Samsung M935, M935-XEE Disassemble

Remove the magnetron including the shield case, permanent magnet, choke coils and capacitors (all of which are contained in one assembly).
1. Disconnect all lead wires from the magnetron and lamp.
2. Remove a screw securing the magnetron supporter.
3. Remove the magnetron supporter.
5. Remove screws securing the magnetron to the wave guide.
6. Take out the magnetron very carefully.
7. Remove screws from the back panel.
8. Take out the fan motor.
9. Remove the oven lamp by rotating to pull out from hole of air cover.
NOTE1: When removing the magnetron, make
sure that its antenna does not hit any adjacent parts, or it may be damaged.
NOTE2: When replacing the magnetron, be sure to
remount the magnetron gasket in the correct position and make sure the gasket is in good condition.
1. Discharge the high voltage capacitor.
2. Disconnect all the leads.
3. Remove the mounting bolts.
4. Reconnect the leads correctly and firmly.
Lamp
Magnetron
H. V. Trans
H. V. Capacitor
Nuts or Screw
Thermo S/W
Fan Motor
P-ALL
P-HVT
H. V. Trans
Screws
4. Disassembly & Reassembly
Samsung Electronics 4-1
4-1 Replacement of Magnetron, Motor Assembly and Lamp
4-2 Replacement of High Voltage Transformer
4-2 Samsung Electronics
Disassembly & Reassembly
4-3 Replacement of Door Assembly
4-3-1 Removal of Door Assembly
Remove hex bolts securing the upper hinge and lower hinge. Then remove the door assembly.
Insert flat screwdriver into the gap between Door "E" and Door "C" to remove Door "C". Be careful when handling Door "C" because it is fragile.
Following the procedure as shown in the figure, insert and bend a thin metal plate between Door "E" and Door "A" until you hear the 'tick' sound.
1. Insertion depth of the thin metal plate should be
0.5mm or less.
4-3-4 Removal of Key Door & Spring
Remove pin hinge from Door "E"
Detach spring from Door "E" and key door.
4-3-2 Removal of Door "C"
4-3-3 Removal of Door "E"
Upper Hinge
Lower Hinge
Screws
Screws
Key Door Spring
Door "E"
Loading...
+ 1 hidden pages