall using four
M4 × L50 screws.
1) Mount the AP on the bracket using two holes in
3.
the lower end of the AP.
2) Push the AP backward and tightly connect the
AP to the bracket.
Fasten the AP to the bracket using Torx security
4.
screws (each one on the left/right sides).
Connecting RJ11 phone cable coming from the
standard junction box
Pull forward the RJ11 cable by passing through the rectangular hole on the bracket
1.
as shown in the picture.
Connect the Ethernet cable to the Ethernet port (PoE In).
5.
1) Mount the AP on a bracket using a hole in the
6.
lower of the AP.
2) Push the AP backward and tightly connect the
AP to the bracket.
Fasten the AP to the bracket using Torx security
7.
screws (each one on the left/right sides).
Installing Anti-theft lock cable
When installing the WEA412h AP in a public place, it is recommended to use anti-theft
lock cables to prevent any loss. (An anti-theft lock cable can be purchased separately and
a variety of products are available in the market.)
Standard junction box
Connect to the Ethernet port
Bracket for the standard
Pass through the RJ11 cable into the cable groove
2.
located in the lower end of the product.
1) Fitting the left/right protrusion of the lower end of
3.
the bracket into the hole of the bottom of the AP.
RJ45 Cable
(PoE In)
junction box
RJ11 cable leaves
RJ11 Cable
Connect to the phone
Protrusion
for preventing
2) Push the AP backward and tightly connect the
AP with the bracket.
RJ11 Cable
Wall-mount installation directly on wall
(Wall mounting bracket, Anchors and Screws can be
ordered separately)
Mark 4 screw holes along the following dimensions on
1.
a wall and drill them. (You can easily mark the screw
holes by using a 1:1 sized drawing in the WEA412h
Quick Installation Manual.)
62 mm
62 mm
Connect the anti-theft lock cable to the WEA412h AP.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
The 5150-5250 MHz band is restricted to indoor use only.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this devicemust accept any interference, including interference that may cause undesired operation of thedevice.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 50 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
RSS-102 RF Exposure
L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 50 cm entre la source de radiation (l’antenne) et toute
personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur.
Electromagnetic Wave Suitability Notice
Class B Equipment (For Home Use Broadcasting & Communication Equipment)
This equipment is home use (Class B) electromagnetic wave suitability equipment and to be used mainly at home and it can be
used in all areas.
Regulatory Information
‘Hereby, Samsung Electronics, declares that this WEA412h is in compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC.’
The original Declaration of Conformity may be found at http://www.samsungdocs.com, go to Search Product and enter the model name.
AEEE Yönetmeliğine Uygundur (Compliant with WEEE)
产品中有害物质的名称及含量
部件名称
金屬 料件 × ○ ○ ○ ○ ○
印刷电路板部件 × ○ ○ ○ ○ ○
線材 × ○ ○ ○ ○ ○
塑膠件 ○ ○ ○ ○ ○ ○
本表格依据SJ/T11364的规定编制
○: 表示该有害物质在该部件所有均质材料中的含量均在GB/T26 572规定的限量要求以下。
×: 表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T26 572规定的限量 要求。
本表格提供的信息是基于供应商提供的数据及三星公司的检测结果。在当前技术水平下、所有有毒有害物质或元素的使用控制到了最底线。三星公司会继续努
力通过改善技术来减少这些物质和元素的使 用。
(Pb)
铅
(Hg)
汞
(Cd)
有害物質
镉
六价铬 (Cr6+) 多溴联苯 (PBB)
多溴二苯 醚
(PBDE)
http://www.samsungenterprise.com
Part No.: EC68-00198A (Ver.1.0)