SAMSUNG M965CEXSA Service Manual

MICROWAVE OVEN

M965CE

SERVICE

MICROWAVE OVEN

 

CONTENTS

1. Precaution

2. Specifications

3. Operating Instructions

4. Disassembly and Reassembly

5. Alignment and Adjustments

6. Troubleshooting

7. Exploded Views and Parts List

8. PCB Diagrams

9. Schematic Diagrams

SEAU

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

(a)Do not operate or allow the oven to be operated with the door open.

(b)Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary:

(1)Interlock operation,

(2)proper door closing,

(3)seal and sealing surfaces (arcing, wear, and other damage),

(4)damage to or loosening of hinges and latches,

(5)evidence of dropping or abuse.

(c) Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.

(d)Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.

(e)A Microwave leakage check to verify compliance with the Federal performance standard should be performed on each oven prior to release to the owner.

Samsung Electronics

1. Precaution

Follow these special safety precautions. Although the microwave oven is completely safe during ordinary use, repair work can be extremely hazardous due to possible exposure to microwave radiation, as well as potentially lethal high voltages and currents.

1-1 Safety precautions ( )

1.All repairs should be done in accordance with the procedures described in this manual. This product complies with Federal Performance Standard 21 CFR Subchapter J (DHHS).

2.Microwave emission check should be performed to prior to servicing if the oven is operative.

3.If the oven operates with the door open : Instruct the user not to operate the oven and contact the manufacturer and the center for devices and radiological health immediatly.

4.Notify the Central Service Center if the microwave leakage exceeds 5 mW/cm2

5.Check all grounds.

6.Do not power the MWO from a "2-prong" AC cord. Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields.

7.When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers.

8.Make sure that there are no cabinet openings through which people--particularly children--might insert objects and contact dangerous voltages. Examples: Lamp hole, ventilation slots.

9.Inform the manufacturer of any oven found to have emmission in excess of 5 mW/cm2, Make repairs to bring the unit into compliance at no cost to owner and try to determine cause.

Instruct owner not to use oven until it has been brought into compliance.

CENTRAL SERVICE CENTER

11.To avoid any possible radiation hazard, replace parts in accordance with the wiring diagram. Also, use only the exact replacements for the following parts: Primary and secondary interlock switches, interlock monitor switch.

12.If the fuse is blown by the Interlock Monitor Switch: Replace all of the following at the same time: Primary, door sensing switch and power relay, as well as the Interlock Monitor Switch. The correct adjustment of these switches is described elsewhere in this manual. Make sure that the fuse has the correct rating for the particular model being repaired.

13.Design Alteration Warning:

Use exact replacement parts only, i.e., only those that are specified in the drawings and parts lists of this manual. This is especially important for the Interlock switches, described above. Never alter or add to the mechanical or electrical design of the MWO. Any design changes or additions will void the manufacturer's warranty.10.Always unplug the unit's AC power cord from the AC power source before attempting to remove or reinstall any component or assembly.

14.Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-state heat sinks are correctly installed.

15.Some semiconductor ("solid state") devices are easily damaged by static electricity. Such components are called Electrostatically Sensitive Devices (ESDs). Examples include integrated circuits and field-effect transistors.

Immediately before handling any semiconductor components or assemblies, drain the electrostatic charge from your body by touching a known earth ground.

10.Service technicians should remove their watches while repairing an MWO.

16.Always connect a test instrument's ground lead to the instrument chassis ground before connecting the positive lead; always remove the instrument's ground lead last.

Samsung Electronics

1-1

Pretaution

1-2 Special Servicing Precautions (Continued)

17.When checking the continuity of the witches or transformer, always make sure that the power is OFF, and one of the lead wires is disconnected.

18.Components that are critical for safety are indicated in the circuit diagram by shading, or .

19.Use replacement components that have the same ratings, especially for flame resistance and dielectric strength specifications. A replacement part that does not have the same safety characteristics as the original might create shock, fire or other hazards.

1-3 Special High Voltage Precautions

1.High Voltage Warning

Do not attempt to measureany of the high voltages--this includes the filament voltage of the magnetron. High voltage is present during any cook cycle.

Before touching any components or wiring, always unplug the oven and discharge the high voltage capacitor (See Figure 1-1)

2.The high-voltage capacitor remains charged about 30 seconds after disconnection. Short the negative terminal of the high-voltage capacitor to to the oven chassis. (Use a screwdriver.)

3.High voltage is maintained within specified limits by close-tolerance, safety-related components and adjustments. If the high voltage exceeds the specified limits, check each of the special components.

PRECAUTION

There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the HIGH VOLTAGE TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on or near these circuits with the oven energized.

DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.

H. V. Capacitor

H. V. Diode

Short

Touch chassis ground first then short to the high voltage capacitor terminal by using screwdriver or jumper wire.

PRECAUTION

Never touch any circuit wiring with your hand nor with uninsulated tool during operation.

PRECAUTION

Servicemen should remove their watches whenever working close to or replacing the magnetron.

1-2

Samsung Electronics

2. Specifications

2-1 Table of Specifications

TIMER

99 MINUTES 90 SECONDS

 

 

 

 

 

POWER LEVEL

 

 

 

 

 

 

 

 

POWER SOURCE

240V 50Hz, AC

 

 

ON TIME

OFF TIME

 

%

M965CE

 

 

 

 

 

 

 

 

 

POWER CONSUMPTION

MICROWAVE : 1,550W

 

 

 

 

 

10%

100W

4 sec

26 sec

 

OUTPUT POWER

FROM 100 TO 1000W (10 LEVEL POWER)

20%

200W

7 sec

23 sec

 

30%

300W

10 sec

20 sec

 

 

 

 

 

(IEC-705 TEST PROCEDURE)

40%

400W

13 sec

17 sec

 

OPERATING FREQUENCY

2,450MHz

50%

500W

16 sec

14 sec

 

60%

600W

19 sec

11 sec

 

 

 

 

MAGNETRON

OM75PH(31)

70%

700W

22 sec

8 sec

 

COOLING METHOD

COOLING FAN MOTOR

80%

800W

25 sec

5 sec

 

90%

900W

28 sec

2 sec

 

 

 

 

OUTSIDE DIMENSIONS

517(W) x 297(H) x 385(D)

100%

1000W

30 sec

0 sec

 

 

 

 

 

 

 

 

Samsung Electronics

2-1

SAMSUNG M965CEXSA Service Manual

3. Operating Instructions

3-1 Control Panel

Sensor Reheat Button

Sensor

 

Sensor

Sensor Cook Button

Reheat

 

Cook

 

 

 

 

Drinks

Baked

Frozen

 

 

Beans

Vegetables

 

 

Peeled

 

 

One Touch Cook Buttons

 

Pasta

Stewed

 

 

Potatoes

 

Fruit

 

 

Memory

Memory

Sound

Sound Button

 

I

II

 

 

 

Momory I and Memory II Button

 

 

 

 

Help Mate Button

Help

 

One

One Minute + Button

Mate

More

Minute +

 

 

 

More / Less Button

Auto Defrost Button

Auto

Less

 

Power

Power Level Button

 

 

Defrost

 

Level

 

 

 

 

1

2

3

 

Number Key Buttons

4

5

6

 

 

7

8

9

 

Hold Timer Button

Hold

0

Clock

Clock / Auto Start Button

Timer

AutoStart

 

 

 

Pause Cancel Button

Pause

 

Start

Start Button

Cancel

 

 

 

 

 

 

 

 

M965CE

 

3-2 Features & External Views

Door

Ventilation Holes

Safety Interlock Holes

 

 

Control Panel

Door Latches

 

 

 

 

Open Door Push Button

 

Glass Plate

Guide Roller

297 mm

517 mm

385 mm

.3-1

Samsung Electronics

4. Disassembly and Reassembly

4-1 Replacement of Magnetron, Motor Assembly and Lamp

Remove the magnetron including the shield case, permanent magnet, choke coils and capacitors (all of which are contained in one assembly).

1.Disconnect all lead wires from the magnetron and lamp.

2.Remove a screw securing the magnetron supporter.

3.Remove the thrmo S/W.

4.Remove the air cover.

5.Remove screws securing the magnetron to the wave guide.

6.Take out the magnetron very carefully.

7.Remove screws from the back panel.

8.Take out the fan motor.

9.Remove the oven lamp by rotating to pull out from hole of air cover.

NOTE1: When removing the magnetron, make sure that its antenna does not hit any adjacent parts, or it may be damaged.

NOTE2: When replacing the magnetron, be sure to remount the magnetron gasket in the correct position and make sure the gasket is in good condition.

Cover Air

Thermo S/W

Lamp

Fan Motor

 

 

 

Screw

 

 

 

Magnetron H. V. Trans

 

 

 

 

H. V. Capacitor

 

4-1 Replacement of High Voltage Transformer

1.Discharge the high voltage capacitor.

2.Disconnect all the leads.

3.Remove the mounting bolts.

4.Reconnect the leads correctly and firmly.

PRECAUTION

Servicemen should remov their watches whenever working close to or replacing the magnetron.

PRECAUTION

 

 

There exists HIGH VOLTAGE ELECTRICITY with high

 

 

current capabilities in the circuits of the HIGH

 

 

VOLTAGE TRANSFORMER secondary and filament

 

 

terminals. It is extremely dangerous to work on or

 

 

near these circuits with the oven energized.

Screws

H. V. Trans

DO NOT measure the voltage in the high voltage

 

circuit including filament voltage of magnetron.

 

 

Samsung Electronics

4-1

Loading...
+ 16 hidden pages